• Title/Summary/Keyword: 4-Camera

Search Result 2,368, Processing Time 0.046 seconds

Response of Structural, Biochemical, and Physiological Vegetation Indices Measured from Field-Spectrometer and Multi-Spectral Camera Under Crop Stress Caused by Herbicide (마늘의 제초제 약해에 대한 구조적, 생화학적, 생리적 계열 식생지수 반응: 지상분광계 및 다중분광카메라를 활용하여)

  • Ryu, Jae-Hyun;Moon, Hyun-Dong;Cho, Jaeil;Lee, Kyung-do;Ahn, Ho-yong;So, Kyu-ho;Na, Sang-il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1559-1572
    • /
    • 2021
  • The response of vegetation under the crop stress condition was evaluated using structural, biochemical, and physiological vegetation indices based on unmanned aerial vehicle (UAV) images and field-spectrometer data. A high concentration of herbicide was sprayed at the different growth stages of garlic to process crop stress, the above ground dry matter of garlic at experimental area (EA) decreased about 46.2~84.5% compared to that at control area. The structural vegetation indices clearly responded to these crop damages. Spectral reflectance at near-infrared wavelength consistently decreased at EA. Most biochemical vegetation indices reflected the crop stress conditions, but the meaning of physiological vegetation indices is not clear due to the effect of vinyl mulching. The difference of the decreasing ratio of vegetation indices after the herbicide spray was 2.3% averagely in the case of structural vegetation indices and 1.3~4.1% in the case of normalization-based vegetation indices. These results meant that appropriate vegetation indices should be utilized depending on the types of crop stress and the cultivation environment and the normalization-based vegetation indices measured from the different spatial scale has the minimized difference.

GPR Development for Landmine Detection (지뢰탐지를 위한 GPR 시스템의 개발)

  • Sato, Motoyuki;Fujiwara, Jun;Feng, Xuan;Zhou, Zheng-Shu;Kobayashi, Takao
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.4
    • /
    • pp.270-279
    • /
    • 2005
  • Under the research project supported by Japanese Ministry of Education, Culture, Sports, Science and Technology (MEXT), we have conducted the development of GPR systems for landmine detection. Until 2005, we have finished development of two prototype GPR systems, namely ALIS (Advanced Landmine Imaging System) and SAR-GPR (Synthetic Aperture Radar-Ground Penetrating Radar). ALIS is a novel landmine detection sensor system combined with a metal detector and GPR. This is a hand-held equipment, which has a sensor position tracking system, and can visualize the sensor output in real time. In order to achieve the sensor tracking system, ALIS needs only one CCD camera attached on the sensor handle. The CCD image is superimposed with the GPR and metal detector signal, and the detection and identification of buried targets is quite easy and reliable. Field evaluation test of ALIS was conducted in December 2004 in Afghanistan, and we demonstrated that it can detect buried antipersonnel landmines, and can also discriminate metal fragments from landmines. SAR-GPR (Synthetic Aperture Radar-Ground Penetrating Radar) is a machine mounted sensor system composed of B GPR and a metal detector. The GPR employs an array antenna for advanced signal processing for better subsurface imaging. SAR-GPR combined with synthetic aperture radar algorithm, can suppress clutter and can image buried objects in strongly inhomogeneous material. SAR-GPR is a stepped frequency radar system, whose RF component is a newly developed compact vector network analyzers. The size of the system is 30cm x 30cm x 30 cm, composed from six Vivaldi antennas and three vector network analyzers. The weight of the system is 17 kg, and it can be mounted on a robotic arm on a small unmanned vehicle. The field test of this system was carried out in March 2005 in Japan.

Chemistry of mist deposition of organic polymer PEDOT:PSS on crystalline Si

  • Shirai, Hajime;Ohki, Tatsuya;Liu, Qiming;Ichikawa, Koki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.388-388
    • /
    • 2016
  • Chemical mist deposition (CMD) of poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) was investigated with cavitation frequency f, solvent, flow rate of nitrogen, substrate temperature $T_s$, and substrate dc bias $V_s$ as variables for efficient PEDOT:PSS/crystalline (c-)Si heterojunction solar cells (Fig. 1). The high-speed camera and differential mobility analysis characterizations revealed that average size and flux of PEDOT:PSS mist depend on f, solvent, and $V_s$. The size distribution of mist particles including EG/DI water cosolvent is also shown at three different $V_s$ of 0, 1.5, and 5 kV for a f of 3 MHz (Fig. 2). The size distribution of EG/DI water mist without PEDOT:PSS is also shown at the bottom. A peak maximum shifted from 300-350 to 20-30 nm with a narrow band width of ~150 nm for PEDOT:PSS solution, whose maximum number density increased significantly up to 8000/cc with increasing $V_s$. On the other hand, for EG/water cosolvent mist alone, the peak maximum was observed at a 72.3 nm with a number density of ~700/cc and a band width of ~160 nm and it decreased markedly with increasing $V_s$. These findings were not observed for PEDOT:PSS/EG/DI water mist. In addition, the Mie scattering image of PEDOT:PSS mist under white bias light was not observed at $V_s$ above 5 kV, because the average size of mist became smaller. These results imply that most of solvent is solvated in PEDOT:PSS molecule and/or solvent is vaporized. Thus, higher f and $V_s$ generate preferentially fine mist particle with a narrower band width. Film deposition occurred when $V_s$ was impressed on positive to a c-Si substrate at a Ts of $30-40^{\circ}C$, whereas no deposition of films occurred on negative, implying that negatively charged mist mainly provide the film deposition. The uniform deposition of PEDOT:PSS films occurred on textured c-Si(100) substrate by adjusting $T_s$ and $V_s$. The adhesion of CMD PEDOT:PSS to c-Si enhanced by $V_s$ conspicuously compared to that of spin-coated film. The CMD PEDOT:PSS/c-Si solar cell devices on textured c-Si(100) exhibited a ${\eta}$ of 11.0% with the better uniformity of the solar cell parameters. Furthermore, ${\eta}$ increased to 12.5% with a $J_{sc}$ of $35.6mA/cm^2$, a $V_{oc}$ of 0.53 V, and a FF of 0.67 with an antireflection (AR) coating layer of 20-nm-thick CMD molybdenum oxide $MoO_x$ (n= 2.1) using negatively charged mist of 0.1 wt% 12 Molybdo (VI) phosphoric acid n-Hydrate) $H_3(PMo_{12}O_40){\cdot}nH_2O$ in methanol. CMD. These findings suggest that the CMD with negatively charged mist has a great potential for the uniform deposition of organic and inorganic on textured c-Si substrate by adjusting $T_s$ and $V_s$.

  • PDF

A Kinematic Analysis of Uchi-mata(inner thigh reaping throw) by Kumi-kata types in Judo (유도 맞잡기 타입에 따른 허벅다리걸기의 Kinematic 분석[I])

  • Kim, Eui-Hwan;Cho, Dong-Hee;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.63-87
    • /
    • 2002
  • The purpose of this study was to analyze the kinematic variables when Uchi-mata(inner thigh reaping throw) performing by Kumi-kata(engagement position, basic hold) types A, B(A: grasping part-behind neck lapel, B: chest lapel) in Judo with three dimensional analysis technique DLT method by videography. The subjects were four male judokas who have been training in Yong-In University(YIU), on Korean Representative level and Uchi-mata is their tokui-nage(favorite technique), the throwing form was filmed on two S-VHS 16mm video camera( 30frame/sec. Panasonic). Kinematic variables were temporal, posture, and COG. The data collection was performing by Uchi-mata. Six good trials were collected for each condition (type A, B) among over 10 trials. The mean values and the standard deviation for each variable were obtained and used as basic factors for examining characteristics of Uchi-mata by Kumi-kata types. The results of this analysis were as follows : 1) Temporal variables The total time elapsed(TE) by Uchi-mata of types A, B were 1.45, 1.56 sec. respectively. Types A shorter than B. 2) Posture variables In performing of Uchi-mata, the range of flexion in type A, left elbow was $45^{\circ}$ and B was $89^{\circ}$ from Event 2(E2) to Event 6(E6). Type A and B were quite different in right elbow angle in Event1(E1). Left shoulder angle of type A was extended and type B was flexed in E4. Both types right shoulder angles were showed similar pattern. Also both hip angles(right/left) were showed similar pattern. When type A performed Uchi-mata the knee-angle of supporting foot showed $142^{\circ}$in the 1st stage of kake phase[KP], and extended to $147^{\circ}$in the 2nd stage of KP. And the foot-ankle angle of supporting foot showed $83^{\circ}$in the 1st stage of KP, and extended to $86^{\circ}$in the 2nd stage of KP. moreover, The knee angle of attacking foot showed $126^{\circ}$in the 1st stage of KP, and extended to $132^{\circ}$in the 2nd stage of KP, and the foot-ankle angle of attacking foot showed $106^{\circ}$in the 1st stage of KP, and extended to $121^{\circ}$in the 2nd stage of KP. When type B performed Uchi-mata the knee-angle of supporting foot showed $144^{\circ}$in the 1st stage of KP, and extended to $154^{\circ}$in the 2nd stage of KP. And the foot-ankle angle of supporting foot showed $83^{\circ}$in the 1st stage of KP, and extended to $92^{\circ}$in the 2nd stage of KP. moreover, The knee angle of attacking foot showed $132^{\circ}$in the 1st stage of KP, and extended to $140^{\circ}$in the 2nd stage of KP, and the foot-ankle angle of attacking foot showed $103^{\circ}$in the 1st stage of KP, and extended to $115^{\circ}$in the 2nd stage of KP. During Uchi-mata performing, type A showed pulling pattern and type B showed lift-pulling pattern. As Kumi-kata types, it were different to upper body(elbow, shoulder angle), but mostly similar to lower body(hip, knee, ankle angle) on both types. 3) C. O. G. variables When the subjects performed Uchi-mata, COG of type A, B up and down in vertical aspect was 71cm, 73.8cm in height from the foot in the 2nd stage of KP. As Kumi-kata types, it were different on medial-lateral direction aspect but weren't different in Kuzushi phase on vertical direction aspect.

The Effect of Attenuation Correction with CT on the Interpretation of Myocardial Perfusion SPECT: in Patients with Normal Coronary Angiogram (관상동맥조영술상 정상소견을 보인 환자에서 전산화단층촬영술(CT)를 이용한 감쇠보정이 심근관류 SPECT의 판독에 미치는 영향)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Kyu-Chang;Lee, Hyung-Woo;Hong, Geu-Ru;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.246-251
    • /
    • 2005
  • Purpose: There has been many reports for the effect of attenuation correction on myocardial perfusion SPECT. We studied the effect of attenuation correction with CT (computed tomography) in patients with normal coronary angiography. Materials and Methods: Fifteen patients with normal coronary artery on angiography and low likelihood of coronary artery disease were enrolled in this study (male: 6, female: 9, mean age: $58{\pm}8$ year). Myocardial perfusion SPECT was done with Millennium VG with Hawkeye device (GE, SPECT/CT camera). A visual analysis and polar map quantification (Emory tool box) was performed. In quantitative analysis, percent uptake of each myocardial wall on polar map (percent of maximal uptake) was compared between non-corrected (NC) and corrected (AC) images. Results: Visual analysis showed AC images led to an increase of uptake in the inferior wall, but decrease of uptake in the anterior wall, apex and septum. liver activity is also increased in AC images. In quantitative analysis, the percent uptake is decreased in the anterior wall, apex and septum, but increased in the inferior wall. It is helpful to interpret the images in the inferior wall after AC, but difficult in the apex and anterior wall after AC. Conclusion: AC is helpful in the inferior wall. But in the apex or anterior wall, AC must be carefully applied to normal perfused myocardium.

Nuclear Imaging Evaluation of Galactosylation of Chitosan (핵의학 영상을 이용한 chitosan의 galactosylation 효과에 대한 평가)

  • Jeong, Hwan-Jeong;Kim, Eun-Mi;Park, In-Kyu;Cho, Chong-Su;Kim, Chang-Guhn;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.253-258
    • /
    • 2004
  • Purpose: Chitosan has been studied as a non-viral gene delivery vector, drug delivery carrier, metal chelator, food additive, and radiopharmaceutical, among other things. Recently, galactose-graft chitosan was studied as a non-viral gene and drug delivery vector to target hepatocytes. The aim of this study was to investigate the usefulness of nuclear imaging for in vivo evaluation of targeting the hepatocyte by galactose grafting. Methods and Materials: Galactosyl methylated chitosan (GMC) was produced by methylation to lactobionic acid coupled chitosan. Cytotoxicity of $^{99m}Tc$-GMC was determined by MTT assay. Rabbits were injected via their auricular vein with $^{99m}Tc$-GMC and $^{99m}Tc$-methylated chitosan (MC), the latter of which does not contain a galactose group, and images were acquired with a gamma camera equipped with a parallel hole collimator. The composition of the galactose group in galactosylated chitosan (GC), as well as the tri-, di-, or mono-methylation of GMC, was confirmed by NMR spectroscopy. Results: The results of MTT assay indicated that $^{99m}Tc$-GMC was non-toxic. $^{99m}Tc$-GMC specifically accumulated in the liver within 10 minutes of injection and maintained high hepatic uptake. In contrast, $^{99m}Tc$-MC showed faint liver uptake. $^{99m}Tc$-GMC scintigraphy of rabbits showed that the galactose ligand principally targeted the liver while the chitosan functionalities led to excretion through the urinary system. Conclusion: Bioconjugation with a specific ligand endows some degree of targetability to an administered molecule or drug, as in the case of galactose for hepatocyte in vivo, and evaluating said targetabililty is a clear example of the great benefit proffered by nuclear imaging.

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF

Dynamic Characteristics for the Model of Horn Fish Hemiramphus Sajor Surface Pair Trawl Gear (학공치 표층예망어구 모형의 운동특성)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.4
    • /
    • pp.285-295
    • /
    • 2001
  • This study describes the analysis on the dynamic characteristics of model as a fundamental studies for the horn fish Hemiramphus sajor surface pair trawl gear. The model experiments were carried out in a flume tank by using model net for the horn fish surface par trawl gear. The model net was made to the scale of 1/40 by scaling down two surfce par trawl boats of 6.67 and 9.98 ton used for sea experiment in the coast of Jeju Island. Dimensions of the model net were 1.2m for stretch length of net, 1.3m for float line, 1.0m for sinker line, 2.5g for floats, and 0.86g for sinkers. Experiments were conducted in the observation channel of a flume tank with experimental equipments used to change the distance between paired boats and towing velocity. Motion of model net during towing was recorded by two sets of digital camera which were placed in the top and side of the model net. The leading coordinate of net height and net mouth width was captured by the photograph analysis system. Through the experiment, we obtained the following results: 1. The relationship between the net hight(Nh) and towing velocity(Vt) during towing was found to be Nh=(2.39Db-$^{0.62})Vt^{0.56}$ and the relationship between the net mouth width (Nw) and towing velocity during towing was Nw=(0.96Db^{0.62})Vt^{0.11}$, where Db is the distance between paired boats. 2. The relationship between the net tension(Nt) and towing velocity during towing was found to be Nt=106.94Vt+1.43 and the model net becomes parallel to the water surface at the towing velocity larger than 1.5 Knot. 3. The relationship between the net opening area(Na) and towing velocity during towing was found to be Na=(2.28Db0.37)Vt.-0.45, and the relationship between the filtering volume(Fv) and towing velocity during towing was Fv=(69.9Db$^{0.37})Vt^{0.55}$. The net opening area and filtering volume reach maximum value at the distance of 25m between paired boats.

  • PDF

Comparisons of occlusal force according to occlusal relationship, skeletal pattern, age and gender in Koreans (한국인에서의 부정교합 여부와 골격형태, 연령, 성별에 따른 교합력의 비교)

  • Yoon, Hye-Rim;Choi, Yoon-Jeong;Kim, Kyung-Ho;Chung, Choo-Ryung
    • The korean journal of orthodontics
    • /
    • v.40 no.5
    • /
    • pp.304-313
    • /
    • 2010
  • Objective: The aim of this study was to evaluate the occlusal force and contact area and to find its associating factors in Koreans. Methods: Occlusal force and contact area in maximum intercuspation were measured using the Dental $Prescale^{(R)}$ system in 651 subjects (15 with normal occlusion, 636 with various malocclusions divided into subgroups according to the skeletal pattern, Angle's molar relationship, age and gender). Results: Occlusal force of the normal occlusion group ($744.5{\pm}262.6N$) was significantly higher than those of the malocclusion group ($439.0{\pm}229.9N$, $p$ < 0.05). Occlusal force was similar regardless of differences in ANB angle or Angle's molar classification, however the increase in vertical dimension significantly reduced occlusal force ($p$ < 0.05). Conclusions: Occlusal force was significantly lower in the malocclusion group compared to the normal occlusion group, and in females compared to males, but it was not affected by age, antero-posterior skeletal pattern or molar classification. Although a hyperdivergent facial pattern indicated lower occlusal force compared to a hypodivergent facial pattern, the differences in skeletal pattern were not the primary cause of its decrease, but a secondary result induced by the differences in occlusal contact area according to the facial pattern.

Influence of Gating and Attenuation-correction for Diagnostic Performance of Usual Rest/stress Myocardial Perfusion SPECT in Coronary Artery Disease (게이트 방법과 감쇠보정이 심근 관류 SPECT의 관상동맥질환 진단 성능에 미치는 영향)

  • Lee, Dong-Soo;Yeo, Jeong-Seok;So, Young;Cheon, Gi-Jeong;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.131-142
    • /
    • 1999
  • Purpose: Either gated myocardial perfusion SPECT or attenuation corrected SPECT can be used to improve specificity in the diagnosis of coronary artery disease. We investigated in this study whether gating or attenuation correction improved diagnostic performance of rest/stress perfusion SPECT in patients having intermediate pre-test likelihood of coronary artery disease. Materials and Methods: Sixty-eight patients underwent rest attenuation-corrected T1-20l/dipyridamole stress gated attenuation-corrected Tc-99m -MIBI SPECT using an ADAC vertex camera (M:F=29:39, aged $59{\pm}12$ years, coronary artery stenosis ${\geq}70%$, one vessel: 13, two vessel: 18, three vessel: 8, normal: 29). Using a five-point scale, three physicians graded the post-test likelihood of coronary artery disease for each arterial territory (1:normal, 2: possibly normal, 3:equivocal, 4. possibly abnormal, 5: abnormal). Sensitivity, specificity and area under receiver-operating-characteristic curves were compared for each operator between three methods : (A) non-attenuation-corrected SPECT; (B) gated SPECT added to (A): and (C) attenuation-corrected SPECT added to (B). Results: When grade 3 was used as the criteria for coronary artery disease, no differences in sensitivity and specificity were found between the three methods for each operator. Areas under receiver-operating-characteristic curves for diagnosis of coronary artery disease revealed no differences between each modality (p>0.05). Conclusion: In patients at intermediate risk of coronary artery disease, gated SPECT and attenuation- corrected SPECT did not improve diagnostic performance.

  • PDF