• 제목/요약/키워드: 765kV

검색결과 258건 처리시간 0.02초

765kV 시험선로를 이용한 전기환경장해 특성연구 (Study on Electrical Environmental Obstacle Using a 765kV Double Circuit Test Line)

  • 김정부;조성배;신구용;이동일;양광호;안희성;배정효;구자윤;민원석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1517-1519
    • /
    • 1994
  • This paper describes electrical environmental study of a 765kV double circuit test line. Corona performance on several candidate conductor bundles has been investigated in the corona cage (single phase simulation facility) since 1984. We have known that six RAIL conductor bundle is the most suitable for the 765kV transmission Line, [3] To investigate electrical environmental impact of the future commerciale line, we build a full sacle 765kV test line in 1993. The test results of Audible Noise, Radio Interference, TV Interference from August, 1993 to Jan. 1994 were measured as $48.7[dBA](L_{50})$. $57.4[dB{\mu}V/m]$(Fair weather, $L_{50})$. $14.5[dB${\mu}$V/m]$(Fair weather, $L_{50}$). We have found that the Audible Noise data were very close to the predicted(48.5 [dBA]) by BPA Corona and Field Effects Computer program, however, the RI and TVI data were much higher than predicted(42 [dBmV/m], $7.9[dB{\mu}V/m)$ by the BPA program. We have investigating the reason of the difference. In the constructing of full scale test line, we developed the tubular tower, 765kV test transformer and hardwares of 765kV transmission line insulator strings. Also we will investigate the effects of plants under the 765kV test Line.

  • PDF

765kV 변전소 시운전시험 분석 (Analysis of 765kV Substation Trial Test Result)

  • 윤장완;전명렬;오세일;김명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.81-82
    • /
    • 2006
  • 본 논문에서는 765kV 변전소 건설시 최초로 도입된 시운전 시험을 중심으로 기술하였다. 시운전 시험은 765kV 초기 가압 및 상업 운전에 대비하여 사전에 문제점을 도출하고, 이에 대한 대책을 강구하기 위한 목적으로 시행되었다. 2004년에 시행한 신가평변전소에 대한 전력계통시험분야의 시운전시험을 중심으로 기술하였다. 기존의 345kV전력설비와 765kV전력설비(800kVGIS, 765kV7M.Tr)의 보호방식 차이에 따른 시험 방법, 시험 시 발생된 문제점 및 시험 결과에 대해 기술하였다.

  • PDF

765kV 교류 송전선로의 가청소음계산 예측식개발(I) (Predicting formula development of audible noise on a 765kV AC transmission line(I))

  • 이동일;구자윤
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.612-615
    • /
    • 1996
  • Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500kV and above. Therefore this paper describes audible noise characteristics of 6 X 480mm conductor bundle in KEPRI 765kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765kV transmission Line was developed using this results.

  • PDF

765kV 시험선로에서의 전자파 장해에 관한 연구 (A Study on the Electromagnetic Interference from 765kV Test Line)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • 한국전자파학회논문지
    • /
    • 제7권1호
    • /
    • pp.36-42
    • /
    • 1996
  • 일반적으로 500kV 이상의 초고압 전력선에서 발생하는 전자파 장해는 전력선 부근에서 AM라디오 방송대역과 저초단파(VHF)대역의 TV 방송수신에 영향을 미치는 것으로 알려져 있다. 따라서 본 논문에서는 전북 고창에 건설된 세계 최초의 765kV 수직배열 2회선 시험선로에서의 장기 실증시험 결과를 이용해 차기 송전 전압으로 결정된 765kV 송전선로의 후보도체방식 중의 하나인 Rail($480mm^{2}$) $\ast$ 6B의 환경적응성을 검증하였다. 이 결과에 의하면 전자파장해 측면에서 Rail $\ast$ 6B 도체방식은 765kV 송전선로 도체방식으로 적합한 것으로 분석되었다.

  • PDF

송전전압 격상:765kV 초고압 송전

  • 김정부
    • 전기의세계
    • /
    • 제46권7호
    • /
    • pp.22-24
    • /
    • 1997
  • 세계에서 처음으로 건설되는 765kV 2회선 송전선로의 설계 및 사업 개요, 기기개발, 공법개발 및 건설장비 개발에 대하여 간단히 소개하였다. 1970년대 345kV 송전선로 건설때와는 달리 우리 기술로 설계하고 기기개발하여 초기 사업부터 국산화 기기를 사용할 수 있었다는 데에 기술개발의 의의가 있다. 2000년대 초 765kV 송변전 설비를 운용함으로서 전력수급에 원활한 계통운용을 할 수 있으리라 믿는다. 또한 이의 건설을 계기로 우리나라 중전기 사업의 기술향상을 가져왔으며 해외 500kV 및 765 kV 송.변전 사업에 적극적으로 참여할 수 있는 계기가 되리라고 믿는다. 765kV 계통운용등 미진한 분야에 대하여는 지속적으로 연구하여야 하고 기기 제작에는 철저한 개발 시험을 거치고 건설에는 정밀한 시공과 공기준수를 위하여 부단히 노력하여야 되리라고 믿는다.

  • PDF

765kV 초기가압 운전계통에서의 안정도 검토 (A study of Stability at Initial Energization on 765kV power system)

  • 곽노흥;장경철;김용학;박정호;김태옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.227-230
    • /
    • 2002
  • A 765kV Transmission line system plays an important role in delivering the electric power produced at mid-western in Korea. This system will be constructed and operated normally on 2002. By doing the number of test operation in a given time, the reliability on the operation of 765kV transmission system could be secured.

  • PDF

765kV 비연가 송전계통 과도 특성에 관한 고찰 (A Study on the Transient Characteristics in 765kV Untransposed Transmission Systems)

  • 안용진;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권7호
    • /
    • pp.397-404
    • /
    • 2004
  • This paper describes a study of transient characteristics in 765kV untransposed transmission lines. As the 765(kV) system can carry bulk power, some severe fault on the system nay cause large system disturbance. The large shunt capacitance and small resistance of 765kv transmission line make various difficulties for its protection. These problems including current difference between sending and receiving terminals on normal power flow, low order harmonic current component in fault current and current transformer saturation due to the long DC time constant of the circuit etc. must be investigated and solved. The analysis of transient characteristics at sending terminal has been carried out for the single phase to ground fault and 3-phase short fault, etc. The load current, charging current in normal condition and line flows, fault current, THD(Total Harmonic Distortion) of harmonics, time constants have been analysed for the 765kV untransposed transmission line systems.

765kV 송전선로 건설사업 추진현황

  • 김정호
    • 전기기술인
    • /
    • 제189권5호
    • /
    • pp.65-72
    • /
    • 1998
  • 21세기는 삶의 질 향상과 산업의 선진국형으로의 발전, 그리고 생활형태의 자동화, 정보화 등으로 전력수요가 급격히 증가할 것으로 예상되어 이에 대처하고자 765kV 송전선로 건설을 추진하고 있다. 765kV 송전선로는 345kV 송전선로의 약 5배에 해당하는 전력 수송능력을 가지고 있어 국토가 협소하고 발전단지와 수요지가 멀리 떨어져 있는 우리나라에 적합한 설비라 할 수 있다.

  • PDF

765kV 송전선로의 전기적 및 기계적 소음고찰 (Electrical and Mechanical Noise Study of the 765kV Transmission Line)

  • ;이동일;구자윤
    • 소음진동
    • /
    • 제6권1호
    • /
    • pp.89-95
    • /
    • 1996
  • 송전전압이 500kV 이상이 되면, 송전도체의 코로나 방전에 의해 발생되는 가청소음, 험소음이 송전선로의 도체 선정에 중요한 요소가 되며 또한 바람에 의한 철탑과 도체의 풍소음도 발생한다. 본 논문은 세계최초로 765kV 2회선 교류 송전선을 개발하기 위해 건설한 한전 전력연구웜 765kV 시험송전선로의 상당 480mm$^{2}$ 도체 6가닥으로 구성된 송전선 구성에서 가정소음, 험소음, 풍소음의 통계적인 분석 결과를 나타내었다. 분석결과를 보면 6-480mm$^{2}$ 도체와 철탑구성이 가청소음 설계목표치인 50dB(A)를 만족함을 알 수 있다.

  • PDF

765kV 변전소 지진계측시스템 구축과 관측자료 예비분석 (765kV Substations Earthquake Monitoring System and Preliminary Data Analysis)

  • 박동희;연관희;서용표;김병철
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.56-63
    • /
    • 2006
  • Facilities of 76skV Substation(S/S) play an important role in electric power supply grids. Various power facilities of 765kV S/S might be damaged enormously if a strong earthquake occurs. In an effort to mitigate possible earthquake disasters, KEPRI (Korea Electric Power Research Institute) set forth plans to verify seismic safety of the facilities of 765kV S/S. To accomplish the task, an earthquake monitoring systems is constructed at four 765kV S/S sites(Shin-AnSung, Shin-TaeBaek, Shin-SeoSan and Shin-GaPyung). Data from these earthquake monitoring stations are being transmitted via satellite communication. Currently, KEPRI is operating an earthquake monitoring system in freefield of Shin-SeoSan S/S (NSS) tentatively, Also, the data from NSS is preliminarily analyzed using the horizontal to vertical (H/V) spectrum ratio method. The method of H/V spectrum ratio has been used to infer site amplification without previous knowledge of near surface geology. The results of data analysis shorts good S/N ratio and amplification of 20-25 Hz by site effect. In the near future, the accumulated data is expected to provide a basis for assessing and predicting any damages to integrity of 765kV S/S facilities by earthquakes.

  • PDF