• Title/Summary/Keyword: 60 Hz

Search Result 1,300, Processing Time 0.028 seconds

De-Noising of Electroretinogram Signal Using Wavelet Transforms (웨이브렛 변환을 이용한 망막전도 신호의 잡음제거)

  • Seo, Jung-Ick;Park, Eun-Kyoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.203-207
    • /
    • 2012
  • Purpose: Electroretinogram(ERG) signal noise as well as conducting other bio-signal measurement were generated. It was intened to enhance the accuracy of retinal-related diagnosis with removing signal noise. Methods: Sampling signal was made with generating 60 Hz noise and white noise. The noise were removed using wavelet transforms and bandpass filter. De-noising frequency was compared with Fourier transform spectrum. Removed noises were compared numerically using SNR(signal to noise ratio). Results: The result compared Fourier transform spectrum was showed that 60 Hz noise removed completely and most of white noise was removed by wavelet transforms. 60 Hz and the white noise remained using bandpass filters. The result compared SNR showed that wavelet transforms was 22.8638 and bandpass filter was 4.0961. Conclusions: Wavelet transform showed less signal distortion in removing noise. ERG signal is expected to improve the accuracy of retinal-related diagnosis.

Changes in Photosynthetic Rate of Ginseng under Light Optical Properties in Smart Farms (스마트 팜에서의 광 특성에 따른 인삼의 광합성률 변화)

  • Lee, Jung-Min;Park, Jae-Hoon;Lee, Eung-Pill;Kim, Eui-Joo;Park, Ji-Won;You, Young-Han
    • Korean Journal of Ecology and Environment
    • /
    • v.53 no.3
    • /
    • pp.304-310
    • /
    • 2020
  • Smart farm is a high-tech type of plant factory that artificially makes environmental conditions suitable for the growth of plants and manages them to automatically produce the desired plants regardless of seasons or space. This study was conducted by identifying the effects of Hertz and Duty ratio on the photosynthetic rate of ginseng, a medicinal crop, to find the optimal conditions for photosynthetic responses in smart farms. The light sources consisted of a total of 10 chambers using LED system, with 4 R+B(red+blue) mixed lights and 6 R+B+W (red+blue+white) mixed lights. In addition, the Hertz of the R+B mixed light was treated at 20, 60, 180, 540, 1620 and 4860 hz respectively. The R+B+W mixed light was treated with 60, 180, 540, and 1620 hz. Afterwards, experiments were conducted with the duty ratio of 30, 50, and 70%. As a result, the photosynthetic rate of ginseng according to duty ratio and Hertz was the highest at 60 hz when duty ratio was set to 50%. On the other hand, that was the lowest when the duty ratio was 30% at the same 60 hz. In addition, the photosynthetic rates were highest in the R+B mixed light and R+B+W mixed light at 60 hz. Therefore, the condition with the highest photosynthetic rate of ginseng in smart farms is 60 hz when the duty ratio in R+B mixed light is 50%.

Ohmic Thawing of a Frozen Meat Chunk (Ohmic Heating을 이용한 동결육의 해동)

  • Yun, Cheol-Goo;Lee, Do-Hyun;Park, Ji-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.842-847
    • /
    • 1998
  • Ohmic thawing in combination with conventional water immersion thawing was investigated. Frozen meat chunks $(10{\times}10{\times}10{\;}cm)$ were immersed in a water reservoir $(12{\times}12{\times}12{\;}cm)$ which temperature was maintained at $10^{\circ}C{\;}or{\;}20^{\circ}C$, and were positioned between two stainless-steel electrodes $(10{\times}10{\;}cm)$ having no direct contact with the samples. Alternating current $(60{\;}V{\sim}210{\;}V)$ at various frequency $(60{\;}Hz{\sim}60{\;}kHz)$ was used to generate internal heat by the electrical resistance. When the frequency was fixed to 60Hz, thawing time was reduced as the voltage increased. Frequency changes gave no significant effect on thawing time. Ohmically-thawed samples treated with lower voltage showed lower drip loss and higher water holding capacity.

  • PDF

The development on Power supply for Pulsed $CO_2$ laser using half-rectified AC frequency control and leakage transformer (누설 변압기를 이용한 반파 AC 주파수 제어형 $CO_2$ 레이저의 전원장치 개발)

  • Chung, Hyun-Ju;Kim, Do-Wan;Lee, Dong-Hoon;Lee, Yu-Su;Kim, Hee-Je;Cho, Jung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.82-85
    • /
    • 2000
  • We introduce pulsed $CO_2$ laser power supply excited by half-wave rectified 60Hz AC discharge some advantage of cost and size compared to a typical pulsed power supply. AC frequency is adjusted from 10Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage AC discharge circuits is employed to avoid the HV sampling or switching. The control is achieved by using a ZCS circuit and a PIC one-chip microprocessor that control the gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to a high leakage inductance. The maximum laser output was obtained about 20W at the condition of total pressure, 18Torr and pulse repetition rate,60Hz.

  • PDF

A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary (누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구)

  • Chung, Hyeon-Ju;Lee, Dong-Hoon;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.9
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

Analysis of Acoustic Signals Produced by Corona and Series-arc Discharges (코로나와 직렬아크 방전에 의해 발생한 음향신호의 분석)

  • Jo, Hyang-Eun;Jin, Chang-Hwan;Park, Dae-Won;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.147-152
    • /
    • 2012
  • This paper dealt with the frequency component analysis of acoustic signals produced by corona and series-arc discharges as a diagnostic technique for closed-switchboards. Corona and series-arc discharge were simulated by a needle-plane electrode and an arc generator specified in UL1699, respectively. Acoustic signal was detected by a wideband acoustic sensor with a frequency bandwidth of 4 Hz~100 kHz (-3 dB). We analyzed frequency spectrums of the acoustic signals detected in various discharge conditions. The results showed that acoustic signals mainly exist in ranges from 30 kHz to 60 kHz. From the experimental results, an acoustic detection system which consists of a constant current power supply (CCP), a low noise amplifier (LNA) and a band pass filter was designed and fabricated. The CCP separates the signal component from the DC source of acoustic sensor, and the LNA has a gain of 40 dB in ranges of 280 Hz~320 kHz. The high and the low cut-off frequency are 30 kHz and 60 kHz, respectively. We could detect corona and series-arc discharges without any interference by the acoustic detection system, and the best frequency is considered in ranges of 30 kHz~60 kHz.

New Single-Phase Power Converter Topology for Frequency Changing of AC Voltage

  • Jou, Hurng-Liahng;Wu, Jinn-Chang;Wu, Kuen-Der;Huang, Ting-Feng;Wei, Szu-Hsiang
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.694-701
    • /
    • 2018
  • This paper proposes a new single-phase power converter topology for changing the frequency of AC voltage. The proposed single-phase frequency converter (SFC) includes a T-type multi-level power converter (TMPC), a frequency decoupling transformer (FDT) and a digital signal processor (DSP). The TMPC can convert a 60 Hz AC voltage to a DC voltage and then convert the DC voltage to a 50 Hz AC voltage. Therefore, the output currents of the two T-type power switch arms have 50 Hz and 60 Hz components. The FDT is used to decouple the 50 Hz and 60 Hz components. The salient feature of the proposed SFC is that only one power electronic converter stage is used since the functions of the AC-DC and DC-AC power conversions are integrated into the TMPC. Therefore, the proposed SFC can simplify both the power circuit and the control circuit. In order to verify the functions of the proposed SFC, a hardware prototype is established. Experimental results verify that the performance of the proposed SFC is as expected.

Partial Discharge Resistance According to Frequency Acceleration Deterioration of Epoxy/Layered Silicate Nanocomposites (에폭시/층상실리케이트 나노콤포지트의 주파수 가속열화에 따른 부분방전 저항성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1694-1699
    • /
    • 2013
  • Frequency accelerated partial discharge resistance (PDR) aging of epoxy/layered silicate nanocomposite with 1.5wt % additions of layered silicate was investigated in comparison with that of epoxy without layered silicate in terms of PD(partial discharge) erosion depth. It was found that the change in the erosion depth is far smaller in specimens with layered silicate than those without layered silicate nano particles. Frequency acceleration can be done from 60Hz to 1000Hz. But the depth of erosion is less proportional to frequency. Acceleration factor is almost 2 times between 500Hz and 1000Hz, but it is much less than about 8.3 times between 60Hz and 500Hz. This superior PD resistance is caused by the presence of nanofillers, anano-effect due to closely packed nanofillers, and strong chemical bonds at layered silicate nanofillers /resin interfaces.

A Study on the Conducted Noise of the Intrabuilding Power Line (건물내 전력선에 존재하는 전도성 잡음에 관한 연구)

  • 정호영;강창언
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.1
    • /
    • pp.55-62
    • /
    • 1991
  • In this paper, the characteristics of the conducted noise on the intrabuilding power line are measured and analyzed with three steps. In the result, the conducted noise on the intrabuilding power line is mainly divided into three types: the random disturbance which is the background noise with full band spectrum, the harmonic noise correlated with the 60Hz power frequency, and the periodic impulse noise of 120 Hz synchronized with the 60Hz power frequency.

  • PDF

60 kHz Switching Operation of Two Paralleled 300 V/600 A SiC HEMTs in Full Bridge (2병렬 SiC HEMT를 이용한 300 V/600 A 풀브릿지 시스템의 60 kHz 스위칭 운전)

  • Yun, Jonghun;Yoo, Jiwon;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.93-95
    • /
    • 2019
  • 본 논문에서는 높은 스위칭 주파수에서의 SiC HEMT의 병렬 운전을 다룬다. 이를 위해 300 V/600 A SiC HEMT을 이용한 병렬 풀브릿지 시스템을 설계하고 검증한다. 병렬 운전시 발생하는 전류 불균형을 제한하기 위해 병렬 소자간 인덕턴스를 설계한다. 또한 최대 순시 손실을 계산하여 이를 방열할 수 있는 냉각 시스템을 구성한다. 더블 펄스 시험을 통해 설계된 시스템의 동적(dynamic) 전류 균형과 정적(static) 전류 균형을 평가한다. 60 kHz 스위칭 주파수에서의 500 Hz 600 A 교류 제어 실험을 통해 제어 성능과 순시 손실을 검증한다.

  • PDF