• Title/Summary/Keyword: 4D-RT

Search Result 415, Processing Time 0.024 seconds

Development of a Virus Elution and Concentration Procedure for Detecting Norovirus in Oysters

  • Ha, Sook-Hee;Woo, Gun-Jo;Hwang, In-Gyun;Choi, Weon-Sang
    • Food Science and Biotechnology
    • /
    • v.18 no.5
    • /
    • pp.1150-1154
    • /
    • 2009
  • Low levels of virus contamination and naturally occurring reverse transcription-polymerase chain reaction (RT-PCR) inhibitors restrain virus detection in oysters. A rapid and efficient oyster-processing procedure that can be used for sensitive virus detection in oysters was developed. Poliovirus type 1 Sabin strain was used to evaluate the efficacy of virus recovery. The procedure included (a) acid-adsorption and elution with buffers (0.25M glycine-0.14 M NaCl, pH 7.5; 0.25M threonine-0.14M NaCl, pH 7.5); (b) polyethylene glycol (PEG) precipitation; (c) resuspension in Tween 80/Tris solution and chloroform extraction; (d) the second PEG precipitation; (e) viral RNA extraction with TRIzol and isopropanol precipitation; and (f) RT-PCR combined with semi-nested PCR. The overall recovery of elution/concentration was 19.5% with poliovirus. The whole procedure usually takes 19 hr. The overall detection sensitivity was 4 RT-PCR units of genogroup I norovirus (NoV) and 6.4 RT-PCR units of genogroup II Nov/25 g of oysters initially seeded. The virus-detecting method developed in this study should facilitate the detection of low levels of NoV in oysters.

Characteristics of the Mg and In co-doped ZnO Thin Films with Various Substrate Temperatures (RF 마그네트론 스퍼터를 이용하여 제작한 MIZO 박막의 특성에 미치는 기판 온도의 영향)

  • Jeon, Kiseok;Jee, Hongsub;Lim, Sangwoo;Jeong, Chaehwan
    • Current Photovoltaic Research
    • /
    • v.4 no.4
    • /
    • pp.150-154
    • /
    • 2016
  • Mg and In co-doped ZnO (MIZO) thin films with transparent conducting characteristics were successfully prepared on glass substrates by RF magnetron sputtering technique. The Influence of different substrate temperature (from RT to $400^{\circ}C$) on the structural, morphological, electrical, and optical properties of MIZO thin films were investigated. The MIZO thin film prepared at the substrate temperature of $350^{\circ}C$ showed the best electrical characteristics in terms of the carrier concentration ($4.24{\times}10^{20}cm^{-3}$), charge carrier mobility ($5.01cm^2V^{-1}S^{-1}$), and a minimum resistivity ($1.24{\times}10^{-4}{\Omega}{\cdot}cm$). The average transmission of MIZO thin films in the visible range was over 80% and the absorption edges of MIZO thin films were very sharp. The bandgap energy of MIZO thin films becomes wider from 3.44 eV to 3.6 eV as the substrate temperature increased from RT to $350^{\circ}C$. However, Band gap energy of MIZO thin film was narrow at substrate temperature of $400^{\circ}C$.

Activation and Abnormalities of Cell Cycle Regulating Factor in Head and Neck Squamous Cell Carcinoma Cell Lines: Abnormal Expression of CDKN2 Gene in Laryngeal Squamous Cell Carcinoma (두경부 편평상피세포암 세포주에서 세포주기조절인자의 활성 및 이상 : 후두편평상피세포암에서 종양억제유전자 CDKN2 유전자의 발현이상)

  • Song, Si-Youn;Han, Tae-Hee;Bai, Chang-Hoon;Kim, Yong-Dae;Song, Kei-Won
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.2
    • /
    • pp.166-182
    • /
    • 2005
  • Background: Cyclin-dependent kinase (CDK) inhibitors are family of molecules that regulate the cell cycle. The CDKN2, a CDK4 inhibitor, also called p16, has been implicated in human tumorigenesis. The CDKN2 inhibits the cyclin/CDK complexes which regulate the transition from G1 to S phase of cell cycle. There is a previous report that homozygous deletion of CDKN2 region on chromosome 9p21 was detected frequently in astrocytoma, glioma and osteosarcoma, less frequently in lung cancer, leukemia and ovarian cancer, but not detected in colon cancer and neuroblastoma. However, little is known about the relationship between CDKN2 and laryngeal cancer. Therefore this study was initiated to investigate the role of CDKN2 in human laryngeal squamous cell carcinoma development.1) Materials and methods: We used 5 human laryngeal carcinoma cell lines whether they have deletions or losses of CDKN2 gene expression by DNA-PCR or RT-PCR, respectively. We examined 8 fresh frozen human laryngeal cancer tissues to detect the loss of heterozygosity (LOH) of CDKN2. PCR was performed by using microsatellite markers of short arm of human chromosome 9 (D9S126, D9S144, D9S156, D9S161, D9S162, D9S166, D9S171, D9S200 and D9SIFNA). For informative cases, allelic loss was scored if the signal of one allele was significantly decreased in tumor DNA when compared to the same allele in normal DNA. Results: The CDKN2 DNA deletion was observed in 3 cell lines. The CDKN2 mRNA expression was observed in only one cell line, which was very weak. LOH was detected in 7 cases (87.5%). Conclusion: These results suggest that CDKN2 plays a role in the carcinogenesis of human laryngeal squamous cell carcinoma.

  • PDF

Studies on the VP4 and VP7 Genes of Bovine Rotaviruses from Field Samples Using RT-PCR and RFLP Analysis (RT-PCR과 RFLP법을 이용한 국내 소 로타바이러스 VP4 및 VP7 유전자의 특성 규명)

  • Jeon, Seong-Jin;Chang, Chung-Ho;Chung, Chung-Won;Kim, Won-Yong;Kang, Shien-Young
    • The Journal of Korean Society of Virology
    • /
    • v.28 no.2
    • /
    • pp.165-174
    • /
    • 1998
  • Characterizations of the VP4 (P type) and VP7 (G type) genes of Korean isolates of bovine rotavirus were performed using RT-PCR/RFLP and nucleotide sequencing analysis. After RT-PCR amplification of partial length (1094bp) of the VP4 and full length (1062bp) of the VP7 genes, amplified PCR products were digested with restriction endonucleases and digestion patterns were compared with those of reference rotaviruses. With the VP4 genes, four RFLP (A-D) profiles were observed; three (A, Band C) were the same as those of bovine rotavirus NCDV (P[1]), IND (P[5]) and B223 (P[11]), respectively. Profile D was the same as that of porcine rotavirus OSU (P[7]). With the VP7 genes, five RFLP profiles (I-V) were observed; three of them (I, II and III) were the same as those of bovine rotavirus NCDV (G6), Cody 1-801 (G8), and B223 (G10), respectively. Profile IV and V were atypical to those of reference bovine rotaviruses used in this study. These two profiles were identified as G6 and G5, respectively, after analyzing and comparing the nucleotide sequences. The G typing analysis revealed that 61.9% (26/42) were G6, which included G6 subtype; 28.6% (12/42) were G5; 7.1% (3/42) were G10; 2.4% (1/42) were G8. The P typing analysis revealed that 54.8% (23/42) were P[5]; 28.6% (12/42) were P[7]; 11.8% (5/42) were [11]; 4.8% (2/42) were P[1]. Our results showed that G6/P[5] were the most prevalent rotaviruses in diarrheic calves in Korea. Also, this is the first report that G5/P[7] rotaviruses were identified from cattle with diarrhea.

  • PDF

Molecular biological characterization of transmissible gastroenteritis viruses isolated in Korea (돼지 전염성 위장염 바이러스(국내분리주)의 분자생물학적 특성 규명)

  • Kwon, Hyuk-moo;Pi, Jae-ho
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.2
    • /
    • pp.304-313
    • /
    • 1998
  • Sixteen Korean field transmissible gastroenteritis viruses (TGEVs) were isolated using swine testicular cell (STC) and the genomic diversity of them was analyzed. All TGEV isolates produced a typical cytopathic effect in STC and were confirmed as TGEV by immunofluorescence assay using monoclonal antibody against TGEV and PCR using TGEV specific primers. RNAs from TGEV field isolates and vaccine TGEV were extracted and amplified by RT and PCR. The RT-PCR products were digested with selected restriction enzymes and analyzed RFLP patterns. The N-terminal end region of S gene and ORF 3 and 3-1 genes of TGEV amplified by TGEV specific primer pairs seemed to be conserved. Most specific variations were detected in S gene amplified by TGEV 4/6 primer pairs which includes antigenic sites A and D. When the PCR products were treated with Sau3AI and Ssp I, Bvac(vaccine strain), field isolates 133 and 347 were differentiated from Miller and Purdue types. In the case of D5 field isolates, it was classified into Purdue type by Sau 3AI but classified into independent TGEV by Ssp I. Two different TGEV strains from D2 sample were confirmed by plaque purification and RT-PCR-RFLP analysis. To investigate the change occurring in TGEV genome after serial passage, the TGEV P44 strain was passaged through STC. There were specific changes in S gene and a large deletion was observed in ORF 3 and 3-1 genes. These studies showed that a distinct difference in genome exists among TGEV field isolates.

  • PDF

Acoustic Properties of the Jeonju World Cup Stadium (전주월드컵 경기장의 음향특성 평가)

  • Yeon Chul-Ho;Haan Chan-Hoon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.495-500
    • /
    • 2002
  • 전주월드컵 경기장은 Fully Digital sidelobe-free array 방식의 음향시스템을 도입한 유일한 경기장으로서 대규모 경기장에 Line Array type의 스피커를 사용한 최초의 예가 된다. 현장음향실험을 통하여 경기장의 주요 음향 파라미터인 음압레벨(SPL), 잔향시간(RT), 음성명료도(D50), 음성이해도(RASTI) 등을 측정함으로 전주월드컵 경기장의 음향시스템의 특성과 종합적인 음향성능을 알아보고자 한다. 주음원(Messenger)만 사용하여 실험한 결과 음압레벨(SPL)은 관중석의 객석간 위치별 음압레벨 표준편차가 약 2.78dB로 나타났다. 이 값은 당초의 음압레벨분포편차의 목표치인 ${\pm}3dB$의 범위 이내로 나타났다. 또한 최대음압레벨은 평균 100.1dB로 목표치인 96dB을 초과하는 것으로 나타났다. 잔향시간(RT)은 공석시 전체 관중석 평균 2.94초로 나타났으며, 1000Hz에서의 평균 잔향시간은 2.58초로 나타났다. 잔향시간은 실제 경기장의 사용 시 약 0.3-0.4초의 감소가 발생되리라 판단된다. 음성명료도(D50)는 전체 관중석 평균 $56.2\%$로 매우 양호한 상태로 나타났고 음성이해도(RASTI)는 전체 관중석 평균 0.63으로 목표치인 0.5를 상회하는 것으로 나타났다. 이상의 현장음향실험 결과를 분석한 결과 전주월드컵 경기장의 음향성공은 음향설계 요건을 만족하는 것으로 나타났고 야외 경기장 같은 대형공간에서의 음향시스템에 있어서 Fully Digital sidelobe-free array 방식의 음향시스템의 적용가능성을 보여주고 있는 것으로 나타났다.

  • PDF

Frankfort horizontal plane is an appropriate three-dimensinal reference in the evaluation of clinical and skeletal cant

  • Oh, Suseok;Ahn, Jaemyung;Nam, Ki-Uk;Paeng, Jun-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.2
    • /
    • pp.71-76
    • /
    • 2013
  • Objectives: In three-dimensional computed tomography (3D-CT), the cant is evaluated by measuring the distance between the reference plane (or line) and the tooth. The purpose of this study was to determine the horizontal skeletal reference plane that showed the greatest correlation with clinical evaluation. Materials and Methods: The subjects were 15 patients who closed their eyes during the CT image taking process. The menton points of all patients deviated by more than 3 mm. In the first evaluation, clinical cant was measured. The distance from the inner canthus to the ipsilateral canine tip and the distance from the eyelid to the ipsilateral first molar were obtained. The distance between the left and right sides was also measured. In the second evaluation, skeletal cant was measured. Six reference planes and one line were used for the evaluation of occlusal cant: 1) FH plane R: Or.R - Or.L - Po.R; 2) FH plane L: Or.R - Or.L - Po.L; 3) F. Ovale plane R: Rt.F.Ovale - Lt.F.Ovale - Or.R; 4) F. Ovale plane L: Rt.F.Ovale - Lt.F.Ovale - Or.L; 5) FZS plane R: Rt.FZS - Lt.FZS - Po.R; 6) FZS plane R: Rt.FZS - Lt.FZS - Po.L, and; 7) FZS line: Rt.FZS - Lt.FZS. Results: The clinical and skeletal cants were compared using linear regression analysis. The FH plane R, FH plane L, and FZS line showed the highest correlation (P<0.05). Conclusion: The FH plane R and FH plane L are the most appropriate horizontal reference plane in evaluation of occlusal cant on 3D-CT.

Effects of Vitamin E Derivative TMG on the Radiation Protector and Tumor Growth during Radiotherapy

  • Yeun-Hwa Gu;Ryo Matsumoto;Takenori Yamashita
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • Background: The purpose of this study is to evaluate the immunosuppressive and antioxidant effects of a novel radioprotective agent using the vitamin E derivative 2-(alpha-D-glucopyranosyl)methyl-2,5,7,8-tetramethylchroman-6-ol (TMG) and its effect on tumors, and to study its usefulness. Materials and Methods: In this study, C57BL/6NCrSlc mice were divided into four groups (control, TMG, radiation therapy [RT], and RT+TMG), using 10 mice in each group. In the TMG and 2 Gy+TMG groups, 500 mg/kg TMG was administered. Two groups (2 Gy and 2 Gy+TMG) among RT and RT+TMG groups were irradiated with 2 Gy in a single fraction, while the other two groups (6 Gy and 6 Gy+TMG) were irradiated locally with 6 Gy in three fractions. Results and Discussion: TMG positively affected CD4+ and CD8+ T lymphocytes. Tumor volumes and growth inhibition rates were compared. In order to evaluate how TMG administration affected tumor growth, Ehrlich cancer cells were injected into the thigh of mice, and the tumor volume and growth suppression rate were compared. Not only RT but also TMG alone inhibited tumor growth. If RT conducted to the mice with TMG, TMG could increase the number of leukocytes, primarily that of lymphocytes. TMG also inhibited tumor growth in addition to RT. Tumor growth was significantly inhibited in the 6 Gy+TMG group. Conclusion: In conclusion, TMG exerted an immunopotentiating effect mainly by increasing the white blood cell numbers including that of lymphocytes. In addition to RT, TMG also inhibited tumor growth. Therefore, TMG is considered to be a useful radioprotective agent in radiotherapy without tumor growth induction.

Indoor Scene Classification based on Color and Depth Images for Automated Reverberation Sound Editing (자동 잔향 편집을 위한 컬러 및 깊이 정보 기반 실내 장면 분류)

  • Jeong, Min-Heuk;Yu, Yong-Hyun;Park, Sung-Jun;Hwang, Seung-Jun;Baek, Joong-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.3
    • /
    • pp.384-390
    • /
    • 2020
  • The reverberation effect on the sound when producing movies or VR contents is a very important factor in the realism and liveliness. The reverberation time depending the space is recommended in a standard called RT60(Reverberation Time 60 dB). In this paper, we propose a scene recognition technique for automatic reverberation editing. To this end, we devised a classification model that independently trains color images and predicted depth images in the same model. Indoor scene classification is limited only by training color information because of the similarity of internal structure. Deep learning based depth information extraction technology is used to use spatial depth information. Based on RT60, 10 scene classes were constructed and model training and evaluation were conducted. Finally, the proposed SCR + DNet (Scene Classification for Reverb + Depth Net) classifier achieves higher performance than conventional CNN classifiers with 92.4% accuracy.

Usefulness evaluation of Hybrid planning through dosimetric comparision of Three Dimensinal Conformal Radiation Radiotherapy and Hybrid planning for left breast cancer (유방암 환자의 방사선 치료시 Energy와 Wedge를 combine한 Hybrid plan의 유용성 평가)

  • Chae, Moon Ki;Park, Byung Soo;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.91-98
    • /
    • 2014
  • Purpose : To compare the dosimetry for the left breast cancer treatment between three dimensional conformal radiation radiotherapy (3D-CRT) and Hybrid planning and to estimate usefulness of Hybrid planning Materials and Methods : Five patients with left breast cancer were included in the study. They were planned using several different radiotherapy techniques including: 1)open rectangular field, 2)tangential wedge-based field 3)field in field, 4)hybrid planning(energy, wedge combine). For each patient planning was using Light Speed RT-16 CT and PINNACLE planning system-ver.9.2. Hybrid plan was made using same system and using the same targets and optimization goals. We comparing the Homogeneity Index(HI), normal organs at the does-volume histogram(DVH) Results : In all plans, the Homogeneity Index(HI) of Hybrid planning was significantly better than other. Dose comparison of HI= 2D-RT:38.32, TW:38.32, FIF:29.22, HYBRID:30.57. 2D-RT, TW, FIF Hybrid$V_{75_-lung}$=112.33, 125.14, 121.3, 123.78. $V_{50_-lung}$=155.43, 159.62, 157.96, 159.06. $V_{25_-lung}$=199.86, 200.22, 198.65, 200.31. $V_{50_-heart}$=26.07, 27.1, 26.85, 27.17 $V_{30_-heart}$=33.71, 34.37, 34.15, 34.65 Conclusion : In summary, 3D-CRT, Hybrid planning techniques were found to have acceptableCTV coverage in our study. However the Hybrid planning increased radiation dose exposure to normal tissue. If you apply for treatment of inhomogeneity areas like lung, For best results will be achieved.