• 제목/요약/키워드: AAPM phantom study

검색결과 47건 처리시간 0.024초

콘빔형 전산화단층영상에서 HU에 의한 두경부 팬텀 경조직의 밀도 측정 (Measurement of hard tissue density of head phantom based on the HU by using CBCT)

  • 김문선;김재덕;강동완
    • Imaging Science in Dentistry
    • /
    • 제39권3호
    • /
    • pp.115-120
    • /
    • 2009
  • Purpose : The purpose of this study was to determine a conversion coefficient for Hounsfield Units(HU) to material density ($g\;cm^{-3}$) obtained from cone-beam computed tomography ($CBMercuRay^{TM}$) data and to measure the hard tissue density based on the Hounsfield scale on dental head phantom. Materials and Methods : CT Scanner Phantom (AAPM) equipped with CT Number Insert consists of five cylindrical pins of materials with different densities and teflon ring was scanned by using the $CBMercuRay^{TM}$ (Hitachi, Tokyo, Japan) volume scanner. The raw data were converted into DICOM format and the HU of different areas of CT number insert measured by using $CBWorks^{TM}$. Linear regression analysis and Student t-test were performed statistically. Results : There was no significant difference (P > 0.54) between real densities and measured densities. A linear regression was performed using the density, $\rho$($g\;cm^{-3}$), as the dependent variable in terms of the HU (H). The regression equation obtained was $\rho=0.00072H-0.01588$ with an $R^2$ value of 0.9968. Density values based on the Hounsfield scale was $1697.1{\pm}24.9\;HU$ in cortical bone, $526.5{\pm}44.4\;HU$ in trabecular bone, $2639.1{\pm}48.7\;HU$ in enamel, $1246.1{\pm}39.4\;HU$ in dentin of dental head phantom. Conclusion : CBCT provides an effective option for determination of material density expressed as Hounsfield Units.

  • PDF

디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구 (The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography)

  • 신수인;김종일;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권3호
    • /
    • pp.223-228
    • /
    • 2008
  • 의학적으로 방사선을 사용 시 가장 중요한 점은 환자의 병을 진단 가능하되 피폭선량을 최소화시켜야 한다는 점이다. 진단용 X-선 중 장파장부분은 대부분 흡수에 관여하게 되어 환자의 피폭선량을 증가시키므로 불필요하다. 이러한 장파장영역을 제거하기 위한 방법으로 가장 효과적인 방법은 여과 판의 사용이다. 이에 부가여과가 없는 경우와 0.3mmCu filter 사용 시의 화질과 피부입사선량에 대해 실험을 해 보았다. ROC 신호용 지름 4mm, 두께 3mm의 아크릴 디스크를 chest phantom에 랜덤하게 위치시키면서 non filter 및 Cu filter시 각 각 20매씩 총 40매의 신호+잡음영상을 촬영하고, 또한 신호가 없는 영상(잡음만의 영상)을 각 각 20매씩 40매 촬영하여 총 80매의 영상을 준비한 후 5명의 방사선종사자가 판독 후 P(S/s), P(S/n) 구하여, ROC곡선을 그리고, 감도와 특이도 및 곡선하면적을 구해 평가하였다. 또한 AAPM(American Association of Physicists in Medicine by the American Institute of Physics)권고에 따른 ANSI chest phantom과 Contrast-detail phantom을 이용하여 non filter 또는 Cu filter사용 시 시각적으로 관찰 가능한 병소의 갯수를 파악하였으며, 또한 두 경우에서 피부입사선량을 측정하였다. 그 결과 Cu filter사용 시에 ROC곡선이 좌상방향에 위치하고, 감도, 곡선하면적 및 CD phantom 병소의 갯수에서 모두 좋은 결과를 나타내었다. 또한 피부입사선량은 감소가 되어 여러 측면에서 부가필터의 사용을 검토해 볼 필요가 있으리라 사료된다.

  • PDF

토모테라피 Hi-Art System의 영상유도 정확성 평가와 환자 피폭에 관한 연구 (Accuracy and radiation exposure from image-guidance in Tomotherapy Hi-Art System)

  • 장재욱;임현수;한만석;김용균;전민철
    • 디지털융복합연구
    • /
    • 제11권10호
    • /
    • pp.577-584
    • /
    • 2013
  • 토모테라피의 영상유도방사선치료는 환자의 자세재현성을 증가시켜 방사선치료의 정확성을 향상 시킬 수 있으나 그 정확성이 검증되어야 하며, MVCT 촬영에 의한 환자피폭이 발생할 수 있다. 본 연구에서 토모테라피의 영상유도 정확성은 1.0mm 이내로 매우 양호하게 측정되었으며, 선량은 각각 Fine(2mm) 3cGy, Normal(4mm) 1.5cGy, Corse(6mm) 1cGy로, 해상력은 Normal에서 비교적 양호하게 나타났다. 따라서 환자 피폭을 줄이기 위해서 Fine 보다 Normal을 선택하고 MVCT 촬영범위를 최소화하여 실시하는 것이 바람직하다.

뇌전산화단층검사에서 방사선량 저감을 위한 최적화 프로토콜 연구 (Optimization of Brain Computed Tomography Protocols to Radiation Dose Reduction)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권3호
    • /
    • pp.116-123
    • /
    • 2018
  • This study is a model experimental study using a phantom to propose an optimized brain CT scan protocol that can reduce the radiation dose of a patient and remain quality of image. We investigate the CT scan parameters of brain CT in clinical medical institutions and to measure the important parameters that determine the quality of CT images. We used 52 multislice spiral CT (SOMATOM Definition AS+, Siemens Healthcare, Germany). The scan parameters were tube voltage (kVp), tube current (mAs), scan time, slice thickness, pitch, and scan field of view (SFOV) directly related to the patient's exposure dose. The CT dose indicators were CTDIvol and DLP. The CT images were obtained while increasing the imaging conditions constantly from the phantom limit value (Q1) to the maximum value (Q4) for AAPM CT performance evaluation. And statistics analyzed with Pearson's correlation coefficients. The result of tube voltage that the increase in tube voltage proportionally increases the variation range of the CT number. And similar results were obtained in the qualitative evaluation of the CT image compared to the tube voltage of 120 kVp, which was applied clinically at 100 kVp. Also, the scan conditions were appropriate in the tube current range of 250 mAs to 350 mAs when the tube voltage was 100 kVp. Therefore, by applying the proposed brain CT scanning parameters can be reduced the radiation dose of the patient while maintaining quality of image.

Neck CT에서 차폐체 재료 변화에 따른 Thyroid 선량 비교 연구 (Comparison of Thyroid Doses for Shielding Material Changes in Neck Computed Tomography)

  • 강은보
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.65-71
    • /
    • 2019
  • 현재 Neck CT의 경우 Thyroid와 같은 표재성 장기의 피폭을 줄이기 위해 Bismuth 차폐체를 많이 사용하고 있다. 그러나 Bismuth 차폐체의 경우 표재성 장기 부근에서 선속 경화현상이 많이 발생하고 CT Number, Noise, Uniformity값의 변동이 심하게 나타난다. 본 연구에서는 주위에서 쉽게 구할 수 있고 가공성이 좋은 Aluminum과 Silicone을 이용하여 기존의 Bismuth 차폐체와 비교하여 차폐체로서의 유용성을 알아보았다. Bismuth(0.06 mmPb)와 차폐율이 비슷한 두께의 Aluminum 7.3mm와 Silicone 21.5mm를 제작하였다. 팬텀(RS-108T)의 Thyroid부근에 TLD(TLD-100)을 올려놓고 각각 5회씩 선량을 측정하였다. 화질 비교를 위해 Neck CT 영상에서 Thyroid 부근 axial영상의 CT Number와 Noise의 변화를 비교하였다. 그리고AAPM팬텀의 영상에서 각각 CT Number와 Noise, Uniformity의 변화를 측정하여 비교하였다. 결과에서 Thyroid에 대한 차폐체별 선량 비교에서 Non-Shield에 비해 Bismuth 차폐체가 14%, Silicone 21.5mm 15%, Aluminum 7.3mm 13%가 감소되었다. 통계적으로 Bismuth 차폐체와 유의한 차이가 없는 것으로 나타났다. Thyroid 부근 영상의 CT Number의 변화에서는 Bismuth 차폐체의 변동이 가장 크게 나타났다. AAPM팬텀 영상평가의 Uniformity 평가에서는 Bismuth차폐체는 부적합으로 Aluminum 7.3mm와 Silicone 21.5mm은 합격기준을 만족하였다. 연구결과 현재 임상에 사용되고 있는 고가의 Bismuth 차폐체와 비교하여 차폐율에서 Aluminum 7.3mm와 Silicone 21.5mm은 비슷한 차폐율을 나타냈으며, 팬텀 영상평가의 항목인 CT Number의 감약 계수 변동, Noise, Uniformity의 비교 실험에서 Bismuth 차폐체보다 우수하게 나타났다. Aluminum과 Silicone을 이용하여 표재성 장기의 크기에 맞게 다양한 차폐체를 만들어 사용한다면 환자 선량을 감쇠시키는데 유용할 것으로 판단된다.

CT 정도관리를 위한 인공지능 모델 적용에 관한 연구 (Study on the Application of Artificial Intelligence Model for CT Quality Control)

  • 황호성;김동현;김호철
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권3호
    • /
    • pp.182-189
    • /
    • 2023
  • CT is a medical device that acquires medical images based on Attenuation coefficient of human organs related to X-rays. In addition, using this theory, it can acquire sagittal and coronal planes and 3D images of the human body. Then, CT is essential device for universal diagnostic test. But Exposure of CT scan is so high that it is regulated and managed with special medical equipment. As the special medical equipment, CT must implement quality control. In detail of quality control, Spatial resolution of existing phantom imaging tests, Contrast resolution and clinical image evaluation are qualitative tests. These tests are not objective, so the reliability of the CT undermine trust. Therefore, by applying an artificial intelligence classification model, we wanted to confirm the possibility of quantitative evaluation of the qualitative evaluation part of the phantom test. We used intelligence classification models (VGG19, DenseNet201, EfficientNet B2, inception_resnet_v2, ResNet50V2, and Xception). And the fine-tuning process used for learning was additionally performed. As a result, in all classification models, the accuracy of spatial resolution was 0.9562 or higher, the precision was 0.9535, the recall was 1, the loss value was 0.1774, and the learning time was from a maximum of 14 minutes to a minimum of 8 minutes and 10 seconds. Through the experimental results, it was concluded that the artificial intelligence model can be applied to CT implements quality control in spatial resolution and contrast resolution.

New methods for optical distance indicator and gantry angle quality control tests in medical linear accelerators: image processing by using a 3D phantom

  • Shandiz, Mahdi Heravian;Layen, Ghorban Safaeian;Anvari, Kazem;Khalilzadeh, Mohammadmahdi
    • Radiation Oncology Journal
    • /
    • 제33권1호
    • /
    • pp.42-49
    • /
    • 2015
  • Purpose: In order to keep the acceptable level of the radiation oncology linear accelerators, it is necessary to apply a reliable quality assurance (QA) program. Materials and Methods: The QA protocols, published by authoritative organizations, such as the American Association of Physicists in Medicine (AAPM), determine the quality control (QC) tests which should be performed on the medical linear accelerators and the threshold levels for each test. The purpose of this study is to increase the accuracy and precision of the selected QC tests in order to increase the quality of treatment and also increase the speed of the tests to convince the crowded centers to start a reliable QA program. A new method has been developed for two of the QC tests; optical distance indicator (ODI) QC test as a daily test and gantry angle QC test as a monthly test. This method uses an image processing approach utilizing the snapshots taken by the CCD camera to measure the source to surface distance (SSD) and gantry angle. Results: The new method of ODI QC test has an accuracy of 99.95% with a standard deviation of 0.061 cm and the new method for gantry angle QC has a precision of $0.43^{\circ}$. The automated proposed method which is used for both ODI and gantry angle QC tests, contains highly accurate and precise results which are objective and the human-caused errors have no effect on the results. Conclusion: The results show that they are in the acceptable range for both of the QC tests, according to AAPM task group 142.

요오드 조영제를 이용한 전산화단층촬영장치의 자가진단 직선성 정도관리 기술 개발 (Development of Self-Diagnosis Linearity Quality Assurance Technique in Computed Tomography by Using Iodic Contrast Media)

  • 성열훈
    • 한국콘텐츠학회논문지
    • /
    • 제15권5호
    • /
    • pp.436-443
    • /
    • 2015
  • 본 연구는 요오드 함량이 다른 조영제를 증류수로 희석한 비율과 관전압의 조건별로 CT number를 측정하여 전산화단층촬영장치의 자가진단 직선성 정도관리 기술을 개발하고자 하였다. 사용된 장비는 4-채널 MDCT를 이용하였고, 요오드 조영제는 300 mgI/ml, 350 mgI/ml, 370 mgI/ml, 400 mgI/ml를 사용했다. 증류수에 대한 조영제 희석비율은 최대 농도값이 측정될 때까지 5%씩 증가하였다. 관전압은 90 kVp, 120 kVp, 140 kVp를 적용하였다. 그 결과, 90 kVp에서 400 mgI/ml 조영제가 5% ~ 25%에서 희석된 비율 구간과 CT number들 간의 상관계수가 0.993으로 가장 근사한 직선성을 구하였다. 본 연구에서 제시한 요오드 조영제를 이용한 자가진단 직선성 평가는 AAPM CT 성능평가용 팬톰을 대체할 수 있는 정도관리 방법으로 이용할 수 있다.

CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식 유도 (Derivation of the Effective Energy Calculation Formula of the X-ray Beam Generated by the CT Simulator)

  • 김종언;이상훈
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.869-875
    • /
    • 2021
  • 이 연구의 목적은 CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식을 유도하는데 있다. 90, 120, 140 kVp X-선 빔 하에서, AAPM CT 성능 팬텀의 CT수 교정 삽입부는 CT 모의치료장치로 5번 스캔하였다. 폴리에틸렌, 폴리스틸렌, 물, 나일론, 폴리카보네이트, 그리고 아크릴의 CT수는 각각의 CT 슬라이스 영상에 대하여 측정하였다. 단일 관전압 하에서 측정된 CT수 평균값과 미국표준기술연구소의 자료로부터 계산된 각각의 광자에너지에 대응하는 선감쇠계수들을 선형정합하였다. 얻어진 상관계수들 중 최대값을 갖는 광자에너지를 유효에너지를 결정하였다. 이와 같은 방법으로, 각각의 관전압에서 생성된 X-선 빔의 유효에너지를 결정하였다. 결정된 유효에너지(y)들와 관전압(x)들을 선형정합하여 유효에너지 계산식으로서 y=0.33026x+30.80263을 유도하였다.

고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰 (A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources)

  • 백태성;이승욱;나수경
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.19-26
    • /
    • 2007
  • 목 적: Ir-192 고선량율 근접치료(HDR Brachytherapy)선원에 대한 다양한 측정절차의 효율을 서로 비교할 것이며, 측정 장비의 추가 구입 없이 대안으로 새롭게 만든 PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom에 대한임상에서의 적합성과 유용성을 알아 보았다. 대상 및 방법: 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템을 이용하여 측정값을 비교하였다. Source calibration jig와 PMMA plate phantom을 사용 했을 때에는 Farmer type chamber를 이용하여 측정하였으며, 각각 5회씩 측정하여 제조업체의 측정치와 비교하였다. 또한 새로운 선원을 교환 할 때마다 제조업체로부터 선원과 함께 제공되는 제조업체의 측정치를 본 연구의 측정치와 비교하여 방사능의 정확도를 평가 하였다. 결 과: Well type chamber, Source calibration jig, PMMA plate phantom를 사용한 Ir-192 선원의 측정결과 제조업체 측정치와의 상대오차에 대한 RMS (Root Mean Square)값은 Well type chamber에서 0.6%, Source calibration jig에서 1.57%, PMMA plate phantom에서는 2.1%를 나타내었다. 또한 평균 오차에 대한 편차는 Well type chamber에서 $-0.2{\pm}0.5%$, Source calibration jig에서 $0.97{\pm}1.23%$, PMMA plate phantom에서는 $-0.89{\pm}1.87%$를 나타내었다. 결 론: 본 연구를 통해 실험한 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템의 결과에서 나타난 것처럼, Well type chamber를 이용한 측정결과가 가장 우수하게 나타났다. 또한 측정 장비를 구입하지 않고 대안으로 새롭게 만든 PMMA plate phantom의 결과 권고안 ${\pm}5%$를 초과하지 않으므로 임상에서 유용하게 사용 할 수 있을 것이라 생각되어진다.

  • PDF