• Title/Summary/Keyword: 510(k)

Search Result 1,195, Processing Time 0.031 seconds

A Study on the Characteristics of Flows around Building Groups Using a CFD Model (CFD 모델을 이용한 건물군 주변의 흐름 특성 연구)

  • Lee, Hankyung;Kim, Jae-Jin;Lee, Young-Gon
    • Atmosphere
    • /
    • v.25 no.3
    • /
    • pp.501-510
    • /
    • 2015
  • In this study, the characteristics of flows around building groups are investigated using a computational fluid dynamics (CFD) model. For this, building groups with different volumetric ratios in a fixed area are considered. As the volumetric ratio of the building group increases, the region affected by the building group is widened. However, the wind-speed reduced area rather decreases with the volumetric ratio near the ground bottom (z ${\lesssim}$ 0.7H, here, H is the height of the building group) and, above 0.7H, it increases. As the volumetric ratio decreases (that is, space between buildings was widened), the size of recirculation region decreases but flow recovery is delayed, resulting in the wider wind-speed reduced area. The increase in the volumetric ratio results in larger drag force on the flow above the roof level, consequently reducing wind speed above the roof level. However, above z ${\gtrsim}$ 1.7H, wind speed increases with the volumetric ratio for satisfying mass conservation, resultantly increasing turbulent kinetic energy there. Inside the building groups, wind speed decreased with the volumetric ratio and averaged wind speed is parameterized in terms of the volumetric ratio and background flow speed. The parameterization method is applied to producing averaged wind speed for 80 urban areas in 7 cities in Korea, showing relatively good performance.

Proposal of new ground-motion prediction equations for elastic input energy spectra

  • Cheng, Yin;Lucchini, Andrea;Mollaioli, Fabrizio
    • Earthquakes and Structures
    • /
    • v.7 no.4
    • /
    • pp.485-510
    • /
    • 2014
  • In performance-based seismic design procedures Peak Ground Acceleration (PGA) and pseudo-Spectral acceleration ($S_a$) are commonly used to predict the response of structures to earthquake. Recently, research has been carried out to evaluate the predictive capability of these standard Intensity Measures (IMs) with respect to different types of structures and Engineering Demand Parameter (EDP) commonly used to measure damage. Efforts have been also spent to propose alternative IMs that are able to improve the results of the response predictions. However, most of these IMs are not usually employed in probabilistic seismic demand analyses because of the lack of reliable Ground Motion Prediction Equations (GMPEs). In order to define seismic hazard and thus to calculate demand hazard curves it is essential, in fact, to establish a GMPE for the earthquake intensity. In the light of this need, new GMPEs are proposed here for the elastic input energy spectra, energy-based intensity measures that have been shown to be good predictors of both structural and non-structural damage for many types of structures. The proposed GMPEs are developed using mixed-effects models by empirical regressions on a large number of strong-motions selected from the NGA database. Parametric analyses are carried out to show the effect of some properties variation, such as fault mechanism, type of soil, earthquake magnitude and distance, on the considered IMs. Results of comparisons between the proposed GMPEs and other from the literature are finally shown.

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • v.8 no.6
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

Femoral Nerve Injury after Rectus Abdominis Muscle Slap Harvesting: A Case Report (복직근 유리피판 거상 후 합병된 대퇴 신경손상 1례)

  • Kim, Jino;Lew, Dae Hyun;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.510-513
    • /
    • 2006
  • Purpose: The Rectus abdominis muscle free flap is utilized in various reconstruction surgeries due to easiness in harvesting, consistency of vascular pedicle and reduced donor site morbidity. But rarely, femoral nerve injury during rectus abdominis harvesting can be resulted. We report a case of femoral nerve injury after rectus muscle harvesting and discuss the injury mechanism with the follow-up process of this injury. Methods: To reconstruct the defect of middle cranial base after wide excision of cystic adenocarcinoma of the external ear, rectus muscle free flap was havested in usual manner. To achieve a long vessel, inferior epigastric artery was dissected to the dividing portion of femoral artery and cut. Results: One week after the surgery, the patient noted sensory decrease in the lower leg, weakness in muscle strength, and disabilities in extension of the knee joint resulting in immobilization. EMG and NCV results showed no response on stimulation of the femoral nerve of the left leg, due to the defects in femoral nerve superior to the inguinal ligament. With routine neurologic evaluations and physical therapy, on the 75th day after the operation, the patient showed improvement in pain, sensation and muscle strength, and was able to move with walking frame. In 6 months after the operation, recovery of the muscle strength of the knee joint was observed with normal flexion and extension movements. Conclusion: Rarely, during dissection of the inferior epigastric artery, injuries to the femoral nerve can be resulted, probably due to excessive traction or pressure from the blade of the traction device. Therefore, femoral nerve injury can be prevented by avoiding excessive traction during surgery.

A Study on the Development and Surface Roughness of Roller Cam SCM415 by 5-Axis Machining (5축 가공에 의한 SCM415 롤러 캠 개발과 표면조도 연구)

  • Kim, Jin Su;Lee, Dong Seop;Kang, Seong Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.4
    • /
    • pp.397-402
    • /
    • 2013
  • In this study, we carried out the each lines of section, using GC (green silicon carbide) whetstone, the SCM415 material which separated by after and before heat treatments process, in 3+2 axis machining centers for integrated grinding after cutting end mill works, the spindle speed 8000 rpm and feed rate 150 mm/min. For the analysis of the centerline average roughness (Ra), we measured by 10 steps stages. Using Finite element analysis, we found the result of the load analysis effect of the assembly parts, when applied the 11 kg's load on both side of the ATC (Automatic tool change) arm. The result is as follows. For the centerline average roughness (Ra) in the non-heat treatment work pieces, are appeared the most favorable in the tenth section are $0.510{\mu}m$, that were shown in the near the straight line section which is the smallest deformation of curve. In addition, the bad surface roughness appears on the path is to long by changing angle, the more inclined depth of cut, because the chip discharging is not smoothly.

COMPARISON OF MAXIMUM OCCLUSAL FORCES ON OSSEOINTEGRATED IMPLANT SUPPORTED FIXED PROSTHESES AND NATURAL TEETH (골유착성 임플랜트 지지 고정성 보철물과 자연치의 최대교합력 비교)

  • Kwon Young-Sook;Hwang Sun-Hong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.498-510
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the maximum occlusal force implant prostheses to natural teeth. Material and Method: Fifty nine patients treated either with $Br{\aa}anemark$ implants and ITI implants during the recent ten years were involved in this study. The maximum occlusal force were measured with unilateral bite force recorder and dental prescale system. Results: 1. The maximum occlusal forces of the implant prostheses and natural teeth were not significantly different where measured with unilateral bite force recorder and dental prescale system. 2. The maximum occlusal forces were not significantly different between $Br{\aa}nemark$ implant and ITI implant prostheses. 3. The maximum occlusal forces of the implant prostheses had lower when compared with natural teeth during 1-6 months functional periods when measured with the unilareral bite force recorder(P<0.05) and 1-12 months functional periods when measured with the dental prescale system(P<0.05). After these periods there was not statistical significant difference between the implant prostheses and natural teeth. 4. The maximum occlusal forces of the wide diameter implant prostheses were higher than the maximum occlusal forces of the regular diameter implant prostheses when measured with dental prescale system(P<0.05), but there was no significant difference between the wide diameter and the regular diameter implant prostheses when measured with unilateral bite force recorder. 5. The maximum occlusal forces of the single implant prostheses were not significantly different with the splinting implants prostheses. 6. The maximum occlusal forces of the implant prostheses were not significantly different by age and sex. 7. There was significantly different between maximum occlusal forces measured with unilateral bite force recorder and dental prescale system(P<0.0001) but there was positive correlation(r=0.52. P<0.05). Conclusion: The maximum occlusal forces of the implant prostheses were not significantly different to natural teeth during clenching and unilateral maximum biting.

EFFECT OF DEPOSITION METHODS ON PHYSICAL PROPERTIES OF POLYCRYSTALLINE CdS

  • Lee, Y.H.;Cho, Y.A.;Kwon, Y.S.;Yeom, G.Y.;Shin, S.H.;Park, K.J.
    • Journal of Surface Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.862-868
    • /
    • 1996
  • Cadmium sulfide is commonly used as the window material for thin film solar cells, and can be prepared by several techniques such as sputtering, spray pyrolysis, close spaced sublimation (CSS), thermal evaporation, solution growth methods, etc. In this study, CdS films were deposited by thermal evaporation, close spaced sublimation, and solution growth methods, respectively, and the effects of the methods on physical properties of polycrystalline CdS deposited on ITO/glass were investigated. Also, the effects of variously prepared CdS thin films on the physical properties of CdTe deposited on the CdS were investigated. The thickness of polycrystalline CdS films was maintained at $0.3\mu\textrm{m}$ except for the solution grown CdS when $0.2\mu\textrm{m}$ thick CdS was deposited. After the deposition, all the samples were annealed at $400^{\circ}C$ or $500^{\circ}C$ in H2 atmosphere. To investigate physical properties of the deposited and annealed CdS thin films, UV-VIS spectro-photometry, X-ray diffractometry (XRD), and Auger electron spectroscopy (AES), and cross sectional transmission electron microscopy(XTEM) were used to analyze grain size, crystal structure, preferred orientation, optical properties, etc. The annealed CdS showed the bandedge transition at 510nm and the optical transmittance high than 80% for all of the variously deposited films. XRD results showed that CdS thin films variously deposited and annealed had the same hexagonal structures, however, showed different preferred orientations. CSS grown CdS had [103] preferred orientation, thermally evaporated CdS had [002], and CdS grown by the solution growth had no preferred orientation. The largest grain size was obtained for the CSS grown CdS while the least grain size was obtained for the solution grown CdS. Some of the physical properties of CdTe deposited on the CdS thin film such as grain size at the junction and grain orientation were affected by the physical properties of CdS thin films.

  • PDF

Differential Diagnosis of Acute Liver Failure in Children: A Systematic Review

  • Berardi, Giuliana;Tuckfield, Lynnia;DelVecchio, Michael T.;Aronoff, Stephen
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.23 no.6
    • /
    • pp.501-510
    • /
    • 2020
  • Purpose: To develop a probability-based differential diagnosis for pediatric acute liver failure (PALF) based on age and socioeconomic status of the country of origin. Methods: Comprehensive literature search using PubMed, EMBASE, and SCOPUS databases was performed. Children 0-22 years of age who met PALF registry criteria were included. Articles included >10 children, and could not be a case report, review article, or editorial. No language filter was utilized, but an English abstract was required. Etiology of PALF, age of child, and country of origin was extracted from included articles. Results: 32 full text articles were reviewed in detail; 2,982 children were included. The top diagnosis of PALF in developed countries was acetaminophen toxicity (9.24%; 95% CredI 7.99-10.6), whereas in developing countries it was Hepatitis A (28.9%; 95% CredI 26.3-31.7). In developed countries, the leading diagnosis of PALF in children aged <1 year was metabolic disorder (17.2%; 95% CredI 10.3-25.5), whereas in developing countries it was unspecified infection (39.3%; CredI 27.6-51.8). In developed countries, the leading diagnosis in children aged >1 year was Non-A-B-C Hepatitis (8.18%; CredI 5.28-11.7), whereas in developing countries it was Hepatitis A (32.4%; CredI 28.6-36.3). Conclusion: The leading causes of PALF in children aged 0-22 years differ depending on the age and developmental status of their country of origin, suggesting that these factors must be considered in the evaluation of children with PALF.

Prevalence of Sarcocystis infections in the slaughtered cattle in Cheju (제주지역(濟州地域) 도축우(屠畜牛)의 주육포자충(住肉胞子蟲) 감염실태조사(感染實態調査))

  • Yang, Jae-hyun;Kang, Young-bai;Wee, Sung-hwan;Lee, Seung-taek;Kim, Kong-sik
    • Korean Journal of Veterinary Research
    • /
    • v.30 no.4
    • /
    • pp.507-510
    • /
    • 1990
  • A preliminary survey of Sarcocystis species in the slaughtered cattle in Cheju was undertaken during May through October 1989, using digested diagnostic technique for the heart, the esophagus and the dorsal muscles of the neck specimens digested in 0.5% trypsin solution. The results obtained were summarized as follows. 1. The overall infection rate of Sarcocystis in a total of 218 slaughtered cattle was as high as 36.7% with the highest frequencies in the esophagus muscles(21. 6%), followed by in the dorsal muscles of the neck(19.1%) and in the heart rnuscles(17.9%). 2. Age difference was noticed as 64.3% in the cattle older than five years in comparison with 41.7%, 34.4%, in the group of two to four years and in the group of younger than two years respectively. 3. It was also noticed that the prevalence in the Brahman cross breed was higher(40.0%) than in any other breeds. 4. Regional distribution of Sarcocystis infections was observed as 75.0% in south-east area, 50.0% 44.7%, 35.0%, 32.0% and 20.6% in the areas of Seogwipo city, north-west, south-west, Cheju city and northeast area respectively. 5. According to the type of rearing the infection rate in the ranch type farm was noticed with and in the stock farms(36.2%).

  • PDF

Effect of Sawdust Culture on Oak Mushroom, Lentinula edodes (Berk.) Pegler by Inoculation of the Liquid Spawn (액체종균(液體種菌) 접종(接種)에 의한 표고톱밥재배(栽培) 효과(效果))

  • Lee, Tai-Soo;Cho, Nam-Seok;Min, Du-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.19-28
    • /
    • 1998
  • For cultivation on sawdust-bed of oak-mushroom until present time, inoculation of spawn on sawdust bed has been performed by sawdust spawn. But, liquid spawn may have advantages for rapid mass production of spawn, and now, sawdust-cultivation by liquid spawn inoculation should be applied instead of sawdust spawn. Therefore, investigations were performed to evaluate the effect of sawdust-cultivation by liquid spawn inoculation. The results were as follows: 1. When 11 kinds of liquid media were applied, the oak-mushroom culture medium was the most excellent in growth. Most suitable temperature at PDA was $25^{\circ}C$, and $22.5\sim27.5^{\circ}C$ in range were optimal for liquid culture. In liquid culture, amount of mycelial growth increases rapidly up to 40 days of cultivation. Incubation at fermentor brought yield of 106mg dry mycelia per 40ml media after 17 days. 2. In 1l-spawn bottle, growth of mycelium by inoculation of 20ml-liquid spawns were faster than 6g-sawdust spawn in spread of mycelia. On 2kg-bag culture, inoculations of 10ml-, 20ml- and 30ml-liquid spawns were all slower than 20g-sawdust spawn in mycelial spread. So, amount increasement in ampunt of liquid spawn should be discussed. Yields of mushrooms until third sproutings of 2kg-bag culture were 580g in 30ml-liquid spawn inoculation, but 510g, 486g and 470g from 20g-sawdust spawn, 20ml-liquid spawn and 10ml-liquid spawn, respectively. Thus, 30ml-liquid spawn inoculation was highest in yield.

  • PDF