• Title/Summary/Keyword: AC/A ratio

Search Result 490, Processing Time 0.029 seconds

LGE's 60-inch AC Plasma Display Panel with $1365{\times}768$

  • Park, Myung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.225-227
    • /
    • 2000
  • LGE developed and demonstrated the first 60-inch full color AC plasma display panel with the 1365 ${\times}$ 768 resolution. Both Sol-gel and E-beam method have been tried for MgO layer, and photolithography has been used for electrodes and phosphor layer to fabricate a 60-inch panel. Selective Erase, Selective Write, Address Display Separate, and Address While Display driving scheme have been tested. Its luminance and contrast ratio is about $550\;cd/m^2$ and 500:1, respectively.

  • PDF

New Electrode Designs for High Luminous Efficiency in AC PDP

  • Moon, Cheol-Hee;Moon, Jae-Seung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.740-743
    • /
    • 2009
  • In this paper we proposed a new electrode design to get an enhanced luminous efficiency in AC PDP. The width and shape of the TTO electrode were varied, and the electro-optical properties such as luminance, power consumption, luminous efficiency were estimated with the variation of frequency, duty ratio and applied voltage. The discharge characteristics were investigated to explain the effect of the new electrode structure on the electro-optical properties.

  • PDF

A Simulation Analysis of the Discharge Characteristics with the Xe Gas Contents (Xe 가스 첨가에 따른 방전 특성 시뮬레이션 분석)

  • You, Il;Song, Young-Joo;Lee, Young-Min;Ok, Jung-Woo;Nahm, Choon-Woo;Lee, Don-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1650-1655
    • /
    • 2012
  • AC-PDPs have recently achieved good performance and their image quality can sufficiently compete with the LCD TV. However, it is necessary more effort to improve the luminance and luminous efficacy in the PDP technology. The gas mixture ratio plays a very important role in discharge characteristics, but the mechanism of gas discharge is complex and complicated. In this paper, we investigate the mechanism of gas discharge with Ne+Xe miture ratio through zero and two dimensional fluid simulation.

A Inverter Design of Reversible Power Converter (가역 전력변환기의 인버터 설계)

  • Chun, J.H.;Lee, H.W.;Baek, S.H.;Kwak, D.K.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.8-13
    • /
    • 2005
  • In this paper discusses single-phase DC-AC Inverter design of reversible power converter that driven by binary combination at different transformer winding ratio by BCD code level. It has a advantage that constructs a control system simply and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/DC-AC multi-level reversible converter.

  • PDF

Electrical Breakdown Strength of Insulation under Combined DC-AC Voltages

  • Grzybowski, S.
    • Electrical & Electronic Materials
    • /
    • v.11 no.10
    • /
    • pp.32-39
    • /
    • 1998
  • Electrical breakdown strength of paper-oil and polypropylene/film-oil insulation samples was measured under dc, ac and pulsating voltages. The latter was obtained by superimposing ac upon dc volate and provides an attractive method for a simultaneous testing and assessment of the state of insulation of the various parts of HV apparatus in service. The measurements were carried out over a wide range of the pulsation ratio defined as p=Eac/Edc. The results obtained under pulsating voltages follow colsely an experssion which relates the breakdown strength to the sum of arc tangent and arc cotangent function of the parameter p. The study was carried out using dry paper as well as paper containing various degrees of moisture. The presence of moisture showed a pronounced effect upon the breakdown strength which varied with the pulsation parameter p.

  • PDF

Influence of AC Frequency on the Liquid Breakup in Electrohydrodynamic Atomization (전기수력학적 미립화에서 교류 주파수가 액적 분열에 미치는 영향)

  • Sung, K.A.;Lee, C.S.
    • Journal of ILASS-Korea
    • /
    • v.9 no.2
    • /
    • pp.41-49
    • /
    • 2004
  • Liquid breakup under the variation of AC frequency has been studied experimentally in the electrohydrodynamic atomization. The effect of parameters such as charging voltage, flow rate, nozzle tip inner diameter and power frequency have been considered. This work was performed to investigate the experimental analysis for the effect of AC frequency on breakup process, the mapping of occurrence of disintegration region, and the relationship between the applied power and the droplet radius. The experimental results show that the increase of applied voltage in a certain frequency band leads to a reduction in the droplet size within the limits from 50Hz to 400Hz. The transition phenomena from dripping mode to spindle mode were observed under the band of sudden fall of droplet radius changing ratio, and the synchronous region were produced within the range of applied voltage from 5kV to 6kV.

  • PDF

A Study of Negative Waveform in ac PDP during Reset and Address Periods (ac PDP에서의 Reset과 Address 구간에서 Negative Waveform특성에 관한 연구)

  • Eom, Cheol-Hwan;Kang, Jung-Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.1
    • /
    • pp.27-31
    • /
    • 2009
  • A characteristic of new waveform, called a negative waveform, was studied during reset and address periods. IR distribution, black luminance and time delay were measured to compare the negative waveform with the conventional positive waveform. Based on the analysis of IR measurement, the negative waveform could accumulate more wall charges than the positive waveform. Also the black luminance of negative waveform was lower than that of positive waveform under the same bias and ramp-slope conditions. During address period, the discharge time lag was measured. The negative waveform was showed 0.25 us faster formative time lag and 0.1 us faster average time lag than those of positive waveform.

  • PDF

A Novel Fault Location Scheme on Korean Electric Railway System Using the 9-Conductor Representation

  • Lee, Chang-Mu;Lee, Han-Sang;Yoon, Dong-Hee;Lee, Han-Min;Song, Ji-Young;Jang, Gil-Soo;Han, Byung-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.220-227
    • /
    • 2010
  • This paper presents a novel fault location scheme on Korean AC electric railway systems. On AC railway system, because of long distance, 40[km] or above, between two railway substations, a fault location technique is very important. Since the fault current flows through the catenary system, it must be modeled exactly to analyze the fault current magnitude and fault location. In this paper, suggesting the novel scheme of fault location, a 9-conductor modeling technique including boost wires and impedance bonds is introduced based on the characteristics of Korean AC electric railway. After obtaining a 9-conductor modeling, the railway system is constructed for computer simulation by using PSCAD/EMTDC. By case studies, we can verify superiority of a new fault location scheme and propose a powerful model for fault analysis on electric railway systems.

Photocatalytic Degradation of Methylene Blue using $TiO_2$ Supported on Activated Carbon (TiO$_2$가 담지된 활성탄을 이용한 Methylene Blue의 광분해)

  • Lee, Jong-Dae;Lee, Tae-Jun;Cho, Kyong-Tae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.153-159
    • /
    • 2006
  • The photocatalytic degradation of methylene blue(MB) was investigated using $TiO_2$ as photocatalyst and UV radiation. $TiO_2$ supported with activated carbon(AC) was prepared by SOL-GEL method and depended on several parameters such as the mass ratio of $TiO_2/AC$, pH and experimental time. The presence of the anatase and rutile crystal phase was determined by XRD analyses of the prepared $TiO_2$. The degradation of MB with $TiO_2/AC$ was about 20% higher than that of AC alone. A variation of photodegradation was negligible under UV radiation conditions ( ${\geq}$ 40W). It was experimentally showed that the photodegradation rate was increased with increasing the amount of photocatalyst. The optimal catalyst was prepared by impregmation of $5wt%-TiO_2$ with AC and was calcined at $300^{\circ}C$, and showed about 99% removal efficiency for 3hrs.

Reset Waveform Generation Circuit Adapting To Temperature Change (온도 적응형 PDP RESET 파형 발생회로의 개발)

  • Shin Min-Ho;Kim Cheul-U
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.587-591
    • /
    • 2005
  • Driving Waveform of AC PDP in reset periode is increased and decreased with constant slope to improve dark room contrast ratio and image quality. But the slope and magnitude of ramp waveform are related to strong and weak discharge with temperature change in AC PDP. So this paper proposes a methods of changing the slope and magnitude of ramp waveform during reset periode according to temperature change in AC PDP. Experimental variable factors ire chosen to setup slope, setdown slope, and -Vy voltage magnitude in Y sustain electrode. The proposed methods are expected to compensate for effect of the temperature change, causing misfiring in high and low temprature, with varing the slope and magnitude of ramp voltage during reset period and improve image quality.