• Title/Summary/Keyword: 765kV

Search Result 258, Processing Time 0.038 seconds

A study of Stability at Initial Energization on 765kV power system (765kV 초기가압 운전계통에서의 안정도 검토)

  • Jang, Kyoung-Chel;Kwak, No-Hong;Park, Jeong-Ho;Kim, Tai-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.96-98
    • /
    • 2002
  • A 765kV Transmission line system plays an important role in delivering the electric power produced at mid-western in Korea. This system will be constructed and operated normally on 2002. By doing the number of test operation in a given time, the reliability on the operation of 765kV transmission system could be secured.

  • PDF

Installation methods of OPGW for 765kV overhead power transmission lines (765kV 가공 송전선로용 OPGW 시설공법)

  • Kwan, Y.G.;Kim, Y.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1641-1643
    • /
    • 1998
  • In recent the maximum voltage of overhead power transmission lines in Korea was upgraded to 765kV. In general a overhead ground wire is installed for protecting overhead power transmission lines from lightning. For the 765kV line, Composite Overhead Ground Wire with Optic Fiber (OPGW) is applied as a overhead ground wire and have a function of the communication line between substations. In this paper, the construction and properties of OPGW, and its installation methods are discribed.

  • PDF

A analysis result on the application of HSGS to the 765 kV transmission line according to it's length (765 kV 계통의 송전선로 거리에 따른 HSGS 적용에 관한 연구)

  • Woo, J.W.;Shim, E.B.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2069-2072
    • /
    • 1999
  • The extended 765 kV system may have severe electrical transients according to the interconnection of transmission lines and have long transmission line over 250 km. So we need to analyze the transient phenomena to confirm the insulation coordination which is designed for 765 kV project step I. In particular, this paper shows the analysis results of secondary arc extinction by HSGS (high speed ground switch) application. The EMTP/MODELS were used to simulation study of secondary arc phenomena. We had confirmed the TRV(transient recovery voltage) and rated current of HSGS which will be used in the KEPCO 765 kV system.

  • PDF

New Technology on Routing and Surveying a 765kV Transmission Line (765kV 송전선로 경과지선정 및 설계측량에 신기술 도입 적용)

  • Lee, Seog-Kyu;Kim, Choon-Gu;Kang, Hee-Kwon;Kim, Jeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.822-824
    • /
    • 1997
  • The routing and surveying a transmission line should be done in advance of its construction. It is getting more difficult to construct transmission line day by day, due to the rapid increase of people's demand resulting from the recent change of social environment and people's consciousness. In order to solve these complicated conditions actively and rationally, it is necessary to be more scientific, objective and computerizable for the routing and surveying of a transmission line. New technologies on routing and surveying a 765kV transmission line are remote sensing, Global Positioning System and Optimal PowerLine system. Thanks to these technologies, there will be a contribution to making sure of the best quality and developing technolo91r of transmission line.

  • PDF

A Study on Environmental Characteristic of Insulators for Ultra High Voltage Using ESDD and NSDD Measurement (초고압애자의 ESDD 및 NSDD 측정을 통한 내환경 특성 연구)

  • Lee, Sang-Yun;Lim, Yun-Seog;Lee, Won-Kyo;Lee, Dong-Il;Shin, Koo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2095_2096
    • /
    • 2009
  • 송배전용 설비에 사용되는 애자의 신뢰성은 전기적인 절연성질과 기계적인 내구성 뿐만 아니라 애자가 설치된 송전선로의 오손에 의한 내환경성에 의해서도 결정될 수 있다. 지금까지 염분 및 분진이 심한 지역에서 오손물이 애자에 미치는 영향에 대한 연구는 전기적, 기계적 신뢰성에 영향을 미치는 오손물질의 성분 분석 등을 통해 저압과 고압의 환경에서 진행되어 왔다.[1] 본 논문에서는 2003년부터 우리나라에서 운전해 오고 있는 765kV 애자오손 신뢰성 검토와 미국 전력연구원(EPRI)에서 수탁받은 765kV 고분자애자 특성연구의 일환으로, 765kV 상용선로에 사용되는 애자류에 대한 장기열화특성을 연구하기 위해 765kV 실증 시험설비를 구축하였다. 아울러, 765kV 애자 장기열화특성 분석을 위한 기초연구로 염분 및 분진 오손도를 측정하여 765kV 환경에서 애자종류에 따른 오손 특성을 검토하였다. 그 결과, RTV 실리콘고무 코팅 애자가 자기 및 유리재 애자에 비해 염분 오손도 면에서 비교적 우수한 특성을 지님을 확인 할 수 있었다.

  • PDF

Analysis of Electrical Safety Level Test for Barehand Work at 765kV Vertical Double Circuit Six Bundle Conductors on the Suspension String Tower Type (765kV 수직2회선 6도체 현수형 철탑에서 직접활선작업의 안전성 평가분석)

  • Kim, Dae-Sik;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.275-278
    • /
    • 2008
  • It has been issued that the necessity of Live line work for 765kV vertical double circuit six bundle conductors transmission line when the characteristics of transmission line, the composition of T/L and near the T/L circumstances etc. Others are considered. The Barehand method of UHV T/L is extremely dangerous work and especially it is directly related with lineman life so it is very dangerous. It should be performed several technology developments for live-line work on the UHV T/L, that should be considered such as the electrical influence on workers near the T/L, development of live-line facilities, guarantee of safety, the technical rules of live-line work, the safe method of live-line work and etc. In order to maintain the 765kV transmission lines safely by barehand work, first of all, we should know the analysis of electrical safety level test in live-line work at 765kV vertical double circuit six bundle conductors on the suspension string tower type.

Flashover Characteristics of Damaged Insulator Strings for Live-line works in 765kV T/L (765kv 송전선로 활선작업을 위한 불량애자 발생 유형별 전기적 섬락특성 분석)

  • Lee, H.K.;Shon, H.K.;Park, M.Y.;Park, I.P.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.31-34
    • /
    • 2005
  • The 765kV transmission line will be maintained by live-line works for efficient operation, In order to maintain the 765kV transmission lines safely by live-line works, lineman have to know flashover characteristics of the insulator strings with damaged insulators. This paper suggests flashover characteristics of the 765kV insulator strings from experimental test results directly.

  • PDF

Analysis of 765kV Transmission Line Fault (765kV신태백#1T/L 고장에 따른 보호시스템 동작 분석)

  • Yoon, J.W.;Kim, B.J.;No, J.H.;Kim, J.Y.;Kim, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.362-364
    • /
    • 2005
  • 전력계통이 대형화되고 복잡 고도화 되는 추세에 따라 전력계통운용에서 송전선로 보호시스템의 중요도가 매우 커지게 되었다. 이에 국내에 적용되기 시작한 765kV 전력계통망은 하위 전압계급 계통망에 미치는 영향이 커지게 되어 765kV 송전선로 보호시스템의 보호 신뢰도 향상은 전력계통을 안정적으로 운전하는 데 있어서 매우 중요한 요소가 되었다. 지난 2004년 11월에 신태백-신가평변전소간 765kV신태백T/L의 상업 운전이 시작되었고 그 상업운전 중 2005년 3월 낙뢰사고에 의한 765kV신태백T/L의 고장이 발생하였다. 이에 본 논문에서는 신태백T/L의 고장이 발생에 대한 보호시스템의 동작 상태를 분석한 사례에 대해서 기술하였다.

  • PDF

A study on appropriateness of the Electrotehnical Regulation for 765 KV Overhead Line (765 kV 가공송전선로 현행 기술기준 적정성 연구)

  • Park, In-Pyo;Kim, Han-Soo;Kim, Gi-hyun;Lee, Joong-hee
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1621-1622
    • /
    • 2015
  • 765 kV 가공송전선로의 안정성 관련으로 전기설비기술기준 제36조제1항 및 동 기준의 판단기준 제126조제4항제7호에 대하여 전선, 애자련, 강재, 송전철탑 및 기초에 대한 현행 기준 적정성을 검토하였다. 검토의 목적은 현재 765 kV 가공송전선로의 내력 크기를 파악하는 것이고 그 과정에서 전기설비기술기준의 개선 사항을 도출하는 것이다. 검토 방법은 현행 전기설비기술기준을 기준으로 했을 때, 한전의 765 kV 송전선로의 여유도(크기)을 파악하고, 또한 해외 기준과 비교를 통하여 우리나라 전기설비기술기준의 적정성을 평가하고자 하였다. 검토 자료는 국내 765 kV Ca-32p형 샘플설계도, 한전 관련 시방서, 국내 전기설비기술기준, 일본 전기설비기술기준 및 일본전기학회의 [송전용 구조물 설계 표준, JEC-127-1979]이다. 향후 다른 철탑형들의 추가 검토와 미국 및 유럽의 기준들과 대비 분석을 진행할 예정이다.

  • PDF

A comparison of calculated and measured values for the electric and magnetic field of 765 kV overhead transmission line (765kV 송전선로 전자계 예측계산 및 실측치 비교)

  • Maeng, JongHo;Lee, HoKwon;Lee, HyunJoong;Ahn, HunHeeSung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1259-1260
    • /
    • 2015
  • 한국의 송전선로는 154kV, 345kV, 765kV로 분류할 수 있으며, 이 중 765kV급 송전선로는 2000년대 초반 도입된 이래 대규모 발전단지와 부하밀집 지역을 잇는 주요한 설비로 자리잡아 현재까지 안정적으로 운용되고 있다. 그러나 최근 건강을 중요시 여기는 사회적 트렌드와 전자계에 대한 일반 대중들의 관심 증가로 밀양 765kV 송전선로의 건설이 지연되어 적기 건설 및 운영에 어려움을 겪고 있다. 이러한 문제를 해소하기 위해 송 변전설비 주변지역의 보상 및 지원에 관한 법률이 2014년 7월 29일부로 시행되어 전력설비 인근 지역에 거주하는 주민들의 보상을 법으로 보장하고, 원활한 관련 문제 해소를 위해 다양한 Risk Communication 방안이 검토되고 있다. 또한 송전선로에서 주로 이슈가 되는 전기환경영향에 대해 장기 전기환경 측정시스템을 구축하여 상용선로에서 1년 이상의 전기환경 DB를 집록할 예정이다. 전력설비의 전기환경은 크게 전파장해, 소음, 전자계로 구분할 수 있으며 참고 데이터로 기상요소를 측정하는데 장기 전기환경 측정시스템에서는 이 모든 전기환경 데이터를 취득할 수 있는 설비를 갖추고 있으며, 본 논문에서는 구축된 설비를 간다하게 설명하고 해당 부지에서의 전자계 값을 모의하고 실측한 결과를 수록하였다.

  • PDF