• Title/Summary/Keyword: AC coupling

Search Result 144, Processing Time 0.025 seconds

A Study on Implementing of AC-3 Decoding Algorithm Software (AC-3 Decoding Algorithm Software 구현에 관한 연구)

  • 이건욱;박인규
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1215-1218
    • /
    • 1998
  • 본 논문은 Digital Audio Compression(AC-3) Standard 인 A-52를 기반으로 하였으며 Borland C++3.1 Compiler를 사용하여 AC-3 Decoding Algorithm 구현하였다. Input Stream은 DVD VOB File에서 AC-3 Stream만을 분리하여 사용하며 최종 출력은 16 Bit PCM File이다. AC-3의 Frame구조는 Synchronization Information, Bit Stream Information, Audio Block, Auxiliary Data, Error Check로 구성된다. Aduio Block 은 모두 6개의 Block으로 나뉘어져 있다. BSI와 Side Information을 참조하여 Exponent를 추출하여 Exponent Strategy에 따라 Exponent를 복원한다. 복원된 Exponent 정보를 이용하여 Bit Allocation을 수행하여 각각의 Mantissa에 할당된 Bit수를 계산하고 Stream으로부터 Mantissa를 추출한다. Coupling Parameter를 참조하ㅕ Coupling Channel을 Original Channel로 복원시킨다. Stereo Mode에 대해서는 Rematrixing을 수행한다. Dynamic Range는 Mantissa와 Exponent의 Magnitude를 바꾸는 것으로 선택적으로 사용할 수 있다. Mantissa와 Exponent를 결합하여 Floating Point coefficient로 만든 후 Inverse Transform을 수행하면 PCM Data를 얻을 수 있다. PC에서 듣기 위해서는 Multi Channel을 Stereo나 Mono로 Downmix를 수행한다. 이렇게 만들어진 PCM data는 PCM Data를 재생하는 프로그램으로 재생할 수 있다.

  • PDF

Analysis of error factors of the Fall-of-potential test method in measurements of grounding impedance (전위강하법에 의한 접지임피던스 측정 시 오차요인 분석)

  • Jeon, Byung-Wook;Lee, Su-Bong;Jung, Dong-Cheol;Lee, Bok-Hee;Ahn, Chang-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.313-316
    • /
    • 2008
  • This paper presents the error factors of Fall-of-potential test method used in measurements of the grounding-system impedance. This test methods inherently can introduce two possible errors in the measurements of grounding-system impedance: (1) ground mutual resistance due to current flow through ground from the ground electrode to the current probe, (2) ac mutual coupling between the current test lead and the potential test lead. The errors of ground mutual resistances and ac mutual coupling are expressed by the equation in calculating grounding impedance. These equations were calculated by Matlab that is commercial tool using mathematical calculation. The results of calculation were applied to correct grounding impedance.

  • PDF

Characteristic of Planar Spiral Inductor for Wireless Signal Transmission based on AC Coupling (AC 커플링 기반 무선 신호 전송을 위한 평면 나선형 인덕터의 특성)

  • Kim, Jae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4126-4130
    • /
    • 2012
  • In this paper, we proposed planar spiral inductors based on AC coupling for high-frequency wireless signal transmission. Design and characteristics of various structures of the inductor were analyzed. Capacitance between the inductors can be reduced by positioning two thin-film inductors in parallel. So two structures were proposed. First structure is inter-diagonal structure. This structure was made not to overlap the wire part of the paralleled two inductors. Second structure is On-chip type structure that the two thin-film inductors were in parallel but located on diagonal line not to face each other. The resonance in this structure was reduced from twice to once by increasing horizontal distance between the two thin-film inductors, because the capacitance effect between the two thin-film inductors decreases when the distance between the two inductors increases.

AC Electrical Coupling of Monolithic 3D Inverter Consisting of Junctionless FET (Junctionless FET로 구성된 적층형 3차원 인버터의 AC 특성에 대한 연구)

  • Kim, Kyung-won;Ahn, Tae-Jun;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.529-530
    • /
    • 2017
  • Electrical coupling of monolithic 3D inverter(M3D-INV) consisting of Junctionless FET(JLFET) was investigated. Depending on the thickness of Inter Layer Dielectirc (ILD) between top and bottom JLFETs, $N_{gate}-N_{gate}$ capacitance and transconductance $g_m$ are changed by the gate voltage of bottom JLFET. Therefore, when using a stacked structure with the ILD below tens nm, AC electrical coupling between two transistors in M3D-INV should be considered.

  • PDF

Design and Fabrication of a Surge Generator with Coupling/Decoupling Networks (커플링/디커플링 네트워크 내장 서지발생장치의 설계 및 제작)

  • Kim, Nam-Hoon;Kang, Tae-Ho;Shin, Han-Sin;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.2
    • /
    • pp.130-134
    • /
    • 2020
  • Metal oxide varistors (MOVs) protect circuits and devices from transient overvoltages in electric power systems. However, a MOV continuously deteriorates owing to manufacturing defects or repetitive protective operations from transient overvoltages. A deteriorated MOV may result in a short circuit or a line-ground accident. Previous studies focused on the analysis of deterioration mechanisms and condition diagnosis techniques for MOVs owing to their recent growth of use. An accelerated deterioration experiment under the same conditions in which a MOV operates is essential. In this study, we designed and fabricated a surge generator that can apply a surge current to a MOV connected to AC mains. The coupling network operates at a low impedance against the surge current from the surge generator and transfers the surge current to the MOV under test. It also acts as a high impedance against AC mains for the AC voltage not to be applied to the surge generator. The decoupling network operates at a high impedance against the surge current and blocks the surge current from AC mains. It also acts as a low impedance against AC mains for the AC voltage to be applied to the MOV under test. The prototype surge generator can apply the 8/20 us up to 15 kA on AC voltages in the approximate range of 110~450 V, and it fully operates on a LabVIEW-based program.

Deadbeat Direct Active and Reactive Power Control of Three-phase PWM AC/DC Converters

  • Gandomkar, Ali;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1634-1641
    • /
    • 2018
  • This study focuses on a high-performance direct active and reactive power controller design that is successfully applicable to three-phase pulse width modulation (PWM) AC/DC converters used in renewable distributed energy generation systems. The proposed controller can overcome the sluggish transient dynamic response of conventional controllers to rapid power command changes. Desired active and reactive powers can be thoroughly obtained at the end of each PWM period through a deadbeat solution. The proposed controller achieves an exact nonlinear cross-coupling decoupling of system power without using a predefined switching table or bang/bang hysteresis control. A graphical and analytical analysis that naturally leads to a control voltage vector selection is provided to confirm the finding. The proposed control strategy is evaluated on a 3 kW PWM AC/DC converter in the simulation and experiment.

A Study on a Performance Analysis of Direct-Conversion Receiver Using AC-Coupling Method in Additive White Gaussian Noise Channel Environment (AWGN 채널환경에서 AC-Coupling기법을 이용한 Direct-Conversion 수신기의 성능분석에 관한 연구)

  • 박성진;김칠성;성태경;조형래
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.205-209
    • /
    • 2000
  • Modem wireless communication equipments provides various multimedia and aims at the development of low-power, minimum size and weight, and low-cost implimentations. Because of the heterodyne architecture which was invented many decades ago in the wireless communication system using too many components, it was difficult to make it small, compact and On-Chip so it does not proper for future communication. That gives rise a new developing architecture, so called, Direct Conversion. Because The Direct Conversion down-converts the wireless frequency band to baseband directly, it does not need using additive components and has a merit of reduction in power dissipation. We describes the Direct Conversion architecture and DC-Offset, which must be solved, theorectically and predicts system performance enhancement when adopt the AC-Coupling method.

  • PDF

A Study of Distortion of Waveform in AC PDP

  • Kim, Min-Seok;Lim, Hun-Yong;Lee, Jeong-Hae;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.561-563
    • /
    • 2004
  • In this paper, distortion of waveform in AC-PDP module has been studied. The propagation losses and interference due to coupling between the electrodes can be considered as the causes for waveform distortion. The distorted waveform has been obtained from the calculated propagation losses. The coupling between the electrodes has been measured using a proper experimental setup. This distorted waveform could account for underfiring problem in AC PDP module.

  • PDF

$S^4$-PFC AC/DC Converter To Reduce DC Bus Stress With Coupling Inductor ($S^4$-PFC에서 커플링 인덕터를 이용하여 DC 버스 스트레스를 저감시킨 AC/DC 컨버터)

  • Lee, Jang-Hyun;Kim, Tai-Woong;Lee, Sung-Palk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2515-2517
    • /
    • 1999
  • In this paper we analysis DC bus voltage stress at high line voltage and light load in $S^4$-PFC Isolated AC/DC converter with DC bus voltage feedback using coupling in transformer. In this converter, the principle of operation and the practical problems in the design are considered. Simulation and experimental results are presented to verify the operation and performance of the $S^4$-PFC converter with DC bus voltage feedback. Experimental sets are performed in the conditions; switching frequency 100 kHz, output of 5 V, 60W, and universal line input voltage.

  • PDF

Electrical properties of XLPE/SXLPE blends as a function of silane coupling agent contents (실란 계면 결합제 함량에 따른 XLPE/SXLPE 블렌드의 전기적 성질)

  • Ko, Jung-Woo;Suh, Kwang-S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.33-36
    • /
    • 2000
  • Electrical properties of Crosslinked polyethylene/silane crosslinked polyethylene (XLPE/SXLPE) blends were studied. Silane coupling agents of various contents were added to blends and their water tree and electrical breakdown characteristics were investigated. The water tree length of XLPE/SXLPE were increased by the addition of silane coupling agents except the case of SXLPE 10 % containing coupling agents of 0.5, 1.0 phr. AC breadown strength slightly increased by the addition of coupling agents to XLPE/SXLPE blends in cases of SXLPE 20 % containing coupling agents of 2.0 phr and SXLPE 50 %. The tendency of effects on water tree and breakdown characteristics was inverse.

  • PDF