• Title/Summary/Keyword: 3dB

Search Result 13,177, Processing Time 0.035 seconds

Difference of Time Weighted Averages in Different Setting Ups for Noise Dosimeter (소음노출량측정기의 Set Up 방법간의 시간가중평균값(TWA)의 차이)

  • Yang, Hong Seok;Lee, Kwang Mook;Won, Jung Il
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.193-199
    • /
    • 1995
  • This study was designed to investigate the difference of time weighted average(TWA) of noise levels and noise doses by the different operating parameter settings such as exchange rate, threshold level and criterion level for noise dosimeter in the field measurements of noise at industrial working environments. The time weighted averages of noise level and noise doses for noise working environments were determined by noise dosimeter on 80 workers employed at 20 industrial establishments of 8 industries. The results obtained were as follows: 1. The mean time weighted average(TWA) of the noise working environments by the operating parameter settings showed 93.4 dB(A) in 3 dB of exchange rate, 80 dB of threshold level and 90dB of criterion level 92.0 dB(A) in 3 dB-exchange rate, 90 dB-threshold level and 90 dB-criterion level, in 90.8 dB(A) in 5 dB of exchange rate, 80 dB of threshold level and 90 dB of criterion level, and 86.7 dB(A) in 5 dB of exchange rate, 90 dB of threshold level and 90dB of criterion level. 2. ln group of noise level less than 90 dB(A), mean TWAs of 80 dB of threshold level were significantly higher than that of 90 dB of threshold level in 3 dB and 5 dB of exchange rate. 3. The case exceeded threshold limit value of noise was 49(61.3 %) in 3dB, 80dB and 90 dB setting, 44(55.0 %) in 3 dB, 90 dB, 90 dB setting, 33(41.3 %) in 5 dB, 80dB, 90 dB setting and 26(32.5%) in 5 dB, 90 dB, 90 dB setting. Above considerations in mind, it is suggested that exchange rate and threshold level be specified in related laws and regulations in the evaluation of working environments noise.

  • PDF

The Correlation Between Speech Reception Threshold and Pure Tone Audiometry (어음청취역치와 순음청력검사의 상관관계에 관한 연구)

  • 이철희;선우대활;민양기;백만기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.2-39
    • /
    • 1981
  • Speech reception threshold is a base for word discrimination testing, but it also serves as a check for the reliability of pure tone audiogram. In order to investigate the correlation between SRT and PTA these tests were carried out in patients with conductive hearing loss and normal hearing, using Grason-Stadler 1702 Audiometer. The results were as follows; 1) The difference between the scores of SRT and PTA's was 2.4 dB with a range of -3.3 dB∼+8.3 dB in conductive hearing loss, and was 1.9 dB with a range of -6.7 dB∼+5 dB in normal hearing group. 2) The difference between the scores of SRT and each speech frequency of PTA was 6 dB at 500 Hz, 3 dB at 1,000 Hz and 8.8 dB at 2,000 Hz in conductive hearing loss, and 3 dB at 500Hz, 2 dB at 1,000Hz, and 5dB at 2,000Hz in normal hearing group.

  • PDF

dB-Linear CMOS Variable Gain Amplifier for GPS Receiver (dB-선형적 특성을 가진 GPS 수신기를 위한 CMOS 가변 이득 증폭기)

  • Jo, Jun-Gi;Yoo, Chang-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.7
    • /
    • pp.23-29
    • /
    • 2011
  • A dB-linearity improved variable gain amplifier (VGA) for GPS receiver is presented. The Proposed dB-linear current generator has improved dB-linearity error of ${\pm}0.15$dB. The VGA for GPS is designed using proposed dB-linear current generator and composed of 3 stage amplifiers. The IF frequency is assumed as 4MHz and the linearity requirement of the VGA for GPS receiver is defined as 24dBm of IIP3 using cascaded IIP3 equation and the VGA satisfies 24dBm when minimum gain mode. The DC-offset voltage is eliminated using DC-offset cancelation loop. The gain range is from -8dB to 52dB and the dB-linearity error satisfies ${\pm}0.2$dB. The 3-dB frequency has range of 35MHz~106MHz for the gain range. The VGA is designed using 0.18${\mu}m$ CMOS process. The power consumption is 3mW with 1.8V supply voltage.

Design of MMIC SPDT Switches in the ISM Band Using GaAs MESFETs (GaAs MESFET를 이용한 ISM 대역 MMIC SPDT 스위치 설계)

  • Park, Hun;Yun, Kyung-Sik;Ji, Hong-Koo;Kim, Hae-Cheon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.3A
    • /
    • pp.179-184
    • /
    • 2003
  • In this paper, an asymmetric topology of MMIC SPDT switch was proposed to increase the isolation in the receiving path and decrease the insertion loss with higher P1dB in the transmitting path for the ISM band. This SPDT switch was implemented with 0.5㎛ GaAs MESFETs processed by ETRI for the IDEC MPW project. For the receiving path the measured insertion losses were 1.518dB at 3GHz and 1.777dB at 5.75GHz and the isolations were 38.474dB at 3GHz and 29.125dB at 5.75GHz. For the transmitting path the insertion losses were 0.916dB at 3GHz and 1.162dB at 5.75GHz and the isolations were 23.259dB at 3GHz and 16.632dB at 5.75GHz. Compared to the symmetric topology the isolations of the receiving path for the asymmetric one were improved by 15.9dB at 3GHz and 11.9dB at 5.75GHz and its insertion loss was increased by about 0.6dB. In addition, P1dB of 21.5 dBm for the transmitting path was obtained, which is increased by 3.86dB compared to the symmetric one.

Study on the UHF-band Variable Attenuator Using the 3-dB Coupler (UHF대역 3-dB 커플러(Coupler)를 이용한 가변 감쇄기(Attenuator)에 대한 연구)

  • 박경태
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.2
    • /
    • pp.68-74
    • /
    • 2001
  • A design and implementation method for the UHF-band(800MHz) variable attenuator using the 3dB coupler is proposed. The 90 degree, 3-dB Coupler is used for the variable attenuator. The principal theory for the 3-dB coupler is introduced. The 3-dB Coupler is designed by the mathematical analysis and a computer simulation tool. A PIN diode is used for the variable resistor at UHF-band. The variable attenuator using the 3-dB coupler and the PIN diode is designed and implemented. The measured results for the variable attenuator by a network analyzer show that the insertion loss is below -l0dB, and the continuous variable attenuation range is about 10dB.

  • PDF

Development of Combinational 2-Way Isohybrid for GSM1900 Base Station (GSM1900 기지국용 일체형 2-Way Isohybrid의 개발)

  • Park, Noh-Joon;Jung, Seung-Woo;Kang, Young-Jin;Choi, U-Sung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1415-1423
    • /
    • 2007
  • Total efficiency of transmitter system was improved by developing combinational 2-Way Isohybrid for GSM1900 base station in this paper. The size of product was decreased and the characteristics were stabilized. The isohybrid transmitter combiner of chip coupler type and hybrid coupler type were designed and fabricated. Insertion loss for chip coupler type isohybrid was $3.17\;dB{\sim}3.47\;dB$. On the other hand, insertion loss for hybrid coupler type was $3.17\;dB{\sim}3.42\;dB$. Isolations between ANT and port were $24.23\;dB{\sim}29.98\;dB$ in case of chip coupler type Isohybrid and were $26.28\;dB{\sim}36.91\;dB$ in case of hybrid coupler type, respectively.

THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms- (선박소음에 관한 연구 -방음실에 의한 소음제어효과실험-)

  • PARK Jung-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 1976
  • In this study, noise arresting effect of the noise control room from the transmission of surrounding noise was tested when the packing noise control rooms were set up in the test room in which the prerecorded noise from an engine room was reradiated at the same level as the original pressure. The inner space of control room A is $3.389m^3(1.19\times1.19\times2.14m)$ having walls furnished with plywood board 9mm in thickness and noise control room door$(60\times45cm) $ and illumination lamp are placed. In case of the control room B, noise absorption board(10mm fiber board which holds the corntype concavity with diameter of 5mm, depth 5mm, space 15mm) is adhered to the internal ceiling and styrol foam boards(20mm) to the walls. The other struction is same as the control room A. Type C is the same as B except wool board(Glass Fiber, 33mm) on the walls. Type D is same as type A except that the thickness of wall is 12mm and wood pyramid type cone$(5\times5\times13cm)$ is adhered to the ceiling ana walls(Fig. 1). When the recorded noise and vibrated noise were controlled in various levels. The noise pressure which passed through the control rooms was measured by sound level meter(Bruel & Kjar 2205, measuring range 37-140dB). In order to calculate the absorption rate in the control rooms the noise pressure was measured at different distances when the recorded noise pressure was radiated. The followings are the results obtained from the experiment. 1. When the noise pressure of the test room was 60dB, transmission rate of type A was $69.7\%$ and increased $3.3\%$ per 10dB. At the same condition, the rate was $53.9\%$ and increased $4.5\%$ per 10dB in type D. Type D was the most effective in noise arresting of the four and the effect was D,C,B and A in order(Fig.2). 2. When the oscillator sound and vessels noise were radiated in 1,000Hz, at one meter distance to the type A and D, the oscillator sound pressure were 77dB and 73dB, while the vessels noise pressure were 73.3dB and 66.2dB respectivley(Fig.3). 3. Refering to the influence of the frequency to the lower oscillator sound(1,000Hz) pressure, both type C and D were almost same at 140cm but type C was 0.3dB lower than type D at 20cm distance(Fig.4).

  • PDF

Parameter Analysis for Receiving System of Digital Mobile Communication (디지털 이동통신의 수신 시스템에 대한 파라미터 분석)

  • 주재한
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.7
    • /
    • pp.895-904
    • /
    • 2001
  • In this study, gain can be high because an active double balance mixer was used. Receiving system II was made with receiving system I of low IIP3, a passive double balance mixer which has low gain and high IIP3, and an intermediate frequency amplifier for enhancing the low gain. The result of simulating receiving parameter is as follows: the total NF of receiving system I was 6.4382dB, gain was 53.5dB, and IIP3 was -6.6352dB m. As for the receiving system II, the total NF was 9.70672dB, gain was 47dB, and IIP3 was 3.66729dB m.

  • PDF

Allelic Variation of Glutenin, Granule-Bound Starch Synthase l and Puroindoline in Korean Wheat Cultivar

  • Park, Chul-Soo;Pena, Roberto J.;Baik, Byung-Kee;Kang, Chon-Sik;Heo, Hwa-Young;Cheong, Young-Keun;Woo, Sun-Hee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.54 no.2
    • /
    • pp.181-191
    • /
    • 2009
  • To investigate the genetic variation of high-and low-molecular-weight glutenin subunits (BMW-GS and LMW-GS), granule-bound starch synthase I (GBSSI) and puroindoline in 24 Korean wheat cultivars. At the BMW-GS compositions, three Glu-A1 alleles, five Glu-B1 alleles and three Glu-D1 alleles were identified. The high frequency of alleles at each locus was Glu-A1c allele (15 cultivars), Glu-B1b allele (16 cultivars) and Glu-D1f allele (16 cultivars). Four alleles were identified at the Glu-A3 and Glu-B3 loci and three at Glu-D3 locus and Glu-A3d, Glu-B3d and Glu-D3a were mainly found at each Glu-3 locus. Glu-A3d, Glu-B3d, Glu-D3b or c (4 cultivars, respectively) and Glu-A3d, Glu-B3d, Glu-D3a and Glu-A3c, Glu-B3d or h, Glu-D3a (3 cultivar, respectively) were predominantly found in Korean wheats. At the GBSS compositions, 2 waxy wheat cultivars, Shinmichal and Shinmichal1, showed null alleles on the Wx loci and other cultivars were wild type in GBSS compositions. At the puroindoline gene compositions, Korean wheat cultivars carried 3 genotypes, which 10 cultivars (41.7%) were Pina-D1a and Pinb-D1a, 11 cultivars (45.8%) had Pina-D1a and Pinb-D1b and 3 cultivars (12.5%) carried Pina-D1b and Pinb-D1a. These genetic variations could present the information to improve flour and end-use quality in Korean wheat breeding programs.

Fixed Biased 4-D Multiple-Subcarrier Signal for Average Power Reduction in Optical Wireless Communication (Fixed bias를 가지는 4-D Multiple-Subcarrier 신호를 이용한 Optical Wireless 통신의 평균 전력 절감에 관한 연구)

  • 김해근
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.10
    • /
    • pp.103-109
    • /
    • 2003
  • We have proposed the 4-Dimensional Multiple-Subcarrier Modulation with fixed bias in Optical Wireless Communications. Here, the 4-D signal vectors are derived from the optimization technique of signal waveforms maximizing the minimum distance between signal points in an n-dimensional Euclidean sphere. The resulting vectors are used in generating the output amplitude of impulse generator in a Multiple-Subcarrier Modulation scheme. We have achieved that the normalized power requirement of the proposed system is maximum 3 dB and 3.3 dB smaller than those of normal QPSK, Reserved Subcarrier, and Minimum Power scheme, respectively. Also, in the range of 1.125 ∼ 1.25 of the normalized bandwidth, the proposed system has maximum 3 dB, 2 ∼ 4 dB, 0 ∼ 3 dB smaller bandwidth requirement compare to normal QPSK, Res. Subcarrier, Min. Power schemes, respectively.