• Title/Summary/Keyword: AC Power

Search Result 3,405, Processing Time 0.027 seconds

Analysis of IoT Security in Wi-Fi 6 (Wi-Fi 6 환경에서의 IoT 보안 분석)

  • Kim, HyunHo;Song, JongGun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.1
    • /
    • pp.38-44
    • /
    • 2021
  • Wi-Fi provides some low-power connection solutions that other Bluetooth cannot provide, and at the same time brings many benefits. First, there is a potentially higher data rate: it can reach 230mbps. Wi-Fi coverage is also wider than competitors, and its operating frequency is also 5GHz, which is much less congested than 2.4GHz. Finally, it also supports IP networks, which is important if you want to send data to the cloud without complexity. The 802.11ac standard of the previous generation still accounts for most shipments (80.9%) and revenue (76.2%). However, there is a limit to accepting IoT devices that will continue to increase significantly in the future. To solve this problem, the new Wi-Fi 6 standard is expected to be the solution (IEEE 802.11ax) which is quickly becoming the main driving force of the wireless local area network (WLAN) market. According to IDC market research analysts, in the first quarter of 2020, independent access points (APs) supported by Wi-Fi 6 accounted for 11.8% of shipments, but 21.8% of revenue. In this paper, we have compared and analyzed the IoT connectivity, QoS, and security requirements of devices using Wi-Fi 6 network.

Low cost 2.4-GHz VCO design in 0.18-㎛ Mixed-signal CMOS Process for WSN applications (저 가격 0.18-㎛ 혼성신호 CMOS공정에 기반한 WSN용 2.4-GHz 밴드 VCO설계)

  • Jhon, Heesauk;An, Chang-Ho;Jung, Youngho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.325-328
    • /
    • 2020
  • This paper demonstrated a voltage-controlled oscillator (VCO) using cost-effective (1-poly 6-metal) mixed signal standard CMOS process. To have the high-quality factor inductor in LC resonator with thin metal thickness, patterned-ground shields (PGS) was adopted under the spiral to effectively reduce the ac current of low resistive Si substrate. And, because of thin top-metal compared with that of RF option (2 ㎛), we make electrically connect between the top metal (M6) and the next metal (M5) by great number of via array along the metal traces. The circuit operated from 2.48 GHz to 2.62 GHz tuned by accumulation-mode varactor device. And the measured phase noise of LC VCO has -123.7 dBc/Hz at 1MHz offset at 2.62 GHz and the dc-power consumption shows 2.07 mW with 1.8V supply voltage, respectively.

Thermal Instability of Fluid in a Slot between Two Vertical Permeable Walls (두개의 수직 다공성 벽면을 가진 좁은 간격에서의 유체의 열적 불안정성)

  • Sohn, Dong-Yun;Yoo, Jung-Yul;Lee, Taik-Sik
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.4
    • /
    • pp.215-222
    • /
    • 1984
  • An analytical study on the thermal instability of fluid in a vertical solt between two permeable walls has been carried out using fast converging power series solution method. For given values of prandtl number Pr and permeability paramter ${\sigma}$, the critical Grashof number $Gr_c$ and the critical wave number ac are found as eigenvalues of the problem formulated by the stability equations and the appropriate boundary conditions which are derived on the basis of linear stability theory. In the case of ${\sigma}\;>\;10^4$, the results approach those of solid boundary case, but in the case of ${\sigma}\;<\;10^3$, the decrease of $Gr_c$ and $a_c$become more prominent. In other words, the permeable walls cause the flow to be more unstable than the solid walls. This is considered to be due to the slip of the fluid on the wail, which decrease the friction force.

  • PDF

ENHANCING TIG WELD PERFORMANCE THROUGH FLUX APPLICATION ATIG AND FBTIG PROCESSES

  • Marya, S.
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.70-75
    • /
    • 2002
  • The penetration potential of TIG welding in one single run is limited, though the process itself generates high quality welds with good weld cosmetics. This is one of the main reasons, which has contributed to its development in high duty applications such as those encountered in aeronautical, aerospace, nuclear & power plant applications. For these applications, stainless steels, titanium k nickel based alloys are most often used. As these materials remain very sensible to weld heat input k atmospheric pollution, stringent processing conditions are imposed. For example welding of titanium alloys requires argon shielding of weld zone and for 5 mm thick plates multi-pass runs & filler additions are required. This multi-run operation not only raises the welding cost, but also increases defect risks. In recent years, extensive interest has been raised by the possibility to increase weld penetrations through flux applications & the process is designated ATIG-activated TIG, or FBTIG-flux bounded TIG. The improved welding performance of such flux assisted TIG is related to arc constriction and surface tension effects on weld pool. The research work by authors has lead to the formulation of welding fluxes for stainless steels k titanium alloys with TIG Process. These fluxes are now commercialized & some applications in industry have already been carried out. FBTIG for aluminum has been proposed with silica application for AC mode TIG welding. The paper highlights the fundamentals of flux role in TIG welding and illustrates some industrial applications.

  • PDF

A Study on Technology Commercialization of Indoor Floor Advertising Lighting Devices Applicable to Advertisements and Disaster Situations (광고 및 재난상황에 적용 가능한 실내용 바닥광고 조명장치의 기술사업화 방안 연구)

  • Kwang-Soo Kim;Woon-Seek Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.32-40
    • /
    • 2023
  • Recently, there are some outdoor floor advertising lighting devices as one of the active marketing methods. However, for outdoor use, there are many restrictions due to the Outdoor Advertisement Act, according to requiring high-output heat generation, waterproofing, and AC power, etc. The purpose of this study is to develop a Duo Light product optimized for indoor use through publicity and information guidance in normal times and automatic evacuation route guidance display in case of disaster, in conjunction with disaster safety. To that end, patent search and patent association analyses were conducted, and a comparative analysis with commercial products was conducted as a case study. In addition, prototypes were designed and produced through the review of operation principles, where field environment surveys and self-tests were conducted. Also, technology roadmaps were presented by preparing plans for expandability and advancement of products. For the analysis of technology commercialization, the feasibility of technology commercialization was examined through the analysis of Jolly's Model and Lean Canvas Model. The results of this study will be able to contribute to minimize human damage through the effective response to disasters, which can increase the effect of indoor advertising by using the proposed indoor floor advertising lighting device in advertising and disaster situations.

Effect of CORC former and striation on magnetization loss

  • Myeonghee Lee;Byeong-Joo Kim;Miyeon Yoon;Kyeongdal Choi;Ji-Kwang Lee;Woo-Seok Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.45-49
    • /
    • 2023
  • CORC, which is being studied as one of the conductors for large currents, is manufactured by symmetrically arranging several strands of high-temperature superconducting wires on a cylindrical former. It allows current to flow evenly between wires and has the advantage of being manufactured in a multi-layer structure to increase current capacity. In order to apply CORC to AC power devices, it is necessary to review the material of the former, which is the frame around which the superconducting wire is wound. In the case of metal formers, they are difficult to apply because eddy currents are generated in the former, and they do not have the flexibility to be manufactured into coils by winding them with CORC. In this paper, we compare and analyze the magnetization loss caused by an external alternating magnetic field of Litz wire, which is being considered as a former material for CORC, with the results from formers made of other materials. In addition, we experimentally examine the effect of reducing magnetization loss due to an external magnetic field in CORC using a split wire made by dividing a high-temperature superconducting wire into two using an etching method, and in CORC made with a non-split wire.

The Role of Neutrophils and Epidermal Growth Factor Receptors in Lipopolysaccharide-Induced Mucus Hypersecretion (리포다당질 (lipopolysaccharide)에 의한 기관지 점액 생성 기전에서 호중구와 상피세포 성장인자 수용체 (epidermal growth factor receptor)의 역할)

  • Bak, Sang Myeon;Park, Soo Yeon;Hur, Gyu Young;Lee, Seung Heon;Kim, Je Hyeong;Lee, Sang Yeub;Shin, Chol;Shim, Jae Jeong;In, Kwang Ho;Kang, Kyung Ho;Yoo, Se Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.1
    • /
    • pp.80-90
    • /
    • 2003
  • Background : Goblet cell hyperplasia is a critical pathological feature in hypersecretory diseases of the airways. A bacterial infection of the lung is also known to induce inflammatory responses, which can lead to the overproduction of mucus. Recently, mucin synthesis in the airways has been reported to be regulated by neutrophilic inflammation-induced epidermal growth factor receptor (EGFR) expression and activation. In addition, it was reported that migration of the activated neutrophils is dependent on the matrix metalloproteinases (MMPs), especially MMP-9. In this study, bacterial lipopolysaccharide (LPS)-induced goblet cell hyperplasia and mucus hypersecretion by EGFR cascade, resulting from the MMPs-dependent neutrophilic inflammation were investigated in the rat airways. Methods : Pathogen-free Sprague-Dawley rats were studied in vivo. Various concentrations of LPS were instilled into the trachea in $300{\mu}{\ell}$ PBS (LPS group). Sterile PBS ($300{\mu}{\ell}$) was instilled into the trachea of the control animals (control group). The airways were examined on different days after instilling LPS. For an examination of the relationship between the LPS-induced goblet cell hyperplasia and MMPs, the animals were pretreated 3 days prior to the LPS instillation and daily thereafter with the matrix metalloproteinase inhibitor (MMPI; 20 mg/Kg/day of CMT-3; Collagenex Pharmaceuticals, USA). The neutrophilic infiltration was quantified as a number in five high power fields (HPF). The alcian blue/periodic acid-Schiff (AB/PAS) stain were performed for the mucus glycoconjugates and the immunohistochemical stains were performed for MUC5AC, EGFR and MMP-9. Their expressions were quantified by an image analysis program and were expressed by the percentage of the total bronchial epithelial area. Results : The instillation of LPS induced AB/PAS and MUC5AC staining in the airway epithelium in a time- and dose-dependent manner. Treatment with the MMPI prevented the LPS-induced goblet cell hyperplasia significantly. The instillation of LPS into the trachea induced also EGFR expression in the airway epithelium. The control airway epithelium contained few leukocytes, but the intratracheal instillation of LPS resulted in a neutrophilic recruitment. A pretreatment with MMPI prevented neutrophilic recruitment, EGFR expression, and goblet cell hyperplasia in the LPS-instilled airway epithelium. Conclusion : Matrix metalloproteinase is involved in LPS-induced mucus hypersecretion, resulting from a neutrophilic inflammation and EGFR cascade. These results suggest a potential therapeutic role of MMPI in the treatment of mucus hypersecretion that were associated with a bacterial infection of the airways.

A Study on SCOTT Transformer Protection Relay Malfunction Case and Improvement Methodology (스코트 변압기 보호계전기 오동작 사례분석 및 개선방안 고찰)

  • Lee, Jong-Hwa;Lho, Young-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.394-399
    • /
    • 2017
  • In Korean AC power railway substations, SCOTT winding transformers are under operation to have a single phase power supply together with a phase angle of $90^{\circ}$ on the secondary side of the main transformer. In the case of an internal fault of the transformer, the transformer protection relay should be cut off on the primary side, the transformer should be inoperative to the external fault of the transformer or to the normal train operation. Reducing the malfunction of the relay through an exact fault determination is very important for securing a stable power system and improving its reliability. The main transformers are protected using Buchholtz's relay and a differential relay as the internal fault detection devices, but there are some cases of the main transformer operation under the deactivation of this protection function due to a malfunction of the differential relay. In this paper, the characteristics of the SCOTT transformer and differential relay as well as the malfunctioning of the protection relays are presented. The modeling of the SCOTT transformer protection relay was accomplished by the power system analysis program and the Comtrade file from 'A substation', which was used as the input data for the fault wave, and the harmonics were analyzed to determine if the relay operates or not. In addition, an improvement plan for malfunctioning cases through wave form analysis is suggested.

IP Voltage Controller of Three-phase PWM Converter for Power Supply of Communication System (IP 제어기를 이용한 통신 전원용 3상 PWM 컨버터의 전압 제어)

  • Shin, Hee-Keun;Kim, Hag-Wone;Cho, Kwan-Yuhl;Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2722-2728
    • /
    • 2011
  • 3Phase PWM rectifier has become increasingly popular due to its capability of nearly sinusoidal waveform of the input current, and nearly unity power factor operation as a AC/DC rectifier of high capacity telecommunication power supply system. Generally, PI controller is used as a voltage controller of PWM rectifier and voltage controller must be designed to have low overshoot in transient state to get a reliability and stable operation. However, in the application of telecommunication in which load condition is varied very fast, the voltage controller must have a large bandwidth to reduce output voltage variation. The PI controller with large bandwidth arouse the excessive overshoot of the output voltage, and this large output voltage variation degrades the reliability of communication power of the three-phase PWM Rectifier. In this paper, new IP voltage controller for 3 phase PWM rectifier is proposed which has relatively low transient output voltage variation. The improved output characteristics of the transient state voltage responses of the starting and at load changes of the proposed voltage controller are proved by simulations and experiments.

Localization Development of Axial Fan for KM-SAM Multi-function radar (KM-SAM 다기능레이더용 축류형 송풍기 국산화 개발)

  • Lee, Gyeong-Chan;Choi, Young-Ho;Lee, Kowan-Woo;Seo, Dae-Sue
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.117-124
    • /
    • 2018
  • This paper describes the localization development of an axial fan for KM-SAM multi-function radar. The multi-function radar, which is constantly affected by the external environment, is a key instrument for detecting and tracking low and medium altitude threat targets. Operating this equipment smoothly requires a fan for controlling the internal temperature and humidity. Presently, all such fans are imported. To solve these problems, localization development research was proposed. The development of localization includes analysis of requirements through review of related technical reports such as original equipment and system equipment specification, prototype design, and verification of design requirement through performance test and environmental test. The study results are described. The blower consisted of an axial fan with guide vanes and the motor was designed to generate a maximum airflow of 970 CFM and a wind pressure of 4.8 IWG. Six prototypes were manufactured for performance evaluation. In addition, for reliable data acquisition, AC power supply, fan performance tester and data acquisition equipment were designed and tested. All prototypes were verified as having design requirements equal to or better than those of imports.