• 제목/요약/키워드: 400 MHz

검색결과 293건 처리시간 0.026초

Insertion Loss Analysis According to the Structural Variant of Interposer (인터포저의 디자인 변화에 따른 삽입손실 해석)

  • Park, Jung-Rae;Jung, Cheong-Ha;Kim, Gu-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • 제28권4호
    • /
    • pp.97-101
    • /
    • 2021
  • In this study, Insertion loss according to the structural variant of interposer to Through Silicon Via (TSV) and Redistributed Layer (RDL) was studied through design of experiment. 3-Factors was considered as a variant, TSV depth, TSV diameter, RDL width with factor arrangement method and the response surface method from 400 MHz to 20 GHz. As a result, it was confirmed that as the frequency increased, the effect of RDL width was decreased and the effect of TSV depth and TSV diameter was increased. Also within the analysis range, to increasing RDL width, decreasing TSV depth, and fixing TSV diameter about 10.7 ㎛ was observed optimal result of Insertion loss.

Ultra-Low Power MICS RF Transceiver Design for Wireless Sensor Network (WSN 을 위한 초저전력 MICS RF 송수신기 기술 개요 및 설계 기법)

  • Gyu-won Kim;Yu-jung Kim;Junghwan Han
    • Transactions on Semiconductor Engineering
    • /
    • 제2권1호
    • /
    • pp.9-16
    • /
    • 2024
  • This paper discusses the design of bio-implanted ultra-low-power MICS RF transceivers for wireless sensor networks. The 400 MHz MICS standard was considered for the implementation of the WBAN wireless sensor system, indirectly minimizing radio propagation losses in the human body and the inference with surrounding networks. This paper includes link budget, various transmission and reception architectures for a system design and ultra-low power transceiver circuit techniques for the implementation of RF transceivers that meet MICS standards.

Influence of Sputtering Conditions on The Coercive Force and Effective Permeability of Permalloy Thin Films (퍼멀로이 박막의 보자력 및 실효투자율에 미치는 스퍼터링 조건의 영향)

  • 김현태;김상주;한석희;김희중;강일구;김인응
    • Journal of the Korean Magnetics Society
    • /
    • 제4권3호
    • /
    • pp.201-207
    • /
    • 1994
  • RF 마그네트론 스퍼터링법으로 제작된 퍼멀로이(NiFe) 박막에 대하여 투입전력, 아르곤 압력, 바이어스 전압등의 스퍼터링 조건이 퍼멀로이 박막의 자기특성에 미치는 영향을 조사하였다. 투입전력에 따른 보자력의 변화는 300~400W에서 낮은 값을 지녔으며 아르곤 압력에 따른 변화는 1~5mTorr에서 낮은 값을 나타내었다. 스퍼터링 조건에 따른 최소의 보자력값은 400 W, 5mTorr 와 300 W, 2mTorr에서 각각 0.10 Oe를 나타내었고 최대의 투자율값은 400 W, 5mTorr에서 2800(1 MHz)을 나타내었다. 또한 저압의 스 퍼터링 압력에서 바이아스를 가할 경우 보자력은 이에 비례해서 오히려 증가하였다. 박막의 Ni 함량의 변화는 아르곤 압력이 증가함에 따라 점차적으로 감소하나 2~10mTorr 범위에서는 다시 증가하는 경향을 보였다. 내부응력은 아르곤 압력이 증가함에 따라 압축응력에서 인장응력으로 변하였으며 5mTorr에서 내 부응력이 거의 사라졌다.

  • PDF

Design of UWB Antenna for the External Receiver of Capsule Endoscopy (캡슐 내시경의 외부 수신기용 UWB 안테나 설계)

  • Kim Hong-Seok;Oh Min-Seok;Cheon Chang-Yul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제16권8호
    • /
    • pp.790-796
    • /
    • 2005
  • In order to accomplish a wireless communication of capsule endoscopy, an environment study in the human body and receiving antenna design have been performed. The proposed antenna is the loop antenna designed to minimize the propagation loss in multi-loss layer such as the human body and utilize the magnetic field. Considering the propagation loss in the human body, the frequency range is from 400 MHz to 500 MHz. Acorrrding to the FCC regulations, the permittivity and conductivity for each human tissue were extracted. We set up an equivalent model and make an aqueous solution which is replaced with the human body. Due to movement of capsule in the human body which propagation loss is extremly severe, an array antenna is required. Irrespective of the location of transmission antenna transmitting a signal of 1 mW, we confirme what it is possible for the enough signal detection as the average signal level of array antenna is -60 dBm.

Thickness Dependence of Microwave Permeability in CoFeHfO Thin Films (CoFeHfO 박막 재료의 두께에 따른 마이크로파 투자율 특성)

  • Lee, Young-Suk;Kim, Cheol-Gi;Kim, Dong-Young
    • Journal of the Korean Magnetics Society
    • /
    • 제20권6호
    • /
    • pp.228-233
    • /
    • 2010
  • The microwave permeability was measured in order to analyze the thickness dependence of loss properties in CoFeHfO thin films with varying thickness of t = 57~1368 nm. A single resonance peak (P1) at 2.95 GHz was appeared in the samples with thickness less than 405 nm, while second resonance peak (P2) at 547MHz was additionally appeared in the samples with thickness greater than 405 nm. The P2 was originated by the angle distribution of the easy axis, which was confirmed from the measured results of the change of imaginary permeability with applied magnetic field in the sample of 1368 nm thickness and low field torque curves. If the second peaks can be reduced by minimizing the angle distribution of the easy axis, the CoFeHfO thin films with thickness greater than 400 nm can be used for the compact microwave devices operated at up to 2 GHz ranges.

Real-time Implementation of the AMR-WB+ Audio Coder using ARM Core(R) (ARM Core(R)를 이용한 AMR-WB+ 오디오 부호화기의 실시간 구현)

  • Won, Yang-Hee;Lee, Hyung-Il;Kang, Sang-Won
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제46권3호
    • /
    • pp.119-124
    • /
    • 2009
  • In this paper, AMR-WB+ audio coder is implemented, in real-time, using Intel 400MHz Xscale PXA250 with 32bit RISC processor ARM9E-J(R)core. The assembly code for ARM9E-J(R)core is developed through the serial process of C code optimization, cross compile, assembly code manual optimization and adjusting the optimized code to Embedded Visual C++ platform. C code is trimmed on Visual C++ platform. Cross compile and assembly code manual optimization are performed on CodeWarrior with ARM compiler. Through these stages the code for both ARM EVM board and PDA is implemented. The average complexities of the code are 160.75MHz on encoder and 33.05MHz on decoder. In case of static link library(SLL), the required memories are 65.21Kbyte, 32.01Kbyte and 279.81Kbyte on encoder, decoder and common sources, respectively. The implemented coder is evaluated using 16 test vectors given by 3GPP to verify the bit-exactness of the coder.

A Triangular Microstrip Antenna with T-Shaped Slits for Tunable Dual-Band Applications (T자 모양 슬릿 구조를 이용한 이중 대역 공진 주파수 변환 삼각형 마이크로스트립 안테나)

  • Lee, Keon-Myung;Sung, Young-Je;Kim, Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제20권2호
    • /
    • pp.141-146
    • /
    • 2009
  • A triangular microstrip antenna with T-shaped slits is proposed for tunable dual-band applications. The proposed antenna is designed using chip capacitors as a prototype. From this result the capacitor can be replaced to a varactor diode to control capacitance value. Since the input impedance of the antenna can be varied with the value of the chip capacitors on the T-shaped slits, the resonant frequency may be changed. The return losses are better than 10 dB at the lower band of $0.78{\sim}1.21$ GHz and 20 dB at the upper band of $1.97{\sim}2.17$ GHz, respectively. This antenna has the bandwidth of about 10 MHz and 50 MHz at each band. The peak gains of the antenna yield 0 dBi at the lower band and 3 dBi at the upper band, respectively. Details of the antenna design are described, and its performances are presented and analyzed.

Design and Implementation of Wideband Ultra-Fast High Precision Frequency Synthesizer for ELINT Equipment (ELINT 장비용 광대역 초고속 고정밀 주파수 합성기 설계 및 구현)

  • Lee, Kyu-Song;Jeon, Kye-Ik;Oh, Seung-Hyeub
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제20권11호
    • /
    • pp.1178-1185
    • /
    • 2009
  • In this paper, a wideband ultra-high speed & high purity discrete frequency synthesizer having minimum 2.5 MHz step size was proposed. To achieve fast and wideband operation, discrete frequencies were synthesized by mixing of 3 different pre-synthesized 16 frequencies made from fixed PLL and frequency dividers. Frequencies with discrete 2.5 MHz step were produced in 710~1,610 MHz. The measured hopping response time was 350 nsec average, output level was 21.5 dBm average with 2.65 dB flatness, spurious and harmonics level were suppressed below -60 dBc, and phase noise was -94 dBc/Hz@100 Hz. Also, a new measurement method for synthesizer response time was described.

Physical Properties of Polymer Impregnated Concrete Prepared using Microwave Radiation (Microwave Radiation을 이용하여 제조된 고분자 함침 콘크리트의 물리적 특성)

  • Ku, Du Hyun;Park, Jung Soon;Park, Heon Young;Hur, Myung Jun;Lee, Won Mook
    • Applied Chemistry for Engineering
    • /
    • 제19권3호
    • /
    • pp.345-350
    • /
    • 2008
  • Polymer Impregnated Concrete (PIC) prepared from Ordinary Portland Cement Concrete (OPC) has excellent mechanical properties as well as physico-chemical properties. For the manufacturing of PIC, drying process of basis concrete (precast concrete), impregnation process with evacuation system and ultrasonic vibration system, polymerization process of monomers are essential. Modified microwave reactor using magnetron was used for polymerization of styrene/MMA (1 : 1) impregnated in pore volume of basis concrete. From the experimental results, the degree of polymerization increased up to 30% and more homogeneous PIC was prepared as compared to the conventional thermal method. Also the mechanical strengths increased more than 400% ($800{\sim}1200kg_f/cm^2$) and the resistance for corrosion to acids was improved up to 25%. AIBN and BPO as initiators for polymerization were used at the concentration less than 1%. Optimum conditions for polymerization were obtained at the frequency of microwave of 400 W and 2450 MHz, and optimum reaction temperature was $120^{\circ}C$ at an atmospheric pressure.

Implementation of 1.7MHz, 25W Wireless Power Transmission(WPT) System using Coupled Magnetic Resonance (1.7MHz, 25W급 자기공명 무선전력 전송 시스템 구현)

  • Kim, Seong-Min;Cho, In-Gui;Moon, Jung-Ick
    • Journal of IKEEE
    • /
    • 제17권3호
    • /
    • pp.317-323
    • /
    • 2013
  • In this paper, 25W wireless power transmission(WPT) system using the coupled magnetic resonance is presented. The WPT system consists of a 100W class-F power transmitter, 1.7MHz magnetic resonators and a 40W full-bridge receiver using diodes. Especially, the transmit power control function using the 400MHz FSK communication between the transmitter and the receiver is adopted in the proposed system for the stable power transmission. Using the system and the power control function, the WPT system can be adopted in the various electronic devices and the commercialization of WPT system can be moved forward.