• Title/Summary/Keyword: 60Hz

Search Result 1,303, Processing Time 0.027 seconds

Effects of Electro-acupuncture's Stimulated Frequency, Intensity, Duration at ST36 on the Small Intestine Motility in Rats (족삼리(足三里) 전침(電鍼)의 주파수(周波數), 강도(强度) 및 자극(刺戟) 시간(時間)이 소장(小腸) 수송능(輸送能)에 미치는 영향(影響))

  • Kim, Yong-Jeong;Park, Sang-Moo;Cha, Suk;Yun, Jeong-Ahn;Yu, Yun-Jo;Kang, Byung-Ki;Kim, Kang-San
    • Journal of Acupuncture Research
    • /
    • v.23 no.4
    • /
    • pp.175-185
    • /
    • 2006
  • Objectives : This study was designed to investigate effects of electro-acupuncture's stimulated frequency, intensity, duration at 5736 on tile Small Intestine Motility in Rats. Methods The motor activity of small intestine in rats was evaluated by intestinal transportation rate. Changes in tile motility of ileum in vivo was measured at 10 minutes after electro-acupuncture. Various kinds of stimulus-frequency were used in this experiment: 2 Hz, 50 Hz, 100 Hz, 2 Hz-4 trains, 8 Hz groups treated with EA of the condition in S mA, 1 ms pulse duration, 30 minutes stimulated duration. Three different stimulus-intensity were used: 1, 5, 10 mA groups treated with EA of the condition in 2 Hz, 1 ms pulse duration, 30 minutes stimulated duration. Six different stimulus-duration were used: 10, 20, 30, 40, 50, 60 minutes groups treated with EA of the condition in 2 Hz, 5 mA, 1 ms pulse duration. Results : 2 and 100 Hz groups significantly increased the small intestine motility, but 50 Hz group did not induce a significant change. Besides, small intestine motility was significantly increased only in 5 mA intensity (5 times twitch). futhermore, at least 20 minutes EA treatment was necessary to increase the small intestine motility. Conclusion : Those basic data form this study can be applied to established the effective treatment of EA for gastrointestinal diseases in the clinical field.

  • PDF

Manufacturing and Characteristics Analysis of a Testing Device for the Evaluation of a Distribution Board Management System (분전반 관리시스템 평가를 위한 시험 장치의 제작 및 특성 분석)

  • Ko, Wan Su;Lee, Byung Seol;Choi, Chung Seog
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.31-36
    • /
    • 2019
  • This study made a testing device to evaluate the distribution board management system. Power was supplied to the testing device using a loading-back method and the voltage applied to it was 440 V at the same turn ratio. When the human body electric shock current is 30 mA, the breaking time is set to be less than 240 ms while 30~45 mA current is flowing. The test result shows that in the case of the R-phase it was measured to be 5.19 Hz (193 ms). And the S-phase and T-phase were perfectly cut off at 5.39 Hz (186 ms) and 5.71 Hz (175 ms), respectively. When the human body electric shock current is 60mA, the breaking time is set to be less than 120 ms while 45~75 mA current is flowing. The test result shows that the R-phase, S-phase, and T-phase were accurately cut off at 8.39 Hz (11 ms), 8.87Hz (113 ms) and 9.69 Hz (103 ms), respectively. When the human body electric shock current is 90 mA, the breaking time is set to be less than 48 ms while 75 mA current is flowing. The test result shows that the R-phase, S-phase, and T-phase were accurately cut off at 19.8 Hz (50.4 ms), 16.9 Hz (59.2 ms), and 17.9 Hz (56.0 ms), respectively. That is, the developed testing device satisfied all the requirements of the distribution board evaluation criteria, and it becomes available for the performance evaluation of the distribution board management system.

Bandwidth Enhancement of a Broadband Ultrasonic Mosaic Transducer using 48 Tonpilz Transducer Elements with 12 Resonance Frequencies (12 주파수의 48 tonpilz 진동소자를 이용한 광대역 초음파 모자이크 변환기의 대역폭 확장)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.3
    • /
    • pp.302-312
    • /
    • 2014
  • This article describes the design and performance characteristics of a broadband ultrasonic mosaic transducer. We focus on the improved bandwidth in the high frequency band of a previously designed broadband ultrasonic transducer (Lee et al., 2014). The improvement in the pulse-echo bandwidth was achieved by employing twelve $2{\times}2$ element subarrays, operating at different resonance frequencies, and utilizing the mosaic array concept. We found that the -6 dB and -12 dB bandwidths of the newly developed broadband ultrasonic mosaic transducer, were up to 155% and 170% of the previously designed model, with a quality factor of 1.71 and 1.25, respectively. The averaged TVR (transmitting voltage response), SRT (receiving sensitivity), and FOM (figure of merit) values in a nearly flat transmitting response band, from 45 to 105 kHz providing a -12 dB bandwith of 60 kHz, were 163.3 dB (re $1{\mu}Pa/V$ at 1 m), -192.8 dB (re $1V/{\mu}Pa$), and -30.9 dB, respectively.

Correlation between the distribution of cultural noise source and MT data (인공잡음원의 공간분포와 MT자료의 상관관계)

  • Lee Choon-Ki;Lee Heuisoon;Kwon Byung-Doo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.209-214
    • /
    • 2005
  • In the present age, the quality of MT(magnetotellurics) data highly depends on the level of industrial interference in data. We analyzed the correlation between the spatial distributions of man-made EM noise source and the characteristics of MT data. The noise source analysis shows the correlation between the noise source density and the power spectral density of measured magnetic field in the frequency band of 60 Hz harmonics. In the MT 'dead band', the strong polarization observed on the magnetic field reveals that the severe artificial noises are caused by the adjacent metropolis.

  • PDF

CFD and Experimental Study of Gas Flow Inside the Steel Pipe Fitted in Reciprocating Hydrogen Compression System (왕복동식 압축시스템에 연결된 파이프 내부의 유동특성에 관한 CFD와 실험)

  • Rahman, Mohammad-Shiddiqur;Lee, Gyeong-Hwan;Lee, Kwang-Sung;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1513-1520
    • /
    • 2009
  • Renewability and pollutant free energy source makes hydrogen energy popular rapidly. Hydrogen gas pressure which is after passing through reciprocating compressor part has high pulsation wave form. A unit, snubber is used as compressor components to reduce the harmful pulsation waveform and to remove the impurities in the hydrogen gas. An experiment has been conducted to investigate the pulsation reduction performance of a steel pipe used in snubber system. The amplitude of pressure reduction were varied from $0.054{\sim}0.321\;kPa$ for 10 hz to 60 hz motor speed. Compressor operation by motor with 10 to 60 hz were resulted in reduction of pressure pulsation from 16.415% to 35.151%. Pressure losses were varied from $0.001%{\sim}0.759%$, and pressure drop per centimeter of the steel pipe were varied from $0.0160{\sim}16.03\;Pa$.

  • PDF

The Simulation of Transmission Line Fault-Induced Noise Signals. (선로고장시 발생되는 잡음의 시뮬레이션)

  • Shin, Myung-Chul;Kim, Mu-Woong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.454-456
    • /
    • 1987
  • A more specialized area of transient evaluations is transmission line fault-detecting and protection system. During the first cycle or two following a power system fault, a high-speed protective relay is expected to make a decision as to the severity or location of the fault, usually based on 60 Hz information, i.e. the phase and magnitude of 60 Hz voltage or current signals. It is precisely at this time however that the signal is badly corrupted by noise, in the form of a de offset or frequencies above 50 Hz. One of several possible sources of transients in protection measuring signals is in the primary system for which protection is required in its response to the impact of short circuit fault on-set. Other sources are in the primary voltage and current transducers from which protection signals are derived, and, often of particular importance, in the interface circuits between the transducer secondaries and the comparator and measuring elements of the protection system. However, the noise signals that will be described in this paper are due to the main power system only and do not include errors due to current or voltage transducers.

  • PDF

A Study on the Influence of Change of Electrical Stimulation Time on Body Regions Affects on Threshold of People Over Age 60 (60세이상 노인의 신체 부위별 전기자극시간에 따른 역치 변화에 대한 연구)

  • Lee, Jae-Kap;Choi, Jung-Hyun
    • Journal of Korean Physical Therapy Science
    • /
    • v.16 no.4
    • /
    • pp.29-37
    • /
    • 2009
  • Background: The purpose of this study was influence of change of electrical stimulation time on body regions affects on electrical current threshold. Methods: The present study is to examine the effect of silver spike point (SSP) electrical stimulation (1Hz), transcutaneous electrical nerve stimulation (TENS, 100Hz), and interferential current therapy (ICT, 50Hz) from the low back and scapulodorsal and knee joint regions on stimulation-induced current thresholds from the elderly (over sixty) people (male:72, female:91) in senior welfare center. Result: The low back region, but not scapulodorsal and knee joint region, significantly increased the TENS and ICT, but not SSP, electrical stimulation, significantly increased the time-dependent current thresholds in elderly patients. Conclusion: Therefore, these results, in part, suggest that the TENS and ICT were shown to be a more adaptable method of stimulation, and that needed of the development of senile specialized physical therapy and the utilization of senior leisure facilities such as senior welfare center the others.

  • PDF

Low Frequency Characteristic of Seoul Subway Noise (서울지하철의 저주파소음 특성)

  • Jung, Sung-Soo;Shin, Su-Hyun;Kim, Ho-Chul;Lee, Woo-Seop
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1193-1197
    • /
    • 2005
  • The low frequency noise below 200 Hz, including inaudible infra-sound, is known to affect human physiology ; circulation, respiration, nerve, endocrine, etc. Legislation has been introduced in several countries regarding evaluation guideline and measurement method of low frequency noise. In this work, low frequency characteristics of the Seoul subway transportation system was investigated in terms of the noise level and spectrum in the interior of running passenger car and the subway station. The interior sound pressure level of the passenger car was between 60 and 105 dB in the frequency range of $1{\sim}200\;Hz$ and varied with car speed. The marked sound pressure level peak at 8 Hz, infra-sound, observed for the most of Lines is shown to correspond to the resonance frequency of passenger car. The level of station platform noise was lower than the interior noise of running car because of the lower speed at arriving/departure. The results indicated that the interior noise level of running passenger car was inside the oppressive feeling region, proposed by Ochiai, in the frequency range of $20{\sim}80\;Hz$ which makes a little concern.

Frequency Dependence of High-frequency Bottom Reflection Loss Measurements (고주파 해저면 반사손실의 주파수 종속성 측정)

  • 박순식;윤관섭;최지웅;나정열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.8
    • /
    • pp.652-659
    • /
    • 2003
  • High-frequency(40∼120 kHz) reflection loss measurements on the water-sandy sediment with a flat interface were conducted in a water tank for various grazing angles. The water tank(5×5×5 m) was filled with a 0.5 m-thick-flat bottom of 0.5ø-mean-grain-size sand. Reflection losses, which were experimentally obtained as a function of grazing angle and frequency, were compared with the forward loss model, APL-UW model (Mourad & Jackson, 1989). For frequencies below 60 kHz, the observed losses well agree with the reflection loss model, however, in cases for frequencies above 70 kHz, the observed losses are greater by 2∼3 dB than the model results. The model calculation, which does not fully account for the vertical scale of roughness due to grain size, produce less bottom losses compared to the observations that correspond to large roughness based on the Rayleigh parameter in the wave scattering theory. In conclusion, for the same grain-size-sediment, as frequencies increase, the grainsize becomes the scale of roughness that could be very large for the frequencies above 70 kHz. Therefore, although the sea bottom was flat, we have to consider the frequency dependence of an effect of roughness within confidential interval of grain size distribution in reflection loss model.

Analysis of echolocation click signals of Indo-Pacific bottlenose dolphin (Tursiops aduncus) in Jeju Island (제주 남방큰돌고래 반향정위 클릭음 특성 분석)

  • Choi, Kang-Hoon;Yoon, Young Geul;Kim, Sunhyo;Kim, Hyeonsu;Choi, Jee Woong;Bae, Ho Seuk;Park, Kyeongju
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.1
    • /
    • pp.56-65
    • /
    • 2019
  • The Indo-Pacific bottlenose dolphins (Tursiops aduncus) are a toothed whale using echolocation clicks and have been studied continuously abroad. However, most studies on this whale's clicks were performed about captive animals and, in Korea, only the studies of the whistle sounds of this animal were done. In this paper, acoustic characteristics of clicks were analyzed about the free-ranging Indo-Pacific bottlenose dolphins living in the coast of the Jeju Island. Acoustic parameters such as signal duration, 1st and 2nd peak frequency, 3 dB and 10 dB bandwidth for acoustic characteristics were calculated and compared with those of Australian species. As a result, the signal durations had average of $38{\mu}s$ and most clicks were within range of $20{\mu}s-60{\mu}s$. The two types of bandwidths showed both narrowband and broadband characteristics, and bimodal signal characteristics were confirmed through the 1st peak frequencies(average of $96kHz{\pm}18kHz$) and the 2nd peak frequencies(average of $69kHz{\pm}19kHz$).