• Title/Summary/Keyword: 95% reliability

Search Result 693, Processing Time 0.026 seconds

Study of the Reliability and Validity of the WOMAC Index in Patients with Total Knee Replacement (무릎관절 전치환술 환자에 대한 WOMAC 지수의 신뢰도와 타당성에 관한 연구 )

  • Hoon Jo;Kyoung Kim;Sang-Cheol Im
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.2
    • /
    • pp.93-101
    • /
    • 2023
  • PURPOSE: The Western Ontario and McMaster Universities Arthritis (WOMAC) index has been used to measure the outcome of total knee replacement (TKR), but studies on its reliability and validity are limited. The present study examined the reliability and validity of this index for patients with knee osteoarthritis who underwent TKR. METHODS: Seventy-one inpatients and outpatients who underwent bilateral TKR for knee osteoarthritis were included in this study. The pain assessment scale and WOMAC index were used to evaluate the participants every two weeks to examine the test-retest reliability, internal consistency, and construct validity. RESULTS: The test-retest reliability scores for pain, stiffness, and physical function were .75-.92, .85-.90, and .75-.95, respectively. The corresponding intraclass correlation coefficients were .75-.88, .76-.88, and .71-.95, respectively. The internal consistency score in the first and second examinations was .92. Furthermore, the construct validity scores for pain, stiffness, and physical function were .83, .41, and .58, respectively. CONCLUSION: The application of the WOMAC index in patients who underwent TKR showed high test-retest reliability and internal consistency with the use of the WOMAC index and good validity with the use of the pain assessment scale.

Vibration Prediction and Charge Estimation in Hard Rock Blasting Site (경암층 발파현장에서 진동예측 및 장약량산정)

  • Park, Yeon-Soo;Park, Sun-Joon;Choi, Sun-Min;Mun, Soo-Bong;Mun, Byeong-Ok;Jeong, Gyung-Yul;Jeong, Tae-Hyeong;Hwang, Seung-Ill;Kim, Min-Jung;Park, Sang-Chul;Kim, Jung-Ju;Lee, Byeong-Geun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.3
    • /
    • pp.313-319
    • /
    • 2009
  • The blasting has a lot of economic efficiency and speediness but it can damage to a neighbor structure, a domestic animal and a cultured fish due to the blasting vibration, then the public grievance is increased. Therefore, we need to manage the blasting vibration efficiently. The prediction of the correct vibration velocity is not easy because there are lots of different kinds of the scale of blasting vibration and it has a number of a variable effect. So we figure the optimum line through the least-squares regression by using the vibration data measured in hard rock blasting and compared with the design vibration prediction equation. As a result, we confirm that the vibration estimated in this paper is bigger than the design vibration prediction equation in the same charge and distance. If there is a Gaussian normal distribution data on the left-right side of the least squares regression, then we can estimate the vibration prediction equation on reliability 50%(${\beta}=0$), 90%(${\beta}=1.28$), 95%(${\beta}=1.64$). 99.9%(${\beta}=3.09$). As a result, it appears to be suitable that the reliability is 99% at the transverse component, the reliability 95% is at the vertical component, the reliability 90% is at the longitudinal component and the reliability is 95% at the peak vector sum component.

The Cross Cultural Adaptation For Neck Disability Questionnaires (목 기능장애 설문지의 절충 문화 적응)

  • Lim Chang-hun;Lee Hae-jung;Bae Sung-soo;Kim Jin-sang
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.2
    • /
    • pp.46-66
    • /
    • 2005
  • With the increase in the number of multinational and multicultural research projects, the need to adapt health status measures for use in other than source language has also grown rapidly. Most questionnaire were developed in English-speaking countries, but even within these countries, researchers must consider immigrant populations in studies of health, especially when their exclusion could lead to a systematic bias in studies of health care utilization or quality of life. The purpose of this study was to translate and and culturally adapt the three most used neck and spinal pain disability questionnaires - the Neck Disability Index(NDI), Neck pain and Disability Scale(NPDS), and Functional Rating Index(FRI) - into the korean language and evaluated their reliability, in addition to item response pattern, to achieve a good cross cultural adaptation. Each translated questionnaire was found to have high reliability (FRI ICC (2,1)=0.86 ($95\%$ CI: 0.75-0.92); NPDS ICC (2,1)=0.90 ($95\%$ CI: 0.83-0.95 ; NDI ICC (2,1) =0.90 ($95\%$ CI: 0.81-0.94)). The reliability of the translated versions of FRI, NPDS and NDI were excellent.

  • PDF

An Analysis of the Reliability and Validity of a Korean Version of the Mobility and Gait Assessment Tools for Patients with Stroke

  • Jang, Ho Young;Lee, Jeong-Hoon;Oh, Jung Lim;Lee, Hyun Soo;Lee, Suk Min
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.1
    • /
    • pp.29-34
    • /
    • 2018
  • Purpose: This study aimed to systematically analyze the reliability and validity of Korean versions of mobility and gait assessment tools for patients with stroke. Methods: Two reviewers conducted an independent literature search and systematically reviewed the literature. Literature published until June of 2017 was searched using search engines for electronic databases. The 2 reviewers reviewed the title and abstract of each article. Among the articles examined, we read the full text of those judged to be suitable for our study. We classified the selected data into research methods and results. The determination was made through mutual agreement. Results: The reviewers selected 5 articles related to the purpose of this study. The DGI was found to be moderately associated with BBS, 10MWT, and TUG in intra-rater reliability (ICC=0.92), inter-rater reliability (ICC=0.88), and concurrent validity tests. The FGA demonstrated a high level of reliability with intra-rater (ICC=0.92-0.95) and inter-rater reliability (ICC=0.91, 0.95). The intra-rater reliability of the RMI was high at ICC=0.98. Its concurrent validity showed a high association with STREAM and BI. The intra-rater reliability of the MAS was ICC=0.75-0.99. Its inter-rater reliability was very high, exceeding 0.99. The inter-rater reliability of the Tinetti-gait Scale was ICC=0.91, and its concurrent validity was moderately associated with the DGI, 10WMT, OLST, FM-L/E, and STS. Conclusion: The results of this study revealed that the reliability and validity of the Korean versions of the mobility and gait assessment tools were high.

Intra- and Inter-Rater Reliability of Thickness Measurement of the Psoas Major Muscle Using the Spring Gauge Technique for the Consistent Inward Pressures on Healthy Subjects: An Ultrasonographic Study

  • Jeon, In-Cheol;Kim, Yong-Wook;Choung, Sung-Dae
    • Physical Therapy Korea
    • /
    • v.20 no.4
    • /
    • pp.65-72
    • /
    • 2013
  • The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness (MT) measurement of the psoas major (PM) using ultrasonography (US) conducted at different inward pressures of approximately .5 kg, 1.0 kg, 1.5 kg, and 2.0 kg. Twelve healthy male subjects were recruited for the study. The thicknesses of both PMs of each subject were measured by two different examiners in a random manner to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval (CI). ICC (2,1) was used to determine the inter-rater reliability and ICC (3,1) was used to assess the intra-rater reliability of the MT measurement of the PM. The results indicated higher ICC values for intra-rater reliability compared to inter-rater reliability. In addition, the value for intra-rater reliability with .5 kg inward pressure [ICC=.99 (95%CI=.98~.99)] was higher compared to 1.0 kg, 1.5 kg, and 2.0 kg. Other inward pressures for intra- and inter-rater reliability in current study were also demonstrated to have excellent values (ICC=.94~.99). These findings showed that maintaining consistent inward pressure is essential for maintaining reliability of the results when the MT of the PM is measured by different examiners in a clinical setting.

Reliability and Validity of the Postural Assessment Scale for Stroke in Chronic Stroke Patients (만성뇌졸중 환자의 Postural Assessment Scale for Stroke의 신뢰도와 타당도)

  • An, Seung-Heon;Lee, Je-Hoon
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-17
    • /
    • 2009
  • Purpose: The purpose of this study was to determine reliability and validity of the Postural Assessment Scale for Stroke Patients (PASS) in chronic stroke patients. Methods: A total of 43 stroke patients, who had a stroke more than 6 months previously, participated in the study. Reliability was determined by the intra-class correlation coefficient (ICC$_{3,1}$), Bland and Altman method and Cronbach's alpha by internal consistency. Validity was examined by correlation the PASS scores to the Berg Balance Scale (BBS), Trunk Control Test (TCT), and Fugl-Meyer Balance (FM-B) score. Results: The intra-rater reliability and the Absolute reliability of the PASS was good ICC$_{3,1}$=0.97 (95%CI 0.95$\sim$0.99) and excellent SEM=1.01 respectively. Cronbach's alpha value for PASS was found to be 0.94. There were significant correlations between the PASS and BBS, TCT, FM-B (r=0.65-0.96, p<0.01). Conclusion: The PASS provide reliable and valid instrument of the postural control assessment for chronic stroke patients.

  • PDF

Dynamic Response based System Reliability Analysis of Structure with Passive Damper - Part 2: Assessment of System Failure Probability (수동형 댐퍼를 장착한 구조물의 동적응답기반 신뢰성 해석 - 제2편: 시스템 파괴확률 산정)

  • Kim, Seung-Min;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.95-101
    • /
    • 2016
  • This study proposes a multi-scale dynamic system reliability analysis of control system as a method of quantitative evaluation of its performance in probabilistic terms. In this second paper, we discuss the control effect of the viscous damper on the seismic performance of the structure-level failure. Since the failure of one structural member does not necessarily cause the collapse of the structural system, we need to consider a set of failure scenarios of the structural system and compute the sum of the failure probabilities of the failure scenarios where the statistical dependence between the failure scenarios should be taken into account. Therefore, this computation requires additional system reliability analysis. As a result, the proposed approach takes a hierarchial framework where the failure probability of a structural member is computed using a lower-scale system reliability with the union set of time-sequential member failures and their statistical dependence, and the failure probability of the structural system is again computed using a higher-scale system reliability with the member failure probabilities obtained by the lower-scale system reliability and their statistical dependence. Numerical results demonstrate that the proposed approach can provide an accurate and stable reliability assessment of the control performance of the viscous damper system on the system failure. Also, the parametric study of damper capacity on the seismic performance has been performed to demonstrate the applicability of the proposed approach through the probabilistic assessment of the seismic performance improvement of the damper system.

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

  • Shin, Dong Ah;Ji, Gyu Yeul;Oh, Chang Hyun;Kim, Keung Nyun;Yoon, Do Heum;Shin, Hyunchul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.441-447
    • /
    • 2017
  • Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.

Reliability and Validity of Korean Version Northwick Park Neck Pain Questionnaire in Neck Pain Patients (경통 환자들을 위한 한국어판 Northwick Park Neck Pain Questionnaire의 신뢰도와 타당도)

  • Lee, Kwan-Woo;Seo, Hyun-Do;Jung, Kyoung-Sim;Kim, Sang-Hwun;Chung, Yi-Jung
    • Physical Therapy Korea
    • /
    • v.17 no.3
    • /
    • pp.68-76
    • /
    • 2010
  • The purpose of this study was to establish reliability and validity of the Northwick Park Neck Pain Questionnaire (NPQ) translated into Korean for neck pain patients. Sixty-two subjects (35 males, 27 females) with neck pain enrolled in the study. They completed a standardized self-administered questionnaire that included pain intensity, sleeping, sensory at night, duration of symptoms, carrying, reading and watching television, working, social activities, and driving. Reliability was determined by intraclass correlation coefficient (ICC) and Cronbach's alpha by internal consistency. Validity was examined by correlating the NPQ scores to the Visual Analog Scale (VAS) score. Test-retest reliability of the translated versions of the NPQ was good ICC(2,1)=.83 (95%CI=.85~.95). Cronbach's alpha value for NPQ was found to be .87 and this was statistically significant (p<.05). The criterion-related validity coefficients was .75 (p<.01). We concluded that the Korean version NPQ was shown to be a reliable and valid instrument for the assessment of neck pain.

On Some New Stochastic Orders of Interest in Reliability Theory

  • Kayid, M.;El-Bassiouny, A.H.;Al-Wasel, I.A.
    • International Journal of Reliability and Applications
    • /
    • v.8 no.1
    • /
    • pp.95-109
    • /
    • 2007
  • The purpose of this paper is to study new notions of stochastic comparisons and ageing classes based on the total time on test transform order. We give relationships to other stochastic orders and aging classes given previously. Several preservation properties under the reliability operations of random minima and series system are given.

  • PDF