• 제목/요약/키워드: AC Power

Search Result 3,405, Processing Time 0.03 seconds

Design and Experimental Report for the Special 3D.O.F Robot Manipulator

  • Moon, Dong-Hee;Lee, Woon-Sung;Kim, Jung-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2000-2003
    • /
    • 2003
  • In recent years, robots have been used widely in industrial field and have been expanded as a result of continuous research and development for high-speed and miniaturization. The goal of this paper is to design the serial manipulator through kinematic analysis and to control the position and orientation of end-effector with respect to time. In general, a structure of industrial robot consists of several links connected in series by various types of joints, typically revolute and prismatic joints. The movement of these joints is determined in inverse kinematic analysis. Compared to the complicated structure of parallel and hybrid robot, open loop system retains the characteristic that each link is independent and is controlled easily. AC servo motor is used to place the robot end-effector toward the accurate point with the desired speed and power while it is operated by position control algorithm. The robot end-effector should trace the given trajectory within the appropriate time. The trajectory of end-effector can be displayed on the monitor of general personal computer through Opengl program.

  • PDF

캐패시턴스 측정을 통한 대기압 플라즈마 젯 진단에 관한 연구

  • Hwang, Sang-Hyeok;Lee, Seung-Jun;Lee, Ye-Seul;Choe, Jin-U;Kim, U-Jae;Park, Hye-Jin;Jo, Tae-Hun;Yun, Myeong-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.214.1-214.1
    • /
    • 2016
  • 최근 대기압 플라즈마의 활용분야는 기판의 표면처리, 바이오 분야 등에 널리 활용되고 있지만, 현재까지 정립된 대기압 플라즈마 분석법은 광학적, 전기적 방법으로 이를 통해 대기압 플라즈마를 분석하는데 어려움을 겪고 있다. 가장 널리 사용되는 OES(Optical Emission Spectroscopy) 측정법의 경우에는 플라즈마로부터 방출되는 광을 측정하여, 방출 강도로부터 플라즈마 밀도를 얻는데 어려운 점이 있다. 전기적 진단법 중 하나인 랑뮤어 탐침은 주로 진공장비에서만 사용가능하며, 대기압플라즈마에서 직접 접촉하여 플라즈마에 영향을 주어, 플라즈마 밀도를 정확히 측정하기 어렵다. 본 연구에서는 대기압 플라즈마의 캐페시턴스을 측정하여 플라즈마의 밀도를 측정하였다. DC power supply에서 발생된 DC전원을 인버터를 통해서 AC전원으로 변환한 뒤, Ar가스를 석영관에 주입하여 대기압 플라즈마 젯를 발생시켰다. 발생된 대기압 플라즈마를 석영관 외부 전극 사이에 캐패시턴스로 플라즈마 밀도를 측정하였다. Ar 가스 유량에 따라 플라즈마 밀도를 변화를 살펴보았다.

  • PDF

Modified Transmission Line Protection Scheme in the Presence of SCC

  • Naeini, Ehsan Mostaghimi;Vaseghi, Behrouz;Mahdavian, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.533-540
    • /
    • 2017
  • Distance relay identifies the type and location of fault by measuring the transmission line impedance. However any other factors that cause miss calculating the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of the important factors which directly changes the measured impedance by the relay is series capacitive compensation (SCC). Another factor that changes the calculated impedance by distance relay is fault resistance. This paper provides a method based on the combination of distance and differential protection. At first, faulty transmission line is detected according to the current data of buses. After that the fault location is calculated using the proposed algorithm on the transmission line. This algorithm is based on active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. This method measures the voltage across SCC by phasor measurement units (PMUs) and transmits them to the relay location via communication channels. The transmitted signals are utilized to modify the voltage signal which is measured by the relay. Different operating modes of SCC and as well as different faults such as phase-to-phase and phase-to-ground faults are examined by simulations.

Fault Detection and Diagnosis System for a Three-Phase Inverter Using a DWT-Based Artificial Neural Network

  • Rohan, Ali;Kim, Sung Ho
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.16 no.4
    • /
    • pp.238-245
    • /
    • 2016
  • Inverters are considered the basic building blocks of industrial electrical drive systems that are widely used for various applications; however, the failure of electronic switches mainly affects the constancy of these inverters. For safe and reliable operation of an electrical drive system, faults in power electronic switches must be detected by an efficient system that is capable of identifying the type of faults. In this paper, an open switch fault identification technique for a three-phase inverter is presented. Single, double, and triple switching faults can be diagnosed using this method. The detection mechanism is based on stator current analysis. Discrete wavelet transform (DWT) using Daubechies is performed on the Clarke transformed (-) stator current and features are extracted from the wavelets. An artificial neural network is then used for the detection and identification of faults. To prove the feasibility of this method, a Simulink model of the DWT-based feature extraction scheme using a neural network for the proposed fault detection system in a three-phase inverter with an induction motor is briefly discussed with simulation results. The simulation results show that the designed system can detect faults quite efficiently, with the ability to differentiate between single and multiple switching faults.

Design, Development and Analysis of Embedded Systems for Condition Monitoring of Rotating Machines using FFT Algorithm

  • Dessai, Sanket;Naaz, Zakiyaunnissa Alias Naziya
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.428-432
    • /
    • 2014
  • Rotating machines are an integral part of large electrical power machinery in most of the industries. Any degradation or outages in the rotating electric machinery can result in significant losses in productivity. It is critical to monitor the equipment for any degradation's so that it can serve as an early warning for adequate maintenance activities and repair. Prior research and field studies have indicated that the rotating machines have a particular type of signal structure during the initial start-up transient. A machine performance can be studied based on the effect of degradation in signal parameters. In this paper a data-acquisition system and the FFT algorithm has been design and model using the MATLAB and Simulink. The implementation had been carried out on the TMS320 DSP Processor and various testing and verification of the machine performance had been carried out. The results show good agreement with expected results for both simulated and real-time data. The real-time data from AC water pumps which have rotating motors built-in were collected and analysed. The FFT algorithm provides frequency response and based on this frequency response performance of the machine had been measured.The FFT algorithm provides only approximation about the machine performances.

A study on the Conducted Noise Reduction in Random PWM (Random PWM 기법을 이용한 전도노이즈 저감)

  • Jeong, Dong-Hyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.154-158
    • /
    • 2006
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. Random Pulse Width Modulation (RPWM) is peformed by adding a random perturbation to switching instant while output-voltage regulation of converter is performed. RPWM method for reducing conducted EMI in single switch three phase discontinuous conduction mode boost converter is presented. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300v/1kW with $5%{\sim}30%$ white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

  • PDF

Electrical Charateristics of Step-down Piezoelectric Transformer

  • Shin Hoonbum;Ahn HyungKeun;Han Deuk-Young
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.47-51
    • /
    • 2001
  • In this paper, we have explained electrical characteristics of a step-down Rosen type piezoelectric transformer for AC-adapter. When the electric voltage is applied to the driving piezoelectric vibrator polarized in the longitudinal direction, then output voltage is generated at the generating piezoelectric vibrator polarized in the thickness direction due to the piezoelectric effects. From the piezoelectric direct and converse effects, symbolic expressions between the electric inputs and outputs of the step-down piezoelectric transformer have derived with an equivalent circuit model. With the symbolic expressions, load and frequency characteristics have discussed through simulation. Output voltage and current from a 11-layered and a 13-layered piezoelectric transformers were measured under the various conditions of loads and frequencies. First we measured resonant frequency from impedance curve and got equivalent impedance value of the piezoelectric transformer from admittance plot. It was shown from experiments that output voltage has increased and resonant frequency has changed according to various resistor loads. Output current has decreased inversely proportional to changing of loads. Moreover, the measured values of output voltage and current are well agreed with the simulated values of the proposed equivalent circuit model.

  • PDF

High Performance Speed Control of Switched Reluctance Motor

  • Song, Byeang-Seab;Yoon, Yong-Ho;Choi, Jun-Hyuk;Kim, Jun-Ho;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.457-461
    • /
    • 2001
  • Advantages of switched reluctance motor(SRM) drives make it an attractive candidate for replacing adjustable speed ac and dc drives in both industrial and consumer applications. Furthermore, a simple, low cost and robust SRM drive can be efficiently operated in the hostile environment of an automobile. Generally, the speed control of SRM has a large step change or large torque reference, the output of its PI controller is often saturated. When this happens, the integral state is not consistent with the SRM input, while may give rise to the windup phenomenon. This paper proposes anti-windup control method for SRM speed control system by hysteresis current controlled asymmetry bridge converter. The experimental results show that the speed response has much improved performance, such as a small overshoot and fast settling time at the acceleration and particulary deceleration period with braking mode.

  • PDF

A Review of Ovarian Cyst Management in Oriental Medicine (난소낭종에 대한 한의 임상 연구의 종설)

  • Kim, Dong-Il
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.20 no.4
    • /
    • pp.175-190
    • /
    • 2007
  • Purpose: Ovarian cysts are fluid-filled sacs or pockets within or on the surface of an ovary. Most cysts present little or no discomfort and are noncancerous and harmless. So non-surgical treatments with herbal medicine or acupuncture and moxa therapy are important and suitable in this pathology. But there are few RCT articles about ovarian cyst in Korean Medicine(KM) clinical and research field. Methods: To review treatment method and other research tendency about ovarian cyst in journals related with KM and Traditional Chinese Medicine(TCM) through web-searching. Searching was done through web site #http://omis.ksucc.ac.kr# and pub-med(http://www.ncbi.nlm.nih.gov/sites/entrez) with key words #ovarian cyst#, #TCM#, #herb#, #CAM#, and #acupuncture#. Results: Seven articles were searched in journals related with KM, then six of them were simple case report and the other one was about diagnosis for ovarian cyst and another gynecologic disease such as uterine myoma and infertility through the iris diagnosis. And two articles were searched in journals related with TCM, then one of them was simple case report but the other is RCT article. Conclusion: KM and TCM therapies have some beneficial effect to resolve cyst, but objective power as a evidence is weak in the viewpoint of EBM. So continuous clinical trials such as RCT and multi center trials are needed.

  • PDF

Breakdown Properties of Coolant for HTS Apparatus Operating at Cryogenic Temperature

  • S.M. Baek;J.M. Joung;Kim, S.H
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.52-55
    • /
    • 2003
  • For the dielectric insulation design of any high temperature superconducting (HTS) apparatus in the electrical power systems, the breakdown properties of cryogenic coolants such as $LN_2$ are an important factor of the insulating engineering. Therefore, this paper presented an experimental investigation of breakdown phenomena in $LN_2$ under AC voltage. And we studied the breakdown properties of LN2 with decreasing temperature. Also, the Weibull plots of the breakdown voltage of subcooled $LN_2$ at 65 K for the needle-plane electrode with electrode distance d= 10 mm are studied. The dependence of breakdown voltage for needle-plane and pancake coil-pancake coil electrode on temperature is illustrated. The experimental data suggested that the breakdown voltage of L$N_2$ depend strongly on the temperature of $LN_2$. The breakdown characteristics of $LN_2$ under quasi-uniform and non-uniform electrical field for temperature ranging from 77 K to 65 K were clarified.