• Title/Summary/Keyword: AC/A ratio

Search Result 492, Processing Time 0.031 seconds

Changes in the Physiology of eye and Ocular function due to alcohol intake (알코올 섭취에 따른 눈의 생리기능과 안기능의 변화)

  • Lee, Jeung-Young;Seo, Jung-Ick;Park, Eun-Kyu
    • Journal of the Korea society of information convergence
    • /
    • v.7 no.2
    • /
    • pp.25-29
    • /
    • 2014
  • In this study, it examined the effects of alcohol on the physiology of the eye and ocular function. It was measured to IOP(intraocular pressure), tear secretion, stereoscopic parallax, AC A ratio, convergence ability, divergence ability alcohol intake before and after. The results were as follows. The mean IOP before alcohol intake 15.14mmHg and the mean IOP after alcohol intake 12.8mmHg. Average decreased 15.44%. The mean tear secretion before alcohol intake 17.125mm and the mean secretion after alcohol intake 9.875mm. Average decreased 42.33%. Stereoscopic parallax has increased by about four times that 40' before alcohol intake to 165' after that. AC/A ratio has increased by 14.6% that $5.40{\Delta}/D$ before alcohol intake to $6.19{\Delta}/D$ after that. Convergence and divergence ability was no significant change in both distance and close range.

  • PDF

Outcomes of endoscopic retrograde cholangiopancreatography-guided gallbladder drainage compared to percutaneous cholecystostomy in acute cholecystitis

  • Hassam Ali;Sheena Shamoon;Nicole Leigh Bolick;Swethaa Manickam;Usama Sattar;Shiva Poola;Prashant Mudireddy
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.1
    • /
    • pp.56-62
    • /
    • 2023
  • Backgrounds/Aims: Endoscopic retrograde cholangiopancreatography-guided gallbladder drainage (ERGD) is an alternative to percutaneous cholecystostomy (PTC) for hospitalized acute cholecystitis (AC) patients. Methods: We retrospectively analyzed propensity score matched (PSM) AC hospitalizations using the National Inpatient Sample database between 2016 and 2019 to compare the outcomes of ERGD and PTC. Results: After PSM, there were 3,360 AC hospitalizations, with 48.8% undergoing PTC and 51.2% undergoing ERGD. There was no difference in median length of stay between the PTC and ERGD cohorts (p = 0.110). There was a higher median hospitalization cost in the ERGD cohort, $62,562 (interquartile range [IQR] $40,707-97,978) compared to PTC, $40,413 (IQR $25,244-65,608; p < 0.001). The 30-day inpatient mortality was significantly lower in hospitalizations with ERGD compared to PTC (adjusted hazard ratio 0.16, 95% confidence interval [CI]: 0.1-0.41; p < 0.001). There was no difference in association with blood transfusions, acute renal failure, ileus, small bowel obstruction, and open cholecystectomy conversion (p > 0.05) between hospitalizations with ERGD and PTC. There was lower association of acute hypoxic respiratory failure (adjusted ratio [AOR] 0.46, 95% CI: 0.29-0.72; p = 0.001), hypovolemia (AOR 0.66, 95% CI: 0.49-0.82; p = 0.009) and higher association of lower gastrointestinal bleed (AOR 1.94, 95% CI: 1.48-2.54; p < 0.001) with ERGD compared to PTC. Conclusions: ERGD is a safer alternative to PTC in patients with AC. The risk complications are lower in ERGD compared to PTC but no difference exists based on mortality or conversion to open cholecystectomy.

Natural Radioactivity of Soils by Bed Rocks Distributed in the Keum River Area (금강유역 기반암 토양의 자연방사능 특성)

  • Lee, Kil-Yong;Yoon, Yoon-Yeol;Cho, Soo-Young;Lee, Jung-Hwa;Lee, Jin-Soo;Koh, Kyung-Seok;Kim, Yong-Je
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.10-16
    • /
    • 2009
  • Characteristics of natural radioactivity were investigated for soils collected from seven sites of different bed rocks distributed in the Keum River area of Korea by the use of a Gamma-ray spectrometry. Specific activity (SA) and SA ratio (SAR) of typical naturally occurring radioactive nuclide such as $^{226}$Ra, $^{228}$Ac and $^{40}$K were determined for the soil samples. The SA values of $^{226}$Ra, $^{228}$Ac and $^{40}$K in 41 soils of 7 sites are 26.7-485 (74.2 ${\pm}$ 72.2), 30.9-157 (90.7 ${\pm}$ 32.7) and 203-1558 (990 ${\pm}$ 203) Bq/kg, respectively. The SA of $^{226}$Ra has very different values by the soils and the sites. Especially the SA of $^{226}$Ra in a soil sample of Ogcheon site is 485 Bq/kg while most SA of 41 soil samples are < 100 Bq/kg. SA of $^{228}$Ac has a little different values with the soils and sites, however the SA of $^{40}$K has almost constant values in all soil samples. The SAR values of $^{26}$Ra/$^{228}$Ac, $^{226}$Ra/$^{40}$K and $^{228}$Ac/$^{40}$K in 41 soils of 7 sites are 0.343-6.11 (0.865 ${\pm}$ 0.883), 0.0258-0.759 (0.0814 ${\pm}$ 0.1l17) and 0.0373-0.178 (0.0945 ${\pm}$ 0.0373), respectively. The SARs of $^{226}$Ra/$^{228}$Ac and $^{226}$Ra/$^{40}$K have very different values by the soils and the sites, however the SAR of $^{228}$Ac/$^{40}$K has a little difference by the soil and sites.

Digital Ratio Differential Relaying for Main Protection of Large Generator (대형 발전기 주보호를 위한 디지털 비율차동 계전기법)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • An AC generator is an important component in producing an electric power and so it requires highly reliable protection relays to minimize the possibility of demage occurring under fault conditions. It is a need for research of digital generator protection system(DGPS) for the next-generation ECMS and an efficient operation of protection control system in power station. However, most of protection and control system used in power plants have been still imported as turn-key and operated in domestic. This may cause the lack of the correct understanding on the protection systems and methods, and thus have difficulties in optimal operation. In this paper, presented ratio differential relaying(RDR) is main protective element in generator protection IED. The fault detection technique, operation zone and setting value of the RDR were studied and, compared with two of the fault detection algorithm. For evaluation performance of the RDR, the data obtained from ATPDraw5.7p4 modeling was used. The proposed methods are shown to be able to rapidly identify internal fault and did not operate a miss-operation for all the external fault.

Petrological characteristics on stone resources of granites in the Pocheon-Euijeongbu area (포천-의정부지역 화강암류 석재자원의 암석학적 특성연구)

  • 윤현수
    • The Journal of the Petrological Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.34-44
    • /
    • 1997
  • The Jurassic granites, commercially called Yangu stone in the Pocheon-Euijeongbu area, have generally compact and coarse-grained textures, which could be classified into two types; grey granite(Gg) and light pink granite(Gp). Specific gravity, absorption ratio and prosity of Gg and Gp in physical property are 2.64 and 2.61, 0.32 % and 0.44 %, 0.86% and 1.13 %, respectively. These higher values of two latters of Gp than those of Gg are due to the more abundant microcracks in Gp. Compressive strength og Gg than those of Gg are due to more abundant microcracks in Gp. Compressive strength og Gg and Gp are 1,726 kg/cm2 and 1,717 kg/cm, respectively and bestrength has a positive proportion with Qz+Af+Pl(quartz+alkali feldspar+plagioclase) modes without trending with Bt+Ac(biotite+accessories). Tensile strength has the positive proportions with Qz+Af+Pl and Bt+Ac. While Bt+Ac has a negative trend with abrasive hardness, Qz+A+Pl shows a positive one. These may suggest Qz+Af+Pl mainly affects on strenghts potentional dimension stone than Gp.

  • PDF

Physical Properties of Activated Carbon with Coal Blend Ratios and Manufacturing Conditions (석탄배합비율과 제조공정조건에 따른 활성탄의 물성변화)

  • Kim, Sang Cheol;Park, Kyung Ai;Lee, Seung Bum;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.835-841
    • /
    • 1998
  • This study was devoted to the manufacturing process of activated carbon(AC) using and anthracite and bituminous coals which were regarded as appropriate for AC manufacturing, and the physcial properties a AC prepared with coal blends were characterized by the ultimate and proximate analysis. Generally, as the fraction of antheracite in AC from anthracite and bituminous coal blends was increased, AC yield was increased whereas iodine value($I_2$) was decreased. Being not related to mixing ratio of coal blends, the apparent density of AC remained constant. Pore development and iodine value of AC based on coal blends(Fushun and Dandong, 75:25 wt. %) were examined, varing carbonization and steam activation conditions. These results showed that the average pore diameter of AC was below $20{\AA}$ in the activation temperature range of 850 to $900^{\circ}C$ and the iodine value was above $1000m^2/g$. When the adsorption capacity of manufactured AC was compared with commercial AC, it is found that the AC from coal blends was comparable to the commercial AC. Therefore, it was confirmed that the characteristics of manufactured AC were changed with manufacturing conditions and the ratios and types of coal blends.

  • PDF

Relationships Between Impurity Gas and Luminance/Discharge Characteristics of AC PDP

  • Heo, Jeong-Eun;Lee, Sung-Hyun;Kim, Young-Kee;Shin, Jooh-Hong;Yoo, Choong-Hee;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.2 no.4
    • /
    • pp.29-33
    • /
    • 2001
  • The luminance and discharge characteristics of an AC PDP may be significantly affected by a small amount of impurity gas in working gas. Impurity gases such as $O_2$, O , C and $H_2$ can be mixed in the manufacturing and lor discharge processes. In this paper, a small amount of impurity gas in AC PDP are introduced intertimally and the relationship between the amount of impurity gas and the luminance/discharge characteristics are investigated. The luminous efficiency decreased seriously with the increase in the partial pressure of impurity gases, especially in $H_2$, $O_2$ and $CO_2$, Under the condition of the impurity gas ratio of 2x $10^{-3}$ for Ar, $N_2$, $H_2$, $CO_2$ and $O_2$, the luminous efficiency decreased to about 8%, 8%, 32%, 36% and 50%, respectively.

  • PDF

A Locally Adapative Fixed Rate DCT Image Coding (고정 부호화율의 국부적응 영상 변환부호화)

  • 심영석;고재홍;이상학
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.14 no.1
    • /
    • pp.22-29
    • /
    • 1989
  • An efficient fixed rate adaptive transform coding is described. Adaptivity is provided by assigning more bits to high ac energy blocks and less bits to low ac energy blocks. Practical and relatively simple adaptation scheme is developed. Overall complexity of our scheme is comparable to the Chen and Smith's scheme. The rate will be adjusted in the same manner as in fixed transform coding. Good performance of the proposed scheme is presented in terms of signal to noise ratio compared with the well known Chen&Smith's scheme. Subjective tests are also presented.

  • PDF

Accuracy Evaluation of CT-Based Attenuation Correction in SPECT with Different Energy of Radioisotopes (SPECT/CT에서 CT를 기반으로 한 Attenuation Correction의 정확도 평가)

  • Kim, Seung Jeong;Kim, Jae Il;Kim, Jung Soo;Kim, Tae Yeop;Kim, Soo Mee;Woo, Jae Ryong;Lee, Jae Sung;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.25-29
    • /
    • 2013
  • Purpose: In this study, we evaluated the accuracy of CT-based attenuation correction (AC) under the conventional CT protocol (140 kVp, on average 50-60 keV) by comparing the SPECT image qualities of different energy of radioisotopes, $^{201}Tl,\;^{99m}Tc$ and $^{131}I$. Materials and Methods: Using a cylindrical phantom, three different SPECT scans of $^{201}Tl$ (70 keV, 55.5 MBq), $^{99m}Tc$ (140 keV, 281.2 MBq) and $^{131}I$ (364 keV, 96.2 MBq) were performed. The CT image was obtained with 140 kVp and 2.5 mA in GE Hawkeye 4. The OSEM reconstruction algorithm was performed with 2 iterations and 10 subsets. The experiments were performed in the 4 different conditions; non-AC and non-scatter correction (SC), only AC, only SC, AC and SC in terms of uniformity and center to peripheral ratio (CPR). Results: The uniformity was calculated from the uniform whole region in the reconstructed images. For $^{201}Tl$ and $^{99m}Tc$, the uniformities were improved by about 10-20% AC was applied, but these were decreased by about 2% as SC was applied. The uniformity of $^{131}I$ was slightly increased as both AC and SC were applied. The CPR of the reconstructed image was close to one, when AC was applied for $^{201}Tl$ and $^{99m}Tc$ scans and $^{131}I$ was distant from 1 and that is only AC. Conclusion: The image uniformity improved by AC on low energy likely to $^{201}Tl$ and $^{99m}Tc$. However, image uniformity of high energy such as $^{131}I$ was improved, when both AC and SC was applied.

  • PDF

The influence of Ne-Xe gas mixture ratio on vacuum Ultraviolet and infrared line in AC-PDP

  • Oh, Phil-Y.;Cho, I.R.;Jung, Y.;Park, K.D.;Ahn, J.C.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.743-747
    • /
    • 2003
  • The improvement of luminance and luminous efficiency is the one of the most important part in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of vacuum ultraviolet(VUV) and infrared(IR) rays in surface discharge AC-PDP with Ne-Xe mixture gas. The influence of Ne-Xe gas-mixture ratio on resonance state $Xe^{\ast}(3P_{1})$ and exited state $Xe^{\ast}(3P_{2})$ has been investigated. It is found that the intensity of VUV 147nm emission is proportional to that of the IR 828 nm emission, and the VUV 173nm emission is roughly proportional to that of the IR 823nm emission. The electron temperature and plasma density have been experimentally measured from the center of sustaining electrode gap by a micro Langmuir probe in AC-PDPs. The plasma density from the center of sustaining electrode gap are shown to be maximum value of $9{\times}10^{11}cm^{-3}$, where the electron temperature is about 1.6 eV in this experiment

  • PDF