• Title/Summary/Keyword: AC Power Source

Search Result 524, Processing Time 0.025 seconds

1KW Converter for Fuel cell using unregulated DC-DC Converter (고정시비율 DC-DC 컨버터를 사용한 1KW급 연료전지용 컨버터)

  • Jung, Yong-Min;Yoo, Ho-Won;Lim, Seung-Beom;Lee, Kyung-In;Oh, Eun-Tae;Hong, Soon-Chan;Lee, Jun-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.373-375
    • /
    • 2008
  • Studying for environmentally-friendly and efficient energy source is now actively under way on because problems like environmental pollution and exhaust of natural resources are in issue. Pure Cell which is an alternative energy source has low voltage and high current characteristic, therefore boost up voltage converter and DC-AC converter is required to use as a common power source. In this paper, DC-DC converter which has high efficient and high power density is proposed and verified by experimental result.

  • PDF

Analysis for dc Boost Control System Using Z-Source Inverter

  • Tran, Quang-Vinh;Chun, Tae-Won;Lee, Hong-Hee;Ahn, Jung-Ryol
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.647-650
    • /
    • 2005
  • The paper aims on an analysis for dc boost control using Z-source inverter. The modified space vector PWM method is used for controlling both the dc boost and ac output controls in the Z-source inverter. The capacitor voltage and the voltage stress of device with both the shoot-through time and modulation index are analyzed considering the zero state time of inverter. The theoretical analysis is verified with the simulation studies and experiments with 32-bit DSP.

  • PDF

Study on Grid-Connected Photovoltaic System using Current-Source Inverter (전류형 인버터를 이용한 계통 연계형 태양광 발전 시스템에 관한 연구)

  • Lim, J.M.;Park, S.J.;Lee, S.H.;Moon, C.J.;Choi, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.677-681
    • /
    • 2005
  • This Paper presents a 6 pulse shift operation control mode of current-source-inverter to make improvement of efficiency and to reduce the frequency of inverter switching for photovoltaic generation system using PWM current-source-inverter. This system is connected solar cell energy directly without using a storage cell. The proposed circuit can maintain maximum voltage of photovoltaic generation of take advantage of six Buck-Boost converter and a full-bridge inverter determines the polarity of AC output. That is controlled by using digital signal processor TMS320F2812 for operation about a 6 pulse shift operation control of current-source-inverter, and it is verified through the experimental results.

  • PDF

A Grid Current-Controlling Shunt Active Power Filter

  • Tumbelaka, Hanny H.;Borle, Lawrence J.;Nayar, Chemmangot V.;Lee, Seong-Ryong
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.365-376
    • /
    • 2009
  • In this paper, the implementation of a three-phase shunt active power filter is presented. The filter is essentially three independent single-phase current-controlled voltage source inverters (CC-VSI) with a common DC bus. The CC- VSI is operated to directly control the AC grid current to be sinusoidal and in phase with the grid voltage without detecting the load currents. The APF consists of a current control loop, which shapes the grid currents to be sinusoidal and a voltage control loop, which regulates the active power balance of the system. The experimental results indicate that the active filter is able to handle predominantly the harmonics, as well as the unbalance and reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical.

Current-Fed Reactive Power Compensator Using Delta Modulation Technique (델터 변조 방식을 이용한 전류형 무효전력 보상장치)

  • 백형래;김한성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.3
    • /
    • pp.244-252
    • /
    • 1992
  • This paper describes a reactive power compensator using current-source delta modulation converter, which compensates the reactive power in the ac sides of 3-phase rectifier. In the conventional current control methods for the current-type reactive power compensators, it is usual to compare the reactive reference current signal with the triangular wave and hence to generate the ON-OFF signals for the reactive power compensator. To improve the response as well as the control capability, the delta modulated current control technique is used in this paper. As a result, the input power factor is improved close to unity and both simulation and experimental results show good compensating performances.

  • PDF

The Study of Single Phase Source Stability consider for The DSC Cell's Operation Character by Controlled Feed-back Circuit

  • Lee, Hee-Chang
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.4
    • /
    • pp.170-173
    • /
    • 2006
  • Recently, with increasing efficiency of DSC (photo-electrochemical using a nano-particle), The Performance of DSC solar generation system also needs improvement. The approach consists of a Fly-back DC-DC (transfer ratio 1:10) converter to boost the DSC cell voltage to 300VDC. The four switch (MOSFET) inverter is employed to produce 220V, 60Hz AC outputs. High performance, easy manufacturability, lower component count., safety and cost are addressed. Protection and diagnostic features form an important part of the design. Another highlight of the proposed design is the control strategy, which allows the inverter to adapt to the: requirements of the load as well as the power source. A unique aspect of the design is the use of the DSP TMS320LF2406 to control the inverter by current and voltage feed-back. Efficient and smooth control of the: power drawn from the DSC Cell is achieved by controlling the front end DC-DC converter in current mode.

A Study on the phase angle detection of power source for PWM converter based on PLL method (PLL기법에 기반한 PWM 컨버터 전원 위상각 검출에 관한 연구)

  • Choi Cheol;Lee Sang-Hun;Kim Cheol-U
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.284-288
    • /
    • 2005
  • This paper proposes the direct detection method of phase angle for the power source, which is based on the PLL method. The proposed method using a bidirectional photo-coupler is used to directly detect the zero crossing of phase voltage and calculate the angular frequency in the controller based on a M/T algorithm. Through the method, the additional installation space in the traditional method using a potential transformer can be minimized and it can be easy to design. The paper presents straightforward schematic circuits, design and experimental results.

  • PDF

The Inverter Control Method Using The Voltage Sag Compensation algorithm (순간전압강하 보상 알고리즘을 이용한 인버터 제어에 관한 연구)

  • Yun, Hong-Min;Bae, Jin-Yong;Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.62-67
    • /
    • 2012
  • In this paper general purpose voltage source inverter drives are equipped with an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag control algorithm, experimental results are presented.

The Converter Topology with full Bridge Inverter for the Switched Reluctance Motor Drives (단상 풀 브리지 인버터를 이용한 SRM 컨버터 토폴로지)

  • Jang, Do-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.8
    • /
    • pp.475-481
    • /
    • 2002
  • In this paper the new converter topology using single-Phase full bridge inverter for the switched reluctance motor drives is proposed. The proposed SRM drives are supplied by the AC pulse voltage source, while the conventional drives are supplied by the DC voltage source. Speed of the SRM is controlled by adjusting the frequency and the multitude of output current of inverter. The SRM using the proposed converter reduces the switching loss and the machine core loss, and has ability to pre-regulate the input voltage. The total number of power switches become fewer than another topology as a number of stator poles becomes more. Power circuit of an inverter is simpler and its volume is smaller because the module device involving several switches is used as an inverter.

Control of The D-STATCON Using Multilevel Voltage Source Inverters (MULTILEVEL 전압형 인버터들을 사용한 D-STATCON의 제어)

  • Min, Wan-Ki;Min, Jun-Ki;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1925-1927
    • /
    • 1998
  • D-STATCON using the multilevel voltage source inverters is presented for voltage regulation and reactive power compensation in distribution system. This cascade M-level inverter consists of (M-1)/2 single phase full bridge inverter(FBI). This multilevel inverter is a natural fit to the flexible ac transmission systems(FACTS) including STATCON, SVC, series compensation and phase shifting, It can solve the problems of conventional transformer-based multipulse inverters and multilevel diode-clamped inverters. From the simulation results, the superiority of D-STATCON with cascade multilevel inverter is shown for high power application.

  • PDF