• Title/Summary/Keyword: A-D test

Search Result 10,520, Processing Time 0.04 seconds

Image Sticking Evaluation Methods for OLED TV Applications

  • Lee, Hun-Jung;Choi, Dong-Wook;Lee, Eun-Jung;Kim, Su-Young;Shin, Mi-Ok;Yang, Sun-A;Lee, Seung-Bae;Lee, Han-Yong;Berkeley, Brian H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1077-1080
    • /
    • 2009
  • In this paper, we propose a new method for measuring image sticking of an OLED display using a human visual test. We determined that the perceptual image sticking threshold is 2% of luminance difference at 200 nits and 1% at 100 nits, respectively. Color shift must also be considered when evaluating image sticking, as a ${\Delta}$(u', v') shift of just over 0.002 can be recognized regardless of background brightness. Perception of image sticking is affected by the background level, test pattern, and ambient illumination conditions. The evaluation standard must consider both luminance variation and color shift simultaneously.

  • PDF

A development of test and evaluation equipment for pulsed doppler radar (펄스도플러 레이더 시험장치 개발)

  • 신현익;이정욱
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.7
    • /
    • pp.154-162
    • /
    • 1996
  • The test and evaluation is a integal part of the radar development process and it consists of two parts, field test and in-house test using a standard simulated signal. To take the in-house test, the test environment is needed to generate the critical signal that is used to determine the system design parameters and consists of general urpose measurement equipments, specialized boards and operating softwares. This paper presents the in-house test environment configuration and its function for radar system. Because this test environment genrates the simulated radar signal which has arbitrary flight path and target condition, the developed test environment makes easily to evaluate the function for radar system. The program ability of test parameters makes it possible to apply a test for 2D and 3D radar system.

  • PDF

Analysis of Partial Least Square Regression on Textural Data from Back Extrusion Test for Commercial Instant Noodles (시중 즉석 조리 면의 Back Extrusion 텍스처 데이터에 대한 Partial Least Square Regression 분석)

  • Kim, Su kyoung;Lee, Seung Ju
    • Food Engineering Progress
    • /
    • v.14 no.1
    • /
    • pp.75-79
    • /
    • 2010
  • Partial least square regression (PLSR) was executed on curve data of force-deformation from back extrusion test and sensory data for commercial instant noodles. Sensory attributes considered were hardness (A), springiness (B), roughness (C), adhesiveness to teeth (D), and thickness (E). Eight and two kinds of fried and non-fried instant noodles respectively were used in the tests. Changes in weighted regression coefficients were characterized as three stages: compaction, yielding, and extrusion. Correlation coefficients appeared in the order of E>D>A>B>C, root mean square error of prediction D>C>E>B>A, and relative ability of prediction D>C>E>B>A. Overall, 'D' was the best in the correlation and prediction. 'A' with poor prediction ability but high correlation was considered good when determining the order of magnitude.

A Study on the Automotive Structural Change of High Intensity Discharge Head lamp (자동차 전조등 고압 방전 램프 구조 변경에 대한 연구)

  • Lim, Ju-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.2
    • /
    • pp.53-60
    • /
    • 2008
  • A test was conducted using two high density discharge lamps, the H2D and the structurally new H4D. They were tested for luminous illumination and luminous temperature in the day and night time. The test was conducted without crippling the performance of the H2D by adding a magnetic actuator, enabling it to move left to right, and up and down. By making these modifications we constructed a sample of the H4D. We compared the H2D and the H4D sample's luminous illumination and luminous temperature by using a photometer and a digital thermometer in the day and night time. We discovered that the H2D and H4D performed similarly from the data we gathered. Now we know the H4D has potential use and extensive research needs to be made to gather more detailed data.

Investigation of the Hydraulic Stability of Agricultural Drainage Channels Installed Water Purification Materials by using Flow-3D (Flow-3D를 활용한 수질정화체가 설치된 농업용 배수로의 안정성 조사)

  • Kim, Sun-Joo;Park, Ki-Chun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.5
    • /
    • pp.3-9
    • /
    • 2007
  • In this study, the effect of the purification materials is analyzed and tested by Flow 3D and Hydraulic model test. Three dimension numerical analysis led from the research that sees abnormal form and the size back of the water purification material conferred the flowing water conduct inside the test channel against the test condition. Comparison it analyzed the flux distribution, a water depth of the channel which establishes the water purification materials the cross section, an interval of the water purification material, a conference with general channel, it change executed. As a result, the cross section ratio of the purification materials against and a flux change from the test which it sees. The interval of the purification materials in order to prevent three dimension that follows in decrease of increase and flux must decide an interval.

A Study of Reportable Range Setting through Concentrated Control Sample (약물검사에서 관리시료의 농축을 이용한 보고 가능 범위의 설정에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Choi, Ho Sung;Park, Yong Won;Yun, Keun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • This study was designed to establish working range for reoportable range in own laboratory in order to cover the upper and lower limits of the range in test method. We experimented ten times during 10 days for setting of reportable range with between run for method evaluation. It is generally assumed that the analytical method produces a linear response and that the test results between those upper and lower limits are then reportable. CLIA recommends that laboratories verify the reportable range of all moderate and high complexity tests. The Clinical Laboratory Improvement Amendments(CLIA) and Laboratory Accreditation Program of the Korean Society for Laboratory Medicine states reportable range is only required for "modified" moderately complex tests. Linearity requirements have been eliminated from the CLIA regulations and from others accreditation agencies, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. It is important to assess the useful reportable range of a laboratory method, i.e., the lowest and highest test results that are reliable and can be reported. Manufacturers make claims for the reportable range of their methods by stating the upper and lower limits of the range. Instrument manufacturers state an operating range and a reportable range. The commercial linearity material can be used to verify this range, if it adequately covers the stated linear interval. CLIA requirements for quality control, must demonstrate that, prior to reporting patient test results, it can obtain the performance specifications for accuracy, precision, and reportable range of patient test results, comparable to those established by the manufacturer. If applicable, the laboratory must also verify the reportable range of patient test results. The reportable range of patient test results is the range of test result values over which the laboratory can establish or verify the accuracy of the instrument, kit or test system measurement response. We need to define the usable reportable range of the method so that the experiments can be properly planned and valid data can be collected. The reportable range is usually defined as the range where the analytical response of the method is linear with respect to the concentration of the analyte being measured. In conclusion, experimental results on reportable range using concentrated control sample and zero calibrators covering from highest to lowest range were salicylate $8.8{\mu}g/dL$, phenytoin $0.67{\mu}g/dL$, phenobarbital $1.53{\mu}g/dL$, primidone $0.16{\mu}g/dL$, theophylline $0.2{\mu}g/dL$, vancomycine $1.3{\mu}g/dL$, valproic acid $3.2{\mu}g/dL$, digitoxin 0.17ng/dL, carbamazepine $0.36{\mu}g/dL$ and acetaminophen $0.7{\mu}g/dL$ at minimum level and salicylate $969.9{\mu}g/dL$, phenytoin $38.1{\mu}g/dL$, phenobarbital $60.4{\mu}g/dL$, primidone $24.57{\mu}g/dL$, theophylline $39.2{\mu}g/dL$, vancomycine $83.65{\mu}g/dL$, valproic acid $147.96{\mu}g/dL$, digitoxin 5.04ng/dL, carbamazepine $19.76{\mu}g/dL$, acetaminophen $300.92{\mu}g/dL$ at maximum level.

  • PDF

Study on Electrical Environmental Obstacle Using a 765kV Double Circuit Test Line (765kV 시험선로를 이용한 전기환경장해 특성연구)

  • Kim, Jeong-Boo;Jo, Seong-Sae;Shin, Goo-Yong;Lee, Dong-Il;Yang, Kwang-Ho;Ahn, Hee-Sung;Bae, Jeong-Hyo;Koo, Ja-Yoon;Min, Seok-Weon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1517-1519
    • /
    • 1994
  • This paper describes electrical environmental study of a 765kV double circuit test line. Corona performance on several candidate conductor bundles has been investigated in the corona cage (single phase simulation facility) since 1984. We have known that six RAIL conductor bundle is the most suitable for the 765kV transmission Line, [3] To investigate electrical environmental impact of the future commerciale line, we build a full sacle 765kV test line in 1993. The test results of Audible Noise, Radio Interference, TV Interference from August, 1993 to Jan. 1994 were measured as $48.7[dBA](L_{50})$. $57.4[dB{\mu}V/m]$(Fair weather, $L_{50})$. $14.5[dB${\mu}$V/m]$(Fair weather, $L_{50}$). We have found that the Audible Noise data were very close to the predicted(48.5 [dBA]) by BPA Corona and Field Effects Computer program, however, the RI and TVI data were much higher than predicted(42 [dBmV/m], $7.9[dB{\mu}V/m)$ by the BPA program. We have investigating the reason of the difference. In the constructing of full scale test line, we developed the tubular tower, 765kV test transformer and hardwares of 765kV transmission line insulator strings. Also we will investigate the effects of plants under the 765kV test Line.

  • PDF

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF

A Study on Economic Analysis and Performance Appraisal of Compact Type Variable Air Volume (컴팩트형 VAV 공조기의 성능평가와 경제성 분석에 관한 연구)

  • Kim, Dong-Cheol;Chung, Kwang-Seop;Kim, Young Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.44-49
    • /
    • 2015
  • Ceiling cooling and heating system that consider load arrangement and space in the ceiling needs to be developed. Therefore, experimental and economic changes were done to verify the performance of compact type VAV. The test results were as follow. 1) Noise test result, measuring approximately 50.4 dB~56.6 dB (before ceiling in landfill), had a better ceiling deadline than the current measure, about a 10 dB noise reduction, so that the office baseline (40~50 dB) noise was judged to be less than test. 2) For the static pressure test result, taking out an outside hydrostatic 25 mmAq, 24.8 mmAq was measured, respectively, at the point. 3) For the life-cycle cost analysis result, the initial investment cost, maintenance replacement costs, and maintenance costs increased 0.2%, but the energy savings ratio was 19.5% while the whole life cycle savings of 40 years LCC was reduced 11.9%.

3D Face Dimensions and New Fit Test Panels for the Labor Population Using Respirators in South Korea (호흡보호구 사용 노동인구의 3차원 얼굴사이즈 특징 및 한국형 밀착도 검사 패널 개발)

  • Jung-Keun Park;Se-Dong Kim;Hyoun-Min Cho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.247-264
    • /
    • 2023
  • Objectives: The study was to examine the features of three-dimensional(3D) face dimensions and to develop fit test panels for the labor population using respirators in South Korea. Methods: This study was part of the first-year work of a two-year-project conducted at Occupational Safety and Health Research Institute in 2021. After 3D head dimensions data were collected from Size Korea Center managing Sixth Size Korea databases, 3D face dimensions DB for the South Korean labor population was established for 21 items of face dimensions in line with the ISO/TS 16976-2 and KS A ISO 15535. With the South Korean labor population 3D face dimensions DB, in accordance with the ISO/TS 16976-2, the descriptive statistics of 3D face dimensions were calculated and two fit test panels were developed. Results: A total of 2,752 subjects were finally determined and they were 52.9% for male, 41.2% for the highest age-group of 15-29, and residents in the capital area. Mean and standard deviation were obtained for each of the 21 3D face dimensions items for the South Korean labor population. Among the items, male and female face widths were 137.6±5.7 mm, 133.2±5.0 mm, respectively. Male and female face lengths were 116.6±7.0 mm, 107.8±6.8 mm, respectively. Two new South Korean fit test panels, a bivariate test panel and a principal component analysis test panel, were developed using the 3D face dimensions DB as well. Conclusions: Using the 3D face dimensions DB, the mean and standard deviation were featured for each of the 21 items and also the two fit test panels were newly developed in the study. It is suggested that the study outputs should be utilized practically and effectively in selection, use, and management of respirators at work, expecting that respiratory protection can be furthermore improved for respirator users including labor population across the country.