• Title/Summary/Keyword: 3X scope

Search Result 49, Processing Time 0.034 seconds

Development of 3X Scope with Objective Configured with Doublet+Meniscus Lens (더블렛+메니스커스렌즈 대물부를 가지는 3X 스코프 개발)

  • Lee, Dong-Hee;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.487-492
    • /
    • 2014
  • Purpose: This study relates to the development of the 3X scope, whose objective part is configured with a doublet + a meniscus lens. Methods: By the initial condition of the objective part having a configuration of a doublet + a singlet, we could optimize the optical system of scope in order to minimize the finite ray aberrations of the objective part and the whole optical system of scope, and so we could develope a new type 3X scope. Results: On the condition of the objective part having a configuration of a doublet + a singlet, when the optical system of scope was optimized in order to minimize the finite ray aberrations, we could find that the singlet became the meniscus type lens having the concave shape to the direction of the doublet, and the longer the distance between the doublet and the meniscus lens is, the more the finite ray aberrations are minimized. Conclusions: In this study, we could develope a new type 3X scope of which finite ray aberrations can be reduced to 1/14 than the existing scope by adopting the objective part of the 3X scope having a configuration of three lenses composed of a doublet + a singlet. We could confirm that this reduction of aberrations can be a means to increase the effective aperture than the existing scope and to shorten the length of the optical system.

Developement of Scope for Military Rangefinder Using Schmidt Prism and Biprism Theory of Optometric Instrument (안광학기기에 사용되는 바이프리즘원리와 슈미트 프리즘을 이용한 군사 거리측정기용 스코프 개발)

  • Cha, Jung-Won;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.167-175
    • /
    • 2015
  • Purpose: The new-type rangefinder, which is using the biprism principle, is introduced to develop the range finder which can be easily carried by soldiers, and in order to realize those technologies specifically, we try to develop a scope for military rangefinder by doing optical design which can secure enough space to move the biprism. Methods: After setting up the verious initial condition to realize two kinds of goals, that are the securement of enough space to move the biprism and the easy-exchangeability of two kinds of biprisms, and then the optical system was optimized by using optical design program CodeV in order to minimize the finite ray aberrations. Results: We designed the biprism housing to makes it possible to swap the two kinds of biprisms. It was appeared that the Schmidt prism is suitable as erecting prism which can make sure the space to move the biprism. 16.5 mm was good for the face length of Schmidt prism. The optical system with a Schmidt prism and a biprism was designed, and the finite ray aberrations was minimized. Conclusions: We developed a 5X scope for an optical rangefinder using a biprism and a Schmidt prism with 16.5 mm face length. This scope is valid for the optical system which has the effective field angle of ${\pm}3.6^{\circ}$, and the finite ray aberrations are well controlled within the ${\pm}8.95^{\prime}$.

Development of Day and Night Scope with BS Prism (BS 프리즘을 이용한 주야 조준경 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • Purpose: This study relates to the development of the day and night scope using the reflecting surface of a BS (beam splitting) prism. Methods: We have placed the LCD panel and the dot reticle generator to the top and bottom of the reflecting surface of the BS prism, and have placed a reflector, which is designed to doublet type, in the front of the BS prism. Doing so, we have developed a new type of day and night scope, which is able to image the virtual image of dot reticle from the dot reticle generator to the direction of the observer, to make the observer survey the peripheral information of the outside target by 1x magnification, and to make the observer survey the image of the LCD panel directly. Results: We could develope a new type of day and night scope, which has the function of night scope as thermal image display device at night time and the function of day scope as dot sight at day time, by letting the reflective surface of the BS prism have the role of dot sight which reflects the dot reticle and have the role of reflective optical system by which the observer surveys the night thermal image displayed in LCD panel. Conclusions: In this study, we have developed the new type of day and night scope which is able to play the role of the day or night scope selectively, combining the existing dot sight and the existing night scope by using the BS prism. By doing so, we could design and fabricate the new type of day and night scope with the BS prism which can further increase the rapidity of firing and provide more convenience in the mounting of a firearm than the detachable combination of an existing dot sight and an existing night scope.

Introduction to Qunatification of Damage Parameters for Concrete Using X-ray Computed Tomography (X-ray Computed Tomography를 이용한 콘크리트의 손상파라미터 정량화)

  • 박대효;박재민;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.501-504
    • /
    • 2003
  • The purpose of this work is to introduce some fundamental stereological concepts to quantify damage parameters using X-ray CT(Computed Tomography) in the scope of CDM(Continuum Damage Mechanics). X-ray CT is a completely nondestructive technique for visualizing features in the interior of opaque solid objects, and for obtaining digital information on their 3D geometries and properties. Many researchers have introduced lots of damage parameters to model the mechanical behavior of deteriorated materials. Those damage parameters can be represented in many forms such as specific void or crack surfaces, the spacing between cracks, the specific damaged surface area, the specific damaged surface area tensor, the mean solid path among the damaged surfaces and the mean solid path tensor. Despite of many accomplishments in CDM since there is no the systematic experiment, it have limitations in application. In this situation, X-ray computed tomography is highlited by many researchers and applied in a wide range of materials including rock, bone, ceramic, metal, soft tissue and concrete.

  • PDF

Design of 1× Optical Path Relay Adapter for Beam Splitting Prism used in Day & Night Scope (주야 관측경용 빔 분리프리즘을 위한 1× Optical Path Relay Adapter 설계)

  • Lee, Dong-Hee;Choi, Gyu-Jung;Jung, In;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.441-447
    • /
    • 2012
  • Purpose: This paper is about development and design of the 1x optical path relay adapter for the beam splitting prism by us the day & night scope. Methods: To product the day & night scope by using the beam splitting prism and the commercial zoom optical system with the C-mount lens barrel structure, the optical path relay adapter, which doesn't change the image size of the zoom optical system and can stretch the position of the image-forming surface, is needed. We could design the 1x optical path relay adapter by using the CodeV program in which the Lens Module mode is offered. Results: We could design the optical path relay adapter used in the day&night scope with the beam splitting prism, of which characteristics have the EFL of -56.0 mm, the magnification of +1.0x, the distance from the 1st lens surface to the last lens surface of about 20.4 mm. The resolution of this system is characterized by 30 lp/mm at 40% MTF. This is enough to accommodate the designed optical path relay adapter can overcome the resolution of the 3rd generation of image intesifier tubes. Conclusions: By designing and applying the optical path relay adapter of which optical characteristics have the EFL of -56.0 mm, the magnification of +1.0x, the distance from the 1st lens surface to the last lens surface of about 20.4 mm, and the resolution of 30 lp/mm at 40% MTF, we could develop the new type day&night scope consisting of the beam splitting, the commercial zoom optical system with the C-mount lens barrel structure, and the 3rd generation of image intesifier tubes.

A Study on the Range of Color Preception in Primary Colors (1차색의 지각범위에 관한 연구)

  • 이정옥;정용희;이순자
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.7-13
    • /
    • 1999
  • The purpose of this study was to suggest the c1ata which were useful to apply the color for clothes resign 29 female university students were se10cted in this experirrental study for the perception scope of primroy color from July to Dec. in 1998. The results of this study are as the following : 1) The perception scope of red perceived by more than 30% of the subjects was wider in Chroma-axis than in Value-axis, including 5R 4/12, 5R 4/10 and 5R 5/14 in standard color 5R standard color 5R 4/14. The perception scope of yellow was wider in Chroma-axis in standard color 5Y 8/14. And the perception scope of blue was wider in Value-axis in standard color 5B 4/10. 2) In chromaticity diagram, the perception scope of red perceived by one subjoct and over was large, covering three-quarters and being extended in X -axis. The perception scope of yellow was awuximately a half, without being linked together. A few of it were separated. And the perception scope of blue was about two-thirds, including all color chips in the line. In conclusion, the perception scope of red was comprehensively broad and there aweared relatively strong corrnron feature between the subjects. The perception scq;e of yellow was awuximate1y a half and there was little cormnon feature between the subjects. And the perception sccpe of blue was sorrewhat wide and the sUbiects expressed strong cornrmn feature. feature.

  • PDF

Plastic Collapse Solution for API 5L X65 Natural Gas Linepipe (천연가스 수송용 API 5L X65 배관에 대한 소성붕괴해)

  • Kim Woo-sik;Shim Do-jun;Choi Jae-boong;Baek Jong-hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.10
    • /
    • pp.1483-1491
    • /
    • 2004
  • To assess the integrity of the pipeline is the most important problem to be solved first of all for prevention of any fracture accident of the pipeline. As a result of exerting such efforts, a number of plastic collapse assessment equations have been suggested, however, the scope of using or applying such assessment equations has not been exactly defined. In this study, the case that a surface crack existed in the circumferential direction in the external side of the natural gas pipeline and a bending load was applied to the pipeline was analytically identified as the most critical condition, and a plastic collapse assessment equation fur it was suggested. The flow stress of the API X65 linepipe was defined through the experiment conducted on SENT specimens. Also, a local assessing criterion of a 3-dimensional crack behavior considering not only the crack depth but also the crack length was suggested. Finally, a plastic collapse assessment equation for the API X65 linepipe was developed by performing the 3-dimensional finite element analysis.

A study on the digital image transfer application mass chest X-ray system up-grade (간접촬영기의 디지털 영상 변환 장치 적용에 대한 연구)

  • Kim, Sun-Chil;Park, Jong-Sam;Lee, Jon-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.13-17
    • /
    • 2003
  • By converting movable indirect mass chest X-ray devices for vehicles into digital systems and upgrading it to share information with the hospital's medical image information system, excellencies have been confirmed as a result of installing and running this type of system and are listed hereinafter. 1. Upgrading analog systems, such as indirect mass chest X-ray devices dependent on printed film, to digital systems allows them to be run and managed much more efficiently, contributing to the increase in the stability and the efficiency of the system. 2. Unlike existing images, communication based on DICOM standards allow images to be compatible with the hospital's outer and inner network PACS systems, extending the scope of the radiation departments information system. 3. Assuming chest-exclusive indirect mass chest X-rays, a linked development of CAD (Computer Aided Diagnosis, Detector) becomes possible. 4. By applying wireless Internet, Web-PACS for movable indirect mass chest X-ray devices for vehicles will become possible. Research in these fields must continue and if the superior image quality and convenience of digital systems are confirmed, I believe that the conversion of systems still dependent on analog images to modernized digital systems is a must.

  • PDF

이온빔 스퍼터를 이용한 산화물박막 제조 및 구조적특성 분석

  • Yu, Byeong-Yun;Bin, Seok-Min;Kim, Chang-Su;O, Byeong-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.82-82
    • /
    • 2011
  • 본 연구에서는 이온빔 스퍼터링 방법으로 증착한 Cr2O3, Ta2O5, HfO2 산화물박막의 구조적 특성변화를 관찰하였다. 금속박막에서 표면이 산화되는 문제를 해결하기위하여 산화물 박막을 증착시켰다. 이온빔 스퍼터링으로 박막 증착 시 산화물 타겟을 사용할 때 발생되는 전하의 영향을 상쇄하기 위하여 neutralizer를 사용하였다. 박막 증착 후 XRR (X-ray Reflectometer)을 이용하여 박막의 두께, 거칠기 및 밀도를 확인하였으며, AFM (Atomic Force MicroScope)을 통하여 증착한 박막표면 거칠기 측정을 하여 XRR로 얻은 데이터와 비교하여 살펴보았다. 또한 XPS (X-ray photoelectron spectroscopy)측정을 통해 제조된 박막의 화학적 결합상태를 확인하였다. 여러 가지 조건변화와 기판의 차이에 따라 제작된 산화물 박막 중 실리콘 기판을 사용하여 증착시킨 박막은 XRR측정시 반사율 곡선에서 자연 산화막에 의한 영향이 나타났다. 반면 glass나 sapphire에 증착시킨 산화물 박막은 실리콘기판에서 나타난 자연 산화막의 영향을 받지 않음을 확인하였다. 기판과 산화물 박막사이에 계면층에 나타나는 영향을 최소화시킴으로써 양질의 박막을 제작할 수 있을 것으로 기대된다.

  • PDF

Study on the Design System based on the Interior Space Composition Factors of Apartment Housing (아파트 내부 공간 구성 요소에 의한 디자인 시스템에 관한 연구)

  • 정재욱;윤미라
    • Korean Institute of Interior Design Journal
    • /
    • no.27
    • /
    • pp.35-42
    • /
    • 2001
  • The main scope of this study is to define such system of space composition factor to diversify the interior space of the apartment housing. Staring from the space analysis, identification of the design factors, characters of the anthropometry for the dwelling behavior, and analyzed dimensions of the interior furniture from the market data have uniformly integrated to engage with such system for innovation and diversification of the space design method. The elements of the composition factors are as follows: 1. Structural elements - $\circled1$Bearing wall $\circled2$Ceiling $\circled3$Floor $\circled4$Structural column 2. furniture elements - $\circled1$Fixed furniture $\circled2$Movable furniture $\circled3$Non-bearing wall $\circled4$F1exible wall $\circled5$Void & Solid 3. Finished material elements - $\circled1$Structural material $\circled2$Doub1e shell $\circled3$Color & Tone $\circled4$Lighting system For the design system selected space in restricted in 3way directional axis X,Y,Z to form its volume and direction of the space composition factors. X-axis is stands for horizontal length of the factor, Y-axis is for the space depth, and lastly, Z-axis is for the hieghts of the space based on anthropometris.

  • PDF