Multi-layer design of Hybrid method for digital X-ray imaging (디지털 X-ray imaging을 위한 Hybrid 방식의 다층구조 설계)

  • Cho, Sung-Ho;Park, Ji-Koon;Lee, Dong-Gil;Kim, Dae-Hwan;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.75-78
    • /
    • 2003
  • In recent years, there has been keen interest in developing flat panel detectors for all modalities of radiology, including gerneral radiology, fluoroscopy, electronic portal imaging, and mammography. In this paper, we report the new hybrid x-ray detector consisted of ZnS(Ag) photoemission layer and a-Se photoconductor layer to resolve problem of conventional x-ray detector such as the direct detector and the indirect detector. To design the structure of ZnS(Ag)/a-Se detector, the penetrated energy spectrum and absorption fraction was estimated using MCNP 4C code. Also, we carried out the experiment to demonstrate the result of MCNP 4C code. Experimental results showed that the absorption fraction of $500{\mu}m$-ZnS(Ag) film was above 87%, 75% at 60 and 80 kVp. As a results, we can determined the thickness of suitable phosphor and the thickness of photoconductor.

  • PDF

The First Operation of Coal Combustion Test Facility in HANJUNG (HANJUNG 석탄 실험연소로의 초기운전)

  • Jang, G.H.;Chang, I.G.;Jeong, S.Y.;Chon, M.H.;Kim, J.S.
    • 한국연소학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.79-84
    • /
    • 1998
  • In this paper we show design and operation of 1MWth pulverized coal combustion test facility. The test facility is consists of coal feeding system, furnace and flue gas treatment system. The furnace is equipped with a top-fired burner in order to avoid influence of gravity on the coal particles. There are two part of vertical(VP) and horizontal pass(HP) at furnace. We can measure temperature and species of coal flames in vertical pass. Also, there is horizontally arranged section where investigation regarding corrosion and deposit formation will be carried out. The burner of combustor was externally air staging burner(EASB) type made by IFRF. The pulverized high bituminous(Blair athol) coal from Australia was used as fuel, and the particle size less than 80 ${\mu}m$ was 83.4%. Overall excess air ratio was 1.2.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

The Study on the Protection and Actual Condition of Using the Dental X-ray Unit (치과진단용 X선발생장치의 이용 실태 및 방어에 관한 연구)

  • Kang, Eun-Ju;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.43-54
    • /
    • 2000
  • This paper will present the result of research which was done with 201 places on the actual condition of using dental diagnostic radiography unit and the protection of radiography. The purpose of this paper is to comprehend the actual condition of using dental x-ray unit and to protect when they do radiation work. Moreover this paper was completed to prepare basic materials that could be helpful to reduce the exposure from radiation. This paper obtains the following result. 1. On radiation photographing work in the dentist office, 50.3% of dental hygienists treat this job, and 19.2% of assistants, 10.8% of dentists, 5.6% of radiolotechnologists and 4.2% others performed this job. 2. The case that radiation worker is educated about diagnostic radiography safety supervision has been shown 14.4% and uneducated case has been shown 78.1%. 3. The result about the actual condition of using the oral diagnostic radiation per day was that a number of film which take photograph again (less than 1 exposure) was 40.3%. Normal photographing($1{\sim}10$ exposure) was 85.1% which is the highest percentage. Using the bitewing film and occlusal film was 7.0%, and 12.4% respectively. The percent that they use cephalo film and panoramic film was 16.4% 29.8% respectively. 4. Dental intra diagnostic radiography unit made in $1996{\sim}2000$ was 24.9% and the one made in $1991{\sim}1995$ was 19.9%, in $1986{\sim}1990$ was 19.9%, in 1985 was 9.5% according to the answer. On kVp, they use 60 kVp mostly(61.7%) and On mA, they use 10 mA with the highest percent(66.7%). On the dental extra diagnostic radiography units which are used for doing the extra oral radiography, the one made in $1996{\sim}2000$ was 13.4%, in $1991{\sim}1995$ was 9.5%, in $1985{\sim}1990$ was 2.0% according to the answer. They use $71{\sim}80\;kVp$ with 10.9% and $60{\sim}75\;kVP$ with 9.5%. They use less than 10 mA with 19.4% and $11{\sim}15\;mA$ with 2.5%. $16{\sim}20\;mA$ with 1.5%. But the case they exactly do not know how much mA they use or they do not have any mA was 76.6%. 5. General characteristics and the part of protection through the protective equipment by operator are completed with 89.1%. They have shown the similar difference in the relationship with age(p<0.001), experience(p<0.05) and in-patient(p<0.05). 6. When they take photographs of radiation with general quality, how far they keep the proper distance from the cone is as follows, Keeping safe distance is 12.9% according to the answer with the low percent. This result is similar with the difference related in experience(p<0.05) and work(p<0.05), the area of working(p<0.05) and in-patient(p<0.05). 7. The answer about the question-if they hold the tube head when they take photographs with general characteristics is as follows. The answer that they never hold the tube head and cone occupies 62.7% with the highest percent. It is shown the similar difference with age(p<0.05). 8. According to the study that they put on dosimeter with general characteristics is as follows. 64.7% has never put on the dosimester with the highest percent. 33.8% showed similar differences with experience(p<0.05), work(p<0.001), the area of work(p<0.005)and in-patient(p<0.001).

  • PDF

Effects of Cooking Method and Pasteurization Treatment on Instant Thin Rice Porridge Added with Fruits and Vegetables (조리방법 및 살균처리가 과채류를 첨가한 이유식에 미치는 영향)

  • Lee, Hwa-Jin;Kim, Soojung;Bang, Eun;Shin, Haehun;Cho, Hyung-Yong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.4
    • /
    • pp.569-576
    • /
    • 2016
  • This study researched the effects of cooking methods on phytochemical-enriched thin rice porridge (RP) of three colors (red, yellow, and green). Each of the RPs was prepared by three cooking methods and retorted through two-steps (step 1, at $80^{\circ}C$ for 15 min; step 2, at $82^{\circ}C$ for 25 min) for pasteurization. Cooking method (CM) 1 involved heating a mixture of all ingredients while CM 2 involved addition of apple/beet (AB, red), sweet-pumpkin/cabbage (PC, yellow) or vitamin/pear (green) while heating rice flour and glutinous rice flour. CM 3 involved mixing pre-cooked fruits and vegetables with cooked thin RP. The viscosity of RP prepared by CM 1 was lower than those of other RPs (P<0.05). The result of colorimetric a value show that red and green color of AB and VP prepared by CM 2 and CM 3 were most vivid. Contents of phytochemicals and antioxidants were higher when RP was prepared by CM 2 and CM 3 compared to CM 1. ${\Delta}E$ values of PC showed no significant difference before and after pasteurization, whereas AB and VP were significantly different (P<0.05). Antioxidant activity after retorting was not significantly different from those of un-retorted RPs. The results of color, phytochemical content, and antioxidant activity show that CM 2 or CM 3 were considerably better than CM 1, whereas cooking method had no effect after two-step retorting. Therefore, uncomplicated cooking method such as CM 1 or CM 2 are suited for commercial production of RPs.

Consistent Comparison for The Linearity Air Kerma of IEC Standards and Commercial Load in Diagnosing DR Generators (진단용 DR 발생장치에서 IEC 표준규격과 상용부하의 공기커마 직선성에 대한 일관성 비교)

  • Han, Beom-Hui;Kim, Chong-Yeal;Lee, Sang-Ho;Han, Sang-Hyun;You, In-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.389-394
    • /
    • 2012
  • In this study, based on IEC 60601-2-54 standard load conditions presented in the limited interval over the air kerma at the absolute linearity closely evaluated by measuring the X-ray results were as follows: 10 units targeted all Diagnostic X-ray generating device (DR) presented in the IEC 60601-2-54 standard linearity of air kerma emerged as inappropriate, the general evaluation of the dose linearity from four in the top 50% and 80 kVp % of the two measurement series were as irrelevant all the rest from six of the top tube voltage of 50% and 80% of the two measurement series, appeared in all suitable. Presented in IEC 60601-2-54 standard dose linearity testing and conventional linearity tests showed many differences. IEC 60601-2-54 standard linearity in the proposed international standards of air kerma is the recommendation of the existing dose linearity considerably more feasible, and to quantify the amount of radiation as the standard suggested by the standard IEC 60601-2-54 air kerma of a diagnostic X-ray imaging device linearity performance management is considered key elements in the critical appraisal.

Evaluation of Tungsten Blended Filament Shields Made by 3D Printer in Radiography (일반촬영분야에서의 3D 프린터로 제작한 텅스텐 혼합 필라멘트 차폐체의 성능평가)

  • Yoon, Joon;Yoon, Myenog-Seong
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.615-621
    • /
    • 2021
  • In the medical field, radiation provides information for the diagnosis and treatment of diseases. As the use of radiation increases and the risk of exposure increases, interest in radiation protection is also rapidly increasing. Lead shielding material is mainly used, which has a risk of lead poisoning and absorption into the body. Tungsten mixed filament shielding sheets were fabricated with a size of 70 × 70 mm and a thickness of 1, 2, and 4 mm by using a 3D printer. In the general shooting experiment, the thickness of the shielding sheet is 1 ~ 5mm, the tube voltage is 60, 80, 100, 120 kVp and the tube current is 20, 40 mAs. In general photography, Tungsten showed better shielding rate compared to Brass, Copper, and Lead protective tools under all irradiation conditions, and in particular, Tungsten 5 mm showed 100% shielding rate. The 3D-printed tungsten mixed filament shielding is expected to be used as a new shield that can replace the existing lead protection tools as it shows a better shielding rate than the existing lead protection tools in Radiography.

Development of a flexible composite based on vulcanized silicon casting with bismuth oxide and characterization of its radiation shielding effectiveness in diagnostic X-ray energy range and medium gamma-ray energies

  • Ibrahim Demirel;Haluk Yucel
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2570-2575
    • /
    • 2024
  • The study aims to develop a novel, lead-free, flexible and lightweight composite shielding material against ionizing radiation. For this, it was used bismuth oxide (Bi2O3) in RTV-2 silicon matrix. The shielding tests were carried out in both diagnostic X-ray energies and intermediate gamma-ray energy range of up to 662 keV to determine the radiation attenuation properties of this material in terms of attenuation ratio, half value layer, tenth value layer, mean free path and lead equivalency of samples in weight of 30%, 40%, 50% in Bi2O3. In the diagnostic X-ray energy range, half value layer, tenth value layer and lead equivalency (in mm Pb) of the produced samples were measured at 80 and 100 kVp narrow beam conditions according to the requirements of EN IEC 61331-1 standard. The results show that lead equivalent values of the produced novel sheets was measured to be 0.16 mm Pb, corresponding to a 6 mm thickness of the flexible sample when it contains 30% wt. Bi2O3 in RTV matrix. The experimental findings for durability and flexibility also indicated that this new RTV-based flexible, lead -free shielding composite can be used safely for especially for manufacturing aprons, garments and thyroid guards used in mammography, radiology, nuclear medicine and dental applications in practice.

Evaluating polyester resin as a viable substitute for PMMA in computed tomography dosimetry phantoms

  • A. Khallouqi;A. Halimi;O. El rhazouani
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3758-3763
    • /
    • 2024
  • The current study aimed to evaluate the suitability of polyester resin as an alternative material to polymethyl methacrylate (PMMA) for computed tomography (CT) dosimetry phantoms using the GEANT4/GATE Monte Carlo simulation platform. Cylindrical phantoms (32 cm diameter) constructed of polyester resin and PMMA were simulated and compared in terms of atomic composition, effective atomic number, electron density, mass density, and photon interaction mechanisms. Weighted CT dose index (CTDIw) values were calculated for each phantom at 80, 110, and 130 kVp tube voltages based on measurements of CTDI100,c and CTDI100,p. Results demonstrated that the physical properties of polyester closely matched those of PMMA, and the polyester phantom displayed equivalent dosimetric behavior to the PMMA phantom at all tube voltages tested. CTDIw values from the polyester phantom were within 1.4 % of the PMMA phantom across all tube voltages. Conversion coefficients were derived to equate polyester CTDIw values to PMMA dose equivalents. This study found that a polyester resin phantom exhibited radiation dosimetry commensurate with the standard PMMA phantom for CT dose assessment. Consequently, polyester resin represents a viable substitute material when PMMA is unavailable for construction of CT dosimetry phantoms.

Increased Vascular Endothelial Growth Factor in the Ventricular Cerebrospinal Fluid as a Predictive Marker for Subsequent Ventriculoperitoneal Shunt Infection : A Comparison Study among Hydrocephalic Patients

  • Lee, Jeong-Hyun;Back, Dong-Bin;Park, Dong-Hyuk;Cha, Yoo-Hyun;Kang, Shin-Hyuk;Suh, Jung-Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.6
    • /
    • pp.328-333
    • /
    • 2012
  • Objective : The aim of this study is to determine the association between the cerebrospinal fluid (CSF) biomarkers and inflammation, and the predictive value of these CSF biomarkers for subsequent shunt associated infection. Methods : We obtained CSF samples from the patients with hydrocephalus during ventriculoperitoneal (VP) shunt operations. Twenty-two patients were enrolled for this study and divided into 3 groups: subarachnoid hemorrhage (SAH)-induced hydrocephalus, idiopathic normal pressure hydrocephalus (INPH) and hydrocephalus with a subsequent shunt infection. We analyzed the transforming growth factor-${\beta}1$, tumor necrosis factor-${\alpha}$, vascular endothelial growth factor (VEGF) and total tau in the CSF by performing enzyme-linked immunosorbent assay. The subsequent development of shunt infection was confirmed by the clinical presentations, the CSF parameters and CSF culture from the shunt devices. Results : The mean VEGF concentration (${\pm}$standard deviation) in the CSF of the SAH-induced hydrocephalus, INPH and shunt infection groups was $236{\pm}138$, $237{\pm}80$ and $627{\pm}391$ pg/mL, respectively. There was a significant difference among the three groups (p=0.01). Between the SAH-induced hydrocephalus and infection groups and between the INPH and infection groups, there was a significant difference of the VEGF levels (p<0.01). However, the other marker levels did not differ among them. Conclusion : The present study showed that only the CSF VEGF levels are associated with the subsequent development of shunt infection. Our results suggest that increased CSF VEGF could provide a good condition for bacteria that are introduced at the time of surgery to grow in the brain, rather than reflecting a sequel of bacterial infection before VP shunt.