• Title/Summary/Keyword: 6

Search Result 289,859, Processing Time 0.138 seconds

Automatic Attack Reaction Tool Based on IPv6 (IPv6 기반 자동화된 공격 대응도구)

  • Lee Hong-Kyu;Koo Hyang-Ohk;Kim Sun-Young;Kim Young-Gi;Oh Chang-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.3 s.35
    • /
    • pp.249-257
    • /
    • 2005
  • In this paper proposed automated attack reaction tool based on IPv6. Currently, much researches are performing focused on application program and standardization for IPv6. But, It is not enough for future IPv6 security. The proposed method detect attacks on IPv6 and conventional IPv4, therefore it is possible to protect personal information using automated reaction method. Usually, IDS just perform detection, therefore damages may be repeated. However, this paper considered the problems described above, and suggested solution for this problems. The proposed algorithm suggested in this paper is simulated on IPv6 network based on Linux. As a simulation result, it is proved that proposed algorithm can detect attacks efficiently.

  • PDF

Breakdown Characteristics of SF6 in Different State and Bubble Movements under AC High-Voltage

  • Choi, Eun-Hyeok;Lim, Chang-Ho;Yoon, Dae-Hee;Park, Kwang-Seo;Kim, Lee-Kook;Lee, Kwang-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.257-262
    • /
    • 2007
  • In this paper the experiments of breakdown characteristics by temperature change of $SF_6$ gas($GSF_6$), and $SF_6$ liquid ($LSF_6$) in model GIS (Gas Insulated Switchgear) are described. From the experiment's results, the breakdown characteristics classify the vapor stage of $SF_6$ according to Paschen's law, in which the gas & liquid coexisted stage of voltage value increases, resulting in much deviation and the breakdown of voltage ($V_B$) low stage as the interior of the chamber gets filled with a mixture of $SF_6$ that is not liquefacted and remaining air that cannot be ventilated. The ability of $LSF_6$ insulation is higher than the high-pressurized $SF_6$ gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubbles caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery that will be studied and developed in the future.

Dialkylaminomethylation of 1,4-Dihydropyridine (1,4-Dihydropyridine의 Dialkylaminomethyl화 유도체의 합성)

  • Suh, Jung-Jin;Hong, You-Hwa
    • YAKHAK HOEJI
    • /
    • v.33 no.5
    • /
    • pp.280-284
    • /
    • 1989
  • When 2,6-Dimethyl-4-(3'-nitrophenyl)-1,4-dihydropyridine-3,5-dicarboxylic acid 3-mono methyl ester(3) was reacted with dimethyl methylene ammonium chloride (5a) and $K_2CO_3$ in DMF, 2,6-dimethyl-4-(3'-nitrophenyl)-5-(N,N-dimethylamino)methyl-1,4-dihydropyridine-3-carboxylic acid methyl ester (6a) was obtained in 41% yield. As the same procedure with compound (3) and the other dialkylaminomethylating reagents (5b, c, d, e), 2,6-dimethyl-4-(3'-nitrophenyl)-5-(N,N-diethylamino)methyl-1,4-dihydropyridine-3-carboxylic acid methylester(6b), 2,6-dimethyl-4-(3'-nitrophenyl)-5-(1'-pyrrolidinyl)methyl-1,4-dihydropyridine-3-carboxylic acid methyl ester (6c), 2,6-dimethyl-4-(3'-nitrophenyl)-5-(1'-piperidinyl)methyl-1,4-dihydropyridine-3-carboxylic acid methyl ester (6d) and 2,6-dimethyl-4-(3'-nitrophenyl)-5-(1'-morpholinyl)methyl-1,4-dihydropyridine-3-carboxylic acid methyl ester (6e) were obtained in 28%, 49%, 48% and 18% yield respectively.

  • PDF

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF

Optimal Dietary Ratio of Spray Dried Plasma Protein (SDPP) and Dried Porcine Solubles (DPS) in Improving Growth Performance and Immune Status in Pigs Weaned at 21 Days of Age

  • Kim, J.D.;Hyun, Y.;Sohn, K.S.;Kim, T.J.;Woo, H.J.;Han, In K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.3
    • /
    • pp.338-345
    • /
    • 2001
  • An experiment was conducted to determine the optimal inclusion ratio of spray dried plasma protein (SDPP) and dried porcine solubles (DPS) for maximizing growth and improving immunity in weaned pigs. One hundred-fifty male (barrow) pigs were allotted in a completely randomized block design. Treatments were as follows: 1) control (6% SDPP), 2) S6D6 (6% SDPP+6% DPS), 3) S6D3 (6% SDPP+3% DPS), 4) S3D6 (3% SDPP+6% DPS) and 5) S3D3 (3% SDPP+3% DPS). Each treatment has 6 replicates with 5 pigs per replicate. Average daily gain (ADG) and average daily feed intake (ADFI) were highest, but not significantly different when pigs were fed a diet contained 6% SDPP and DPS from d 0 to 7 after weaning. Pigs fed the S6D3 diet showed better weight gain and feed intake than other treatments, especially compared with pigs fed S3D6 diet (p<0.05) from d 8 to 21 after weaning. For the overall experimental period, pigs fed the S6D3 diet showed the best improvement in ADG and ADFI. The digestibilities of dry matter (DM) and crude protein (CP) were higher in pigs fed the S6D6 diet than other diets from d 0 to 7 after weaning. However, pigs fed S6D3 diet showed higher DM, CP and essential amino acids (except methionine and arginine) digestibilities than pigs fed other diets from d 8 to 21 after weaning, although there was no significant difference. From d 8 to 21 after weaning, threonine, valine, isoleucine and leucine digestibilites were higher in S6D6 group, and phenyalanine, histidine, lysine and arginine digestibility were higher in S6D3 group than other groups. The ratio of CD4 and CD8 positive lymphocytes during the overall experimental period was independent of the ratio of SDPP and DPS. However, CD4+:CD8+ ratio was numerically lowered in pigs fed diet the S6D3 diet. Therefore, the present study suggests that an optimal inclusion ratio for maximizing growth performance and maintaining low immune status is 6% of SDPP and 3% of DPS in weaned pigs.

Comparison of Surface Fuel and Soil Layer Moisture after Rainfall in Broad-Leaved Forest at Young Dong Region (영동지역 활엽수림에서의 강우 후 지표연료의 습도변화 분석)

  • Kwon, Chun-Geun;Lee, Si-Young;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.49-60
    • /
    • 2012
  • The change in fuel moisture in accordance with the number of days after rainfall is an important factor in predicting forest fire dangers and supporting forest fire rangers. Therefore, in order to clear up these forest fire occurrence conditions, forest fire danger levels for surface fuel 0.6 cm or lower, 0.6~3.0 cm, 3.0~6.0 cm, and 6.0 cm or above by fallen leaves layer, humus layer, soil layer, and diameter after rainfall of 5.0 mm and higher in accordance with tree density in 2008, 2009 Spring/Autumn Young Dong region have been analyzed. Research showed an approximate 17 % fuel moisture which is a dangerous forest fire occurrence level after 5 days from rainfall in medium-density areas and 3 days after rainfall in loose-density areas of Spring time in the fallen leaves layer. On the other hand, the humus layer showed a 40 % or higher fuel humidity even after 6 days from rainfall regardless of the season, while the upper and lower parts of the soil layer had a little change. In loose-density areas with 0.6 cm or less surface fuel per diameter in Spring time, the fuel humidity displayed a dangerous level in fire forest occurrence after 3 days, and 4days in medium-density areas, and for loose-density areas with 0.6~3.0 cm surface fuel per diameter in Autumn time it showed a dangerous level in forest fire occurrence after 3 days, and for medium-density areas, 5 days. In the case of 3.0~6.0 cm of fuel moisture per diameter in both Spring and Autumn times, even after 6 days, low and medium-density areas showed that they maintain fuel moisture and therefore the dangers of forest fires were very low, and in the case of 6.0 cm or higher, it showed 25 % or higher fuel moisture even after 6 days from rainfall regardless of the season.

Effect of n-6/n-3 fatty acid ratio on metabolic partitioning in hyperlipidemic rats (n-6/n-3 지방산 비율이 고지혈증 랫드의 지질대사 분할에 미치는 영향)

  • Lee, Seunghyung;Um, Kyung-Hwan;Park, Byung-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.643-653
    • /
    • 2018
  • This study was investigated the mechanism of action of n-6/n-3 fatty acid ratio on the metabolic partitioning of blood glycerolipids by in vivo monitoring technique in hyperlipidemic animal model rats. The ratio of cholesteryl 14C-oleate metabolized in the liver of total glycerolipids was lower in the order of n-6/n-3 ratios of 4:1, 15:1, 30:1 and control group (p<0.05). The secretion amount of phospholipid was higher in the order of n-6/n-3 ratio 4:1, 15:1, 30:1 than the control (p<0.05). The secretion amount of triglyceride was lower in especially 4:1, in order of n-6/n-3 4:1, 15:1 and 30:1 compared with the control. The ratio of phospholipid partitioning to total glycerolipid was high in orfer of n-6/n-3 ratio 4:1, 15:1, 30:1 and control (p<0.05). The triacylglycerol partitioning (%) via liver was higher 72.97, 75.93, 78.12% in n-6/n-3 4;1, 15:1, 30:1, respectively than the control of 82.25%, according to increased n-6/n-3 (p<0.05). The phospholipid partitioning (%) was lower 25.15, 18.87, 18.15% in n-6/n-3 4;1, 15:1, 30:1, respectively, compared to control 11.04%, according to increased n-6/n-3 (p<0.05).

Properties of Al Doped LiMn2O4 Powders Prepared by Spray Pyrolysis Process (분무열분해 공정에 의해 합성된 Al이 치환된 LiMn2O4 분말의 특성)

  • Ju, Seo Hee;Jang, Hee Chan;Kang, Yun Chan
    • Korean Chemical Engineering Research
    • /
    • v.47 no.1
    • /
    • pp.84-88
    • /
    • 2009
  • Al doped $LiMn_2O_4$ cathode powders with fine size were synthesized by an ultrasonic spray pyrolysis method from the spray solution with citric acid and ethylene glycol. The as-prepared powders with spherical shape, porous structure and micron size turned into $LiMn_{11/6}Al_{1/6}O_4$ powders with micron size and regular morphology after post-treatment above $800^{\circ}C$. The $LiMn_{11/6}Al_{1/6}O_4$ powders had low initial discharge capacity of 94 mAh/g at a post-treatment temperature of $700^{\circ}C$. As the post-temperature increased from $750^{\circ}C$ to $1,000^{\circ}C$, the initial discharge capacities of the $LiMn_{11/6}Al_{1/6}O_4$ powders changed from 103 to 117 mAh/g. The $LiMn_{11/6}Al_{1/6}O_4$ powders had the maximum discharge capacity at a post-treatment temperature of $750^{\circ}C$. However, the $LiMn_{11/6}Al_{1/6}O_4$ powders post-treated at a temperature of $900^{\circ}C$ had the good cycle properties. The discharge capacities of the $LiMn_{11/6}Al_{1/6}O_4$ powders dropped from 107 to 100 mAh/g (93% capacity retention) by the 70th cycle at a current density of 0.1 C.

Effect of Electroacupuncture at SP-6 with Different Durations on Minimum Alveolar Concentration and the Cardiovascular System under Isoflurane Anesthesia in Dogs (개에서 Isoflurane 마취시 SP-6 혈위의 전침자극시간이 최소폐포농도 및 심맥관계에 미치는 영향)

  • Jeong, Seong-Mok
    • Journal of Veterinary Clinics
    • /
    • v.19 no.3
    • /
    • pp.283-289
    • /
    • 2002
  • The effects of electroacupuncture (EA) at SP-6 with different durations on the minimum alveolar concentration (MAC) and on the cardiovascular system were evaluated in dogs under isoflurane anesthesia. Eight healthy male beagles were randomly assigned to four study groups (n = 5/group) with washout period of 7 days for recovery and anesthetic withdrawal between experiments. Four study groups were control, nonacupoint electrical stimulation (NA), EA for 30 minutes (SP-6) and continuous EA for 70 or 90 minutes (SP-6C). For the nonacupoint electrical stimulation group, needles were inserted into the nonacupoint at the muscle bellies of left triceps brachii and right quadriceps femoris. MAC and cardiovascular parameters were determined after EA at SP-6 acupoint and at nonacupoint. Thirty minutes of EA and continuous EA until re-determination of MAC at SP-6 acupoint lowered the MAC of isoflurane by 21.3$\pm$8.0% and 16.1$\pm$4.6%, respectively (p<0.05). The decrements in MAC values were not significantly different between two EA groups. However, electrical stimulation of nonacupoint did not induce a significant change in MAC. In SP-6 and SP-6C groups, significant changes in cardiovascular parameters were not observed. These results indicate that EA at SP-6 have an advantage in isoflurane anesthesia in terms of reducing the requirement for anesthetics and minimizing cardiovascular side effects. EA for 30 minutes at maximum might be the sufficient time to produce acupuncture analgesia.

Role of interleukin-6 in orthodontically induced inflammatory root resorption in humans

  • Kunii, Ryuichi;Yamaguchi, Masaru;Tanimoto, Yasuhiro;Asano, Masaki;Yamada, Kunihiko;Goseki, Takemi;Kasai, Kazutaka
    • The korean journal of orthodontics
    • /
    • v.43 no.6
    • /
    • pp.294-301
    • /
    • 2013
  • Objective: To determine the interleukin (IL)-6 levels in gingival crevicular fluid (GCF) of patients with severe root resorption after orthodontic treatment and investigate the effects of different static compressive forces (CFs) on IL-6 production by human periodontal ligament (hPDL) cells and the influence of IL-6 on osteoclastic activation from human osteoclastic precursor (hOCP) cells in vitro. Methods: IL-6 levels in GCF samples collected from 20 patients (15 and 5 subjects without and with radiographic evidence of severe root resorption, respectively) who had undergone orthodontic treatment were measured by ELISA. The levels of IL-6 mRNA in hPDL cells and IL-6 protein in conditioned medium after the application of different uniform CFs (0, 1.0, 2.0, or 4.0 $g/cm^2$ for up to 72 h) were measured by real-time PCR and ELISA, respectively. Finally, the influence of IL-6 on mature osteoclasts was investigated by using hOCP cells on dentin slices in a pit-formation assay. Results: Clinically, the IL-6 levels were significantly higher in the resorption group than in the control group. In vitro, IL-6 mRNA expression significantly increased with increasing CF. IL-6 protein secretion also increased in a time- and magnitude-dependent manner. Resorbed areas on dentin slices were significantly greater in the recombinant human IL-6-treated group and group cultured in hPDL cell-conditioned medium with CF application (4.0 $g/cm^2$) than in the group cultured in hPDL cell-conditioned medium without CF application. Conclusions: IL-6 may play an important role in inducing or facilitating orthodontically induced inflammatory root resorption.