• Title/Summary/Keyword: 4D Reconstruction

Search Result 338, Processing Time 0.027 seconds

Surgical Outcome of Tetralogy of Fallot in Adolt -Implication of Preoperative Cyanosis- (수술 전 청색증 정도에 따른 성인 활로씨 4징증의 임상 양상)

  • Kim Sang-hwa;Park Soon-Ik;Park Jung-Jun;Song Hyun;Lee Jae-Won;Seo Dong-Man;Song Meong-Gun;Song Jong-Min;Kang Duck-Hyun;Song Jae-Kwan;Jang Wan-Sook;Kim Young-Hwue;Yun Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.271-276
    • /
    • 2005
  • We analysed differences in operative methods and postoperative outcome according to the severity of preoperative cyanosis in adult ToF (Tetralogy of Fallot) patients. Material and Method: From August 1989 to June 2001, thirty three adult patients, 18 females and 15 males, underwent total correction for ToF. Their age ranged from 15 years to 54 years (median: 34). Patients were divided into 2 groups by preoperative $SaO_2$ (arterial oxygen saturation): group I$(n=cyanotic,\;SaO_2\;\geq94\%)$ and group II $(acyanotic,\; SaO_2\geq95%)$. Preoperative median hemoglobin level was higher in group I compared to group II (17.5 g/dl vs 15 g/dl). Postoperative follow-up duration ranged from 1 to 94 months (670 patient-month, median: 14 months), and 63 two-dimensional echocardiographic examinations were done during this period. Result: There were no early or late mortality. With regard to RVOT (right ventricular outflow tract) reconstruction, trans-annular patch and RV-PA extracardiac conduit were used in 7 and 3 patients respectively, and all of them belonged to group I. In group I, cardiopulmonary bypass time, aortic cross-clamping time, ICU day, hospital day were significantly longer than in group II, and postoperative inotropic support was significantly greater than in group II. There was no ventricular arrhythmia in both groups, and one patient in group I suffered from atrial arrhythmia, which was resolved spontaneously after tricuspid and pulmonary valve replacement. During follow-up periods, functional class, residual RVOT stenosis and pulmonary regurgitation, tricuspid regurgitation, occurrence of ventricular and atrial arrhythmias were comparable between two groups. Conclusion: In adult ToF patients with severe preoperative cyanosis, more aggressive RVOT reconstruction and careful postoperative care are mandatory. However intermediate-term outcome of this group of patients is comparable to the patients with minimal or no preoperative cyanosis.

Reconstruction of Vegetation During $9^{th}$ Century in Southern Korea: Anatomical and Dendrochronological Analysis of Waterlogged Woods Excavated at Cheonghea-jin Fort

  • Han, Sang-Hyo;Park, Won-Kyu;Kim, Yo-Jung;Jung, Suk-Bae
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.2
    • /
    • pp.117-122
    • /
    • 2003
  • This study is conducted to examine the woods that were excavated at Jangdo Island. The Jangdo site is located in a small island some 180 meters away from the main island of Wando, Jeollanam-do in southern Korea. This site is known as Cheong-Hea Jin fort for the marine King Jang Bogo during the early 9$^{th}$ century. Total of 101 specimens were collected in three groups; small-size piles, log fences (Mok-check) and logs from a well. The species of the group of piles consisted of Quercus spp. (43%), Pinus densiflora (29%), Pinus koraiensis (5%), Alnus japonica (3%), Fraxinus spp. (3%), Styrax obassia (3%), Juglans spp. (2%), Zelkova serrata (2%), Platycarya strobilacea (2%), Celtis spp. (2%), Torreya nucifera (2%), Quercus myrsinaefolia (2%), and Cinnamomum spp. (2%). The species of Mok-check and logs from the well were identified as all Pinus densiflora. The species composition indicated that the climate around A. D. 9th-10th century in southern Korea was similar to the present.. The wooden fences were also examined for tree-ring analysis. The ages of woods were 50∼60 years. We made two site chronologies. The chronologies indicated that southeastern and southwestern fences were repaired frequently. The results could not give the absolute dates due to lack of reference chronologies in this period.

  • PDF

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?

  • Sung, Jae-Hoon;Kim, Il-Sup;Yang, Seung-Ho;Hong, Jae-Taek;Son, Byung-Chul;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.107-111
    • /
    • 2011
  • Objective : The aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for prevention of tracheoinnominate artery fistula. Methods : The authors retrospectively analyzed 22 patients with tracheostomy who had checked CT angiography. To evaluate the relationship between tracheostomy tube and innominate artery, we divided into three categories. First proximal tube position based on cervical vertebra, named "tracheostomy tube departure level (TTDL)". Second, distal tube position and course of innominate artery, named "tracheostomy tube-innominate artery configuration (TTIC)". Third, the gap between the tube and innominate artery, named "tracheostomy tube to innominate artery gap (TTIG)". The TTDL/TTIC and TTIG are based on 3-dimensional (3D) reconstruction around tracheostomy and enhanced axial slices of upper chest, respectively. Results : First, mean TTDL was $6.8{\pm}0.6$. Five cases (23%) were lower than C7 vertebra. Second, TTIC were remote to innominate artery (2 cases; 9.1 %), matched with it (14 cases; 63.6%) or crossed it (6 cases; 27.3%). Only 9% of cases were definitely free from innominate artery injury. Third, average TTIG was $4.3{\pm}4.6$ mm. Surprisingly, in 6 cases (27.3%), innominate artery, trachea wall and tracheostomy tube were tightly attached all together, thus have much higher probability of erosion. Conclusion : If low TTDL, match or crossing type TTIC with reverse-L shaped innominate artery, small trachea and thin TTIG are accompanied all together, we may seriously consider early plugging and tube removal.

Analysis of Sunshine Amount for Education Environment according to Installation of Apartment Structures (아파트 구조물 설치에 따른 교육환경 일조량 분석)

  • Jang, Ho-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • Due to recent urban maintenance project for the aged towns, the reconstruction of apartments into super-high-rise and high-rise apartment structures has been approved for concentrated use of land, and accordingly the infringement on sunshine for nearby residential area is rising as a social issue. Especially the educational environment conditions according to infringement on sunshine in educational facilities are posing many problems. Accordingly in this study, for such sunshine analysis of educational environment, Auto $CAD^{(R)}$ software has been used to construct the 3D model for the educational facility structures. And with the simulation technique, the windows and the schoolyard of the education facility were set to be the lighting standard surface to take measurements for the sunshine environment of the educational facilities by the minute from 8:00AM until 4:00PM for the sunshine amount by true solar time according to the movement of the sun. Also, the sunshine environment of the education facility according to the damage before/after new construction of apartments was charted, and through comparison with the video produced by sun shadow projection method, the sunshine amount of the educational environment could be verified. In future, it is expected to be efficiently used in the sunshine analysis of education environment utilizing such simulation techniques.

A comparative study to measure the condylar guidance by the radiographic and clinical methods

  • Shreshta, Pragya;Jain, Veena;Bhalla, Ashu;Pruthi, Gunjan
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.153-157
    • /
    • 2012
  • PURPOSE. The study was conducted to compare the radiographic and clinical methods of measuring the horizontal condylar guidance (HCG) values. MATERIALS AND METHODS. The condylar guidance was measured using the radiographic (CT scan) and three clinical methods i.e. the wax protrusive records, Lucia jig record and intraoral central bearing device in 12 patients aged between 20-40 years irrespective of sex. The records were taken and transferred on the semi-adjustable articulator to record the HCG values. The CT scan was taken for 3D reconstruction of the mid facial region. Frankfort horizontal plane (FHP) and a line extending from the superior anterior most point on the glenoid fossa to the most convex point on the apex of articular eminence (AE) was marked on the CT scan. An angle between these two lines was measured on both right and left sides to obtain condylar inclination angle. Three interocclusal protrusive wax and jig records were taken and transferred to the semi adjustable articulator. Three readings were recorded on each side. Similarly the records were taken and transferred to the same articulator using the intra oral central bearing device to record the readings. RESULTS. The statistical analysis showed insignificant differences in the HCG values between the right and left sides [(P=.589 (CT), P=.928 (wax), P=.625 (jig), P=.886 (tracer)]. The clinical methods provided low Pearsons correlation values [(R = 0.423 (wax), R = 0.354 (jig), R = 0.265 (tracer)] for the right as well as the left sides when compared with the CT values. Among the clinical methods, jig and wax method showed strong level of association which is statistically significant while the intra-oral tracer showed weak association with the other two methods. CONCLUSION. The right and left HCG values were almost similar. The CT scan showed higher HCG values than the clinical methods and among the clinical methods, values obtained from all the methods were comparable.

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

A Study on the Reproducibility of 3D Shape Model of Garden Cultural Heritage using Photogrammetry with SNS Photographs - Focused on Soswaewon Garden, Damyang(Scenic Site No.40) - (SNS 사진과 사진측량을 이용한 정원유산의 3차원 형상 재현 가능성 연구 - 명승 제40호 담양 소쇄원(潭陽 瀟灑園)을 대상으로 -)

  • Kim, Choong-Sik;Lee, Sang-Ha
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.4
    • /
    • pp.94-104
    • /
    • 2018
  • This study examined photogrammetric reconstruction techniques that can measure the original form of a cultural property utilizing photographs taken in the past. During the research process, photographs taken in the past as well as photograph on the internet of Soswaewon Garden in Damyang(scenic site 40) were collected and utilized. The landscaping structures of Maedae, Aiyangdan, Ogokmun Wall, and Yakjak and natural scenery Gwangseok, of which photographs can be taken from any 360 degree direction from a close distance or a far distance without any barriers in the way, were selected and tested for the possibility of reproducing three-dimensional shapes. The photography method of 151 landscape photographs (58.6%) from internet portal sites for the aforementioned five landscape subjects containing information on the date the photograph was taken, focal length, and exposure were analyzed. As a result of the analysis, it was revealed that the majority of the photographs tend to focus on important parts of each subject. In addition, we discovered that there are two or three photography methods that internet users preferred in regards to each landscape subject. For the purposes of the experiment, photographs in which a single scene consistently appears for each landscape subject and it was determined that there was a high level of preference related to the photography method were analyzed, and three-dimensional mesh shape model was produced with a photoscan program to analyze the reproducibility of three-dimensional shapes. Based on the results of the reproduction, it was relatively possible to reproduce three-dimensional shapes for artifacts such as Ogukmun wall, Maedae, and Aeyangdan, but it was impossible to reproduce three-dimensional images for natural scenery or an object that has similar texture such as Yakjak and Gwangseok. As a result of experimentation related to the reconstruction of three-dimensional shapes with the photographs taken on site using a photography method similar to that of the photographs selected as previously mentioned, there was success related to reproducing the three-dimensional shapes of Yakjak and Gwangseok, of which it was not possible to do so through the photographs that had been collected previously. In addition, through comparison of past and present images, it was possible to measure the exact sizes as well as discover any changes that have taken place. If past photographs taken by tourists or landscape architects of cultural properties can be obtained, the three-dimensional shapes from a particular period of time can be reproduced. If this technology becomes widespread, it will increase the level of accuracy and reliability in regards to measuring the past shapes of cultural landscape properties and examining any changes to the properties.

3-D CT EVALUATION OF CONDYLE HEAD POSITION, MANDIBULAR WIDTH, AND MANDIBULAR ANGLE AFTER MANDIBULAR SETBACK SURGERY (3-D CT를 이용한 악교정수술후의 하악 과두 위치와 하악폭경 및 하악각의 평가)

  • Kim, Jae-Won;Lee, Dong-Hyun;Lee, Su-Youn;Kim, Jae-Hyun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.229-239
    • /
    • 2009
  • The purpose of this study is to evaluate the change in condylar position, width, and angle before and after orthognathic surgery using 3-dimensional computed tomograph. Pre and posterative 3-D CT was taken on 38 patients and through axial, frontal, sagittal measurements and by 3-dimensional reconstruction, the changes in condylar postion, mandibular width and angle were analyzed and others such as the difference in gender, operation and fixation method, setback length and in relation with temporomandibular disorders were done together too. The results were as follows: The inward rotation of condyle in axial condylar angle, the forward movement of right condyle in sagittal anterior-posterior distance, the superior movement of both condyles in sagittal superior-inferior distance, the decrease in gonial angle, the increase in mandibular width, the decrease in distance between the axial coronoid process distance and the increase in the frontal intercondylar distance were statistically significant. There were no statistically significant changes in gender difference, however in the difference in operation method, change in the gonial angle was observed and there was more change in bilateral sagittal split osteotomy group compared to two-jaw surgery group. In the difference in fixation method, the decrease in axial coronoid process distance and the change in sagittal anterior-posterior distance were statistically significant. In the difference in setback, the increase in setback didn't relate directly with the increased change in condyle position. In the relation with temporomandibular disorder, changes in left axial condylar angle and axial coronoid process distance were statistically significant. Changes in condylar position could be observed after the orthognathic surgery but it doesn't seem to have much of a clinical importance. The orthognathic surgery is effective in decreasing the mandibular angle, and it is not related with the temporomandibular disorder.

Interpolation and Reconstruction of the Holocene Sea-levels Using Inverse Fractal Interpolation functions (프랙탈 내삽함수 역산법을 이용한 홀로세 해수면의 내삽 및 재구성)

  • CHUNG, SANG YONG;KIM, DAE CHOUL;YI, HI-IL
    • 한국해양학회지
    • /
    • v.29 no.3
    • /
    • pp.228-238
    • /
    • 1994
  • The change of sea-level is a good indicator of the change of climate during the Quaternary period. The sea-levels in the world have been changing very irregularly during that time. The pattern of the Quaternary sea-level change was assumed to be a stochastic fractal in this study. We measured fractal dimensions of the Holocene sea-levels of the Hudson river estuary and the Delaware coast. A box counting method gave almost the same values. i.e., D=1.358 for the Hudson sea-level changes and D+1.346 for the Delaware sea-level changes. the ability of the inverse method of fractal interposea-levels. IFIF reproduction the realistic sea-levels for the both of them. The delaware sea-level data made less statistical errors for the interpolation of IFIF than the Hudson and the Delaware sea-levels. IFIF reproduction the realistic sea-levels for the both of them. The Delaware sea-level data made less statistical errors for the interpolation of IFIF than the Hudson sea-level data. This suggests that the Delaware sea-level data are more reliable than the Hudson sea-level data was calculated from the fractal dimension of the Delaware sea-level data. Fractal interpolation functions (FIF) was used to reconstruct the peleosea-levels of the Korean coasts and the Atlantic Ocean coasts of the United States. The Korean Peleosea-level change generacted by FIF is different from the peleosea-level change of the eastern U.S.. The Korean peleosea-levels are much higher than the eastern U.S. Paleosea-levels, comparing to each other from the present to 8,000 BP.

  • PDF

Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT (PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가)

  • Choong-Woon Lee;Yeon-Wook You;Jong-Woon Mun;Yun-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF