• Title/Summary/Keyword: 60Hz

Search Result 1,303, Processing Time 0.031 seconds

Analysis of Characteristics of Horizontal Response Spectrum of Ground Motions from 19 Earthquakes (국내 관측자료를 이용한 수평 응답스펙트럼 특성 분석)

  • Kim, Jun-Kyoung
    • Tunnel and Underground Space
    • /
    • v.20 no.6
    • /
    • pp.399-407
    • /
    • 2010
  • The horizontal response spectra using the observed ground motions from the recent more than 19 macro earthquakes were analysed and then were compared to both the seismic design response spectra (Reg Guide 1.60), applied to the domestic nuclear power plants, and the Korean Standard Design Response Spectrum for general structures and buildings (1997). 130 horizontal ground motions, without considering soil types, were used for normalization with respect to the peak acceleration value of each ground motion. The results showed that response spectrum have strong dependency on epicentral distance. The results also showed that the horizontal response spectra revealed much higher values for frequency bands above 5 Hz than Reg. Guide (1.60). The results were also compared to the Korean Standard Response Spectrum for the 3 different soil types and showed that the vertical response spectra revealed much higher values for the frequency bands below 0.3 second than the Korean Standard Response Spectrum (SD soil condition). These spectral values dependent on frequency could be related to characteristics of the domestic crustal attenuation and the effect of each site amplification. However, through the qualitative improvements and quantitative enhancement of the observed ground motions, the conservation of horizontal seismic design response spectrum should be considered more significantly for the frequency bands above 5 Hz.

Power Transmission by High Voltage Direct Current(HVDC)

  • Andersen, B.R.
    • KIPE Magazine
    • /
    • v.6 no.4
    • /
    • pp.12-20
    • /
    • 2001
  • 지난 세기의 시작 아래로, 50Hz 또는 60Hz로 운영되는 교류는 저력 계통 망의 송전과 배전에 지배적으로 사용되는 방법이었다. 그러나, 일반적으로 HVDC라 불리는, 고압 직류 송전은 매우 긴 장거리 선로에 대한 경제적 해법을 제공하고 이미 실현 비 동기화 AC계통 사이의 연계를 가능케 하였다. 50MW에서 6300MW까지의 각 Scheme별로 건설된 직류송전은 전세계적으로 총 59GW HVDC Scheme이 설치되어있으며, 이 기술을 위해서는 더 많은 응용이 고려되고 있다. 본 원고에서는 HVDC의 특성, 포함된 설비, HVDC의 사용 그리고 기술 발전의 요약을 기술하였다.

  • PDF

Influence of Filler Shape on Dielectric & Electric Charge-Discharge Properties of Filled Epoxy Resin (에폭시 수지의 유전특성.충방전특성에 미치는 충전제 형상의 영향)

  • 이성일;박일규;류성림;주인규
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.81-84
    • /
    • 2000
  • In this paper, we have the investigated the Influence of Filler Shape on Dielectric & Electric Charge-Discharge Properties of Filled Epoxy Resin. In the low frequency range from 50Hz to a few kHz, the maginitude of tan$\delta$ become larger in the order, NON, RAS, SAS, SCS. The electrical Discharge of RAS measured for 60 min, decreased after 10$^2$∼10$^3$.

  • PDF

Vibration Analysis of a Generator-Stator Core Under Electromagnetic Excitation (전자기력에 의한 발전기 고정자 코어의 진동 해석)

  • 김철홍;주영호;박종포
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.747-753
    • /
    • 1999
  • This paper presents results of vibration analysis of a generator-stator core for 500 MW fossil power plant. A finite element analysis using a commercial S/W is performed to estimate alternating electromagnetic forces, mainly of 120 Hz in 60 Hz machines, acting on the core, and then to calculate forced response of the core. Results are compared with design requirements.

  • PDF

A study on the design of LCD BLU Scanning Inverter (LCD BLU Scanning Inverter 개발에 관한 연구)

  • Kim, Hyun-Sik;Lim, Young-Cheol;Yun, Chang-Sun;Huh, Dong-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.556-558
    • /
    • 2008
  • 최근 LCD가 가지는 단점으로 움직이는 동화상 응답속도 MPRT(Motion Picture Response Time) 개선에 대해 기업에서 많은 연구가 수행되고 있다. 이 가운데 최근 LCD 화면 재생주파수를 60Hz에서 120Hz로 가속 시키고 있는 가운데 본 논문에서는 MPRT개선을 위한 Scanning 인버터를 제작 하여 그 성능을 검증 하였다.

  • PDF

A study on the dynamics of a turbine-meter-type flowmeter for hydraulic systems

  • Yokota, Shinichi;Kim, Do-Tae;Suzuki, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.60-65
    • /
    • 1994
  • In this study, the dynamic characteristics of a turbine-meter-type flowmeter is investigated by making use of the remote instantaneous flow rate measurement method (RIFM). The results of the frequency response test indicated that the gain of the flow rate of the turbine-meter-type flowmeter relative to the flow rate of the RIFM was nearly unity up to 40Hz and the phase lag of the flow rate became 90 degrees at 70Hz.

  • PDF

Influence of Filler Shape on Dielectric & Electric Charge-Discharge Properties of Filled Epoxy Resin (에폭시 수지의 유전특성.충방전특성에 미치는 충전제 형상의 영향)

  • 이성일;박일규;류성림;주인규
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.81-84
    • /
    • 2000
  • In this paper, we have the investigated the Influence of Filler Shape on Dielectric & Electric Charge-Discharge Properties of Filled Epoxy Resin. In the low frequency range from 50Hz to a few kHz, the magnitude of tan$\delta$ become larger in the order, NON, RAS, SAS, SCS. The electrical Discharge of RAS measured for 60 min, decreased after 10$^2$∼10$^3$.

  • PDF

A Study on Stair Case Wave PWM Inverter System by Microprocessor (마이크로프로세서에 의한 계단파 PWM 인버어터 시스템에 관한 연구)

  • 이종수;김영길;이철우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.2 no.4
    • /
    • pp.70-74
    • /
    • 1988
  • 계단파 5전위 PWM 출력전압은 CTI회로를 구성하는 스위칭 소자의 구동신호에 의하여 이루어진다. 이 CTI회로를 구동시키기 위한 구동신호는 Natural Sampling 방식의 변조신호를 10-6 범위인 변환 오차로 디지틀 변환하고, 이 신호의 데이터에 의한 마이크로프로세서 운전 시스템을 구성하였다. 이 방식에 의하면, CTI회로의 V/F제어를 위한 1[Hz]~60[Hz]의 시스템에 소요되는 메모리의 용량은 어드레스 카운터방식에 비하여 0.8%이었다.

  • PDF

Simultaneous Measurements of Polarization and Strain under Electric Field Ferroelectric Ceramics (강유전체 세라믹스에서의 전계인가에 따른 Polarization 및 Strain의 동시 측정)

  • Park, Jae-Hwan;Hong, Guk-Seon;Park, Sun-Ja
    • Korean Journal of Materials Research
    • /
    • v.6 no.2
    • /
    • pp.221-227
    • /
    • 1996
  • 60Hz의 교류전계를 사용하는 종래의 Sawyer-Tower회로를 응용하여 0.1Hz의 직류 개념(quasi-DC)의 전계를 이용한 polarization과 strain의 동시 측정을 실시하였다. 측정의 대상으로는 강유전체로서 압전변형을 보이는 재료 중 가장 대표적인 PZT 계와 완화형 강유전체로서 전왜변형을 보이는 재료 중 가장 대표적인 PZT계와 완화형 강유전체로서 전왜변형을 보이는 재료 중 가장 대표적인 PMN계로 하였다. 0.1Hz한 주기의 전계 인가로 이력곡선을 측정할 수 있어서 시편의 발열을 크게 억제할 수 있었고 정확한 온도에서의 측정이 가능하였다. 또한 양방향 전계뿐 아니라 단방향 전계, 바이어스 전계도 인가할 수 있기 때문에 종래의 Sawyer-Tower 방법에서는 얻을 수 없는 강유전성에 관한 다양한 정보를 얻을 수 있었다. 이 방법은 또한 0.1Hz의 전계 하에서 얻을 수 없는 강유전성에 관한 다양한 정도를 얻을 수 있었다. 이 방법은 또한 0.1Hz의 전계 하에서 이력곡선이 측정되는 한 주기 동안에 시편에 부착된 스트레인 게이지를 통해 전계인가에 따른 strain 변화를 동시에 측정할 수 있기 때문에 strain과 polarization의 상관관계를 정확히 조사할 수 있다는 장점이 있다. PMN계에서 인가되는 전계의 넓은 범위에서 전왜정수 Q값을 연속적으로 구할 수 있었다.

  • PDF

Detection of Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor (광대역 AE 센서에 의한 유중코로나의 초음파 특성)

  • Kim, In-Sik;Lee, Sang-U;Lee, Dong-In;Lee, Gwang-Sik;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.44-51
    • /
    • 2000
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz] to 1.5[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane gap and from the partial discharges of an epoxy void were analyzed to determine the proper ultrasonic sensor with optimum frequency range according to the patterns of corona discharges. We also examined the propagation characteristics of AE signals in oil and the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] ac high-voltage. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were about 130[kHz] by the fast fourier transform, but the main frequency spectra appeared to be 230[kHz] in the partial discharges of an epoxy void. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages.

  • PDF