• Title/Summary/Keyword: 60 MeV

Search Result 210, Processing Time 0.03 seconds

A Study on the Fabrication of CsI(T1) Radiation Sensor and its Spectroscopic Characteristics (CsI(T1) 방사선센서의 제작 및 분광특성 연구)

  • 권수일;신동호
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2002
  • CsI(T1) single crystal was grown in a Bridgman growing apparatus, which has the diameter of 11 mm and the mole ratio of 0.001 mol%. Radiation sensors were made with CsITl)crystal and two photodiodes, and measured spectroscopic characteristics and linearity for gamma-ray and X-ray. The energy resolution of CsI(T1) radiation sensor has been measured with $^{22}$ Na, $^{137}$ Cs and $^{60}$ Co gamma standard sources. Also output linearity of CsITl) sensor was measured for diagnostic radiation region. The energy resolutions of CsI(T1) radiation sensor for 0.511MeV gamma-ray from Na-22 source, 0.662MeV from Cs-137 source, and 1.17MeV and 1.332MeV from Co-60 source were 13.2%, 8.3%, 6.7%, and 5.1% respectively. Also the output linearity up to 80mAs current for 60kVp, 80kvp, 100kVp, 120kVp tube voltages has been studied.

  • PDF

The Experimental Study of the Effective Point of Measurement for Cylindrical Ion Chamber -For Medical Electron Beams- (원통형 전리함의 유효 측정점에 관한 실험적 연구 -의료용 전자선을 중심으로-)

  • 이병용;최은경;장혜숙;홍석민;이명자;전하정
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.155-160
    • /
    • 1991
  • We have studied the effective point of measurement for cylindrical ion chamber in water phantom for medical electron beams. Markus parallel plate chamber water phantom are used for the measurement of depth dose to determine the depth of the effective point of measurement for various energies(for electron 6MeV, 9MeV, 12MeV, 16MeV, and 20MeV; Co-60; for photon 6MV, 15MV). Cylindrical ion chambes(PTW233643 with r=2.75mm, PR-05P with r=2mm, and PM30 wiht r=15mm are used for the measurement of depth dose by same mtethod and the values of d$\_$50/ and R$\_$p/ obtained by three cylindrical chambers were compared with those of a flat chamber. From this we could evaluate the effective measuring points of cylindrical ion chamber. The effective point of measurement was estimated as 0.4~0.6r shifted toward surface from the center of the chamber for electron beam, 0.3~0.7r for $\^$60/Co X-ray.

  • PDF

A Study on the Treatment of Combine Electron Beam in the Treatment of Breast Cancer Tumor Bed (유방암 Tumor bed 치료 시 혼합 전자선 치료 방법에 대한 고찰)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.51-56
    • /
    • 2019
  • Purpose: The usefulness of using single-electron radiation for secondary radiotherapy of breast cancer patients after surgery is assessed and the use of a combine of different energy. Methods and materials : In this study, 40 patients (group A) using energy 6 MeV and 9 MeV, and 19 patients (group B) using a combine of 9 MeV and 12 MeV were studied among 59 patients who performed secondary care using combine electronic radiation. Each patient in each group, 6 MeV, 9 MeV, Combine(6 MeV / 9 MeV) and 9 MeV, 12 MeV, Combine (9 MeV / 12 MeV) were developed in different ways, and the maximum doses delivered to the original hospital, D95, D5, and $V_3$, $V_5$, $V_{10}$ were compared. Result: The D95 mean value of Group A treatment plan was $785.33{\pm}225.37cGy$, $1121.79{\pm}87.02cGy$ at 9 MeV, and $1010.98{\pm}111.17cGy$ at 6 MeV / 9 MeV, and the mean value at 6 MeV / 9 MeV was most appropriate for the dose. The mean values of the low dose area $V_3$ and $V_5$ in the lung of the breast direction being treated were $3.24{\pm}3.49%$ and $0.72{\pm}1.55%$ at 6 MeV, the highest 9 MeV at $7.25{\pm}4.59%$, $3.07{\pm}2.64%$, the lowest at 6 MeV. Maximum and average lung dose was $727.78{\pm}137.27cGy$ at 6 MeV / 9 MeV, $49.16{\pm}24.44cGy$, highest 9 MeV at $998.97{\pm}114.35cGy$, $85.33{\pm}41.18cGy$, and lowest 6 MeV at $387.78{\pm}208.88cGy$, $9.27{\pm}6.60cGy$. The value of $V_{10}$ was all close to zero. Group B appeared in the pattern of Group A. Conclusion: Relative differences in low-dose areas of the lungs $V_3$ and $V_5$ were seen and were most effective in the dose transfer of tumor bed in the application of combined energy. It is thought that the method of using electronic energy in further radiation treatments for breast cancer is a more effective way to use the energy effect of limiting energy resources, and that if you think about it again, it could be a little more beneficial radiation treatment for patients.

Calculation of Proton-Induced Reactions on Ti, Fe, Cu and Mo up to 60 MeV for TLA Application

  • Kim, Doohwan;Lee, Young-Ouk;Jonghwa Chang
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.595-607
    • /
    • 1999
  • The reaction cross-sections of $^{nat}$Ti(p,X)$^{48}$ V, $^{nat}$Fe(p,X)$^{56}$ Co, $^{nat}$Cu(p,X)$^{65}$ Zn and $^{nat}$Mo(p,X)$^{96}$ Tc for TLA application are calculated in the frame of the ECIS-GNASH code system up to 60 MeV. The calculated results are compared with the experimental data taken from the EXFOR at the NEA Data Bank. A preliminary calculation with the global optical parameters of Varner et al. shows considerable differences from the experimental data at low energy range. The global optical parameters for the imaginary volume potential and the diffuseness of the imaginary potential are adjusted to achieve a better description of the experimental data in the vicinities of peak position below 16 MeV. 16 MeV.

  • PDF

Optical properties of Zn-doped InGaN grown by MOCVD (MOCVD로 성장한 Zn-doped InGaN의 광특성 연구)

  • 이창명;이주인;임재영;신은주;김선운;서준호;박근섭;이동한
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.67-71
    • /
    • 2001
  • Optical investigation on Zn-doped InGaN grown by MOCVD was performed by using the photoluminescence. Two different spectra related to Zn-acceptor-like centers occurred at room temperature, with broad emissions peaking at 2.81, and 2.60 eV, Specially, emissions interacted with phonon were observed at 2.81 eV where phonon energy was 92.5 meV From temperature dependent blue-band emissions of InGaN, we observe that the intensity in high energy region was quickly decreased more than that in low energy region with increased temperature, and the peak position at 2.81 eV was blue shift of about 18 meV, The blue-band emmissions would be originated from the transition related to the localized Zn complex centers.

  • PDF

Spectroscopic Properties of a Silicon Photomultiplier-based Ce:GAGG Scintillation Detector and Its Applicability for γ-ray Spectroscopy (감마선 분광분석을 위한 실리콘 광 증배소자 기반 Ce:GAGG 섬광검출기의 분광특성 연구)

  • Park, Hye Min;Kim, Jeong Ho;Kim, Dong Seong;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.73-78
    • /
    • 2015
  • In this study, a scintillation detector was fabricated using a silicon photomultiplier (SiPM) and a Ce:GAGG scintillator single crystal, and its spectroscopic properties were compared with those of commercially available LYSO and CsI:Tl scintillators using ${\gamma}$-ray spectroscopy. The energy resolutions of the self-produced scintillation detector composed of the scintillator single crystal (volume: $3{\times}3{\times}20mm^3$) and SiPM (Photosensitive area: $3{\times}3mm^2$) for standard ${\gamma}$-ray sources, such as $^{133}Ba$, $^{22}Na$, $^{137}Cs$ and $^{60}Co$ were measured and compared. As a result, the energy resolutions of the proposed Ce:GAGG scintillation detector for g-rays, as measured using its spectroscopic properties, were found to be 13.5% for $^{133}Ba$ 0.356 MeV, 6.9% for $^{22}Na$ 0.511 MeV, 5.8% for $^{137}Cs$ 0.662 MeV and 2.3% for $^{60}Co$ 1.33 MeV.

Characteristics and Applications of Soild State Nuclear Track Detectors -The Detection and Dosimetry of N-Ions by CR-39- (고체비적검출기(固體飛跡檢出器)의 특성(特性)과 그 응용(應用) -CR-39에 의한 질소(窒素)이온 검출(檢出)과 선양측정(線量測定)-)

  • Kang, Yung-Ho;Kim, Do-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.55-60
    • /
    • 1984
  • The optimum etching condition of allyl diglycol carbonate (CR-39) for detecting the 60 MeV N-ions was determined as $70^{\circ}C$, 20% NaOH for 130min, by considering the variations of track density and diameter. Under these conditions, the maximum detectable track density was $1.7{\times}10^7tr/cm^2$. Track densities were linearly increased with increase of the total charge of the incident 60 MeV N-ions. By considering the scattring of N-ions as the Rutherford elastic scattering of point source, the measured relative probability was well consistent with the calculated value. The detection efficiency of CR-39 was in the range of 54-41% for 60 MeV N-ions of 12 nC-100 nC.

  • PDF

평행평판형이온함을 이용한 전자선 흡수선량결정에 대한 연구

  • Ra, Jeong-Eun;Seo, Tae-Seok;Sin, Dong-O
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.149-152
    • /
    • 2004
  • 물 흡수선량 표준에 토대를 두고 있는 프로토콜에서는 저에너지 전자선의 경우 평행평판형이온함의 사용과 기준 선질 $^{60}$CO 감마선의 물 흡수선량 교정정수를 받은 원통형이온함을 사용하여 고에너지 전자선에서 평행평판형이온함을 교차교정하도록 권고하고 있다. 따라서 본 연구에서는 국제원자력기구의 프로토콜(IAEA TRS-398)에서 권고하고 있는 절차에 따라 저에너지 전자선에 대한 원통형이온함의 선질보정정수를 계산하고, 원통형이온함과 평행평판형이온함의 교정방법에 따른 흡수선량을 상호 비교하였다. 그 결과 전자선에너지 10 MeV 이상에서는 두 이온함간의 선량이 잘 일치하였으나 전자선에너지 6, 9 MeV에서 최대 3.3%까지 선량 차이를 보여 저에너지 전자선에서는 반드시 평형판판형이온함의 사용하여 선량측정 할 것을 권고한다. 교정방법 차이에 의한 평행평판형이온함의 선량은 서로 잘 일치하는 것으로 나타나 표준기관에서 직접 교정받은 $^{60}$Co 감마선의 물 흡수선량교정정수를 사용하여 전자선 물 흡수선량을 결정해도 큰 영향은 없을 듯하다. 또한 평행평판형이온함을 교차 교정하기 위한 전자선 에너지에 따른 흡수선량을 상호 비교한 결과 20MeV이외 12, 16 MeV의 전자선 에너지에서도 잘 일치하여 교차교정을 위한 전자선의 기준 선질에 대한 연구가 더 진행되어야 한다고 사료된다.

  • PDF

The Characteristics of Two-dimensional Radiation Monitoring System (2차원 방사선준위 분포측정 시스템의 제작 및 특성 조사)

  • Kim, S.H.;Han, S.H.;Kim, K.R.;Kang, H.D.;Choi, Y.S.;Lee, Y.B.;Lee, J.M.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.290-297
    • /
    • 1997
  • In this study, the radiation monitoring system using CsI(TI) scintillation counter is developed for the measurement of radiation distribution in the field of high dose level. When the inner diameter of collimator is 8 mm, we have realized the optimum detecting efficiency and spatial resolution. At that time, the position resolution was 10 cm at 1 m from the system. And experimental results indicated that the energy resolution of the system were 10 % for 662 keV of Cs-137, 7.6 % for 1.17 MeV of Co-60, and 5.8 % for 1.33 MeV of Co-60. Also, we have shown that the real radiation distribution images may be obtained by our measurement system.

  • PDF