• Title/Summary/Keyword: 9/7 Filter

Search Result 481, Processing Time 0.025 seconds

Fabrication of HTS Microstrip Bandpass Filters using CeO$_2$ buffered YBCO Films grown on ${\alpha}\;Al_2O_3$ substrates (CeO$_2$ 버퍼막과 함께 ${\alpha}\;-Al_2O_3$ 기판 위에 성장된 YBCO 박막을 사용한 HTS Microscrp Bandpass filter의 제작)

  • Jung, Gu-Rak;Chu, Hyeong-Gon;Kang, Joon-Hee;Park, Sang-Jin;Sok, Jung-Hyeon;Lee, Eun-Hong
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.58-62
    • /
    • 1999
  • We fabricated a new hairpin type HTS 2-pole microstrip Bandpass filter to operate at 5.8GHz. The fabrication method was pulsed laser deposition and YBCO films were deposited on ${\alpha}$-A1$_2O_3$ substrates with a CeO$_2$ thin layer as a buffer layer. We developed a new style hairpin type filter by using interdigitide innerpole. Compared to the saute size regular hairpin type filters, our filter had a lower center frequency, bandwidth and loss by an amount of 14.5%, 29.6%, 0.5488dB, respectively. The size of the filters were 13.7${\times}$3.3mm. We did simulations on the several types of band pass filters by using HFSS and serenade. We measured growth rate and Tc of YBCO films grown on CeO$_2$/ ${\alpha}$-A1$_2O_3$ substrates which were rotated while growing films.

  • PDF

Removal of S $O_{2}$ and NO by Dry Sorbent(II) - Efficiency of Cu-Ce and Cu-7Al - (건식법에 의한 이산화황과 산화질소의 제거(II) - Cu-Ce 및 Cu-7Al의 효율 -)

  • 신창섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.288-294
    • /
    • 1993
  • Flue gas control systems for small-scale combustors must be designed to provide highly effective removal of three criteria pollutants (S $O_{2}$, N $O_{x}$ and particulate matter), and must be safe, reliable and small. These requirements make dry, regenerative clean-up process particularly attractive and this paper describes a new concept for integrated pollutant control : a filter comprised of layered, gas permeable membranes that act as an S $O_{2}$ sorbant, a N $O_{x}$ reduction catalyst and a particulate filter. A mixed metal oxide sorbent, Cu-Ce was used as a sorbent/catalyst and the activity was compared with Cu-7Al. The S $O_{2}$ removal eficiency of Cu-Ce was increased with temperature increase up to 500$^{\circ}$C and the catalytic activity for NO was higher than that of Cu-7Al. By the sulfation of Cu-Ce, the reduction activity was increased at the temperature higher than 350$^{\circ}$C. The regeneration of Cu-Ce was very fast and some amount of elemental sulfar was found.

  • PDF

Image Magnification Using Median Filter and Spatial Variation (메디안 필터와 공간 변화량을 이용한 영상 확대)

  • Kwak, Nae-Joung
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.9
    • /
    • pp.72-80
    • /
    • 2007
  • Image magnification is the estimation of a few pixel in images with high quality from a pixel of an image with low resolution and there have been studied many techniques to make images with high quality. In this paper, we propose an image interpolation method using median filter and spatial information. The proposed method makes an interpolating pixel using an average value of a median filtered value and an average value of two pixels correlated with an interpolating pixel tightly. Also we make the magnified image with improved quality to add the directional information of surrounding pixels and the characteristic of ones using average value and max value of spatial variation. We evaluate the performance using PSNR in the quality of enlarged image comparing the proposed method with existing methods. The results show the proposed method improves PSNR than the existing methods and make images preserving the characteristic of original imges.

High-Performance Line-Based Filtering Architecture Using Multi-Filter Lifting Method (다중필터 리프팅 방식을 이용한 고성능 라인기반 필터링 구조)

  • 서영호;김동욱
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.8
    • /
    • pp.75-84
    • /
    • 2004
  • In this paper, we proposed an efficient hardware architecture of line-based lifting algorithm for Motion JPEG2000. We proposed a new architecture of a lifting-based filtering cell which has an optimized and simplified structure. It was implemented in a hardware accommodating both (9,7) and (5,4) filter. Since the output rate is linearly proportional to the input rate, one can obtain the high throughput through parallel operation simply by adding the hardware units. It was implemented into both of ASIC and FPGA The 0.35${\mu}{\textrm}{m}$ CMOS library from Samsung was used for ASIC and Altera was the target for FRGA. In ASIC, the proposed architecture used 41,592 gates for the lifting arithmetic and 128 Kbit memory. For FPGA it used 6,520 LEs(Logic Elements) and 128 ESBs(Embedded System Blocks). The implementations were stably operated in the clock frequency of 128MHz and 52MHz, respectively.

Characteristics of methane production for treatment of brewery wastewater using anaerobic filter (혐기성 필터를 이용한 맥주 폐수 처리에서 메탄 생산 특성)

  • Choi, Young-Ki;Choi, Suk Soon;Chung, Hyung Keun;Jeong, Tae-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.3
    • /
    • pp.29-34
    • /
    • 2011
  • In the present work, the anaerobic filter was used to treat the high concentration of organic wastewater which was produced in the beer production process. During the whole operation periods, wastewater treatment with methane production was effectively performed. The average removal efficiencies of BOD, CODcr, SS, TN and TP were 61.4, 60.9, 31.4, 70.7 and 70.0 %, respectively. Also, methane content in the total gas and methane production amount were 68.8 % and $0.08{\sim}0.77m^3CH_4/kgCOD$, respectively. As a consequence, the practical anaerobic digestion technology developed in this study showed a feasibility of an effective method to treat brewery wastewater with enhancing the methane productivity.

A Convergence Study on Evaluation of Usefulness of Copper Additional Filter in the Digital Radiography System (디지털 방사선장치에서 구리 부가필터의 유용성 평가에 관한 융복합 연구)

  • Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.351-359
    • /
    • 2015
  • This convergence study analyzed the effectiveness of digital radiography system of copper(Cu) filter in the added filtration for the removal of lower energy radiation through dose and image evaluation. We were analyzed from April to June 2015 result of the examination. Cu filter was applied to each non, 0.1, 0.2, 0.3 mm according to change of kV and mAs and doses were evaluated. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of national cancer checkup. The absorbed doses with Cu were lowered by 16-88 % than non-filter but the gaps decreased as kV increased. PSNR were over 30 dB and all significant and CNR and SNR were superior with non-filter but in the qualitative analysis, there were different statistical significant according to each item. The score of 0.1 mm filter was high at pulmonary blood vessel observation and in the 0.3 mm Cu, there were no statistical signigicant except high density and full of air portion. Cu filter can improve image quality with lower radiation dose using better radiation quality and correction power at digital radiography system.

Removal of High Concentration Manganese in 2-stage Manganese Sand Filtration (2단 망간모래여과에 의한 고농도 망간 처리)

  • Kim, Chung H.;Yun, Jong S.;Lim, Jae L.;Kim, Seong S.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.503-508
    • /
    • 2007
  • Small scale D-water treatment plant(WTP) where has slow sand filtration was using raw water containing high concentration of manganese (> 2mg/l). The raw water was pre-chlorinated for oxidation of manganese and resulted in difficulty for filtration. Thus, sometimes manganese concentration and turbidity were over the water quality standard. Two stage rapid manganese sand filtration pilot plant which can treat $200m^3/d$ was operated to solve manganese problem in D-WTP. The removal rate of manganese and turbidity were about 38% and 84%, respectively without pH control of raw water. However, when pH of raw water was controlled to average 7.9 with NaOH solution, the removal rate of manganese and turbidity increased to 95.0% and 95.5%, respectively and the water quality of filtrate satisfied the water quality standard. Manganese content in sand was over 0.3mg/g which is Japan Water Association Guideline. The content in upper filter was 5~10 times more than that of middle and lower during an early operation but the content in middle and lower filter was increased more and more with increase of operation time. This result means that the oxidized manganese was adsorbed well in sand. Rapid manganese sand filter was backwashed periodically. The water quality of backwash wastewater was improved by sedimentation. Thus, turbidity and manganese concentration decreased from 29.4NTU to 3.09NTU and from 1.7mg/L to 0.26mg/L, respectively for one day. In Jar test of backwash wastewater with PAC(Poly-aluminum chloride), optimum dosage was 30mg/L. Because the turbidity of filtrate was high as 0.76NTU for early 5 minute after backwash, filter-to-waste should be used after backwash to prevent poor quality water.

Cyclical Analysis of Construction Business Using Filtering Model (국내 건설경기의 순환변동 분석)

  • Suh, Myong-kyo;Kim, Hyung-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.9
    • /
    • pp.300-309
    • /
    • 2017
  • This paper examines the cyclical fluctuation of 'construction orders' and 'construction investment' using HP filter, Bandpass filter and Beveridge-Nelson decomposition methods. The main results are as follows. As a result of the analysis of the cyclical fluctuation of construction orders, it was analyzed that there were about 7 cyclical fluctuations from 1976 to the first quarter of 2017. Construction orders for cyclical fluctuations peaked in the second quarter of 2015 and turned to a downward trend. On the other hand, construction investment has experienced about 6 cycles of fluctuations during the same period, and it has been rising continuously since the bottom of 3Q12. This is consistent with the general theory that construction orders precede construction investments. In addition, the comparison of the construction orders, construction investment, and GDP amplitude shows that the GDP amplitude is the smallest and stable, and the construction orders have the greatest variation in amplitude. Therefore, construction orders should be adjusted by government policy depending on economic fluctuations.

The Clinical Effects of Leukocyte-Depleting Filter on Cardiopulmonary Bypass (체외순환 시 백혈구 제거필터 사용의 임상효과)

  • 박경택;최석철;최국렬;정석목;최강주
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.454-464
    • /
    • 2001
  • Background: It has been recognized that systemic inflammatory reaction and oxygen free radical formed by activated leukocyte in the procedure of cardiopulmonary bypass(CPB) frequently produce postoperative cardiac and pulmonary dysfunction. The purpose of this study was to evaluate the efficacy of leukocyte-depleting filters in the cardiopulmonary bypass circuit for patients undergoing open heart surgery(OHS). Material and method: The study involved 15 patients who underwent OHS with a Leukoguard-6 leukocyte filter placed in the arterial limbs of the bypass circuit(filter group, n=15) and 15 patients who did not have the filter(control group, n=15). We analyzed the differences between the groups in intraoperative changes of peripheral blood leukocyte and platelet counts, pre- and postbypass changes of malondialdehyde(MDA), troponin-T(TnT), 5'-nucleotidase(5'-NT) in coronary sinus blood, spontaneous recovery rate of heart beat after CPB, pre-and postoperative cardiac index(Cl) and pulmonary vascular resistance(PVR), and the amounts of postoperative bleeding and sternal wound complication. Result: During CPB, total leukocyte count of the filter group(9,567$\pm$ 842/㎣) was significantly less than that of the control group(13,573+1,167/㎣) (p<0.01), but there was no significant difference in platelet count between the groups. Postoperative levels of MDA(3.78+0.32 $\mu$mol/L vs 5.86+0.65 $\mu$mo1/L, p<0.01), TnT(0.40$\pm$0.04 ng/mL vs 0.59$\pm$0.08 ng/mL, p<0.05) and 5'-NT(3.88$\pm$0.61 U/L vs 5.80$\pm$0.90 U/L, p<0.05) were all significantly lower in the filter group than the control group. Postoperative Cl was higher in the filter group than the control group(3.26$\pm$0.18 L/$m^2$min vs 2.75$\pm$0.17 L/$m^2$/min, p=0.05). PVR of the filter group was lower than that of the control group(65.87$\pm$7.59 dyne/sec/cm$^{5}$ vs 110.80+12.22 dyne/sec/cm$^{5}$ , p<0.01). Spontaneous recovery rate of heart beat in the filter group was higher than that in the control group(12 patients vs 8 patients, p<0.05). Postoperative wound infection occurred in one case in the filter group and 4 case in the control group(p<0.05). Postoperative 24 hour blood loss of the filter group was more than that of the control group (614$\pm$107 mL vs 380+71 mL, p=0.05).

  • PDF

Air quality monitoring and evaluation of bag filter performance for removal of fine particulates in roadway tunnels (도로터널 내 공기질 측정과 Bag Filter를 이용한 미세먼지 제거 성능평가)

  • Kim, Beom-Seok;Park, IL-Gun;Jung, Dong-Gyun;Lee, Sang-Don;Hong, Min-Sun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.5
    • /
    • pp.523-531
    • /
    • 2015
  • Air quality was monitored in four roadway tunnels located near Seoul metropolitan area from 7:00AM to 9:00AM. PM10 concentrations range $111{\sim}268{\mu}g/m^3$, which are 2~5 times higher than annual standard $50{\mu}g/m^3$, and PM2.5 concentrations range $35{\sim}65{\mu}g/m^3$, which are 1.5~2.5 times higher than annual standard $25{\mu}g/m^3$. Benzene concentrations range 300~500 ppb, which are 200~300 times higher than 1.5 ppb which is air quality standard. Four-month long term air quality monitoring and test results in one of long tunnels show that PM10 range $30{\sim}400{\mu}g/m^3$ and over 97% of them can be removed by bag filter, effectively. Finally, benzene concentrations range 250~350 ppb.