• Title/Summary/Keyword: 60 MeV

Search Result 210, Processing Time 0.031 seconds

Duckweed as a Protein Source for Fine-Wool Merino Sheep: Its Edibility and Effects on Wool Yield and Characteristics

  • Damry, J.V. Nolan;Bell, R.E.;Thomson, E.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.4
    • /
    • pp.507-514
    • /
    • 2001
  • Two experiments were carried out to investigate whether duckweed is useful as a dietary protein source for fine-wool Merino sheep and to evaluate its effects on wool yield and characteristics. In Experiment 1, the sheep were given one of three maintenance diets consisting of oaten chaff (520-700 g/d) supplemented with 16-32 g crude protein/d in the form of fresh (1 kg/d) or sun-dried (50-100 g/d) duckweed. Each ration was estimated to provide 5.4 MJ (1.3 Mcal)/d of metabolisable energy (ME). The sheep readily ingested the fresh or dried duckweed. None of the wool measures (yield, rate of fibre elongation, fibre diameter) differed (p>0.05) between dietary treatments. In Experiment 2, oaten-chaff-based diets (800 g/d) supplying 6.5-7.2 MJ (1.6-1.7 Mcal)/d of ME were supplemented with iso-nitrogenous amounts (4-5 g N) either of urea (8 g), cottonseed meal (60 g) or dried duckweed (100 g). In this experiment, the rate of wool fibre elongation, thought to be related to intestinal amino acid absorption, was lower (p<0.05) for sheep given the oaten chaff/urea diet than for those given either oaten chaff/cottonseed meal or oaten chaff/duckweed for which the rates did not differ (p>0.05). Fibre diameter, which ranged from 16.0-16.7 mm, did not differ (p>0.05) between diets, but tended to be lower on the oaten chaff/urea diet so that volume of wool produced was also significantly lower (p<0.05) on this diet than on the diets containing duckweed or cottonseed meal. Rumen ammonia concentrations at 4.5 and 7.5 h after feeding were higher (p<0.05) for sheep given the oaten chaff/urea diet than for those given the other two diets. A comparison of the rumen ammonia concentrations, wool growth rate and predicted flows of amino acids from the rumen of sheep supplemented with duckweed rather than cottonseed meal suggested that duckweed is a valuable source of 'escape protein' for ruminants.

Gamma radiation attenuation properties of tellurite glasses: A comparative study

  • Al-Hadeethi, Y.;Sayyed, M.I.;Tijani, S.A.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.2005-2012
    • /
    • 2019
  • This work investigated the radiation attenuation characteristics of three series of tellurite glass systems with the following compositions: 30PbO-10ZnO-xTeO2-(60-x)B2O3 where x = 10, 30, 40, 50 and 60 mol%, xBaO-xB2O3-(100-2x)TeO2 with x = 15-40 mol% and 50ZnO-(50-x)P2O5-xTeO2, where x = 0, 10, .40 mol%. The results revealed that the attenuation parameters in all the samples decrease with increase in the energy, which implied that all the samples have better interaction with gamma photons at low energies and thus higher photon attenuating efficiency. From the three systems, the samples coded as PbZnBTe60, BaBTe70 and ZnPTe40 have the lowest half value layer values and accordingly have superior photon attenuation efficacy. The maximum effective atomic number values were found for energy less than 0.1 MeV particularly near the K-edges absorption of the heavy atomic number elements such as Te, Ba and Pb. At the lowest energy, the Zeff values are found in the range of 62.33-66.25, 49.43-50.81 and 24.99-35.83 for series 1-3 respectively. Also, we found that the density of the glass remarkably affects the photon attenuation ability of the selected glasses. The mean free path results showed that the PbO-ZnO-TeO2-B2O3 glass system has better radiation shielding efficiency than the glass samples in series 2 and 3.

An Extraction of Barley Protein and a Comparison of the Protein Composition of Some Barleys -I. Extraction of Barley Protein- (보리단백질의 추출 및 품종간 조성비교 -I. 보리단백질의 추출-)

  • Kim, Jung-Sang;Kim, Ze-Uook
    • Applied Biological Chemistry
    • /
    • v.29 no.1
    • /
    • pp.51-56
    • /
    • 1986
  • Using milled barley of four varieties Olbori, Youngsan-bori, Sacheon 6, and Suwon 228, the barley proteins were fractionated by the Osborne method and the modified Osborne method. Two fractionation methods were compared. There was a steady increase in the amount of nitrogen extracted as NaCl concentration increased, reaching a maximum at 0.5M NaCl and the extraction of nitrogen by 0.5M NaCl reached a maximum at $22^{\circ}C$. Alcohol-soluble fraction was least extracted by 70% (v/v) ethanol at $4^{\circ}C$ and most by sequential extraction with 50% (v/v) propan-1-ol alone followed by 50% (v/v) propan-1-ol plus 3% (v/v) 2-mercaptoethanol. Nitrogen was least extracted between pH 4 and 6 and most extracted at higher pH than 10. The modified Osborne fractionation of the protein complex in the four barleys showed that the salt-soluble nitrogen accounted for 21,4% to 24.1%, hordein-I varied from 30.4% to 43.4%, hordein-II varied widely from 9.3% to 19.5% and borate buffer-soluble glutelin content ranged from 17.1% to 23.7%.

  • PDF

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.

Effects of Nucleation Layer's Surface Roughness on the Quality of InP Epitaxial Layer Grown on GaAs Substrates (Nucleation Layer의 표면 거칠기가 GaAs 기판 위에 성장된 InP 에피층의 품질에 미치는 영향)

  • Yoo, Choong-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.8
    • /
    • pp.575-579
    • /
    • 2012
  • Heteroepitaxial InP films have been grown on GaAs substrates to study the effects of the nucleation layer's surface roughness on the epitaxial layer's quality. For this, InP nucleation layers were grown at $400^{\circ}C$ with various ethyldimethylindium (EDMIn) flow rates and durations of growth, annealed at $6200^{\circ}C$ for 10 minutes and then InP epitaxial layers were grown at $550^{\circ}C$. It has been found that the nucleation layer's surface roughness is a critical factor on the epitaxial layer's quality. When a nucleation layer is grown with an EDMIn flow rate of 2.3 ${\mu}mole/min$ for 12 minutes, the surface roughness of the nucleation layer is minimum and the successively grown epitaxial layer's qualities are comparable to those of the homoepitaxial InP layers reported. The minimum full width at half maximum of InP (200) x-ray diffraction peak and that of near-band-edge peak from a 4.4 K photoluminescence are 60 arcmin and 6.33 meV, respectively.

Estimation of Dry Deposition Velocity for Elements in Atmospheric Aerosols by Low-Pressure Impactor (저압 임팩터를 이용한 대기 에어로졸 중 원소 성분의 건성침착속도 추정에 관한 연구)

  • 박정호;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.5
    • /
    • pp.445-451
    • /
    • 2000
  • To estimate dry deposition flux of 12 elements in aerosols, aerosol particles were sampled by a low-pressure impactor(LPI) and a dust jar. The concentrations of 12 elements in aerosol particle and dry deposition were analyzed by a PIXE analysis using as a 2.0 MeV-proton beam. The mean dry deposition velocities of 12 elements were estimated by ranges of 0.74∼2.62 cm/sec. The results showed that the highest value was 3.26 cm/sec for Ca and the lowest value 0.74 cm/sec for Fe. The dry deposition flux for elements was calculated as a function of particle size by 1-step method and 12-step method. In this work, dry deposition velocities were computed with the two existing models; the coarse-particle fraction(4∼30 mm diameter) using the dry deposition velocity model of the Noll and Fang(1998) and the fine-particle fraction (0.05∼4mm diameter) using the Shemel and Hodgson(1980) model. The ratios of the mean calculated/measured fluxes were 3.59 for 1-step method and 0.60 for 12-step method respectively.

  • PDF

The Electrical and Microstructural Properties of ZnO:N Thin Films Grown in The Mixture of $N_2$ and $O_2$ by RF Magnetron Sputtering

  • Jin, Hu-Jie;Lee, Eun-Cheal;So, Soon-Jin;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.144-145
    • /
    • 2006
  • ZnO is a promising material to make high efficiency violet or blue light emitting diodes (LEDs) for its large binding energy (60meV) and big bandgap. But the high quality p-type conduction of ZnO is a dilemma to achieve LEDs with it. In present study, we presented a reliable method to prepare ZnO thin films on (100)silicon substrates by RF magnetron sputtering in the mixture ambient of $N_2$ and $O_2$, accompanying with low pressure annealing in the sputtering chamber in $O_2$ at $600^{\circ}C$ and $800^{\circ}C$ respectively. X-ray diffraction and Hail effect with Van der Paul method were performed to test ZnO films. Seeback effect was also carried out to identify carrier types in ZnO films and showed the N-doped ZnO film annealed at $800^{\circ}C$ had achieved p-type conduction.

  • PDF

An Epithermal Neutron Beam Design for BNCT Using $^2H(d,n)^3He$ Reaction

  • Han, Chi-Young;Kim, Jong-Kyung;Chung, Kyu-Sun
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.512-521
    • /
    • 1999
  • A feasibility study was performed to design an epithermal neutron beam for BNCT using the neutron of 2.45 MeV on the average produced from $^2H(d,n)^3$He reaction induced by plasma focus in the z-pinch instead of the conventional accelerator-based $^3H(d, n)^4$He neutron generator. Flux and spectrum were analyzed to use these neutrons as the neutron source for BNCT. Neutronic characteristics of several candidate materials in this neutron source were investigated Using MCNP Code, and $^7LiF$ ; 40%Al + 60%$AIF_3$, and Pb Were determined as moderator, filter, and reflector in an epithermal neutron beam design for BNCT, respectively. The skin-skull-brain ellipsoidal phantom, which consists of homogeneous regions of skin-, bone-, or brain-equivalent material, was used in order to assess the dosimetric effect in brain. An epithermal neutron beam design for BNCT was proposed by the repeated work with MCNP runs, and the dosimetric properties (AD, AR, ADDR, and Dose Components) calculated within the phantom showed that the neutron beam designed in this work is effective in tumor therapy. If the neutron source flux is high enough using the z-pinch plasma, BNCT using the neutron source produced from $^2H(d,n)^3$He reaction will be very feasible.

  • PDF

Current status of research on radionuclides used in nuclear mediccine (중성자선 실험 및 발암연구의 현황과 미래)

  • Kim, Hui-Seon
    • Radioisotope journal
    • /
    • v.21 no.3
    • /
    • pp.46-60
    • /
    • 2006
  • In recent years the progress of nuclear medicine advanced dramatically in imaging and targeted radionuclide therapy is able to open op exciting perspectives as standard diagnostic and therapeutic modalities, complementing conventional modalities. Positron emission tomography/computed tomography (PET/CT) technology with FDG has been developed clinically in less than 10 years as a routine standard in oncological imaging, including a number of other fluorinated radiopharmaceuticals being evaluated for their ability to complement FDG. However, the limitation of FDG-PET such as non-specific uptake and its short half-life is not compatible with the time necessary for optimal tumour targeting. Therefore, a development of innovative positron-emitting radionuclides with half-lives longer than 10 h is needed. For therapeutic applications, the injection of higher activities is required to reach efficient adsorbed doses in radioresistant solid tumours, while limiting the irradiation of vital organs. In this application, the longer half-life of radiolsotopes are more fit well for radionuclide therapy. To achieve this, researches have to be carried in a largor spectrum of radionuclides for diagnosis and therapy. In the context of rapidly growing nuclear medicine and strong demanding innovative radionuclides, a high-energy (100 MeV), high-intensity (-mA) accelerator with proton (PEFF at KAFRI). will be operating in 2011. The priorities of PEFP will include supporting the nuclear medicine research community by providing those radionuclides with current limited availability by means of a high-energy, high-intensity accelerator.

  • PDF