Design and Control of DC/AC Converters in Parallel with Diode Rectifiers for Regenerative Applications

  • Gao, Zhigang;Li, Rui;Lu, Qi
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1071-1087
    • /
    • 2017
  • This paper introduces a DC/AC converter, which can be connected in parallel with a diode rectifier for regenerative applications. The DC/AC converter is supposed to transmit regenerative energy to the power grid when a motor is braking. Isolation transformers are not needed in the topology, which can reduce the size and cost. An analysis of the zero-order current existing in the system is carried out. In addition, algorithms to minimize the zero-order current, control the power factor and keep the DC bus voltage stable are discussed. A 55kW industrial prototype is built to verify the proposed analysis and control strategies.

이터 초전도자석 전원공급장치 현장 설치현황 및 시운전 계획 (KO AC/DC Converter System Installation Status and Commissioning Plan at ITER Site)

  • 송인호;오종석
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.397-401
    • /
    • 2022
  • The construction of the ITER tokamak machine is ongoing at a 77% process rate to achieve the first plasma in 2025. The 18 sets of power supply systems comprising 400 MVA thyristor AC/DC converters for the superconducting magnets supplied by Korea (KO) are being installed with other systems, such as PF converters (China), DC busbars (Russia), and cooling water systems (India), in two buildings (Europe). The system interfaces have been defined during the design stage, and the systems have been manufactured. However, during the on-site installation work, several installation and integration issues emerged due to the manufacturing tolerance and design mistakes. To continue the installation and testing, the engineers of each system resolved the interface issues, planned the commissioning, and integrated the test plan. This paper describes the on-site installation status and issues and the commissioning plan of KO AC/DC converters.

AC and DC Microgrids: A Review on Protection Issues and Approaches

  • Mirsaeidi, Sohrab;Dong, Xinzhou;Shi, Shenxing;Wang, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2089-2098
    • /
    • 2017
  • Microgrid is a convenient, reliable, and eco-friendly approach for the integration of Distributed Generation (DG) sources into the utility power systems. To date, AC microgrids have been the most common architecture, but DC microgrids are gaining an increasing interest owing to the provision of numerous benefits in comparison with AC ones. These benefits encompass higher reliability, power quality and transmission capacity, non-complex control as well as direct connection to some DG sources, loads and Energy Storage Systems (ESSs). In this paper, main challenges and available approaches for the protection of AC and DC microgrids are discussed. After description, analysis and classification of the existing schemes, some research directions including coordination between AC and DC protective devices as well as development of combined control and protection schemes for the realization of future hybrid AC/DC microgrids are pointed out.

Carrier Based Common Mode Voltage Reduction Techniques in Neutral Point Clamped Inverter Based AC-DC-AC Drive System

  • Ojha, Amit;Chaturvedi, Pradyumn;Mittal, Arvind;Jain, Shailendra
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.142-152
    • /
    • 2016
  • Common mode voltage (CMV) generation is a major problem in switching power converter fed induction motor drive systems. CMV is the zero sequence voltage generated due to the switching action of power converters. Even a small magnitude of CMV with a high rate of change may circulate large bearing currents which may damage a machine's bearings and shorten its life. There are several methods of controlling CMV. This paper presents 3-level sinusoidal pulse width modulation based techniques to control the magnitude and rate of change of CMV in multilevel AC-DC-AC drive systems. Simulation and experimental investigations have been presented to validate the performance of proposed technique to control CMV in 3-level neutral point clamped inverter based AC-DC-AC system.

Power Flow Study of Low-Voltage DC Micro-Grid and Control of Energy Storage System in the Grid

  • Kim, Dong-Eok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.549-558
    • /
    • 2017
  • DC distribution has several differences compared to AC distribution. DC distribution has a higher efficiency than AC distribution when distributing electricity at the same voltage level. Accordingly, power can be transferred further with low-voltage DC. In addition, power flow in a DC grid system is produced by only a voltage difference in magnitude. Owing to these differences, operation of a DC grid system significantly differs from that of an AC system. In this paper, the power flow problem in a bipolar-type DC grid with unbalanced load conditions is organized and solved. Control strategy of energy storage system on a slow time scale with power references obtained by solving an optimization problem regarding the DC grid is then proposed. The proposed strategy is verified with computer simulations.

AC PDP 구동회로의 에너지 회생에 관한 연구 (A Study on the Energy Recovery of AC PDP Driving Circuits)

  • 정우창;강경우;유종걸;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.267-270
    • /
    • 2003
  • In this paper, a new energy recovery circuit for AC PDP(Plasma Display Panel) is proposed to decrease a sustain voltage and voltage stress on switching elements. In the proposed circuit, two auxiliary capacitors are connected directly to the power source through switching elements and inductors when ground potential is supplied to the panel. Therefore, the voltage across auxiliary capacitors can be increased by turns over the half of the source voltage. Because the intrinsic capacitance of PDP is charged sufficiently from the auxiliary capacitors, the level of sustain voltage and the voltage stress on the switching devices are decreased. To verify the validity of the proposed energy recovery circuit, computer simulations using PSpice program are carried out.

  • PDF

AC Plasma Display Panel구동 장치의 고효율 전력 회수 회로에 관한 연구 (A Study on High Efficient Energy Recovery Circuit for AC Plasma Display Panel Drive)

  • 윤원식;강필순;박한웅;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.442-445
    • /
    • 2001
  • The sustaining driver for color ac plasma display panel should provide alternating high voltage pulses and recover the energy discharged from the intrinsic capacitance between the scanning and sustaining electrodes inside the panel. In this paper, a novel efficient energy recovery circuit employing boost-up function is proposed to achieve a faster rise-time and in order to obtain a stable sustain voltage. The principle of operation, features, and simulated results are illustrated and verified on an equivalent capacitance, which is equals In that of 40-inch-panel, 200 (kHz).

  • PDF

Z-Source Converter with Maximum Boost Voltage Gain

  • Nguyen, Minh-Khai;Jung, Young-Gook;Lim, Young-Cheol
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.112-114
    • /
    • 2008
  • This paper proposes a new two-stage Z-source converter (TSZC). The purpose of the proposed system is to obtain the ac voltage with a maximum boost voltage for fuel cell applications as a renewable energy source. In order to provide a continuous current path, a switching strategy for the dc-ac ZSI and ac-ac ZSC of the proposed system was used. The operation principle, analysis and simulation results of 1.2 kW fuel cell stack were also presented.

  • PDF

재활용 AC4A 알루미늄 합금의 충격 및 피로 특성에 미치는 (Ti-B), Sr 첨가제의 영향 (Effect of (Ti-B) and Sr Additives on Impact and Fatigue Properties of Recycled AC4A Aluminum Casting Alloy)

  • 오승환;김헌주
    • 한국주조공학회지
    • /
    • 제39권4호
    • /
    • pp.61-74
    • /
    • 2019
  • The effects of Sr and (Ti-B) additives on the impact and fatigue properties of recycled (35% scrap content) AC4A aluminum alloy are investigated here. The acicular morphology of the eutectic Si phase of as-cast specimens was converted to the fibrous one with Sr additives. The grain size of the α-solid solution decreased by the addition of (Ti-B) additives. The crack initiation energy (Ei) of the impact absorption energy decreased due to the incorporation of an oxide film and inclusions depending on the scrap used. The modification of the eutectic Si morphology by Sr additives is considered as the main factor of the increase of the average impact absorption energy (Et). The addition of (Ti-B) additives contributed to an increase in the occurrence of crack deflections due to the refining of α-Al grains, resulting in improved fatigue properties.

Finite Control Set Model Predictive Control of AC/DC Matrix Converter for Grid-Connected Battery Energy Storage Application

  • Feng, Bo;Lin, Hua
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1006-1017
    • /
    • 2015
  • This paper presents a finite control set model predictive control (FCS-MPC) strategy for the AC/DC matrix converter used in grid-connected battery energy storage system (BESS). First, to control the grid current properly, the DC current is also included in the cost function because of input and output direct coupling. The DC current reference is generated based on the dynamic relationship of the two currents, so the grid current gains improved transient state performance. Furthermore, the steady state error is reduced by adding a closed-loop. Second, a Luenberger observer is adopted to detect the AC input voltage instead of sensors, so the cost is reduced and the reliability can be enhanced. Third, a switching state pre-selection method that only needs to evaluate half of the active switching states is presented, with the advantages of shorter calculation time, no high dv/dt at the DC terminal, and less switching loss. The robustness under grid voltage distortion and parameter sensibility are discussed as well. Simulation and experimental results confirm the good performance of the proposed scheme for battery charging and discharging control.