• Title/Summary/Keyword: 6 MV

Search Result 874, Processing Time 0.037 seconds

Compare to Evaluate the Imaging dose of MVCT and CBCT (Tomotherapy MVCT와 Linac CBCT의 Imaging dose 비교평가)

  • Yoon, Bo Reum;Hong, Mi Lan;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • Purpose : In case of the intensity modulated radiation therapy (IMRT) using Tomotherapy and linear accelerator (Linac), it was to compare and to evaluate the imaging dose of MVCT and CBCT that were performed daily for the correct set up of the patient. Materials and Methods : The human body model Phantom (Anderson rando Phantom, USA) was divided into the three parts as Head, Thorax, pelvis, and after GafChromic EBT3 film cut to the size of $0.5{\times}0.5cm2$.in the center of the recording area were situated on the ant, post, left, and right surface of the phantom and 2cm in depth from the ant, post, left, right, and center surface of the phantom, the surface dose and inner dose were measured repeatedly three times, respectively, using the tomotherapy (Hi Art) and the OBI of NovalisTx. The measured film calculated the output value by RIP version6.0 and then the average value of the dose was calculated by the one-way analysis of variance. Results : Using the human body model phantom, the results of MVCT and CBCT performance were that measurements of MVCT inner dose were showed $15.43cGy{\pm}6.05$ in the head, $16.62cGy{\pm}3.08$ in the thorax, $16.81cGy{\pm}5.24$ in the pelvis, and measurements of CBCT inner dose were showed $13.28{\pm}3.68$ in the head, from $13.66{\pm}4.04$ in the thorax, $15.52{\pm}3.52$ in the pelvis. The measurements of surface dose were showed in case of MVCT performance, $11.64{\pm}4.05$ in the head, $12.16{\pm}4.38$ in the thorax, $12.05{\pm}2.71$ in the pelvis, and in case of CBCT performance, $14.59{\pm}3.51$ in the head, $15.82{\pm}2.89$ in the thorax, $17.48{\pm}2.80$ in the pelvis, respectively. Conclusion : In case of Inner dose, the MVCT using MV energy showed higher than the CBCT using kV energy at 1.16 times in the head, at 1.22 times in the thorax, at 1.08 times in the pelvis, and in case of surface dose, the CBCT was higher than MVCT, at 1.25 times in the head, at 1.30 times in the thorax, at 1.45 times in the pelvis. Imaging dose was a small amount compared to the therapeutic dose but it was thought to affect partially to normal tissue because it was done in daily schedule. However, IMRT treatment was necessarily parallel with the IGRT treatment through the image-guide to minimize errors between planned and actual treatment. Thus, to minimize imaging dose that the patients receive, when planning the treatment, it should be set up a treatment plan considering imaging dose, or it must be performed by minimizing the scan range when shooting MVCT.

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

The Role of Radiotherapy for Carcinomas of the Gall Bladder and Extrahepatic Biliary Duct: Retrospective Analysis (담낭 및 간외담도계 악성종양의 방사선치료결과)

  • Jeong Hyeon Ju;Lee Hyun Ju;Yang Kwang Mo;Suh Hyun Suk;Kim Re Hwe;Kim Sung Rok;Kim Hong Ryong
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.43-49
    • /
    • 1998
  • Purpose : Carcinomas arising in the gall bladder(GB) or extrahepatic biliary ducts are uncommon and generally have a poor prognosis. The overall 5-year survival rates are less than $10\%$. Early experiences with the external radiation therapy demonstrated a good palliation with occasional long-term survival. The present report describes our experience over the past decade with irradiation of primary carcinomas of the gallbladder and extrahepatic biliary duct. Materials and Methods : From Feb. 1984 to Nov. 1995, thirty-three patients with carcinoma of the GB and extrahepatic biliary duct were treated with external beam radiotherapy with curative intent at our institution. All patients were treated with 4-MV linear accelerator and radiation dose ranged from 31.44Gy to 54.87Gy(median 44.25Gy), and three Patients received additional intraluminal brachytherapy(range, 25Gy to 30Gy). Twenty-seven Patients received postoperative radiation. Among 27 patients, Sixteen patients underwent radical operation with curative aim and the rest of the patients either had bypass surgery or biopsy alone. In seventeen patients, adjuvant chemotherapy was used and eleven patients were treated with 5-FU, mitomycin and leucovorin. Results : Median follow up period was 8.5 months(range 2-97 months). The overall 2-year and 5-year survival rates in all patients were $29.9\%$ and $13.3\%$ respectively. In patients with GB and extrahepatic biliary duct carcinomas, the 2-year survival rates were $34.5\%$ and $27.8\%$ respectively. Patients who underwent radical operation showed better 2-year survival rates than those who underwent palliative operation($43.8\%\;vs.\;20.7\%$), albeit statistically insignificant(p>0.05). The 2-year survival rates in Stage I and II were higher than in Stage III and IV with statistical significance(p<0.05). Patients with good performance status in the beginning showed significantly better survival rates than those with worse status(p<0.05). The 2-year survival rates in combined chemotherapy group and radiation group were $40.5\%$ and $22.0\%$ respectively. There was no statistical differences in two groups (p>0.05). Conclusion : The survival of patients with relatively lower stage and/or initial good performance was significantly superior to that of others. We found an statistically insignificant trend toward better survival in patients with radical operation and/or chemotherapy, More radical treatment strategies, such as total resection with intensive radiation and/or chemotherapy may offer a better chance for cure in selective patients with carcinoma of gall bladder and extrahepatic biliary ducts.

  • PDF

Effect of Flooding and Organic Matter to the Release of Iron, Manganese, and Silica in Soils (침수처리(湛水處理) 및 유기물(有機物) 첨가(添加)가 답토양(畓土壤)의 Fe, Mn 및 SiO2의 용출량(溶出量)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Park, Y.S.;Oh, W.K.;Park, N.J.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 1968
  • A low yielding paddy soil was water logged at $30{\pm}2^{\circ}C$ with soluble starch as a easily decomposable organic matter for 3 weeks in the laboratory. The relation of pH and Eh changes and soluble iron, manganese and silica was investigated. The experimental results obtained were summarized as follows; 1. When organic matter was applied, reduction of the soil was severer, that is, Eh value was lower by 200 mv. for a week in the beginning of submergence. 2. pH of the untreated soil was dropped a little just after submergence, and then gradually increased to 60. When treated, pH was increased due to abrupt drop of Eh in the beginning but decreased to 4.5 after a week, and became constant at this pH value. 3. Slight increase in soluble iron, manganese and silica was observed in the untreated soil whereas soluble iron, manganese and silica in the treated soil were increased about 20, 10, and 3 times, respectively. 4. When soluble starch was treated, pH and soluble silica or manganese was highly correlated[($H^+$) and Mn ${\gamma}=0.734^{**}$, ($H^+$) and $SiO_2$ ${\gamma}=0.923^{**}$] and below pH 5.0, release of these element was rapidly increased.

  • PDF

A Study on the Chemical Characteristics of High and Low Productive Paddy Soil (고수확답(高收穫畓)과 저수확답(低收穫畓) 토양(土壤)의 화학적(化學的) 성질(性質) 비교(比較))

  • Oh, W.K.;Park, Y.S.;Chung, D.H.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.1 no.1
    • /
    • pp.7-11
    • /
    • 1968
  • A high and low productive paddy soils were waterlogged at $30{\pm}2^{\circ}C$ for 35 days in the laboratory. The relation of pH and Eh changes, ferrous iron and ammonium nitrogen of these soils was studied. The results obtained are summarized as follows: 1. pH value has been increased for 13 days of incubation and after 13 th day, they maintain their pH value without marked change, and pH value of high productive soil is higher than that of low productive soil by 0.25-0.30. 2. Eh value has been decreased for 10 days of incubation and then they also maintain their Eh value without marked change. Eh value of high productive soil is lower than that of low productive soil by 50-70 mv. 3. In both soils ferrous iron formed under submerged condition increased steeply within 4-5 days of incubation and after that they maintain their content without marked change. The $Fe^{+{+}}$ content of high productive soil is higher than low productive soil by 1.0 mg/1 gr soil. 4. $NH_4{^{-N}}$ formed under submerged condition rapidly increased in the early period of incubation and after that decreased to a certain level and maintain their content, but its content of high productive soil is higher than that of low productive soil by $20-25{\gamma}/1\;gr$ at the early stage and lower at the latter period by $10-15{\gamma}/1\;gr$.

  • PDF

Effects of Dry Matter Content of Liquid Swine Manure on Dry Matter Yield and Nutritive Value of Italian Ryegrass, Rye and Oat, and the Chemical Characteristics of Soil in Jeju (제주지역에서 건물 함량이 다른 돈분 액비 시용이 이탈리안 라이그라스, 호밀 및 귀리의 수량, 사료가치 및 토양 특성에 미치는 영향)

  • Song, Sang-Taek;Kim, Moon-Chul;Hwang, Kyoung-Jun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.26 no.3
    • /
    • pp.159-170
    • /
    • 2006
  • This study was conducted to investigate the effects of two dry matter levels of liquid swine manure on dry matter yield and nutritive value of Italian ryegrass, rye and oats, and the chemical characteristics of soil in Jeju. This experiment tested in split plot design. Three forage crops (Italian ryegrass, rye and oats) were the main plot and four fertilizers (no fertilizer=T0, chemical fertilizer=T1, liquid swine manure with DM 2.7%=T2 and liquid swine manure with DM 5.9 %=T3) were the sub plots. Yield and nutrient contents of forage crops and soil properties were determined. Application of liquid swine manure containing 5.9% dry matter resulted in highest DM yield in all three forage crops species compared with the other treatments (p<0.01). Crude protein content(%) and crude protein yield(kg/ha) of forage crops were highest in rye compared with the other forage crops species(p<0.01). K and Mg contents of soil were higher(p<0.01) in rye than in the other species while Na contents was higher(p<0.01) in Italian ryegrass than others. Mg content of soil appeared higher in rye than in the others and higher(p<0.05) in forage crops applied with liquid manure containing 2.7% DM compared with the other species. $NO_3-N$ contents in soil was lower in rye than the other species and higher in species with chemical fertilizer. These findings indicate that most of liquid swine manure produced on local pig farms containing low levels of dry matter and other nutrients suggest a low efficiency of its use as a fertilizer. The liquid swine manure is recommended as a fertilizer for rye production in winter, compared with Italian ryegrass or oat.

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

The Result of Radiotherapy for Pituitary Adenoma (뇌하수체 선종의 방사선치료 결과)

  • Lee, Hyun-Joo;Yang, Kwang-Mo;Cho, Heung-Lae;Shon, Seung-Chang;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.297-303
    • /
    • 1997
  • Purpose : To evaluate the prognostic factors for disease-free survival and long-term results of radiotherapy for pituitary adenoma. Methods and Materials : The study involved a retrospective review of out-come in a series of 27 patients with pituitary adenoma, between 1984 and 1995 at Paik hospital. The study included 20 patients treated with surgery and postoperative radiotherapy and 7 with radiotherapy alone. The patients were followed for 12-146 months (median : 97 months). Seventeen were men and 10 were women. The numbers of functioning and nonfunctioning pituitary adenorna were 22 and 5 respectively and those of microadenoma and macroadenoma were 4 and 23 respectively. The radiation doses of 5040-5580cGy (median : 5040cGy) were deliverd over 5-7 weeks, using 4MV LINAC. The prognostic factors were analyzed by log-rank test. Results: For radiation therapy alone, the 5YSR was 100% and progression free survival rate was 85.8%, The tumor was controlled in 6/7 (85.8%). For surgery and postoperative radiotherapy. the 5YSR, progression free survival rate and local control rate were 95%, 84.8%, and 89.5% respectively. The parameters of tumor size, hormone secretion, radiation dose. radiotherapy field size were evaluated in a uni- and multivariate analysis and all the factors were not statisticaIty significant (P>0.05). Eleven of 12 (92%) with visual field defect experienced normalization or improvement, and 5 for 7 evaluabie patients with hyperprolactinoma achived normalization in 4 and decrement in S patients. Only 2 patients developed mild degree of Panhypopituitarism. Conclusion: The radiotherapy appears to be effective in controiling clinical symptoms and signs resulting from pituitary adenoma. Local control rate with radiotherapy alone or with surgery and postoperative radiotherauy was comparable. There was a trend toward high recurrence rate in Patients with nonfunctioning or prolactin secretion tumor and larger radiation field sizes.

  • PDF

The Role of Air-Vacuum Cushion Device in Patients with Rectal Cancer in Radiation Therapy (직장암 환자에서 방사선치료시 Air-vacuum Cushion의 유용성)

  • Kim Ki-Hwan;Cho Moon-June;Kang No-Hyun;Kim Dong-Wuk;Kim Jun-Sang;Jang Ji-Young;Kim Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.287-292
    • /
    • 2001
  • Prupose : We analyzed setup errors induced by using air-vacuum cushion as immobilization device in patients with rectal cancer. Materials and methods : We had treated the twenty patients with rectal cancer by 6 MV, 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at prone position. They were separated to two groups, control group, 10 patients using styrofoam, and test group, 10 patients using styrofoam and air-vacuum cushion. We measured errors of posterior field for x, y axis and lateral field for z, y axis with simulation film and EPID image using a matching technique. Results : In control group, the mean displacement values of pelvic bone landmark for x axis and y axis were 0.02 mm. 0.78 mm, respectively and the standard deviations of systematic error were 2.13 mm, 2.40 mm, respectively and the standard deviation of random error were 1.46 mm. 1.51 mm, respectively. In test group, the mean displacement values of x axis and y axis were -0.33 mm. 0.81 mm, respectively and the standard deviations of systematic error were 1.71 mm, 3.08 mm, respectively and the standard deviations of random errors were 1.40 mm. 1.88 mm, respectively. The mean displacement values of z axis and y axis were 2.98 mm. 0.74 mm, respectively and the standard deviations of systematic error were 4.75 mm, 2.65 mm, respectively and standard deviations of random error were 2.69 mm. 1.86 mm, respectively. The statistical difference of field size by using air vacuum cushion between two groups in posterior direction and lateral direction was not shown. Conclusion : We think that use of air-vacuum cushion may not be an advantage for improving setup accuracy in rectal cancer patients.

  • PDF

Assessment on Accuracy of Stereotactic Body Radiation therapy (SBRT) using VERO (VERO system을 이용한 정위적 체부 방사선치료(SBRT)의 정확성 평가)

  • Lee, Wi Yong;Kim, Hyun Jin;Yun, Na Ri;Hong, Hyo Ji;Kim, Hong Il;Baek, Seung Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • Purpose: The present study aims to assess the level of coherency and the accuracy of Point dose of the Isocenter of VERO, a linear accelerator developed for the purpose of the Stereotactic Body Radiation Therapy(SBRT). Materials and Method: The study was conducted randomly with 10 treatment plans among SBRT patients in Kyungpook National University Chilgok Hospital, using VERO, a linear accelerator between June and December, 2018. In order to assess the equipment's power stability level, we measured the output constancy by using PTW-LinaCheck, an output detector. We also attempted to measure the level of accuracy of the equipment's Laser, kV(Kilo Voltage) imaging System, and MV(Mega Voltage) Beam by using Tofu Phantom(BrainLab, Germany) to assess the accuracy level of geometrical Isocenter. We conducted a comparative analysis to assess the accuracy level of the dose by using an acrylic Phantom($30{\times}30{\times}20cm$), a calibrated ion chamber CC-01(IBA Dosimetry), and an Electrometer(IBA, Dosimetry). Results: The output uniformity of VERO was calculated to be 0.66 %. As for geometrical Isocenter accuracy, we analyzed the error values of ball Isocenter of inner Phantom, and the results showed a maximum of 0.4 mm, a minimum of 0.0 mm, and an average of 0.28 mm on X-axis, and a maximum of -0.4 mm, a minimum of 0.0 mm, and an average of -0.24 mm on Y-axis. A comparison and evaluation of the treatment plan dose with the actual measured dose resulted in a maximum of 0.97 % and a minimum of 0.08 %. Conclusion: The equipment's average output dose was calculated to be 0.66 %, meeting the ${\pm}3%$ tolerance, which was considered as a much uniform fashion. As for the accuracy assessment of the geometric Isocenter, the results met the recommended criteria of ${\pm}1mm$ tolerance, affirming a high level of reproducibility of the patient's posture. The difference between the treatment plan dose and the actual measurement dose was calculated to be 0.52 % on average, significantly less than the 3 % tolerance, confirming that it obtained predicted does. The current study suggested that VERO equipment is suitable for SBRT, and would result in notable therapeutic effect.