• 제목/요약/키워드: 6D-Motion

검색결과 572건 처리시간 0.027초

A development of the automated system for adjusting the 6 D.O.F circular fixator

  • Jung, Sang-Gil;Park, Bum-Seok;Sim, Hyung-Joon;Jang, Jae-Ho;Han, Chang-Soo;Han, Jung-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1642-1647
    • /
    • 2004
  • In this article, we present the development of the automated system for adjusting the 6 D.O.F circular fixator. The system includes scheduling software to adjust the Hexapod Circular Fixator (HCF) and an automated strut system with the ability of the multiple synchronized motion. HCF was designed to control a 6 degree-of-freedom Ilizarove fixator and it's mechanism is known as the Stewart Platform. HCF scheduler evaluates each value of altered length of the HCF struts to correct the complex skeletal deformity by using the X-ray data of the patient. The data of HCF scheduler feed into the automated strut system which be able to provide the scheduled adjustment and the automated strut is synchronized by input data.

  • PDF

Degradation of 0.2PMN-0.8PZT Multilayer Ceramic Actuators

  • Song, Jae-Sung;Koh, Jung-Hyuk;Jeong, Soon-Jong;Wee, Sang-Bong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권1호
    • /
    • pp.6-9
    • /
    • 2005
  • Aging characteristics of 0.2PMN-0.8PZT multilayer ceramic actuators (MCA) has been investigated by applying both triangular wave function for unpoled and unipolar wave for poling. P-E hysteresis loops of the MCA had been distorted after about 90 million cycles running in triangular wave function. Effective electromechanical coupling coefficient was calculated in resonant and anti resonant frequencies. And pseudo-piezoelectric constant $d_{33}$ was also estimated from the strain versus electric field characteristics. The crack growth of MCA was clearly observed along to the boundary between electrode and inactive area. That results were thought due to the internal tensile stress came from both actuation of $d_{33}$ mode and motion of Poisson ratio.

청각장애우의 언어교육을 위한 캐릭터 구화 애니메이션 시스템 (A Character Speech Animation System for Language Education for Each Hearing Impaired Person)

  • 원용태;김하동;이말례;장봉석;곽훈성
    • 디지털콘텐츠학회 논문지
    • /
    • 제9권3호
    • /
    • pp.389-398
    • /
    • 2008
  • 청각장애우들과 일반인과의 커뮤니케이션을 위한 구화체계가 연구되고 있지만 사회적인 무관심과 시장성의 결여로 기존 교사가 일일이 지도하는 비효율적 교육 방식으로 진행되고 있다. 이러한 단점을 극복하기위하여 3차원 애니메이션 및 디지털 테크놀로지 기술을 활용한 콘텐츠를 개발이 필요하다. 캐릭터 제작을 위한 표준얼굴 및 표준구형 조사를 위해 국내 서울 및 경기지역 초등학교 $3{\sim}6$학년 학생의 얼굴관련 데이터를 충분히 수집하여 해당 연령층 학생들의 얼굴과 구형에 대한 표준을 도출하였다. 이러한 자료는 청각장애우를 위한 콘텐츠개발의 기초자료 뿐 아니라 실질적으로 적용할 수 있는 표준치수 및 표준 형태를 제공할 수 있다. 캐릭터 구화 애니메이션 시스템은 3D캐릭터 애니메이션을 응용하여 대화를 이해하고 자신의 의사표현을 교육하는 시스템으로 3D 기술과 모션캡쳐를 접목시켜 가정 및 특수교육 기관에서 언어교육이 필요한 청각장애아동들의 언어교육에 효과적인 학습을 지원한다.

  • PDF

Comparative Study between ZOOMit and Conventional Intravoxel Incoherent Motion MRI for Assessing Parotid Gland Abnormalities in Patients with Early- or Mid-Stage Sjögren's Syndrome

  • Qing-Qing Zhou;Wei Zhang;Yu-Sheng Yu;Hong-Yan Li;Liang Wei;Xue-Song Li;Zhen-Zhen He;Hong Zhang
    • Korean Journal of Radiology
    • /
    • 제23권4호
    • /
    • pp.455-465
    • /
    • 2022
  • Objective: To compare the reproducibility and performance of quantitative metrics between ZOOMit and conventional intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) in the diagnosis of early- and mid-stage Sjögren's syndrome (SS). Materials and Methods: Twenty-two patients (mean age ± standard deviation, 52.0 ± 10.8 years; male:female, 2:20) with early- or mid-stage SS and 20 healthy controls (46.9 ± 14.6 years; male:female, 7:13) were prospectively enrolled in our study. ZOOMit IVIM and conventional IVIM MRI were performed simultaneously in all individuals using a 3T scanner. Quantitative IVIM parameters - including tissue diffusivity (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) - inter- and intra-observer reproducibility in measuring these parameters, and their ability to distinguish patients with SS from healthy individuals were assessed and compared between ZOOMit IVIM and conventional IVIM methods, appropriately. MR gland nodular grade (MRG) was also examined. Results: Inter- and intra-observer reproducibility was better with ZOOMit imaging than with conventional IVIM imaging (ZOOMit vs. conventional, intraclass correlation coefficient of 0.897-0.941 vs. 0.667-0.782 for inter-observer reproducibility and 0.891-0.968 vs. 0.814-0.853 for intra-observer reproducibility). Significant differences in ZOOMit f, ZOOMit D*, D*, conventional D*, and MRG between patients with SS and healthy individuals (all p < 0.05) were observed. ZOOMit D* outperformed conventional D* in diagnosing early- and mid-stage SS (area under receiver operating curve, 0.867 and 0.658, respectively; p = 0.002). The combination of ZOOMit D*, MRG, and ZOOMit f as a new diagnostic index for SS, increased diagnostic area under the curve to 0.961, which was higher than that of any single parameter (all p < 0.01). Conclusion: Considering its better reproducibility and performance, ZOOMit IVIM may be preferred over conventional IVIM MRI, and may subsequently improve the ability to diagnose early- and mid-stage SS.

Relationship between Center of Pressure and Local Stability of the Lower Joints during Walking in the Elderly Women

  • Ryu, Ji-Seon
    • 한국운동역학회지
    • /
    • 제27권2호
    • /
    • pp.133-140
    • /
    • 2017
  • Objective: The purpose of this study was to determine the relationship between center of pressure (CoP) and local stability of the lower joints, which was calculated based on approximate entropy (ApEn) during walking in elderly women. Method: Eighteen elderly women were recruited (age: $66.4{\pm}1.2yrs$; mass: $55.4{\pm}8.3kg$; height: $1.56{\pm}0.04m$) for this study. Before collecting data, reflective marker triads composed of 3 non-collinear spheres were attached to the lateral surface of the thigh and shank near the mid-segment to measure motion of the thigh and shank segments. To measure foot motion, reflective markers were placed on the shoe at the heel, head of the fifth metatarsal, and lateral malleolus, and were also placed on the right anterior-superior iliac spine, left anterior-superior iliac spine, and sacrum to observe pelvic motion. During treadmill walking, kinematic data were recorded using 6 infrared cameras (Oqus 300, Qualisys, Sweden) with a 100 Hz sampling frequency and kinetic data were collected from a treadmill (Instrumented Treadmill, Bertec, USA) for 20 strides. From kinematic data, 3D angles of the lower extremity's joint were calculated using Cardan technique and then ApEn were computed for their angles to evaluate local stability. Range of CoP was determined from the kinetic data. Pearson product-moment and Spearman rank correlation coefficient were applied to find relationship between CoP and ApEn. The level of significance was determined at p<.05. Results: There was a negative linear correlation between CoP and ApEn of hip joint adduction-abduction motion (p<.05), but ApEn of other joint motion did not affect the CoP. Conclusion: It was conjectured that ApEn, local stability index, for adduction/abduction of the hip joint during walking could be useful as a fall predictor.

손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스 (Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture)

  • 장익규
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권3호
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

A Method for Estimating the Lung Clinical Target Volume DVH from IMRT with and without Respiratory Gating

  • J. H. Kung;P. Zygmanski;Park, N.;G. T. Y. Chen
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.53-60
    • /
    • 2002
  • Motion of lung tumors from respiration has been reported in the literature to be as large as of 1-2 cm. This motion requires an additional margin between the Clinical Target Volume (CTV) and the Planning Target Volume (PTV). While such a margin is necessary, it may not be sufficient to ensure proper delivery of Intensity Modulated Radiotherapy (IMRT) to the CTV during the simultaneous movement of the DMLC. Gated treatment has been proposed to improve normal tissues sparing as well as to ensure accurate dose coverage of the tumor volume. The following questions have not been addressed in the literature: a) what is the dose error to a target volume without gated IMRT treatment\ulcorner b) what is an acceptable gating window for such treatment. In this study, we address these questions by proposing a novel technique for calculating the 3D dose error that would result if a lung IMRT plan were delivered without gating. The method is also generalized for gated treatment with an arbitrary triggering window. IMRT plans for three patients with lung tumor were studied. The treatment plans were generated with HELIOS for delivery with 6 MV on a CL2100 Varian linear accelerator with a 26 pair MLC. A CTV to PTV margin of 1 cm was used. An IMRT planning system searches for an optimized fluence map ${\Phi}$ (x,y) for each port, which is then converted into a dynamic MLC file (DMLC). The DMLC file contains information about MLC subfield shapes and the fractional Monitor Units (MUs) to be delivered for each subfield. With a lung tumor, a CTV that executes a quasi periodic motion z(t) does not receive ${\Phi}$ (x,y), but rather an Effective Incident Fluence EIF(x,y). We numerically evaluate the EIF(x,y) from a given DMLC file by a coordinate transformation to the Target's Eye View (TEV). In the TEV coordinate system, the CTV itself is stationary, and the MLC is seen to execute a motion -z(t) that is superimposed on the DMLC motion. The resulting EIF(x,y)is inputted back into the dose calculation engine to estimate the 3D dose to a moving CTV. In this study, we model respiratory motion as a sinusoidal function with an amplitude of 10 mm in the superior-inferior direction, a period of 5 seconds, and an initial phase of zero.

  • PDF

요가용 3차원 무릎보호대 개발 및 평가 (Development of the 3D Knee Protector for Yoga)

  • 정현주;이희란;정인희
    • 한국의류학회지
    • /
    • 제46권4호
    • /
    • pp.657-671
    • /
    • 2022
  • This study aims to develop three dimensional (3D) yoga knee protectors that provide excellent wearing comfort. Three types of pads were modeled using 3D human data: two types of 3.0-cm-wide pads separated into top and bottom with thicknesses of 0.1 cm (TPU-1: A) and 0.2 cm (TPU-2: B); and one type with three 0.2-cm-thick separated panels (TPU-S: C). Based on these models, five knee protectors were developed using 3D patterning and 3D printing. Types A, B, and C were integrated with 0.6-cm neoprene pads. Type D was fabricated with a donut-shaped 0.6-cm neoprene pad inserted, while Type E consisted of two discrete 0.6-cm neoprene pads embedded in the protector's upper and lower sides. Wearing comfort was evaluated in terms of fit, pressure, and cushioning while in a standing and kneeling position and while in motion. The findings suggest that the fabricated knee protectors were evaluated as comfortable to the individuals with knee pain, rather than those without knee pain. The individuals with knee pain preferred the soft pads made of neoprene positioned around the knee (NEO-S: E), while those without knee pain favored the cushioned pads with a pattern structure maintained by thin 3D-printed pads (TPU-1: A).

Hadamard 변환을 이용한 고속 2차원 DCT에 관한 연구 (A Study on Fast 2-D DCT Using Hadamard Transform)

  • 전중남;최원호;최성남;박규태
    • 한국통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.221-231
    • /
    • 1990
  • 본 논문에서는 예측오차의 분포와 비트할당표를 이용하여 계산량을 줄이는 방법으로 직접 2차원 WHT를 계산한 다음 상수행렬을 곱함으로써 2차원 DCT 를 계산하는 방법을 제안하였다. 이 2차원 고속 DCT 알고리즘은 곱셈이 마지막 단계에 집중되어 있으며, 따라서 변환계수 중에서 양자화 과정에서 제외되는 변환계수의 수에 비례하여 계산량을 줄일 수 있는 특징이 있다. 계산량 비교를 위하여, 예측오차에 대한 비교할당표에 할당된 DCT계수만을 구하고자 할 때의 계산량을 산출한 결과, 제안한 방식은 변환부호화에 할당된 화소당 평균 비트율이 0.6비트 이하일 때, 기존의 알고리즘 중에서 가장 계산량이 적은 고속 DCT 알고리즘 보다 계산량이 적게 되어, 변환부호화의 계산량 감축에 기여할 수 있음을 확인하였다.

  • PDF

비파괴검사를 위한 검출기 이동 방법과 논블라인드 디컨볼루션 순차 적용에 따른 이미지 해상도 증가 연구 (A Study on Image Resolution Increase According to Sequential Apply Detector Motion Method and Non-Blind Deconvolution for Nondestructive Inspection)

  • 소경재;김병수;엄원영;이대희
    • 한국군사과학기술학회지
    • /
    • 제23권6호
    • /
    • pp.609-617
    • /
    • 2020
  • Non-destructive inspection using X-rays is used as a method to check the inside of products. In order to accurately inspect, a X-ray image requires a higher spatial resolution. However, the reduction in pixel size of the X-ray detector, which determines the spatial resolution, is time-consuming and expensive. In this regard, a DMM has been proposed to obtain an improved spatial resolution using the same X-ray detector. However, this has a limitation that the motion blur phenomenon, which is a decrease in spatial resolution. In this paper, motion blur was removed by applying Non-Blind Deconvolution to the DMM image, and the increase in spatial resolution was confirmed. DMM and Non-Blind Deconvolution were sequentially applied to X-ray images, confirming 62 % MTF value by an additional 29 % over 33 % of DMM only. In addition, SSIM and PSNR were compared to confirm the similarity to the 1/2 pixel detector image through 0.68 and 33.21 dB, respectively.