• Title/Summary/Keyword: AC Power

Search Result 3,405, Processing Time 0.03 seconds

Study of the Elimination of the Electrolytic Capacitors and Reduction of the Ripple Current on the Output Node in the One-Stage PFC Flyback Converter for the LED Lighting (LED 조명용 One-Stage PFC Flyback 컨버터에서의 출력단 리플 저감과 전해 커패시터의 제거에 관한 연구)

  • Jeon, Yong-Sung;Jin, Dal-Lae;La, Jae-Du;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1625-1633
    • /
    • 2012
  • In the lighting industry, a Lighting Emitting Diode (LED) is increasingly used because of many advantages and a eco-friendly product comparing with the conventional lighting. However, the LED lighting has to include various AC/DC converters because the direct current is used for the LED lighting. Among a lot of power converters, the flyback converter is widely used for the LED lighting and includes some electrolytic capacitors for the voltage regulation. But the electrolytic capacitor has shorter lifetime than the LED element. It makes the expected life-time of the converter having the electrolytic capacitor shorter than the LED element. This paper proposes the single-stage PFC flyback converter without electrolytic capacitors. To verify the performance of the proposed converter, simulated and experimental works were carried out.

Partial Discharge Characteristics in LLDPE-Natural Rubber Blends: Correlating Electrical Quantities with Surface Degradation

  • Aulia, Aulia;Ahmad, Mohd Hafizi;Abdul-Malek, Zulkurnain;Arief, Yanuar Z.;Lau, KwanYiew;Novizon, Novizon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.699-706
    • /
    • 2016
  • Partial discharges (PD) lead to the degradation of high voltage cables and accessories. PD activities occur due to the existence of impurities, voids, contaminants, defects and protrusions during the manufacture and installation of power cables. Commonly, insulation failures occur at cable joints and terminations, caused by inhomogeneous electric field distributions. In this work, a blend of natural rubber (NR) and linear low density polyethylene (LLDPE) was investigated, and the optimal formulation of the blend that could resist PD was discussed. The experiments were conducted under a constant high voltage stress test of 6.5 kV AC and the magnitude of partial discharge activities was recorded using the CIGRE method II. Pattern analysis of PD signals was performed along with the interpretation of morphological changes. The results showed that the addition of 10 wt% of NR and 5 wt% of Alumina Trihydrate (ATH) provided promising results in resisting PD activities. However, as the NR content increased, more micropores existed, thus resulting in increased PD activities within the samples.

The Propagation Characteristics of Electromagnetic Waves in accordance with electrode shapes at VHF Band Using an Antenna (안테나를 이용한 VHF대역에서 전극형태에 따른 방사전자파의 전파특성)

  • 김충년;지승욱;이상훈;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.73-79
    • /
    • 2002
  • In this paper, electromagnetic waves radiated from discharge at three-type electrodes(needle-plane, plane-plane and sphere-plane electrode) using AC power source in air are measured and the peculiar patterns of their spectra are reported. The radiated electromagnetic waves were measured in bandwidth of VHF(30-230[MHz]) using a biconical antenna and a spectrum analyzer. When the discharge onset voltage range, high electric field intensity is shown in frequency band of 45, 70, 80[MHz] in case of needle-plane electrode configuration and 40[MHz] in case of plane-plane and sphere-plane electrodes configuration. However, when the breakdown voltage range, the frequency spectrum distribution of radiated electromagnetic waves appear different in the whole frequency range according to the shapes of electrode.

A Study of Interface between Photovoltaic System and Utility Line using a Current-Source PWM Inverter based on Buck-boost topology (Buck-Boost 형태의 전류형 PWM 인버터를 이용한 태양광 발전과 계통연계에 관한 연구)

  • 주성용;양근령;강필순;김철우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.36-42
    • /
    • 2003
  • This paper presents a new current-source PWM inverter based on Buck-boost configuration to interface between photovoltaic system and utility line. Proposed inverter is consisted by two set of buck-boost topology, and the input inductor is designed to be operated on the discontinuous current conduction mode. So high power factor can be achieved without additional input CtUTent controller. As a result, overall system has simple structure, and it can obtain higher ac output rms voltage than the terminal voltage of the photovoltaic system without additional boosting procedure. The operational modes are theoretically analyzed, and then the validity of the proposed system was verified through simulation and experimental results using a prototype.

Distribution of Potential Rise as a Function of Shape of Grounding Electrodes

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.73-79
    • /
    • 2007
  • In order to analyze the potential rise of grounding systems installed in buildings, a hemispherical grounding simulation system was studied. Potential rise was measured and analyzed regarding the shape and distance of the grounding electrodes by using this system. The system was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured in real time by the horizontal moving probe of be potentiometer. The test grounding electrodes were fabricated through reducing the grounding electrode installed in real buildings such as the ground rod, grounding grid and so on. The potential rise was displayed in a two-dimensional profile and was analyzed regarding the shapes of the ground electrodes. The potential rise of the grounding grid combined with a ground rod was the lowest of every grounding electrode tested. The proposed results can be applicable to evaluating ground potential rise in grounding systems, and the analytical data can be used to stabilize the electrical installations and prevent electrical disasters.

A Study on Power Conversion System for Photovoltaic Generation (태양광 발전용 전력변환장치에 관한 연구)

  • 박정환;장수형;이성근;안병원;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.437-442
    • /
    • 2001
  • Recently, transformerless inverters have been studied to reduce sizes and costs of utility-connected PV systems. This paper presents a transformerless PV inverter using a two-phase boost converter of reduced ripples in input current and output voltage, low voltage stress of semiconductor device and reduced size of input reactor. And new PWM method is introduced, whose on-off time is calculated from simultaneous equation induced by fourier series. To verify a validity of the proposed transformerless inverter, computer simulation has been carried out.

  • PDF

High Efficient and Cost Effective Single Energy Recovery Sustaining Driver with Split Plasma Display Panel (AC-PDP를 위한 고성능 및 저가형 패널분할 단일 에너지 회수 서스테인 구동회로)

  • Choi Seong-Wook;Moon Gun-Woo;Park Jung-Pil;Jung Nam-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.390-392
    • /
    • 2006
  • 단일 서스테인 구동회로서 패널을 수평으로 이등 분할하고 직렬 연결하여 구동회로의 전류 스트레스를 저감하는 새로운 단일 에너지 회수 서스테인 구동회로를 제안한다. 기존의 단일 서스테인 구동회로는 +Vs 및 -Vs의 양극성 전원을 사용함에 따라 기존 구동회로에 비해 전류 스트레스는 그대로이면서 스위치 전압 스트레스가 두 배가 되어 회로 손실 및 발열이 높은 단점을 가지고 있다. 이를 개선하기 위해 제안하는 패널 분할 직렬 연결 단일 에너지 회수 서스테인 구동회로는 패널을 수평으로 이등 분할하고 하프 브리지 인버터를 각각 연결하여 구동 회로의 가스 방전 전류 및 패널 캐패시터의 변위 전류를 기존의 절반으로 줄여 스위치들의 전류 스트레스를 저감하게 된다. 또한 에너지 회수 회로는 능동소자로서 단 하나의 스위치와 단하나의 다이오드만을 사용하므로 그 구조가 단순하여 원가를 절감할 수 한다.

  • PDF

Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound (자켓 컴파운드용 절연재의 수증기투과 및 절연파괴 특성)

  • Song, Jae-Joo;Han, Jae-Hong;Song, IL-Keun;Han, Yong-Hee;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB (Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC (Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE > LLDPE ≒ MDPE > LDPE and WVT ratio was HDPE < LLDPE < MDPE < LLDPE ≒ LDPE${\ll}$PVC. WVT of PVC using for jacket showed characteristic 15 times more than MDPE or LLDPE. Therefore, to development of watertightness cable, our works present need of Changing in insulating materials

  • PDF

A Study on Stability Criterion for Cryocooler Operating HTS Coils (냉동기운전 고온초전도코일의 안전성평가기준에 관한 연구)

  • Ishiyama, Atsushi;Kim, Seok-Beom;Han, Kyung-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.317-323
    • /
    • 2001
  • We investigated the stability of cryocooler-cooled high-temperature superconducting (HTS) coils by using a computer program based on FEM. In this study, the current at which "thermal runaway" occurs, which depends on the relationship between the cooling power of the cryocooler and the heat generation in HTS coils, was adopted as a stability criterion of cryocooler operating HTS coils. It was shown that cryocooler-cooled HTS coil was stable in operating current above the critical current from the numerical analysis results by HTS model coil. And also, if we efficiently remove the heat generation from HTS coils by potimizing heat drain, the ramp-rate limitation can be mitigated because the effect of AC loss by the current rise was too small. Furthermore, in the case of pulsed operation; the HTS model coil is ramped from zero to the peak value in one second and back to zero current in one second, such as the operation of SMES device, the peak value of poerating current is 1.5-2 times greater than that of the thermal runaway current.

  • PDF

Characteristics Comparison of PM Motor according to the Driving method (영구자석형 전동기의 구동방법에 따른 전자기적 특성 및 진동 소음 비교)

  • Hong, Jung-Pyo;Lee, Su-Jin;Kim, Do-Jin;Lee, Byeong-Hwa;Jang, Woo-Kyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.522-527
    • /
    • 2012
  • This paper presents a result of the mechanical noise and vibration analysis as well as the electrical characteristics analysis of the permanent magnet (PM) motor according to the driving method that is Brushless DC (BLDC) drive and Brushless AC (BLAC) drive. To do that, the characteristics of the PM motor, which have the same output power but different driving method, are investigated. At that time, the characteristics such as torque, torque ripple and flux density, and so on, are obtained by finite element analysis (FEA). Besides, noise and vibration are obtained by spectrum analysis. The magnetic noise is defined as noise generated from vibrations due to electromagnetic excitation force. In this paper, the electromagnetic excitation force is analyzed and design process of noise reduction is proposed. Finally, The validity of the analysis results is verified by test.

  • PDF