• Title/Summary/Keyword: 4M method

Search Result 11,369, Processing Time 0.042 seconds

Analysis of 12 chlorophenols in waste-water using automated liquid phase microextracion (LPME) device (자동화된 Liquid Phase Microextraction(LPME)를 이용한 폐수 중 12종의 클로로페놀 분석)

  • Kim, Seok-Jung;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.70-77
    • /
    • 2007
  • Twelve chlorophenols (CPs) were extracted by liquid phase microextraction (LPME) from the industrial waste-water and analyzed by GC/MS. To establish the optimal conditions, species of extraction solvent, sample amount, pH of sample, salting out effect, a number of sampling and plunger movement speed were investigated. As a result, the linearities of calibaration curves ranged from 0.9913 to 0.9999, while LODs and LOQs were from 0.05 to 10.0 ng/mL except 2,3,4,5-tetrachlorophenol and pentachlorophenol. Using this method, 4-chloro-3-methylphenol confirmed from waste water at the concentration of 784 ng/mL. The method can be applicable to detect chlorophenols from industrial waste-water.

Consolidation Behavior of Soft Ground by prefabricated Vertical Drains (연직드레인 공법에 의한 연약지반의 압밀거동)

  • 이달원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.5
    • /
    • pp.133-143
    • /
    • 2000
  • A large scale field test of prefabricated vertical drains was performed to anayze the effect of parameters of the very soft clay at a test site. compression index and the coefficient of horizontal consolidation obtained by back-analysis of settlement data were compared with those obtained by means of laboratory tests. Hyperbolic method, Asaoka meoth and curve fitting method were used to compute final settlement of coefficient of consolidation. The relationships of settlement measurement(Sm) versus design settlement(St) and the measurement consolidation ratio(Um) versus design consolidation (Ut) were shown as Sm=(1.0~1.1) St , Um=(1.13~1.17) Ut at 1.0m spacing of drain and Sm=(0.7~0.8)St, Um= (0.92~0.99) Ut at 1.5 m spacing of drain, respectively . The relationships of the field compression index(CcField) and virgin compression index(vcc lab) were shown as Ccfield =(1.0~1.2)vcc lab . But it was nearly within the same range when considering the error factor with the determination method of virgin compression index and the prediction back-analysis of the settlement data was larger than the coefficient of vertical consolidation, and the ratio of consolidation coefficient (Ch/Cv) was Ch =(2.4~2.9) Cv , Ch=(3.4~4.2) Cv at 1.0m and 1.5m spacing of drain, respectively.

  • PDF

A design and fabrication of asymmetric Y-branch optical power splitters by $Ag^+-Na^+$ ion exchange ($Ag^+-Na^+$ 이온교환법을 이용한 비대칭형 Y-분리기의 설계 및 제작)

  • 전금수;강동성;김희주;반재경
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.320-326
    • /
    • 2001
  • In this paper, we have fabricated asymmetric Y-branch optical power splitters with various optical power splitting ratios by changing the width of one of the output waveguides using $Ag^+-Na^+$ ion change method in BK7 glass. The transmission characteristics of asymmetric Y-branch optical power splitters with different output waveguide width have been investigated using the finitedifference beam propagation method (FD-BPM). We have found the index of the channel waveguide formed by Ag+-Na+ ion change method in BK7 glass and have fabricated channel waveguides to examine the transmission characteristics of channel waveguide. And we have fabricated asymmetric Y-branch optical power splitters with output waveguide width from TEX>$4{\mu}m$ to $6{\mu}m$. /TEX>.

  • PDF

Voltammetric Determination of Clenbuterol on Electrochemically Activated Glassy Carbon Electrode (전기 화학적으로 활성화된 glassy carbon 전극에서의 전압-전류 법을 이용한 Clenbuterol 측정)

  • Lee, Sohee;Piao, Yuanzhe
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.4
    • /
    • pp.216-221
    • /
    • 2014
  • A rapid and sensitive voltammetric method for the quantitative determination of Clenbuterol on electrochemically activated glassy carbon electrode has been developed. Using differential pulse voltammetry, the linear response range for the clenbuterol was between $1{\times}10^{-7}$ and $2{\times}10^{-5}M$, and the detection limit was $6{\times}10^{-9}M$ (S/N = 3). The relative standard derivation was 4.3% for $1{\times}10^{-6}M$ clenbuterol. Recoveries of 96% of the clenbuterol (n = 3) were obtained from urine spiked with different amounts in the ranges $5{\times}10^{-7}M$ and $1{\times}10^{-6}M$ by this method.

Determination of Aconitine and Related Alkaloids in Processed Buza (부자류 생약의 성분인 아코니틴과 관련 알칼로이드의 정량)

  • 엄동옥;한상욱;신현덕
    • YAKHAK HOEJI
    • /
    • v.44 no.2
    • /
    • pp.135-140
    • /
    • 2000
  • Determination of Aconitum alkaloids in processed Buza (Cho-0, Salted Buza, Moist-heating Buza, Limed Buza), which had been prepared from the raw tubers of Aconitum chiisanenseb(Ranunculaceae), was established using visible spectrophotometry and high-performance liquid chromatography (HPLC) method especially for Aconitine analysis. Aconitum alkloids were reacted with tetra- thiocy-anatocobalt[II] complex ion to form a stable ion pair. The reaction product was insoluble in water but freely soluble in several organic solvents. 1.2-Dichloroethane was the best extracting solvent among the examined solvents. Spectrophotometry of Aconitum alkaloids at nax. 625 was carried out. The HPLC method for aconitine was carried out using Radial PAK-CN column with gradient solvent system by solvent mixture of acetonitrile and phosphate buffer (pH 3.0) at 4$0^{\circ}C$ and 254 nm. Linear relationship was found between absorbance response and concentration of aconitine in range of 0.45 mM~0.9 mM ($r^2$=0.9949) by spectrophotometry and 0.3 mM~1.2mM($r^2$=0.9983) by HPLC method. These methods have been found to be suitable and reproducible for routine analysis of Aconitum alkaloids and its pharmaceutical preparations.

  • PDF

Effect of $MnO_2$ Additives on the Thermal Properties of Infrared Radiator of Cordierite System Fabricated by Slurry Casting Method (주입성형법으로 제조된 Cordierite계 적외선 방사체의 열적특성에 미치는 $MnO_2$의 영향)

  • 신용덕
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.7
    • /
    • pp.769-776
    • /
    • 1995
  • Infrared radiators of a cordierite system [cordierite (2MgO.2Al2O3.5SiO2)+30wt% clay+X wt% MnO2 (X=0, 0.1, 0.25, 0.5, 1.0, 1.5, 2.0, 2.5)] were manufactured by a slurry casting method. Thermal and physical properties of these infrared radiators were studied by the measurement of spectra emissivity, thermal expansion coefficient and apparent density, SEM and EPMA analyses were also carried out. The thermal expansion coefficient and apparent density were decreased with increasing amouonts of MnO2 additives. On the other hand, the spectral emissivity was increased in the wavelength below 4.5${\mu}{\textrm}{m}$. Also, infrared radiators of the cordierite system, of which the spectral emisivity was 0.8, could be attainable in the wavelength above 4.5${\mu}{\textrm}{m}$. The infrared radiator of the cordierite system with 2.0wt% MnO2, of which the spectral emissivity was approximately 1.0, could be attainable in the wavelength between 4.5${\mu}{\textrm}{m}$ and 8${\mu}{\textrm}{m}$. The spectral emissivity of the specimen containing 2.0wt% MnO2 was higher than others in the wavelength between 8${\mu}{\textrm}{m}$ and 14${\mu}{\textrm}{m}$.

  • PDF

Application of Variance Reduction Techniques in Designed Simulation Experiments (시뮬레이션 실험설계에서 분산감소기법의 응용)

  • 권치명
    • Journal of the Korea Society for Simulation
    • /
    • v.4 no.1
    • /
    • pp.25-36
    • /
    • 1995
  • We develop a variance reduction technique in one simulation experiment whose purpose is to estimate the parameters of a first-order linear model. This method utilizes the control variates obtained during the course of simulation run under Schruben and Margolin's method (S-M method). The performance of this method is shown to be similar in estimating the main effects, and to be superior to S-M method in estimating the overall mean response in the hospital simulation experiment. For the general case, we consider that a proposed method may yield a better result than S-M method if selected control variates are highly correlated with the response at each design point.

  • PDF

The Study on Natural Dyeability of Aloe Vera Extract (알로에 베라 추출물의 천연염색성에 관한 연구)

  • 박영득;김정화
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.4 no.1
    • /
    • pp.73-84
    • /
    • 2002
  • The purpose of this study was to investigate the natural dyeability on extract of Aloe Vera princeps. The experimental items were divided into the mordanting method, component of fabric, extracting portion, and kind of mordants. The experimental study was done to by laundering, abrasion(dry/wet), perspiration(acid/alkali), light fastness test and color difference by C.C.M system. The summerized finding resulted from experiments and investigation are suggested as follows: First, in the C.C.M test on mordanting method, color difference was significantly improved when mordants were treatmented. And the premordanting method showed the highest color difference. Second, in the C.C.M test on component of fabric, color difference of silk was higher than cotton. It was considered that silk has -$\NH_2$, -COOH, -OH more than cotton. Third, in the C.C.M Test on extracting portion, color difference of extracting in skin of Aloe leaf was three times higher than that of inside lump. Forth, in dyeing-fastness on mordants, laundering fastness showed 3 ~ 4 grade nearly. In perspiration-fastness(acid/alkali), Al(4~5/4~5) was the highest. In abrasion-fastness(dry/wet), cotton(4~5/4~5) was higher than silk (4~5/4) in all mordants. In light-fastness, silk(2~5) was higher than cotton(1~2) generally and especially Cu mordant of silk(4~5) was the highest. Sixth, in color difference analysis on 7 mordants Cu(29.9), Fe(28.7) and Cr(28.9) showed the highest in silk. And Cu(12.7), Fe(10.42) and Sn(10.43) showed the highest in cotton and Al(23.6, 8.0) showed the lowest in silk and cotton.

  • PDF

PAPR reduction algorithm of adaptive suboptimal PTS (PAPR 감소를 위한 임계치 적용 부최적 PTS 기법)

  • 권오주;하영호
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.609-612
    • /
    • 2001
  • An adaptive sub-optimal method using a preset threshold for combining partial transmit sequence (PTS) of an orthogonal frequency division multiplexing (OFDM) signal is presented. The results show that adaptive sub-optimal method reduces the 0.1% PAP by 3.4dB, while iterative flipping method reduces it by 3dB and PTS reduce it by 4.1dB. The complexity of adaptive sub-optimal method is 2.4% of that of PTS method for M=8.

  • PDF

Effect of thyroparathyroidectomy on urinary excretion of sodium, potassium, calcium and phosphate in the rabbits (갑상선 부갑상선 적출이 뇨중 Na, K, Ca 및 $PO_4$ 배설에 미치는 영향)

  • Choi, Duck-Kyung
    • The Korean Journal of Physiology
    • /
    • v.16 no.1
    • /
    • pp.69-76
    • /
    • 1982
  • The effect of parathyroid hormone on calcium and phosphate metabolism have been widely investigated, however less attention has been paid to the effect on urinary excretion. This study was performed for the purpose determining urinary excretion of Na, K, Ca, and $Po_4$, of 18 thyroparathyroidectomized (TPTX) rabbits, which were TPTX previously 7 to 10 days compared with the same normal ones. After TPTX 0.2 mg/day of synthyroid was donated to the rabbits. The concentration of electrolytes in the serum and urine was determined by the following method; Na and K were determined by means of flame photometry, Ca was by EDTA titration $method^{19)}$, and $Po_4$ by Fiske and Subba-Raw $method^{20)}$. The results as follows. The concentrations of electrolytes in the serum were 1) In the normal control rabbits (N = 25) (data, $Mean{\pm}S.E.$) $Na\;131.72{\pm}1.33\;mEq/L$, $K\;3.59{\pm}0.28\;mEq/L$, $Ca\;12.58{\pm}0.29\;mg%$, $Po_4\;4.50{\pm}\;0.45mg%$. 2) In the TPTX rabbits(N= 18) $Na\;140.6l{\pm}2.56\;mEq/L$, $K\;3.38{\pm}0.36\;mEq/L$, $Ca\;l2.18{\pm}0.45\;mg%$, $Po_4\;3.92{\pm}\;0.35\;mg%$. There was no significant change between the normal and TPTX rabbits. The concentration of elelctrolytes in the urine were variously changed. 3) In the normal rabbits. $Na\;8.40{\pm}1.09\;mEq/L$, $K\;81.59{\pm}10.19\;mEq/L$, $Ca\;16.02{\pm}3.12\;mg%$, $Po_4\;13.16{\pm}2.89mg%$. 4) In the TPTX rabbits, $Na\;14.57{\pm}3.39\;mEq/L$ slight ncreased, $K\;116.06{\pm}12.77\;mEq/L$ significant increased (P<0.05), $Ca\;18.90{\pm}5.44\;mg%$ no significant increased, $Po_4\;43.38{\pm}8.67\;mg%$ significant increased (p<0.01). The effect of TPTX was assumed that it affected upon increasing tubular secretion of $K^+$ and inhibition of the tubular reabsorption of $Po_4$.

  • PDF