• Title/Summary/Keyword: 60 MeV

Search Result 210, Processing Time 0.034 seconds

A comprehensive evaluation of Mg-Ni based alloys radiation shielding features for nuclear protection applications

  • M.I. Sayyed;K.A. Mahmoud;Faras Q. Mohammed;Kawa M. Kaky
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1830-1835
    • /
    • 2024
  • The current study aims to study the impacts of the substitution of magnesium with nickel concentrations on physical and γ-ray shielding capacity of magnesium alloys. The density of the magnesium alloys under study is varied from 3.677 g/cm3 to 5.652 g/cm3, with raising the nickel content from 26.7 wt% to 54.8 wt% and reducing the magnesium concentration from 72.6 wt% to 44.2 wt%, respectively. Additionally, the examination of the γ-ray shielding capacity using the Monte Carlo simulation code shows that the substitution of magnesium by nickel content in the magnesium alloys was associated with an enhancement in the γ-ray shielding capacity, where the linear attenuation coefficient for the studied alloys was enhanced by 53.22 %, 52.45 %, and 52.52 % at γ-ray energies of 0.662 MeV, 1.252 MeV, and 1.408 MeV, respectively, with raising the nickel concentration from 26.7 wt% to 54.8 wt%. Simultaneously, the half-value thickness for magnesium alloys was reduced from 2.47 cm to 1.62 cm (at gamma ray energy of 0.662 MeV), from 3.39 cm to 2.22 cm (at gamma ray energy of 1.252 MeV), and from 3.60 cm to 2.36 cm (at gamma ray energy of 1.408 MeV), raising the nickel concentration from 26.7 wt % to 54.8 wt%, respectively. The study shows that the substitution of magnesium for nickel greatly enhanced the radiation shielding capacity of the magnesium alloys.

Introduction to Neutron Scattering for Magnetic Materials Research (자성소재 연구를 위한 중성자산란 입문)

  • Jeong, Jae-Hong;Lee, Sang-Hyun;Park, Je-Geun
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.3
    • /
    • pp.103-108
    • /
    • 2012
  • Having a de Broglie wavelength of a few ${\AA}$ with its corresponding energies in the range of a few to a few hundreds meV, neutrons are ideally suited for the studies of structure and dynamics in condensed matter research. Neutron scattering has been developed over the past 60 years or so and become a very mature and established experimental technique in the very broad range of material sciences. In this short introductory article, we have explained its working principles and provided few selected examples of application.

Development of the Graphite-Moderated Neutron Calibration Fields Using 241Am-Be Sources in JAEA-FRS

  • Nishino, Sho;Tanimura, Yoshihiko;Ebata, Yoshiaki;Yoshizawa, Michio
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.211-215
    • /
    • 2016
  • Background: The moderated neutron calibration fields using $^{241}Am$-Be sources and a graphite moderator have been constructed at the Facility of Radiation Standard (FRS) in the Japan Atomic Energy Agency (JAEA). Materials and Methods: The neutron spectra of the fields were evaluated by the Monte-Carlo calculations and measurements using the Bonner Multi-sphere Spectrometer. Results and Discussion: The fields have continuous neutron spectra from several MeV to thermal neutron energy, with fluence-averaged energies of 0.84 MeV and 0.60 MeV. Reference values of fluence rates and ambient/personal dose equivalent rates were determined from neutron spectra by measurements. Conclusion: Currently, the fields are available for calibration or performance test of neutron measuring instruments.

X-ray Rocking Curve Analysis of Post-Annealed 3 MeV P+ Implanted Silicon (3MeV P+ 이온주입된 실리콘의 열처리에 따른 X-ray Rocking Curve 분석)

  • 조남훈;장기완;김창수;이정용;노재상
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.1
    • /
    • pp.109-117
    • /
    • 1995
  • 고에너지 이온주입시 격자결함의 생성 및 열처리 거동이 double crystal X-ray와 단면 TEM을 사용하여 연구되었다. 3MeV P+ 이온주입한 실리콘의 DCXRD 분석 결과조사량 증가에 따라 모재 내의 변형량은 증가하였다. HRTEM 분석 결과 고에너지 이온주입시 결함은 표면 부근에 희박하고 Rp 부근에 집중되어 있었다. 또한 이온주입 상태의 결함층은 dark band의 형태로 존재하였으며 열처리시 이차결함은 이곳으로부터 생성됨이 관찰되었다. 3MeV P+,$1X1015extrm{cm}^2$의 조건으로 이온주입된 실리콘 시편의 열처리에 따른 X-ray rocking curve 분석을 통하여 열처리 온도가 $550^{\circ}C$에서 $700^{\circ}C$로 증가함에 따라 모재 내부의 최대 변형량이 7X10-4에서 2.9X10-4으로 감소함이 관찰되었다. 특히 $550^{\circ}C$ 열처리한 시편의 경우 표면으로부터$-1.5mu$m 영역에 작은 변형층이 넓게 잔존하였으며 열처리온도를 $700^{\circ}C$로 증가한 경우 제거되었다. 이온주입시 생성된 일차결함들은 $700^{\circ}C$ 열처리시 $60^{\circ}$ 전위와 <112> 막대 모양 결함, $1000^{\circ}C$ 열처리시 <110>방향의 전위루프로 열처리 조건에 따라 여러 가지 모양의 이차결함으로 변화하였다. 고에너지 이온주입에 의해 발생한 이차결함은 고온에서도 안정하여 고온 열처리에 의한 제거가 용이하지 않았다.

  • PDF

Thermally Stimulated Exoelectron Emission from LiF(Mg,Cu,Na,Si) Phosphor (LiF(Mg,Cu,Na,Si)형광체의 열자극엑소전자방출)

  • Doh, Sih-Hong;Jeong, Jung-Hyun;Aoki, M.;Nishikawa, T.;Tamagawa, Y.;Isobe, M.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.11-15
    • /
    • 1994
  • The TSEE characteristics of LiF(Mg,Cu,Na,Si)phosphor for gamma and beta rays are described. The TSEE glow curve of this phosphor showed 5 peaks in the range from $20^{\circ}C$ to $400^{\circ}C$ and its main peak appeared at $240^{\circ}C$. The sensitivity of the phospor for $^{60}Co$ gamma rays was about 450counts/mR. TSEE energy dependence for various beta radiation was nearly constant (${\pm}10%$) in the mean beta particle energy range from 0.02MeV to 0.8MeV. The efficiency of TSEE of the phosphor for beta radiation was $(2{\sim}15){\times}10^{-3}$.

  • PDF

A Study on the dosimetry in boundary of shielding block in high energy irradiation (고에너지 방사선치료에서 차폐물 경계부위의 선량분포에 관한 고찰)

  • Kim, Myung-Se;Kim, Sung-Kyu;Shin, Sei-One
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.115-120
    • /
    • 1990
  • Scatter-air ratios are used for the purpose of calculating scattered dose in the medium. The computation of the primary and the scattered dose separately is particularly useful in the dosimetry of irregular fields with shielding block in radiation field, dose distribution of scattered radiation using 18MeV Linear accelerator and Co-50 teletherapy measured. The effect of scattered radiation dose by protecting block was been ignored in radiation therapy, 2-3% of scattered radiation may be 90-200 cGy which could be influence vitial complications such as cataract, oligospermia or sterility. So that exect calculation of such scattered radiation especially for large field $\bar{c}$ small protection of vitial organ is very important. The purpose of this article is to calculate scattered radiation by protecting block exactly for irregular field $\bar{c}$ Linac or Co-60 irradiation and to applicate these data in clinical radiation field. Authors could obtain following results. 1. The lesser angle between shielding block showed more scattered radiation. 2. With decreasing distance between shielding blocks, the dependent of scattered radiation were increased. 3. Output of 18MeV Linear accelerator and Co-60 was related linear proportion on field size, but independent according to the size of shielding block in 18MeV Linear accelerator.

  • PDF

A Study on Efficiency Error in Distance Inverse Square Law using Cylinder NaI(Tl) Scintillation Detector (원통형 NaI(Tl) 신틸레이션 검출기를 이용한 거리의 역자승 법칙에서 효율 오류에 대한 연구)

  • Lee, Samyol;Yoon, Jungran;Ro, TaeIk
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.5
    • /
    • pp.333-338
    • /
    • 2013
  • Generally, it's known fact that intensity of radioactivity satisfies inverse-square law. However, the law was dissatisfied with practical experiment because of limited shape of scintillation detector. Especially, in the case of near distance between the surface of detector and the radioactive source, the difference grows larger. In the present study, reason of this difference was confirmed by experiment with $2^{{\prime}{\prime}}{\times}2^{{\prime}{\prime}}{\phi}$ NaI(Tl) scintillation detector and $^{60}Co$(1.174 MeV, 1.333 MeV)and $^{137}Cs$(0.662 MeV) gamma ray sources. From the experiment, the correction coefficient was obtained with gamma ray detection efficiency and geometrical volume. In the result of the present study, the efficiency difference of the detector was corrected with the coefficient. In the present result, we obtained that the inverse-square law experiment have to consider the efficiency and geometrical value of the detector.

A Study on Effective Source-Skin Distance using Phantom in Electron Beam Therapy

  • Kim, Min-Tae;Lee, Hae-Kag;Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.15-19
    • /
    • 2014
  • In this study, for 6-20 MeV electron beam energy occurring in a linear accelerator, the authors attempted to investigate the relation between the effective source-skin distance and the relation between the radiation field and the effective source-skin distance. The equipment used included a 6-20 MeV electron beam from a linear accelerator, and the distance was measured by a ionization chamber targeting the solid phantom. The measurement method for the effective source-skin distance according to the size of the radiation field changes the source-skin distance (100, 105, 110, 115 cm) for the electron beam energy (6, 9, 12, 16, 20 MeV). The effective source-skin distance was measured using the method proposed by Faiz Khan, measuring the dose according to each radiation field ($6{\times}6$, $10{\times}10$, $15{\times}150$, $20{\times}20cm^2$) at the maximum dose depth (1.3, 2.05, 2.7, 2.45, 1.8 cm, respectively) of each energy. In addition, the effective source-skin distance when cut-out blocks ($6{\times}6$, $10{\times}10$, $15{\times}15cm^2$) were used and the effective source-skin distance when they were not used, was measured and compared. The research results showed that the effective source-skin distance was increased according to the increase of the radiation field at the same amount of energy. In addition, the minimum distance was 60.4 cm when the 6 MeV electron beams were used with $6{\times}6$ cut-out blocks and the maximum distance was 87.2 cm when the 6 MeV electron beams were used with $20{\times}20$ cut-out blocks; thus, the largest difference between both of these was 26.8 cm. When comparing the before and after the using the $6{\times}6$ cut-out block, the difference between both was 8.2 cm in 6 MeV electron beam energy and was 2.1 cm in 20 MeV. Thus, the results showed that the difference was reduced according to an increase in the energy. In addition, in the comparative experiments performed by changing the size of the cut-out block at 6 MeV, the results showed that the source-skin distance was 8.2 cm when the size of the cut-out block was $6{\times}6$, 2.5 cm when the size of the cut-out block was $10{\times}10$, and 21.4 cm when the size of the cut-out block $15{\times}15$. In conclusion, it is recommended that the actual measurement is used for each energy and radiation field in the clinical dose measurement and for the measurement of the effective source-skin distance using cut-out blocks.

A Study on Non-proportionality of Phoswich Detector Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 Phoswich 계측기의 비선형성 연구)

  • Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Soon-Young;Kim, Yong-Kyun;Lee, Woo-Gyo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.263-268
    • /
    • 2004
  • Using the Monte Carlo simulation, a study on the lion-proportionality of the prototype phoswich detector with $2'{\times}2'$ CSI(Tl) and plastic scintillator, which was made by KAERI, has been carried. The defector response functions (DRFs) calculated by simulations were compared with the experimental measurement on the $^{137}Cs\;and\;^{60}Co$. To precisely simulate the DRF for the phoswich, the CSI(Tl) non-proportionality was calculated using the electron response and the simplified electron cascade sequence for treating the photoelectric absorption event. The resulting DRFs of $^{137}Cs\;and\;^{60}Co$ sources obtained by simulations were compared with experiments for verification. For $^{137}Cs$, gamma-ray responses simulated by MCNP5 are generally good agreement with the measured ones. But the DRF of $^{60}Co$ does not match well with the results of experiment in the energy region below second peak due to the coincidence effect of two gamma-rays (1.17 MeV and 1.33 MeV). Through the analysis of the non-proportionality of CsI(Tl) in the prototype phoswich, the improved DRFs considering non-proportionality were produced and the simulation results were verified using the experimental measurements. However, to more precisely reproduce the DRF for the phoswich, further studies in relation to the electron channeling effect and the Doppler broadening effect of a scintillator are still needed as well as considering that effect of the transfer contribution.

Size-homogeneous gold nanoparticle decorated on graphene via MeV electron beam irradiation

  • Kim, Yoo-Seok;Song, Woo-Seok;Jeon, Cheol-Ho;Kim, Sung-Hwan;Park, Chong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.487-487
    • /
    • 2011
  • Recently graphene has emerged as a fascinating 2D system in condensed-matter physics as well as a new material for the development of nanotechnology. The unusual electronic band structure of graphene allows it to exhibit a strong ambipolar electric field effect with high mobility. These properties lead to the possibility of its application in high-performance transparent conducting films (TCFs). Compared to indium tin oxide (ITO) electrodes, which have a typical sheet resistance of ${\sim}60{\Omega}$/sq and ~85 % transmittance in the visible range (400?900 nm), the CVD-grown graphene electrodes have a higher/flatter transmittance in the visible to IR region and are more robust under bending. Nevertheless, the lowest sheet resistance of the currently available CVD graphene electrodes is higher than that of ITO. Here, we report an ingenious strategy, irradiation of MeV electron beam (e-beam) at room temperature under ambient condition, for obtaining size-homogeneous gold nanoparticle decorated on graphene. The nano-particlization promoted by MeV e-beam irradiation was investigated by transmission electron microscopy, electron energy loss spectroscopy elemental mapping, and energy dispersive X-ray spectroscopy. These results clearly revealed that gold nanoparticle with 10 ~ 15 nm in mean size were decorated along the surface of the graphene after 1.5 MeV-e-beam irradiation. A chemical transformation and charge transfer for the metal gold nanoparticle were systematically explored by X-ray photoelectron spectroscopy and Raman spectroscopy. This approach advances the numerous applications of graphene films as transparent conducting electrodes.

  • PDF