• Title/Summary/Keyword: AC/A ratio

Search Result 492, Processing Time 0.033 seconds

A Study on Fatigue Life and Fatigue Crack Propagation Behavior of MMC (MMC의 피로수명과 피로균열전파거동에 관한 연구)

  • 허선철;박원조;최용범
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.127-133
    • /
    • 2002
  • The objective of this study is to investigate fatigue life and fatigue crack propagation behavior The experiment of fatigue life for MMC have been carried out for the stress ratio R=0.1 at 20Hz. Fatigue lift limit of AC4CH alloy is about 70 ㎫ and Fatigue limit of MMC has been increment to 120 ㎫, therefore, fatigue limits of MMC is about 71 % higher than that of AC4CH alloy Crack propagation tests on half-size CT specimen of thickness 12.5mm were conducted by using sinusoidal waveform. The crack length was monitored by compliance method. Test conditions were at 0.1 and 0.05 of load ratio at 10Hz of loading frequency and test load was 2.3kN. The effects of stress ratio on the fatigue crack propagation behavior for MMC was discussed within the Paris law. As the results of this study, Fatigue crack propagation increased with increasing the load ratio.

Effect of Sr/Zr Ratio and Organic Vehicle Addition on Bond Strength of $SrZrO_3 $ Thin Films ($SrZrO_3 $박막의 접착강도에 미치는 Sr/Zr 몰비와 유기화합물 첨가효과)

  • 이세종;이득용;예경환;송요승
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.13-16
    • /
    • 2002
  • $SrZrO_3 $resistive oxide barriers on Ag sheathed Bi2223 tapes were prepared by the sol-gel and dip coating method to reduce AC coupling loss. The performance of the dip-coated $SrZrO_3 $ thin films was evaluated in terms of bond strength by varying the Sr/Zr mol ratio and the amount of organic vehicle (ethyl cellulose and a-terpineol) additives. The bond strength of the coatings increased as the Sr/Zr ratio decreased and the amount of organic vehicle rose, respectively. It was found that the effect of organic vehicle addition was more pronounced, suggesting that the adherence of the $SrZrO_3 $ films on Bi2223 tapes was governed primarily by the amount of organic vehicle additive.

A study on optimal drive waveform and optimal gas mixing ratio of Plasma Display Panel (AC 플라즈마 디스플레이 패널에서의 최적 구동 파형 및 최적 가스 흔합비에 관한 연구)

  • Choi, Hoon-Young;Park, Hun-Gun;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1721-1723
    • /
    • 1997
  • In AC Plasma Display Panel(PDP), serious problems are low radiation brightness and very high discharge voltage. To solve these problems, it is necessary to obtain optimal frequency of drive waveform and optimal gas mixing ratio. This paper presents firing voltage and sustain voltage as frequency of waveform and gas mixing ratio, and proposes optimal frequency of drive waveform and optimal gas mixing ratio.

  • PDF

Composition and Activity of the Asiatic Leafroller, Archippus breviplicanus(Lepidoptera: Tortricidae) Sex Pheromone at Apple Orchards in Korea (사과원에서의 사과무늬잎말이나방(Archippus breviplicanus)의 성페로몬 조성과 활성)

  • 정충렬;한경식;정진교;최경희;이순원;부경생
    • Korean journal of applied entomology
    • /
    • v.40 no.3
    • /
    • pp.219-226
    • /
    • 2001
  • To identity the composition and ratio of the sex pheromone in the asiatic leafroller, Archippus breviplicanus (Walsingham), which is a major pest on apple leaves, and to develop a monitoring system using this sex pheromone, abdominal tips of their virgin female during the calling period were extracted and analysed. The GC/GC-MS analysis revealed the following three compounds; (E)11-tetradecenyl acetate (E11-14: Ac), (Z)11-tetradecenyl acetate (Z11-14: Ac), and tetradecyl acetate(14: Ac) with the ratio of 56:22:22. Electroantennogram (EAG) assay was also conducted to examine biological activity of the components. The three components evoked significantly higher responses than hexane or air but there was no significant differences between the mixtures made by components. Field trapping experiments for determining the optimum blend, seasonal fluctuation and the optimum amount for male attracting were carried out over 4 years from 1997 to 2000. Although male moths were attracted to 8:2 and 7:3 between E11-14: Ac and Z11-14: Ac, their 7:3 blend was found to be the most effective. Archippus breviplicanus appears to occur three times a year in Korea. The optimum amount for monitoring was found to be 1mg per trap. 14: Ac, the third component, did not show synergistic effect on male moth attraction.

  • PDF

Deep learning-based classification for IEEE 802.11ac modulation scheme detection (IEEE 802.11ac 변조 방식의 딥러닝 기반 분류)

  • Kang, Seokwon;Kim, Minjae;Choi, Seungwon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2020
  • This paper is focused on the modulation scheme detection of the IEEE 802.11 standard. In the IEEE 802.11ac standard, the information of the modulation scheme is indicated by the modulation coding scheme (MCS) included in the VHT-SIG-A of the preamble field. Transmitting end determines the MCS index suitable for the low signal to noise ratio (SNR) situation and transmits the data accordingly. Since data field decoding can take place only when the receiving end acquires the MCS index information of the frame. Therefore, accurate MCS detection must be guaranteed before data field decoding. However, since the MCS index information is the information obtained through preamble field decoding, the detection rate can be affected significantly in a low SNR situation. In this paper, we propose a relatively robust modulation classification method based on deep learning to solve the low detection rate problem with a conventional method caused by a low SNR.

Activated Carbon Performance for the Treatment of Diesel-Derived Polycyclic Aromatic Hydrocarbons

  • Choi, Yongju;Luthy, Richard G.
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.2
    • /
    • pp.177-184
    • /
    • 2015
  • This study assessed the performance of activated carbon (AC) amendment to treat polycyclic aromatic hydrocarbons (PAHs) including both parent- and alkylated-moieties in sediment impacted by diesel. A field-collected, diesel-impacted sediment with a NAPL content of 1% was used for the study. No. 2 diesel fuel is weathered by heating at $70^{\circ}C$ for 4 days to obtain a weathered diesel sample having C3-naphthalenes to C2-phenanthrenes/anthracenes (N2/P3) ratio similar to the original sediment. The sediment samples spiked with the weathered diesel to obtain non-aqueous phase liquid (NAPL) contents of 1, 5 and 10% were contacted with AC with a dose of 5% as sediment dry weight for 1 month. By the AC-sediment contact, the freely-dissolved equilibrium concentrations were substantially reduced. Even for sediment with 10% NAPL content, the reductions in the freely-dissolved concentrations were 92% and 75% for total parent-and alkylated-PAHs, respectively. The effect of NAPL contents on the performance of AC was negligible for parent-PAHs, while for alkylated-PAHs, a slightly reduced AC performance was observed. The results suggest that the AC amendment can be an effective option for the treatment of petroleum-impacted sediment with relatively high NAPL contents.

Comparison of Attenuation Correction Methods for Brain SPECT Ima (Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교)

  • Jo, Jin U;Kim, Chang Ho;Na, Soo Kyung;Lee, Gui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Purpose : The purpose of this study was to compare count between Chang's method and CT-based attenuation correction (AC-CT) among the attenuation correction (AC) methods for non-attenuation correction (AC-non) images of Brain SPECT (Single Photon Emission Computed Tomography). Materials and Methods : We injected $^{99m}Tc$ 37Mbq in a Hoffman 3D phantom filled with distilled water in the phantom study, and injected intravenously $^{99m}Tc$-HMPAO 740Mbq in a normal volunteer in the patient study, and then obtained Brain SPECT images with Symbia T6 of Siemens and conducted quantitative brain analysis. Transverse images to which each method was applied were rebuilt at the same position, and 6 regions of interest (ROI) were drawn on each of Slice No. 10, 20 and 30 and then the counts of AC-non, AC-CT and Chang's method were compared. Results : The mean counts of AC-non, AC-CT and Chang's method were $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, and $8752.6{\pm}896.5$, respectively, in the phantom study and $5460.8{\pm}519.6$, $15320{\pm}1171.6$ and $12795{\pm}1422.1$, respectively, in the patient study. In the phantom study, the ratio of AC-CT to AC-non was 3.70 and the ratio of Chang's method to AC-non was 1.92, and in the patient study, they were 2.85 and 2.38, respectively. Conclusion : From this study, we found that AC-CT makes higher AC than Chang's method. In addition, when Chang's method was used, AC in the patient study was higher than that in the phantom study. These results need to be considered also in other examinations.

  • PDF

Direct Duty Ratio Pulse Width Modulation Method for Matrix Converters

  • Li, Yulong;Choi, Nam-Sup;Han, Byung-Moon;Kim, Kyoung-Min;Lee, Buhm;Park, Jun-Hyub
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.660-669
    • /
    • 2008
  • This paper presents a new carrier based pulse-width modulation (PWM) method for matrix converters. By using the concept of average over one switching period, the modulation algorithm and the required equations are derived to synthesize the desired output voltage and to achieve the controlled input power factor. The proposed method uses a continuous carrier and the predetermined duty ratio signals to directly generate the gating signals and, thus, is referred to as "direct duty ratio PWM (DDPWM)". The feasibility and validity of the proposed method were verified by simulation and experiment.

THE GRAPHICAL D-Q TRANSFORMATION OF GENERAL POWER SWITCHING CONVERTERS

  • Rim, Chun-T.;Hu, Dong-Y.;Cho, Gyu-H.
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.388-393
    • /
    • 1988
  • New circuit D-Q transformation concept is introduced to analyze AC converters such as inverters, rectifiers and cyclo-converters with ease. The equivalent linear time invariant circuit is obtained by substituting switches with equivalent turn-ratio variable transformers and changing balanced AC reactors into equivalent DC reactors combined by gyrators. This circuit enables us to utilize the powerful linear system analysis techniques such as Laplace transform otherwise which could not be applied to the time varying switching systems. Direct substitution of switches of DC converters with transformers is shown as a preliminary. Then the modeling procedure is shown for a controlled rectifier-inverter circuit. Finally an analysis example is proposed for a buck-boost inverter and the result is compared with the conventional approach. This approach is applicable to all AC converter families to determine the AC transfer functions and the DC operating points. It is identified that the switching systems are equivalent to the RLC filter circuits with transformers and gyrators.

  • PDF

Method for Improving Overmodulation Performance of an Inverter for the Enhanced Output Torque of AC Motors (교류 전동기의 출력 토크 향상을 위한 인버터의 과변조 성능 개선 방법)

  • Jeong, Hye-In;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.4
    • /
    • pp.273-278
    • /
    • 2019
  • This study proposes a method for improving the overmodulation performance of a three-phase inverter to obtain an enhanced output torque for the AC motors. In the inverter-fed AC motor drives, the output torque of the motor can be enhanced by utilizing the overmodulation region as well as the linear modulation regions of the inverter. The overmodulation method is used for this overmodulation operation of the inverter. However, the voltage gain, the ratio of the output voltage of the inverter to the reference voltage achieved by the conventional overmodulation methods becomes nonlinearly smaller than unity. Therefore, the effect of improving the output torque of the AC motors is insignificant even when the overmodulation region is utilized. In this study, we propose a method that improves the overmodulation performance of the inverter by compensating the limited amount of the reference voltage in the overmodulation operation to enhance the output torque of the AC motors. The effectiveness of the proposed method is verified through the simulations and experiments with an 800 W permanent magnet synchronous motor.