• Title/Summary/Keyword: 4D Reconstruction

Search Result 338, Processing Time 0.027 seconds

Spare parts neoumbilicoplasty

  • Tobler, William D. Jr;Nicholas, Kelly N.;Cruz, Carolyn De La
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.371-374
    • /
    • 2019
  • Umbilical preservation can be challenging, particularly in complex cases involving simultaneous ventral hernia repair and abdominoplasty. Although the umbilicus serves no functional purpose, removal of the umbilicus can draw unwanted attention to the abdominal area and can cause emotional distress to patients. There are several well documented options for umbilical reconstruction. We present a new umbilical reconstruction technique relevant for such cases. This neoumbilicoplasty allows for preservation of the original umbilicus with relocation and reconstruction using local flaps. The technique is relatively simple and the time needed is minimal. The result is a natural, well positioned umbilicus using the principles of spare part surgery.

A review of the total correction of tetralogy of Fallot (Fallot 4징증의 근치수술에 대한 임상적 고찰)

  • 채성수
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.337-341
    • /
    • 1983
  • The experience with operative treatment for total correction of Tetralogy of Fallot at the department of Thoracic and Cardiovascular Surgery, Korea University Hospital from January, 1977, through April, 1983 was reviewed. Of the 29 patients reviewed, male to female occurrence ratio was 22:7 Type of V.S.D. was type II in 26 cases[90%] and total conus defect in 3 cases[10%]. Average size of V.S.D. was 19 mm. Type of Right ventricular outflow tract stenosis was highest frequency with pulmonary valvular and infundibular stenosis combined type in 21 cases[72%], and there were 8 deaths In this group. Type of R.V.O.T. reconstruction contains 2 cases of infundibulectomy only, 1 case of infundibulectomy with valvular commissurotomy, 2 cases of pericardial patch, 23 Cases of pericardial patch with Teflon or Dacron felt reinforced and 1 case of pulmonary valved conduit reconstruction. Operative mortality was higher in outflow patch through pulmonary valve ring. Overall mortality was 31%. Major causes of death and postoperative complications were low output syndrome, complete A-V block acute renal failure, ventricular fibrillation, bleeding brain abscess, and sudden cardiac arrest.

  • PDF

A cosmic ray muons tomography system with triangular bar plastic scintillator detectors and improved 3D image reconstruction algorithm: A simulation study

  • Yanwei Zhao;Xujia Luo;Kemian Qin;Guorui Liu;Daiyuan Chen;R.S. Augusto;Weixiong Zhang;Xiaogang Luo;Chunxian Liu;Juntao Liu;Zhiyi Liu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.681-689
    • /
    • 2023
  • Purpose: Muons are characterized by a strong penetrating ability and can travel through thousands of meters of rock, making them ideal to image large volumes and substances typically impenetrable to, for example, electrons and photons. The feasibility of 3D image reconstruction and material identification based on a cosmic ray muons tomography (MT) system with triangular bar plastic scintillator detectors has been verified in this paper. Our prototype shows potential application value and the authors wish to apply this prototype system to 3D imaging. In addition, an MT experiment with the same detector system is also in progress. Methods: A simulation based on GEANT4 was developed to study cosmic ray muons' physical processes and motion trails. The yield and transportation of optical photons scintillated in each triangular bar of the detector system were reproduced. An image reconstruction algorithm and correction method based on muon scattering, which differs from the conventional PoCA algorithm, has been developed based on simulation data and verified by experimental data. Results: According to the simulation result, the detector system's position resolution is below 1 ~ mm in simulation and 2 mm in the experiment. A relatively legible 3D image of lead bricks in size of 20 cm × 5 cm × 10 cm used our inversion algorithm can be presented below 1× 104 effective events, which takes 16 h of acquisition time experimentally. Conclusion: The proposed method is a potential candidate to monitor the cosmic ray MT accurately. Monte Carlo simulations have been performed to discuss the application of the detector and the simulation results have indicated that the detector can be used in cosmic ray MT. The cosmic ray MT experiment is currently underway. Furthermore, the proposal also has the potential to scan the earth, buildings, and other structures of interest including for instance computerized imaging in an archaeological framework.

The Evaluation of Reconstructed Images in 3D OSEM According to Iteration and Subset Number (3D OSEM 재구성 법에서 반복연산(Iteration) 횟수와 부분집합(Subset) 개수 변경에 따른 영상의 질 평가)

  • Kim, Dong-Seok;Kim, Seong-Hwan;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • Purpose: Presently in the nuclear medicine field, the high-speed image reconstruction algorithm like the OSEM algorithm is widely used as the alternative of the filtered back projection method due to the rapid development and application of the digital computer. There is no to relate and if it applies the optimal parameter be clearly determined. In this research, the quality change of the Jaszczak phantom experiment and brain SPECT patient data according to the iteration times and subset number change try to be been put through and analyzed in 3D OSEM reconstruction method of applying 3D beam modeling. Materials and Methods: Patient data from August, 2010 studied and analyzed against 5 patients implementing the brain SPECT until september, 2010 in the nuclear medicine department of ASAN medical center. The phantom image used the mixed Jaszczak phantom equally and obtained the water and 99mTc (500 MBq) in the dual head gamma camera Symbia T2 of Siemens. When reconstructing each image altogether with patient data and phantom data, we changed iteration number as 1, 4, 8, 12, 24 and 30 times and subset number as 2, 4, 8, 16 and 32 times. We reconstructed in reconstructed each image, the variation coefficient for guessing about noise of images and image contrast, FWHM were produced and compared. Results: In patients and phantom experiment data, a contrast and spatial resolution of an image showed the tendency to increase linearly altogether according to the increment of the iteration times and subset number but the variation coefficient did not show the tendency to be improved according to the increase of two parameters. In the comparison according to the scan time, the image contrast and FWHM showed altogether the result of being linearly improved according to the iteration times and subset number increase in projection per 10, 20 and 30 second image but the variation coefficient did not show the tendency to be improved. Conclusion: The linear relationship of the image contrast improved in 3D OSEM reconstruction method image of applying 3D beam modeling through this experiment like the existing 1D and 2D OSEM reconfiguration method according to the iteration times and subset number increase could be confirmed. However, this is simple phantom experiment and the result of obtaining by the some patients limited range and the various variables can be existed. So for generalizing this based on this results of this experiment, there is the excessiveness and the evaluation about 3D OSEM reconfiguration method should be additionally made through experiments after this.

  • PDF

A Glance of Electron Tomography through 4th International Congress on Electron Tomography (International Congress on Electron Tomography에 대한 간략한 이해와 현황)

  • Rhyu, Im-Joo;Park, Seung-Nam
    • Applied Microscopy
    • /
    • v.38 no.3
    • /
    • pp.275-278
    • /
    • 2008
  • Electron tomography (ET) is an electron microscopic technique for obtaining a 3-D image from any electron microscopy specimen and its application in biomedical science has been increased thanks to development of electron microscopy and related technologies during the last decade. There are few researches on ET in Korea during this period. Although the importance of ET has been recognized recently by many researchers, initial approach to electron tomographic research is not easy for beginners. The 4th International Congress on Electron Tomography (4 ICET) was held on Nov $5{\sim}8$, 2006, at San Diego. The program dealt instrumentation, reconstruction algorithm, visualization/quantitative analysis and electron tomographic presentation of biological specimen and nano particles. 1 have summarized oral presentations and analyzed the posters presented on the meeting. Cryo-electron microscopic system was popular system for ET and followed conventional transmission electron microscopic system. Cultured cell line and tissue were most popular specimens analyzed and microorganisms including bacteria and virus also constituted important specimens. This analysis provides a current state of art in ET research and a guide line for practical application of ET and further research strategies.

The Anatomical Variations of DIEA (Deep Inferior Epigastric Artery) in Microsurgical Breast Reconstruction: Clinical Report (미세유방재건술시 깊은 아래 배벽 동맥의 해부학적 변형에 대한 임상 보고)

  • Jang, Seo-Yoon;Kim, Deok-Woo;Dhong, Eun-Sang;Yoon, Eul-Sik;Ryu, Woo-Sang;Son, Gil-Soo
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.14-17
    • /
    • 2011
  • Autologous breast reconstruction after mastectomy in breast cancer patient is now increasing. The deep inferior epigastric artery (DIEA) free flap is well known as an ideal donor site for the microsurgical breast reconstruction. The branching pattern of the DIEA was well described in the literature. In that study, DIEA has three branching patterns near the arcuate line. We describe a case in which branching variation of the DIEA before entering the posterior surface of the rectus abdominis muscle. In three cases, DIEA originated from the external iliac artery ascended as a double trunk at 1cm, 2cm, and 4cm above the originating point, respectively. In one case, DIEA ascended as a single trunk along the linea alba toward to the umbilicus until it supply overlying subcutaneous tissue. Preoperative 3D computed tomographic angiography to identify the anomaly is recommended and meticulous dissection to the originating point of DIEA is needed.

  • PDF

Comparision of the Muscle Activity and Balance of Lower Extremities in Exercise Using TOGU on the Unstable Surface and Stable Surface after Reconstruction of the ACL (앞십자인대 재건술 후 토구를 이용한 불안정한 표면에서 운동과 안정된 표면에서 운동 시 하지 근활성도와 균형의 비교)

  • Lim, Chang-Hun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.3
    • /
    • pp.251-258
    • /
    • 2012
  • Purpose : The purpose of this study is to provide an efficient and basis for muscle activity of Quadriceps muscles and balance in anterior cruciate ligament reconstruction patients through unstable surface exercise and stable surface exercise. Methods : This study included 30 anterior cruciate ligament reconstruction patients belonging to A hospital and D orthopedic surgery clinic of province who attended the program for 30 minutes at a time and three times a week for 4 weeks. Of these 15 attended the unstable surface exercise program and 15 the stable surface exercise program. To increase muscle activity (%MVIC) and balance (WPL), the unstable surface exercise. Results : The %MVIC of lower extrmity muscle(RF, VL, VM) increased from before training to after training in the case of the participants who performed the unstable surface exercise, and the whole path length (WPL) decreased from before the training to after the training(p<.05). Conclusion : In conclusion, unstable surface exercise program helps to improve the balancing ability and musle activity in a anterior cruciate ligament recunstruction patients who requires both muscle activity and balance than stable surface exercise program.

Customized 3D Printed Bolus for Breast Reconstruction for Modified Radical Mastectomy (MRM)

  • Ha, Jin-Suk;Jung, Jae Hong;Kim, Min-Joo;Jeon, Mi Jin;Jang, Won Suk;Cho, Yoon Jin;Lee, Ik Jae;Kim, Jun Won;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.196-202
    • /
    • 2016
  • We aim to develop the breast bolus by using a 3D printer to minimize the air-gap, and compare it to commercial bolus used for patients undergoing reconstruction in breast cancer. The bolus-shaped region of interests (ROIs) were contoured at the surface of the intensity-modulated radiation therapy (IMRT) thorax phantom with 5 mm thickness, after which the digital imaging and communications in mdicine (DICOM)-RT structure file was acquired. The intensity-modulated radiation therapy (Tomo-IMRT) and direct mode (Tomo-Direct) using the Tomotherapy were established. The 13 point doses were measured by optically stimulated luminescence (OSLD) dosimetry. The measurement data was analyzed to quantitatively evaluate the applicability of 3D bolus. The percentage change of mean measured dose between the commercial bolus and 3D-bolus was 2.3% and 0.7% for the Tomo-direct and Tomo-IMRT, respectively. For air-gap, range of the commercial bolus was from 0.8 cm to 1.5 cm at the periphery of the right breast. In contrast, the 3D-bolus have occurred the air-gap (i.e., 0 cm). The 3D-bolus for radiation therapy reduces the air-gap on irregular body surface that believed to help in accurate and precise radiation therapy due to better property of adhesion.

Representation Techniques for 4-Dimensional MR Images

  • Homma, Kazuhiro;Takenaka, Kenji;Nakai, Yoshihiko;Hirose, Takeshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.429-431
    • /
    • 2002
  • Metabolic analysis of biological tissues, the interventional radiology in MRT (Magnetic Resonance Treatment) and for clinical diagnoses, representation of 4-Dimensional (4D) structural information (x,y,z,t) of biological tissues is required. This paper discusses image representation techniques for those 4D MR Images. We have proposed an image reconstruction method for ultra-fast 3D MRI. It is based on image interpolation and prediction of un-acquired pictorial data in both of the real and the k-space (the acquisition domain in MRI). A 4D MR image is reconstructed from only two 3D MR images and acquired a few echo signals that are optimized by prediction of the tissue motion. This prediction can be done by the phase of acquired echo signal is proportioned to the tissue motion. On the other hand, reconstructed 4D MR images are represented as a 3D-movie by using computer graphics techniques. Rendered tissue surfaces and/or ROIs are displayed on a CRT monitor. It is represented in an arbitrary plane and/or rendered surface with their motion. As examples of the proposed representation techniques, the finger and the lung motion of healthy volunteers are demonstrated.

  • PDF

An Efficient Real-Time Image Reconstruction Scheme using Network m Multiple View and Multiple Cluster Environments (다시점 및 다중클러스터 환경에서 네트워크를 이용한 효율적인 실시간 영상 합성 기법)

  • You, Kang-Soo;Lim, Eun-Cheon;Sim, Chun-Bo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2251-2259
    • /
    • 2009
  • We propose an algorithm and system which generates 3D stereo image by composition of 2D image from 4 multiple clusters which 1 cluster was composed of 4 multiple cameras based on network. Proposed Schemes have a network-based client-server architecture for load balancing of system caused to process a large amounts of data with real-time as well as multiple cluster environments. In addition, we make use of JPEG compression and RAM disk method for better performance. Our scheme first converts input images from 4 channel, 16 cameras to binary image. And then we generate 3D stereo images after applying edge detection algorithm such as Sobel algorithm and Prewiit algorithm used to get disparities from images of 16 multiple cameras. With respect of performance results, the proposed scheme takes about 0.05 sec. to transfer image from client to server as well as 0.84 to generate 3D stereo images after composing 2D images from 16 multiple cameras. We finally confirm that our scheme is efficient to generate 3D stereo images in multiple view and multiple clusters environments with real-time.