• Title/Summary/Keyword: 4D radiotherapy

Search Result 219, Processing Time 0.025 seconds

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF

Serum 25-hydroxy Vitamin D Status is Not Related to Osteopenia/Osteoporosis Risk in Colorectal Cancer Survivors

  • Akinci, Muhammed Bulent;Sendur, Mehmet Ali Nahit;Aksoy, Sercan;Yazici, Ozan;Ozdemir, Nuriye Yildirim;Kos, Tugba;Yaman, Sebnem;Altundag, Kadri;Zengin, Nurullah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3377-3381
    • /
    • 2014
  • Background: The incidence of colorectal cancer increases with vitamin D deficiency as shown in recently published studies. In addition, prospective investigations have indicated that low vitamin D levels may be associated with increased mortality of colorectal cancer, especially in stage III and IV cases. However, the exact incidence of vitamin D deficiency and the relation between vitamin D deficiency and osteopenia/osteporosis is still not known. The aim of this study is to identify severity of vitamin D deficiency and absolute risk factors of osteopenia/osteoporosis in colorectal cancer survivors. Materials and Methods: A total of 113 colorectal cancer survivors treated with surgery and/or chemotherapy ${\pm}$ radiotherapy were recruited from medical oncology outpatient clinics during routine follow-up visits in 2012-2013. Bone mineral densitometry (BMD) was performed, and serum 25-OH vitamin D levels were also checked on the same day of the questionnaire. The patients was divided into 2 groups, group A with normal BMD and group B with osteopenia/osteoporosis. Results: The median age of the study population was 58 (40-76). Thirty (30.0%) were female, whereas 79 (70.0%) were male. The median follow-up was 48 months (14-120 months). Vitamin D deficiency was found in 109 (96.5%); mild deficiency (20-30 ng/ml) in 19 (16.8%), moderate deficiency (10-20 ng/ml) in 54 (47.8%) and severe deficiency (<10 ng/ml) in 36 (31.9%). Osteopenia was evident in 58 (51.4%) patients whereas osteoporosis was noted in 17 (15.0%). Normal BMD was observed in 38 (33.6%). No apparent effects of type of surgery, presence of stoma, chemotherapy, radiotherapy and TNM stage were found regarding the risk of osteopenia and osteoporosis. Also, the severity of the vitamin D deficiency had no effect in the risk of osteopenia and osteporosis (p=0.93). In female patients, osteopenia/osteoporosis were observed in 79.5% patients as compared to 60.7% of male patients (p=0.04). Conclusions: In our study, vitamin D deficiency and osteopenia/osteoporosis was observed in 96.5% and 66.4% of colorectal cancer survivors, respectively. There is no defined absolute risk factor of osteopenia and osteoporosis in colorectal cancer survivors. To our knowledge, in the literature, our study is the first to evaluateall the risk factors of osteopenia and osteoporosis in colorectal cancer survivors.

Reproducibility evaluation of the use of pressure conserving abdominal compressor in lung and liver volumetric modulated arc therapy (흉복부 방사선 치료 시 압력 기반 복부압박장치 적용에 따른 치료 간 재현성 평가)

  • Park, ga yeon;Kim, joo ho;Shin, hyun kyung;Kim, min soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose: To evaluate the inter-fractional position and respiratory reproducibility of lung and liver tumors using pressure conserving type(P-type) abdominal compressor in volumetric modulated arc therapy(VMAT). Materials and methods: Six lung cancer patients and three liver cancer patients who underwent VMAT using a P-type abdominal compressor were included in this study. Cone-beam computed tomography(CBCT) images were acquired before each treatment and compared with planning CT images to evaluate the inter-fractional position reproducibility. The position variation was defined as the difference of position shift values between target matching and bone matching. 4-dimensional cone-beam computed tomography(4D CBCT) images were acquired weekly before treatment and compared with planning 4DCT images to evaluate the inter-fractional respiratory reproducibility. The respiratory variation was calculated by the magnitude of excursions by breathing. Results: The mean ± standard deviation(SD) of overall position variation values, 3D vector in the three translational directions were 1.1 ± 1.4 mm and 4.5 ± 2.8 mm for the lung and liver, respectively. The mean ± SD of respiratory variation values were 0.7 ± 3.4 mm (p = 0.195) in the lung and 3.6 ± 2.6 mm (p < 0.05) in the liver. Conclusion: The use of P-type compressor in lung and liver VMAT was effective for stable control of inter-fractional position and respiratory variation by reproduction of abdominal compression. Appropriate PTV margin must be considered in treatment planning, and image guidance before each treatment are required in order to obtain more stable reproducibility

Association of tumor differentiation grade and survival of women with squamous cell carcinoma of the uterine cervix

  • Matsuo, Koji;Mandelbaum, Rachel S.;Machida, Hiroko;Purushotham, Sanjay;Grubbs, Brendan H.;Roman, Lynda D.;Wright, Jason D.
    • Journal of Gynecologic Oncology
    • /
    • v.29 no.6
    • /
    • pp.91.1-91.12
    • /
    • 2018
  • Objective: To examine the association between tumor grade and survival for women with squamous cervical cancer. Methods: This retrospective observational study utilized the Surveillance, Epidemiology, and End Result program data between 1983 and 2013 to examine women with squamous cervical cancer with known tumor differentiation grade. Multivariable analyses were performed to assess independent associations between tumor differentiation grade and survival. Results: A total of 31,536 women were identified including 15,175 (48.1%) with grade 3 tumors, 14,084 (44.7%) with grade 2 neoplasms and 2,277 (7.2%) with grade 1 tumors. Higher tumor grade was significantly associated with older age, higher stage disease, larger tumor size, and lymph node metastasis (all, p<0.001). In a multivariable analysis, grade 2 tumors (adjusted-hazard ratio [HR]=1.21; p<0.001) and grade 3 tumors (adjusted-HR=1.45; p<0.001) were independently associated with decreased cause-specific survival (CSS) compared to grade 1 tumors. Among the 7,429 women with stage II-III disease who received radiotherapy without surgical treatment, grade 3 tumors were independently associated with decreased CSS compared to grade 2 tumors (adjusted-HR=1.16; p<0.001). Among 4,045 women with node-negative stage I disease and tumor size ${\leq}4cm$ who underwent surgical treatment without radiotherapy, grade 2 tumors (adjusted-HR=2.54; p=0.028) and grade 3 tumors (adjusted-HR=4.48; p<0.001) were independently associated with decreased CSS compared to grade 1 tumors. Conclusion: Our study suggests that tumor differentiation grade may be a prognostic factor in women with squamous cervical cancer, particularly in early-stage disease. Higher tumor grade was associated with poorer survival.

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

Comparison of Two Different Immobilization Devices for Pelvic Region Radiotherapy in Tomotherapy

  • Kim, Dae Gun;Jung, James J;Cho, Kwang Hwan;Ryu, Mi Ryeong;Moon, Seong Kwon;Bae, Sun Hyun;Ahn, Jae Ouk;Jung, Jae Hong
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.250-257
    • /
    • 2016
  • The purpose of this study was to compare the patient setup errors of two different immobilization devices (Feet Fix: FF and Leg Fix: LF) for pelvic region radiotherapy in Tomotherapy. Thirty six-patients previously treated with IMRT technique were selected, and divided into two groups based on applied immobilization devices (FF versus LF). We performed a retrospective clinical analysis including the mean, systematic, random variation, 3D-error, and calculated the planning target volume (PTV) margin. In addition, a rotational error (angles, $^{\circ}$) for each patient was analyzed using the automatic image registration. The 3D-errors for the FF and the LF groups were 3.70 mm and 4.26 mm, respectively; the LF group value was 15.1% higher than in the FF group. The treatment margin in the ML, SI, and AP directions were 5.23 mm (6.08 mm), 4.64 mm (6.29 mm), 5.83 mm (8.69 mm) in the FF group (and the LF group), respectively, that the FF group was lower than in the LF group. The percentage in treatment fractions for the FF group (ant the LF group) in greater than 5 mm at ML, SI, and AP direction was 1.7% (3.6%), 3.3% (10.7%), and 5.0% (16.1%), respectively. Two different immobilization devices were affected the patient setup errors due to different fixed location in low extremity. The radiotherapy for the pelvic region by Tomotherapy should be considering variation for the rotational angles including Yaw and Pitch direction that incorrect setup error during the treatment. In addition the choice of an appropriate immobilization device is important because an unalterable rotation angle affects the setup error.

Dosimetric Analysis of Lung Stereotactic Body Radiotherapy Using Halcyon Linear Accelerator

  • Shinhaeng Cho;Ick Joon Cho;Yong Hyub Kim;Jea-Uk Jeong;Mee Sun Yoon;Taek-Keun Nam;Sung-Ja Ahn;Ju-Young Song
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.48-54
    • /
    • 2023
  • Purpose: In this study, the dosimetric characteristics of lung stereotactic body radiotherapy (SBRT) plans using the new Halcyon system were analyzed to assess its suitability. Methods: We compared the key dosimetric parameters calculated for the Halcyon SBRT plans with those of a conventional C-arm linear accelerator (LINAC) equipped with a high-definition multileaf collimator (HD-MLC)-Trilogy Tx. A total of 10 patients with non-small-cell lung cancer were selected, and all SBRT plans were generated using the RapidArc technique. Results: Trilogy Tx exhibited significant superiority over Halcyon in terms of target dose coverage (conformity index, homogeneity index, D0.1 cc, and D95%) and dose spillage (gradient). Trilogy Tx was more efficient than Halcyon in the lung SBRT beam delivery process in terms of the total number of monitor units, modulation factor, and beam-on time. However, it was feasible to achieve a dose distribution that met SBRT plan requirements using Halcyon, with no significant differences in satisfying organs at risk dose constraints between both plans. Conclusions: Results confirm that Halcyon is a viable alternative for performing lung SBRT in the absence of a LINAC equipped with HD-MLC. However, extra consideration should be taken in determining whether to use Halcyon when the planning target volume setting is enormous, as in the case of significant tumor motions.

Gold nanoparticles enhance anti-tumor effect of radiotherapy to hypoxic tumor

  • Kim, Mi Sun;Lee, Eun-Jung;Kim, Jae-Won;Chung, Ui Seok;Koh, Won-Gun;Keum, Ki Chang;Koom, Woong Sub
    • Radiation Oncology Journal
    • /
    • v.34 no.3
    • /
    • pp.230-238
    • /
    • 2016
  • Purpose: Hypoxia can impair the therapeutic efficacy of radiotherapy (RT). Therefore, a new strategy is necessary for enhancing the response to RT. In this study, we investigated whether the combination of nanoparticles and RT is effective in eliminating the radioresistance of hypoxic tumors. Materials and Methods: Gold nanoparticles (GNPs) consisting of a silica core with a gold shell were used. CT26 colon cancer mouse model was developed to study whether the combination of RT and GNPs reduced hypoxia-induced radioresistance. Hypoxia inducible $factor-1{\alpha}$ ($HIF-1{\alpha}$) was used as a hypoxia marker. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining were conducted to evaluate cell death. Results: Hypoxic tumor cells had an impaired response to RT. GNPs combined with RT enhanced anti-tumor effect in hypoxic tumor compared with RT alone. The combination of GNPs and RT decreased tumor cell viability compare to RT alone in vitro. Under hypoxia, tumors treated with GNPs + RT showed a higher response than that shown by tumors treated with RT alone. When a reactive oxygen species (ROS) scavenger was added, the enhanced antitumor effect of GNPs + RT was diminished. Conclusion: In the present study, hypoxic tumors treated with GNPs + RT showed favorable responses, which might be attributable to the ROS production induced by GNPs + RT. Taken together, GNPs combined with RT seems to be potential modality for enhancing the response to RT in hypoxic tumors.

Vitamin D Levels in Patients with Breast Cancer: Importance of Dressing Style

  • Alco, Gul;Igdem, Sefik;Dincer, Maktav;Ozmen, Vahit;Saglam, Sezer;Selamoglu, Derya;Erdogan, Zeynep;Ordu, Cetin;Pilanci, Kezban Nur;Bozdogan, Atilla;Yenice, Sedef;Tecimer, Coskun;Demir, Gokhan;Koksal, Gulistan;Okkan, Sait
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.3
    • /
    • pp.1357-1362
    • /
    • 2014
  • Background: Vitamin D deficiency is a potentially modifiable risk factor that may be targeted for breast cancer (BC) prevention. It may also be related to prognosis after diagnosis and treatment. The aim of our study was to determine the prevalence of vitamin D deficiency as measured by serum 25-hydroxy vitamin D (25-OHD) levels in patients with BC and to evaluate its correlations with life-style and treatments. Materials and Methods: This study included 186 patients with stage 0-III BC treated in our breast center between 2010-2013. The correlation between serum baseline 25-OHD levels and supplement usage, age, menopausal status, diabetes mellitus, usage of bisphosphonates, body-mass index (BMI), season, dressing style, administration of systemic treatments and radiotherapy were investigated. The distribution of serum 25-OHD levels was categorized as deficient (<10ng/ml), insufficient (10-24 ng/ml), and sufficient (25-80 ng/ml). Results: The median age of the patients was 51 years (range: 27-79 years) and 70% of them had deficient/insufficient 25-OHD levels. On univariate analysis, vitamin D deficiency/insufficiency was more common in patients with none or low dose vitamin D supplementation at the baseline, high BMI (${\geq}25$), no bisphosphonate usage, and a conservative dressing style. On multivariate analysis, none or low dose vitamin D supplementation, and decreased sun-exposure due to a conservative dressing style were found as independent factors increasing risk of vitamin D deficiency/insufficiency 28.7 (p=0.002) and 13.4 (p=0.003) fold, respectively. Conclusions: The prevalence of serum 25-OHD deficiency/insufficiency is high in our BC survivors. Vitamin D status should be routinely evaluated for all women, especially those with a conservative dressing style, as part of regular preventive care, and they should take supplemental vitamin D.

Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization (자체 제작한 정위적체부방사선치료(Stereotactic Body Radiotherapy) 고정용구의 유용성 평가)

  • Lee, Dong-Hoon;Ahn, Jong-Ho;Seo, Jeong-Min;Shin, Eun-Hyeok;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Materials and Methods: Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. Results: The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. Conclusion: The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations. Particularly in case of the stereotactic body therapy which requires the maintenance of set-up state for a long time, the self-developed immobilizations is thought to more useful for stereotactic body radiotherapy rather than the rest two immobilizations with instable respiratory cycle as time passes.

  • PDF