• 제목/요약/키워드: AC(alternating current)

검색결과 162건 처리시간 0.027초

Predictive Current Control of Four-Quadrant Converters Based on Specific Sampling Method and Modified Z-Transform

  • Zhang, Gang;Qian, Jianglin;Liu, Zhigang;Tian, Zhongbei
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.179-189
    • /
    • 2019
  • Four-quadrant converters (4QCs) are widely used as AC-DC power conversion interfaces in many areas. A control delay commonly exists in the digital implementation process of 4QCs, especially for high power 4QCs with a low switching frequency. This usually results in alternating current distortion, increased current harmonic content and system instability. In this paper, the control delay is divided into a computation delay and a PWM delay. The impact of the control delay on the performance of a 4QC is briefly analyzed. To obtain a fundamental value of AC current that is as accurately as possible, a specific sampling method considering the PWM pattern is introduced. Then a current predictive control based on a modified z-transform is proposed, which is effective in reducing the control delay and easy in terms of digital implementation. In addition, it does not depend on object models and parameters. The feasibility and effectiveness of the proposed predictive current control method is verified by simulation and experimental results.

정전기 분무 열분해법에 의한 MgO 박막 증착과 AC-PDP로의 용용에 대한 연구 (Deposition of MgO Thin Films by Electrostatic Spray Pyrolysis(ESP) method and Application to AC-PDP)

  • 김수길;은재환;김형준;김영기;박정후
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.133-138
    • /
    • 2000
  • MgO thin films were deposited using $Mg(tmhd)_2$ as a precursor dissolved in a solvent by electrostatic spray pyrolysis. When a pure tetra hydro furan was used as a solvent, a large number of particles appeared on the MgO thin film surface due to homogeneous nucleation. However, by adding 1-butyl alcohol or 1-octyl alcohol to THF, homogeneous nucleation was restricted and the number density of the large particles was also drastically reduced. X-ray diffraction analysis showed that the MgO films had a (100) preferred orientation regardless of the type of solvents used. Characterization using Fourier Transformed-Infrared and spectroscopic photometer revealed that the crystallized MgO thin films on the glass substrate had a high optical transmittance (> 85 %) in the visible range. Discharge characteristics of MgO thin films deposited by ESP method on an alternating-current plasma display panel were compared with a MgO thin film prepared by reactive radio-frequency planar magnetron sputtering.

  • PDF

DCT계수를 이용한 고속 프랙탈 압축 기법과 화상 심층암호에의 응용 (Fast Fractal Image Compression Using DCT Coefficients and Its Applications into Video Steganography)

  • 이혜주;박지환
    • 한국정보처리학회논문지
    • /
    • 제4권1호
    • /
    • pp.11-22
    • /
    • 1997
  • 프랙탈 화상압축은 원화상을 일정 크기의 블럭으로 분할하고 자기 유사성(self -similarity)을 지닌 유사 영역을 탐색한다. 이 압축방식은 부가적인 코드북의 전송 이 필요하지 않아 높은 압축율을 달성하고 좋은 화질의 재생화상을 제공한다. 이러한 이점에도 불구하고 부호화시 유사 영역의 결정을 위한 복잡한 선형변환의 수행으로 인해 부호와 시간이 증가되는 단점이 있다. 본 논문에서는 블럭의 AC(alternating current)계수들을 이용하여 선형변환의 횟수를 감소시켜 부호화 시간을 줄이는 고속 프랙탈 화상압축을 제안한다. 제안 방식은 기존의 방식과 비교하여 좋은 화질을 제공 한다. 또한, 중요 기밀 데이터를 합성하는 화상 심층암호에 응용한 프랙탈 화상 압축 응용법을 제시한다.

  • PDF

The 2-dimensional Discharge Cell Simulation for the Analysis of the Peset and Addressing of an Alternating Current Plasma Display Panel

  • Kim, Joong-Kyun;Chung, Woo-Jun;Seo, Jeong-Hyun;Whang, Ki-Woong
    • Journal of Information Display
    • /
    • 제2권1호
    • /
    • pp.24-33
    • /
    • 2001
  • The characteristics of the reset and the address discharges of an alternating current Plasma Display Panel (ac PDP) were studied using 2-dimensional numerical discharge cell simulation. We investigated the wall charge variations during the reset discharge adopting ramping reset pulse and the subsequent addressing discharge. The roles of the ramping reset scheme can be divided into two stages, each electrode gathers wall charges during ramping-up of the initial stage and the built-up wall charges are lost during ramping-down of the later stage. Address discharge does not only change the wall charge distributions on the address and the scan electrodes but also on the sustain electrode. The increase in the wall charges on the sustain electrode was observed with the variation of the applied voltage to the sustain electrode during the address period. The increase of the applied voltage to the sustain electrode during the address period is expected to induce the decrease of the sustain voltage during the display period.

  • PDF

중첩전압(직류 +60Hz 교류)에서 18kV 배전용 피뢰기의 전기적 특성 (The electrical properties of in 18kV ZnO surge arrestor with mixed direct and 60Hz Alternating Voltage)

  • 이복희;이승주;이수봉;정동철;백영환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.291-294
    • /
    • 2007
  • This paper preserts the characteristics of leakage currents flowing through 18 kV zinc oxide (ZnO) surge arrester under the mixed DC and AC voltages. The I-V curves of ZnO surge arrester were measured as a function of the voltage ratio K The I-V curves under the mixed DC and AC voltages lay between the pure DC and AC characteristics, and the cross-over phenomenon in I-V curves was observed at the low current region As a result, the increase of DC component to mixed voltages causes the increase of resistive component of total leakage current th ZnO surge arrester.

  • PDF

Influence of Image Sticking on Electra-Optical Characteristics in Alternating-Current Plasma Display Panels

  • Choi, J.H.;Jung, Y.;Jung, K.B.;Kim, S.B.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.760-763
    • /
    • 2003
  • We have investigated the electro-optical characteristics of image sticking in AC PDP. Although Image sticking is one of major factors to determine display quality in AC PDP, so far, it has not being reported why it is occurred and how we can prevent it. In this experiment, we have analyzed the effect of MgO protective layer and phosphor on the image sticking and we have measured the difference of firing voltage, brightness and discharge current between sticking image and normal image in AC PDP. As a result, Phosphor degradation is a more major factor than MgO protective layer and the firing voltage of gas discharge in sticking image is higher than that of normal discharge.

  • PDF

복소 벡터와 dq 변환을 이용한 교류기 모델링에 관한 연구 (A Study on AC Machine Modeling using Complex Vector and dq Transformation)

  • 홍선기;박진호
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1601-1605
    • /
    • 2012
  • Three-phase voltage and current is applied to the three-phase alternating current motors which are commonly used in industry. Three phase variables of a, b, c are converted into d, q, 0 axis and the AC machines are modeled and analyzed. Basically the coordinate transformation or d-q transformation is used for convenience, a few steps are needed to analyze the motor performances - separating d and q components, establishing each equivalent circuit, and solving the differential equations of the circuits. In this study, a modeling technique of induction motor using complex vector is proposed and it can explain the induction motor physically. This method does not need the separating process of d and q components. With this technique, the model becomes simple, is easy to understand in physical, and can get the same results with those from the other models. These simulation results of the proposed model are compared with them for the conformation of the proposed method.

Decomposition Properties of Trifluoroiodomethane under Discharges and Interruptions

  • Cai, Fan-Yi;Tan, Dong-Xian;Zhou, Bai-Jie;Xue, Jian;Xiao, Deng-Ming
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2385-2391
    • /
    • 2018
  • This paper is devoted to detecting decomposition characteristics of Iodotrifluoromethane ($CF_3I$) under alternating current (AC) discharges or load current interruptions. The decomposition products are measured utilizing chromatography-mass spectroscopy. It is found that less than 1% $CF_3I$ gas decomposed after several interruptions at load current of 200 A or hundred times of AC discharges. However, under interruptions at a current of 400 A, more than 95% $CF_3I$ gas decomposed into carbon tetrafluoride ($CF_4$) and hexafluoroethane ($C_2F_6$). The equilibrium compositions based on Gibbs free energy minimization of $CF_3I$ was calculated to explain the decomposition mechanism.

부분공진형 고역률 승강압 컨버터 (High power factor Buck-Boost converter with partial resonant circuit)

  • 서기영;권순걸;이현우;곽동걸;배성식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.126-128
    • /
    • 1993
  • Rectifiers of power conversion system are widely used condenser at input to be cheap and to be simple construction. But this method is produced harmonics of pulse at peak value of input AC voltage. The main circuit which make input current of a sinusoidal wave and improve power-factor is almost taken step-up converter. This paper is able to obtain high power-factor and efficiency because the input current is made sinusoidal wave in single phase alternating current(AC) source. Also the proposed converter is able to minimize switching loss by ZVCS(zero voltage switching and zero current switching).

  • PDF

HIGH SPEED VARIABLE SQUARE WAVE AC SUBMERGED ARC WELDING -FREQUENCY/BALANCE STUDY .250″ PLAIN CARBON STEEL

  • Reynolds, Jon-O;Sean P. Moran
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.361-365
    • /
    • 2002
  • Advancements in silicon phase control (SCR) technologies provide an arc welding power supply that has the capability to allow the alteration of the Alternating Current (AC) welding output. These technologies provide a square wave output involving sixteen frequency selections and multiple balance selections. While an AC out put is known to minimize magnetic disturbances associate with Direct Current (DC), the potentials of a non-sinusoidal waveform have not been explored. The focus of the paper is to determine the effects that the frequency and balance of an AC wave form output will have upon a high speed Submerge Arc (SAW) application. The test matrix of the project includes welding .250" steel plate. Joint type is square groove with a travel speed of 65 IPM. Each of the weld parameters was held constant, only the frequency and/or balance were altered between welds. Each frequency/balance combination involved three-gap spacing. Upon completion of the welds the bead profiles were measured and recorded. A relationships/trends were observed with various frequency and balance values. Optimum frequency and balance values were found for the .250" square groove application which permit consistent weld sizing, ease of slag removal, and minimal plate distortion.

  • PDF