• 제목/요약/키워드: AC energy

검색결과 1,020건 처리시간 0.03초

역률개선 회로를 적용한 Desk-Top Robot (Desk-Top Robot with Power Factor Correction)

  • 천광수;김학진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.343-346
    • /
    • 2007
  • Recently, many nations have released standard such as EN61000-3-2 to impose a limit on the harmonic current to prevent distortion of AC line and to save energy. Also, the limit on the harmonic current makes use of a trade barrier. Therefore, Power factor correction must have been suitable for a limit on the harmonic current. This paper presents AC servo motor drive to have merits of high power factor for Desk-Top Robot.

  • PDF

Conformational Role of Proline in $\alpha$-Helices

  • Kang, Young-Kee;Kim, Mee-Kyoung
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 1998년도 학술발표회
    • /
    • pp.22-22
    • /
    • 1998
  • Conformational energy calculations have been carried out for proline-containing alanine-based pentadecapeptides with the sequence Ac-(Ala)/sun n/-Pro-(Ala)$_{m}$-NHMe (n + m = 14), in order to figure out the positional preference of proline in $\alpha$-helices. The conformational energy was computed a sum of the potential energy (ECEPP/3) and the hydration free energy computed by the hydration shell model.(omitted)d)

  • PDF

PWM chopper 에 의한 태양전지의 출력제어 (Output control of solar cells using PWM chopper)

  • 유권종;김용식;박이준;송진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.401-404
    • /
    • 1990
  • A new control method of solar cell output using PWM chopper is described. Theoretical analysis and comparision for all sorts of system are also discussed for improving photovoltic system efficiency. It is expected that the result of this study will be utilized to some other DC or AC application equipments.

  • PDF

태양광 위치 추적 제어를 고려한 에너지 Harvesting AC/DC 전력 변환기 구동에 관한 연구 (A Study on AC/DC Power Converter of Energy Harvesting for Considered to Solar Position Tracking Control)

  • 나승권;구기준
    • 한국항행학회논문지
    • /
    • 제18권1호
    • /
    • pp.56-66
    • /
    • 2014
  • 태양광 발전에 있어서 태양전지는 일사량, 온도와 부하에 의해 크게 변동하기 때문에 태양전지에 대한 특성 해석이 필요하다. 또한 태양광 발전에 있어서 가능한 많은 에너지를 얻기 위해서는 환경변화에 따른 태양의 위치추적이 필요하며 태양전지의 출력을 항상 최대로 제어할 필요가 있다. 센서와 마이크로프로세서 칩으로 구현된 본 시스템의 실험 결과는 Boost 컨버터의 승압율은 167[%], 소용량에서 에너지 Harvesting 개념과 위치추적 방식의 태양광 발전 구현 가능성을 제시하였다.

계통연계형 태양광 PCS의 병렬운전 (Parallel operation of grid-connected PV PCS)

  • 이기옥;정영석;소정훈;유병규;유권종;최주엽;최익
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.299-301
    • /
    • 2006
  • 계통연계형 태양광 시스템을 구성하고 있는 전력변환장치인 PCS(power conditioning system)는 일반적으로 그 내부에 입력전력 평활용 Capacitor, DC-DC Converter, DC link Capacitor, DC-AC Inverter 및 L-C Filter 등으로 구성된다. 이러한 태양광 시스템의 구성은 주로 태양광 어레이와 PCS의 DC-DC Converter 및 DC-AC Inverter의 수와 연결 방법에 따라 여러 가지로 구성할 수가 있다. 본 논문에서 제안할 시스템의 구성은 하나의 태양광 어레이를 다수의 계통연계형 태양광 PCS가 공유하는 형태인데, 이러한 시스템의 주요 장점은 첫째, 일사량에 따라 각각의 PCS가 모두 정격에서 운전하도록 하여 변환효율을 개선할 수 있다는 점과 둘째, 태양광 어레이의 용량 확장에 따른 PCS 장치의 용이한 확장성 그리고 셋째, 연결되어 있는 다수의 PCS 중 하나의 태양광 PCS가 고장으로 인하여 유지 및 보수가 필요할 때에도 그 외의 다른 정상적인 태양광 PCS는 지속적인 발전이 가능한 장점 등을 갖는다. 본 논문에서는 태양광 어레이의 출력을 공유하는 병렬운전용 태양광 PCS의 구성에 대하여 연구하고, 그 병렬운전기법을 제시하여 이에 대한 타당성을 시뮬레이션으로 검증하고자 한다.

  • PDF

연료전지 자동차 세계기술규정의 감전보호기준 연구 (Research on Standards for Protection against Electric Shock in Global Technical Regulations of Fuel Cell Vehicle)

  • 황보천;이규명;유경준
    • 한국수소및신에너지학회논문집
    • /
    • 제21권3호
    • /
    • pp.167-183
    • /
    • 2010
  • This paper analyzes the backgrounds of the standards for protection against electric shock in Global Technical Regulations (GTR) of Fuel Cell Vehicle (FCV). Targets on research were high voltage criteria, safety current, isolation and grounding resistance, time limitation, energy, adequate clearance, and test procedure. Based on human impedance and effect of current in IEC 60479-1, safety of human was examined. Then, isolation and grounding circuit model of FCV were analyzed theoretically. The results give several suggestions: touch voltage less than 25V, AC energy less than 0.0813J, separation considering middle finger length, grounding resistance less than $0.2\Omega$, maximum AC ground voltage of 1V (rms), and isolation resistance between earth and electrical chassis. In MATLAB/Simulink environment, error characteristics of isolation resistance measurement procedure using internal DC sources were analyzed under variations of internal resistance of voltmeter and isolation resistance.

Utililty-Interfaced High-Frequency Flyback Transformer Linked Sinewave Pulse Modulated Inverter for a Small Scale Renewable Energy Conditioner

  • Chandhaket, Srawouth;Koninish, Yoshihiro;Nakaoka, Mutsou
    • Journal of Power Electronics
    • /
    • 제2권2호
    • /
    • pp.112-123
    • /
    • 2002
  • This paper presents a novel prototype of the utility AC power interfaced soft-switching sinewave pulse modulated inverter using the high-frequency flyback for the small scale distributed renewable energy power conditioner. The proposed cricuit with a high-frequency isolation link has a funtion of electrical isolation, which is more cost-effective and reliable for the small-scale distributed renwal energy utilization system from a safety point of riew. The discontinuous conduction mode(DCM) operation of the high-frequency flyback transformer is adopted to establish a simple and low-cost circuit configuration and control scheme. For the simplicity, the circuit operating principle is described on the basis of the modified conventional full bridge inverter, whitch is the typical conventional high-frequency full-bridge inverter employing the high requency flyback transformer to eanble the effictive function of the electrical isolation. Than, the new circuit topology of the unility-interfaced soft-switching sinewave pulse modulated inverter using IGBTs is proposed. The proposed cricuit topology is additionally composed of the auxiliary power regenerating snubber cricuits, which are also mathematically analyzed for the parameter desigen settings. Finally, the performance of the propose inverter is evaluated on the basis of computer-aid simulation. It is noted that the sinewave pulse modulated output current of the inverter is synchronous to the AC main voltage.

계통연계형 태양광 PCS의 병렬운전기법 (Parallel operation of grid-connected PV PCS)

  • 이기옥;정영석;소정훈;유병규;유권종;최주엽;송승호;최익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.230-231
    • /
    • 2007
  • 계통연계형 태양광 시스템을 구성하고 있는 전력변환장치인 PCS(power conditioning system)는 일반적으로 그 내부에 입력전력 평활용 Capacitor, DC-DC Converter, DC link Capacitor, DC-AC Inverter 및 L-C Filter 등으로 구성된다. 이러한 태양광 시스템의 구성은 주로 태양광 어레이와 PCS의 DC-DC Converter 및 DC-AC Inverter의 수와 연결 방법에 따라 여러 가지로 구성할 수가 있다. 본 논문에서 제안할 시스템의 구성은 하나의 태양광 어레이를 다수의 계통 연계형 태양광 PCS가 공유하는 형태인데, 이러한 시스템의 주요 장점은 첫째, 일사량에 따라 각각의 PCS가 모두 정격에서 운전하도록 하여 변환효율을 개선할 수 있다는 점과 둘째, 태양광 어레이의 용량 확장에 따른 PCS 장치의 용이한 확장성 그리고 셋째, 연결되어 있는 다수의 PCS 중 하나의 태양광 PCS가 고장으로 인하여 유지 및 보수가 필요할 때에도 그 외의 다른 정상적인 태양광 PCS는 지속적인 발전이 가능한 장점 등을 갖는다. 본 논문에서는 태양광 어레이의 출력을 공유하는 병렬운전용 태양광 PCS의 구성에 대하여 연구하고, 그 병렬운전기법을 제시하여 이에 대한 타당성을 시뮬레이션으로 검증하고자 한다.

  • PDF

고장전류의 누적 에너지를 이용한 저압직류 배전계통의 고저항 지락고장 검출 알고리즘 개발 (Development of an Algorithm for Detecting High Impedance Fault in Low Voltage DC Distribution System using Accumulated Energy of Fault Current)

  • 오윤식;노철호;김두웅;권기현;한준;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권5호
    • /
    • pp.71-79
    • /
    • 2015
  • Recently, new Low Voltage DC (LVDC) power distribution systems have been constantly researched as uses of DC in end-user equipment are increased. As in conventional AC distribution system, High Impedance Fault (HIF) which may cause a failure of protective relay can occur in LVDC distribution system as well. It, however, is hard to be detected since change in magnitude of current due to the fault is too small to detect the fault by the protective relay using overcurrent element. In order to solve the problem, this paper presents an algorithm for detecting HIF using accumulated energy in LVDC distribution system. Wavelet Singular Value Decomposition (WSVD) is used to extract abnormal high frequency components from fault current and accumulated energy of high frequency components is considered as the element to detect the fault. LVDC distribution system including AC/DC and DC/DC converter is modeled to verify the proposed algorithm using ElectroMagnetic Transient Program (EMTP) software. Simulation results considering various conditions show that the proposed algorithm can be utilized to effectively detect HIF.

새로운 영전압 스위칭 이단방식의 고역률 컨버터 (Novel Two Stage AC-to-DC Converter with Single Switched Zero Voltage Transition Boost Pre-Regulator using DC-Linked Energy Feedback)

  • 노정욱;문건우;정영석;윤명중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.385-387
    • /
    • 1996
  • A novel two stage soft-switching ac-to-dc convener with power factor correction is proposed. The proposed convener provides zero-voltage-switching (ZVS) condition to main switch of boost pre-regulator without auxiliary switch. Comparing to the conventional two stage approach(ZVS-PWM boost rectifier followed by off-line ZVS dc-dc step down converter), the proposed approach is simple and reducing EMI noise problem. A new simple DC-linked energy feedback circuit provides zero-voltage-switching condition to boost pre-regulator without imposing additional voltage and current stresses and loss of PWM capability. Operational principle, analysis, control of the proposed converter together with the simulation results of 1KW prototype are presented.

  • PDF