• Title/Summary/Keyword: 3T MRI System

Search Result 196, Processing Time 0.024 seconds

A fMRI study on the cerebral activity induced by Electro-acupuncture on Zusanli(St36) (족삼리(足三里)(St36)의 전침자극(電鍼刺戟)이 fMRI상 뇌활성(腦活性) 변화(變化)에 미치는 영향(影響))

  • Kim, Young-il;Kim, Young-hwa;Lim, Yun-kyoung;Lee, Hyen;Lee, Byung-ryul;Kim, Yeon-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.5
    • /
    • pp.133-150
    • /
    • 2003
  • Objective: Recently. many studies have showed the evidences of the effect of the Electro-acupuncture treatment through scientific. Methods : One of these methods is functional MRI. We performed electro-acupuncture on Zusanli(St36) and observed the change of brain activation using fMRI. Zusanli(St36) is located on the lateral side of the lower leg. 3 cun(寸) inferior to the Patella of the lower border. Theoretically and clinically. this point has been considered very important for gynecological disorders. spleen and stomach disorders. and psychological disorders. To see the effects of electro-acupuncture stimulation on Zusanli(St36). the experiment was carried out on twelve healthy volunteers. using the gradient echo sequence with the 3.0T whole-body fMRI system(ISOL). After the needle insertion on right Zusanli(St36). 2 Hz of electric stimulation was given for 30 seconds. repeated five times. with 30 seconds' intervals. The Image analysis including motion correction. talairach transformation, and smoothing was done with SPM99. Results ad conclusion : The electro-acupuncture stimulation on Zusanli(St36) activates Brodmann Area 6, 13, 2, 19, 21, 22, 39, 40, 38, 3which indicates the pathways of the electro-acupuncture stimulation on Zusanli(St36) and the possibility of the relationship of the electro-acupuncture stimulation on Zusanli(St36) with autonomic nervous system, internal organic system.

  • PDF

Tumor volume/metabolic information can improve the prognostication of anatomy based staging system for nasopharyngeal cancer? Evaluation of the 8th edition of the AJCC/UICC staging system for nasopharyngeal cancer

  • Jeong, Yuri;Lee, Sang-wook
    • Radiation Oncology Journal
    • /
    • v.36 no.4
    • /
    • pp.295-303
    • /
    • 2018
  • Purpose: We evaluated prognostic value of the 8th edition of the American Joint Committee on Cancer/International Union for Cancer Control (AJCC/UICC) staging system for nasopharyngeal cancer and investigated whether tumor volume/metabolic information refined prognostication of anatomy based staging system. Materials and Methods: One hundred thirty-three patients with nasopharyngeal cancer who were staged with magnetic resonance imaging (MRI) and treated with intensity-modulated radiotherapy (IMRT) between 2004 and 2013 were reviewed. Multivariate analyses were performed to evaluate prognostic value of the 8th edition of the AJCC/UICC staging system and other factors including gross tumor volume and maximum standardized uptake value of primary tumor (GTV-T and SUV-T). Results: Median follow-up period was 63 months. In multivariate analysis for overall survival (OS), stage group (stage I-II vs. III-IVA) was the only significant prognostic factor. However, 5-year OS rates were not significantly different between stage I and II (100% vs. 96.2%), and between stage III and IVA (80.1% vs. 71.7%). Although SUV-T and GTV-T were not significant prognostic factors in multivariate analysis, those improved prognostication of stage group. The 5-year OS rates were significantly different between stage I-II, III-IV (SUV-T ≤ 16), and III-IV (SUV-T > 16) (97.2% vs. 78% vs. 53.8%), and between stage I, II-IV (GTV-T ≤ 33 mL), and II-IV (GTV-T > 33 mL) (100% vs. 87.3% vs. 66.7%). Conclusion: Current anatomy based staging system has limitations on prognostication for nasopharyngeal cancer despite the most accurate assessment of tumor extent by MRI. Tumor volume/metabolic information seem to improve prognostication of current anatomy based staging system, and further studies are needed to confirm its clinical significance.

Development of TEM Coil for Animal Experiments at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.365-366
    • /
    • 2002
  • A novel TEM resonator coil was developed for the imaging of small animals. The functional elements of the TEM resonator were 8 inner conductors, distributed in a cylindrical pattern and connected at the ends with capacitors to the cylindrical outer shield. The TEM resonator coil with cavity elements was robust to the surrounding influences due to the self-shielding structure. The TEM resonator coil with high Q factor could provide high quality MR images at 3.0T MRI system. Also, the TEM resonator coil has an advantage for a fine tune with length adjustment of each cavity elements. Thus, The TEM resonator coil at 3.0T, even higher field could be used in the research studies.

  • PDF

Development of Solenoid RF Coil for Animal Imaging in 3T High Magnetic Field MRI (고자장 3T MRI 장비에서 동물영상을 위한 솔레노이드 RF코일 개발)

  • Lee, Hong-Seok;Woo, Dong-Cheol;Min, Kwang-Hong;Kim, Yong-Kwon;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.20-26
    • /
    • 2007
  • Purpose : The purpose of the present study was to develop and optimize solenoid coil for animal- model in 3 T MRI system and investigate and compare with the birdcage coil concerning the image quality with the various parameters such as SNR and Q-factor. Materials and Methods : Solenoid coil for animal-model was made on the acryl structure (diameter 4 cm, length 10 cm) 3 times-winding cooper tape of width 2 cm, thickness 0.05 cm and length 10 cm with 2 cm interval between winded tapes. Capacitors from 2 pF to 100 pF were used, and the solenoid coil was designed for receiver only coil. Results : SNR of the developed solenoid was 985 in CuSO4 0.7 g/L and 995 in rat experiment. Q-factor was 84-89 in unloaded condition and 203-206 in loaded condition. Conclusion : The resolution of the image obtained from solenoid was relatively higher than that of the conventional birdcage coil. In addition, the homogeneity of RF field by coil simulation was significantly excellent. The present study demonstrated that the solenoid coil could be useful to obtain small animal images with better contrast, resolution, visibility than images from birdcage.

  • PDF

MRI-guided Wire Localization Open Biopsy is Safe and Effective for Suspicious Cancer on Breast MRI

  • Wang, Hai-Yi;Zhao, Yu-Nian;Wu, Jian-Zhong;Wang, Zheng;Tang, Jing-Hai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1715-1718
    • /
    • 2015
  • Background: Magnetic resonance imaging of breast, reported to be a high sensitivity of 94% to 100%, is the most sensitive method for detection of breast cancer. The purpose of this study was to investigate our clinical experience in MRI-guided breast lesion wire localization in Chinese women. Materials and Methods: A total of 44 patients with 46 lesions undergoing MRI-guided breast lesion localization were prospectively entered into this study between November 2013 and September 2014. Samples were collected using a 1.5-T magnet with a special MR biopsy positioning frame device. We evaluated clinical lesion characteristics on pre-biopsy MRI, pathologic results, and dynamic curve type baseline analysis. Results: Of the total of 46 wire localization excision biopsied lesions carried out in 44 female patients, pathology revealed fourteen malignancies (14/46, 30.4%) and thirty-two benign lesions (32/46, 69.6%). All lesions were successfully localized followed by excision biopsy and assessed for morphologic features highly suggestive of malignancy according to the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) category of MRI (C4a=18, C4b=17, C4c=8,C5=3). Of 46 lesions, 37 were masses and 9 were non-mass enhancement lesions. Thirty-two lesions showed a continuous kinetics curve, 11 were plateau and 3 were washout. Conclusions: Our study showed success in MRI-guided breast lesion wire localization with a satisfactory cancer diagnosis rate of 30.4%. MRI-guided wire localization breast lesion open biopsy is a safe and effective tool for the workup of suspicious lesions seen on breast MRI alone without major complications. This may contribute to increasing the diagnosis rate of early breast cancer and improve the prognosis in Chinese women.

Comparison of Image Quality in Magnetic Resonance Imaging of the Abdominal Organ at 1.5T and 3.0T before the Gadolinium Injection (조영제 주입 전 1.5T 와 3.0T를 이용한 복부장기 자기공명영상에서 영상의 질 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.619-625
    • /
    • 2017
  • The sudy was intended to evaluate the optimal equipment selection by quantitatively assessing the SNR(signal to noise ratio) and CNR(contrast to noise ratio) on the abdominal organ. This study performed on 1.5 T and 3.0 T MRI units focusing on HASTE, HASTE(f/s) and FFE(in of phase), FFE(out of phase) without using the contrast medium(Gadolinium). The data analysis was performed by randomly selecting on 1.5 T and 3.0 T abdominal MRI images. As a results, SNR and CNR values of 3.0 T is higher than 1.5 T at liver, kidney and spleen(p<0.05). Stomach, abdominal fat and pancreas was obtained a higher value at 1.5 T(p<0.05). On conclusion, the organs of outer part in the body showed generally a high value at 3.0 T, and the organs of inner part in the body including the gas showed a high value at 3.0 T because of a large difference on magnetic susceptibility.

Feasibility Study of Applying the Acrylic Assistant Equipment (ACR) to Reduce Patient's Discomfort in Lower Abdomen MRI Scan (하복부 MRI 검사 시 환자의 불편함을 줄이기 위한 아크릴 보조 장치 사용의 타당성 조사)

  • Park, Eunhye;Lee, Minsik
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.475-480
    • /
    • 2018
  • In lower abdominal MRI scan, patients have been tested by physically contacting with the body array coil. In this study, we have designed the acrylic assistant equipment (ACR) which allows the contactless scan of the patient to the coil and evaluated the feasibility by comparing the acquired images with ACR to those obtained without ACR. We tested 10 cases (F: 5, m: 5) by using the Ingenia $3.0T^{TM}$ MR system and dStreamTM torso coil (Philips Healthcare, Netherlands). We implemented T1 AX TSE and eTHRIVE (GRE) techniques. The scanned images were quantitatively and qualitatively assessed. In qualitatively, the TSE shows 4.44 and 4.56 mean values with and without the ACR and 4.34 and 4.28 at the GRE, respectively. In quantitatively, the TSE shows 12.15 CNR, 17.95 SNR and 12.71 CNR, 18.96 SNR with and without the ACR. And GRE shows 17.72 CNR, 22.59 SNR and 18.26 CNR, 24.47 SNR with and without the ACR, respectively. We have designed and implemented the acrylic assistant equipment to lower abdominal patients. Our data indicate that it is possible to obtain similar image qualities to current lower abdominal MRI scan without the physical contact to the patient.

A fMRI study on the cerebral activity induced by Electro-acupuncture on Taichong(Liv3) (태충(太衝)(Liv3)의 전침자극(電鍼刺戟)이 fMRI상 뇌활성(腦活性) 변화(變化)에 미치는 영향(影響))

  • Ha, Chi-hong;Lee, Hyun;Lim, Yun-kyoung;Hong, Kwon-eui;Lee, Byung-ryul;Kim, Yeon-jin
    • Journal of Acupuncture Research
    • /
    • v.20 no.5
    • /
    • pp.187-207
    • /
    • 2003
  • Objective: Recently, many studies have showed the evidences of the effect of the acupuncture treatment through scientific methods. One of these methods is functional MRI. We performed electro-acupuncture on Liv3 and observed the change of brain activation using fMRI. Methods: To see the effect of electro-acupuncture stimulation on Liv3. the experiment was carried out on 12 healthy volunteers. using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). After the needle insertion on right Liv3. 2 Hz of electric stimulation was given for 30 seconds. repeated five times. with 30 seconds' intervals. The Image analysis including motion correction, talairach transformation. and smoothing was done with SPM99. Results : 1. Group averaged brain activation induced by bilateral electro-acupuncture stimulation on Liv3 activates Brodman Area 6, 13, 18, 19, 22, 31, 39, 44, 2. Group averaged brain deactivation induced by bilateral Electro-acupuncture stimulation on Liv3 activates Brodman Area 4, 6, 9, 19, 36, 37, 39. 3. Group averaged brain activation induced by unilateral(right side) electro-acupuncture stimulation on Liv3 activates Brodman Area 2, 3, 6, 9, 10, 22, 40, 42, 43. 4. Group averaged brain deactivation induced by unilateral(right side) electro-acupuncture stimulation on Liv3 activates Brodman Area 6, 18, 19, 28, 30, 31, 35, 37. 5. Brain region activated by motor stimulation activates Brodman Area 4, 6, 13, 19, 42.

  • PDF