• Title/Summary/Keyword: 3T MRI System

Search Result 196, Processing Time 0.024 seconds

HIGH QUALITY $^1$H SPECTROSCOPY ON 3.0T MRI

  • Kim, Tae-Yong;Kim, S. Choi;Lee, Heung-Kyu;Park, Jeong-Il;Choe, Bo-Young;Suh, Tae-Suk;Lee, Hyoung-Koo;Shinn, Kyung-Sub
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 1999.11a
    • /
    • pp.172-173
    • /
    • 1999
  • PDF

Use of Imaging and Biopsy in Prostate Cancer Diagnosis: A Survey From the Asian Prostate Imaging Working Group

  • Li-Jen Wang;Masahiro Jinzaki;Cher Heng Tan;Young Taik Oh;Hiroshi Shinmoto;Chau Hung Lee;Nayana U. Patel;Silvia D. Chang;Antonio C. Westphalen;Chan Kyo Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1102-1113
    • /
    • 2023
  • Objective: To elucidate the use of radiological studies, including nuclear medicine, and biopsy for the diagnosis and staging of prostate cancer (PCA) in clinical practice and understand the current status of PCA in Asian countries via an international survey. Materials and Methods: The Asian Prostate Imaging Working Group designed a survey questionnaire with four domains focused on prostate magnetic resonance imaging (MRI), other prostate imaging, prostate biopsy, and PCA backgrounds. The questionnaire was sent to 111 members of professional affiliations in Korea, Japan, Singapore, and Taiwan who were representatives of their working hospitals, and their responses were analyzed. Results: This survey had a response rate of 97.3% (108/111). The rates of using 3T scanners, antispasmodic agents, laxative drugs, and prostate imaging-reporting and data system reporting for prostate MRI were 21.6%-78.9%, 22.2%-84.2%, 2.3%-26.3%, and 59.5%-100%, respectively. Respondents reported using the highest b-values of 800-2000 sec/mm2 and fields of view of 9-30 cm. The prostate MRI examinations per month ranged from 1 to 600, and they were most commonly indicated for biopsy-naïve patients suspected of PCA in Japan and Singapore and staging of proven PCA in Korea and Taiwan. The most commonly used radiotracers for prostate positron emission tomography are prostate-specific membrane antigen in Singapore and fluorodeoxyglucose in three other countries. The most common timing for prostate MRI was before biopsy (29.9%). Prostate-targeted biopsies were performed in 63.8% of hospitals, usually by MRI-ultrasound fusion approach. The most common presentation was localized PCA in all four countries, and it was usually treated with radical prostatectomy. Conclusion: This survey showed the diverse technical details and the availability of imaging and biopsy in the evaluation of PCA. This suggests the need for an educational program for Asian radiologists to promote standardized evidence-based imaging approaches for the diagnosis and staging of PCA.

Assessment of Malignancy in Human Brain Tumors by in vivo 1H MR Spectroscopy at 3 Tesla

  • Choe, Bo-Young;Baik, Hyun-Man;Chu, Myung-Ja;Kwon, Kang-Sei;Chung, Sung-Taek;Oh, Chang-Hyun;Kim, Sun-I;Park, Chi-Bong;Lee, Hyoung-Koo
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.80-80
    • /
    • 2002
  • Purpose: Three tesla high field MR has been important to those disciplines that are SNR limited, such as MR spectroscopy. Additionally, increased spectral dispersion is critical for minimizing spectral overlap and simplifying resonance structures. The purpose of this study was to assess clinical proton MR spectroscopy (MRS) as a noninvasive method for evaluating brain tumor malignancy at 3T high field system Materials and Methods: Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio.

  • PDF

Prognostic Value of Tumor Regression Grade on MR in Rectal Cancer: A Large-Scale, Single-Center Experience

  • Heera Yoen;Hye Eun Park;Se Hyung Kim;Jeong Hee Yoon;Bo Yun Hur;Jae Seok Bae;Jung Ho Kim;Hyeon Jeong Oh;Joon Koo Han
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1065-1076
    • /
    • 2020
  • Objective: To determine the prognostic value of MRI-based tumor regression grading (mrTRG) in rectal cancer compared with pathological tumor regression grading (pTRG), and to assess the effect of diffusion-weighted imaging (DWI) on interobserver agreement for evaluating mrTRG. Materials and Methods: Between 2007 and 2016, we retrospectively enrolled 321 patients (male:female = 208:113; mean age, 60.2 years) with rectal cancer who underwent both pre-chemoradiotherapy (CRT) and post-CRT MRI. Two radiologists independently determined mrTRG using a 5-point grading system with and without DWI in a one-month interval. Two pathologists graded pTRG using a 5-point grading system in consensus. Kaplan-Meier estimation and Cox-proportional hazard models were used for survival analysis. Cohen's kappa analysis was used to determine interobserver agreement. Results: According to mrTRG on MRI with DWI, there were 6 mrTRG 1, 48 mrTRG 2, 109 mrTRG 3, 152 mrTRG 4, and 6 mrTRG 5. By pTRG, there were 7 pTRG 1, 59 pTRG 2, 180 pTRG 3, 73 pTRG 4, and 2 pTRG 5. A 5-year overall survival (OS) was significantly different according to the 5-point grading mrTRG (p = 0.024) and pTRG (p = 0.038). The 5-year disease-free survival (DFS) was significantly different among the five mrTRG groups (p = 0.039), but not among the five pTRG groups (p = 0.072). OS and DFS were significantly different according to post-CRT MR variables: extramural venous invasion after CRT (hazard ratio = 2.259 for OS, hazard ratio = 5.011 for DFS) and extramesorectal lymph node (hazard ratio = 2.610 for DFS). For mrTRG, k value between the two radiologists was 0.309 (fair agreement) without DWI and slightly improved to 0.376 with DWI. Conclusion: mrTRG may predict OS and DFS comparably or even better compared to pTRG. The addition of DWI on T2-weighted MRI may improve interobserver agreement on mrTRG.

Accurate Localization of Metal Electrodes Using Magnetic Resonance Imaging (자기공명영상을 이용한 금속전극의 정확한 위치 결정)

  • Joe, Eun-Hae;Ghim, Min-Oh;Ha, Yoon;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.11-21
    • /
    • 2011
  • Purpose : Localization using MRI is difficult due to susceptibility induced artifacts caused by metal electrodes. Here we took an advantage of the B0 pattern induced by the metal electrodes by using an oblique-view imaging method. Materials and Methods : Metal electrode models with various diameters and susceptibilities were simulated to understand the aspect of field distortion. We set localization criteria for a turbo spin-echo (TSE) sequence usingconventional ($90^{\circ}$ view) and $45^{\circ}$ oblique-view imaging method through simulation of images with various resolutions and validated the criteria usingphantom images acquired by a 3.0T clinical MRI system. For a gradient-refocused echo (GRE) sequence, which is relatively more sensitive to field inhomogeneity, we used phase images to find the center of electrode. Results : There was least field inhomogeneity along the $45^{\circ}$ line that penetrated the center of the electrode. Therefore, our criteria for the TSE sequence with $45^{\circ}$ oblique-view was coincided regardless of susceptibility. And with $45^{\circ}$ oblique-view angle images, pixel shifts were bidirectional so we can detect the location of electrodes even in low resolution. For the GRE sequence, the $45^{\circ}$ oblique-view anglemethod madethe lines where field polarity changes become coincident to the Cartesian grid so the localization of the center coordinates was more facilitated. Conclusion : We suggested the method for accurate localization of electrode using $45^{\circ}$ oblique-view angle imaging. It is expected to be a novelmethodto monitoring an electrophysiological brain study and brain neurosurgery.

Magnetic resonance imaging study of incidental findings in the paranasal sinuses and ostiomeatal complex

  • Yousefi, Faezeh;Mollabashi, Mina;Shokri, Abbas;Tavakoli, Emad;Farhadian, Maryam;Tavakoli, Ali
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • Purpose: This study aimed to assess incidental abnormal findings in the paranasal sinuses and anatomical variations of the ostiomeatal complex (OMC) on magnetic resonance imaging (MRI) scans. Materials and Methods: MRI scans of 616 patients (mean age, 44.0±19.4 years) were evaluated. Prior to obtaining the MRI scans, a checklist of patients' clinical symptoms was filled out after obtaining their consent. The Lund-Mackay classification was used to assess the paranasal sinuses and OMC. The prevalence of abnormal findings and their associations with patients' age, sex, and subjective symptoms were analyzed by the chi-square test, independent-sample t-test, and analysis of variance. The level of significance was set at 0.05. Results: Abnormal findings in the paranasal sinuses were detected in 32.0% of patients, with a significantly higher prevalence in males (P<0.05), but no significant association with age (P>0.05). Epithelial thickening and retention cyst were the most common abnormal findings in the paranasal sinuses. According to the Lund-Mackay classification, 93% of the study population had normal sinuses (score<4). Concha bullosa and paradoxical concha were detected in 15.3% and 3.4%, respectively, with no significant association with the presence of septal deviation or Lund-Mackay classification (P>0.05). Conclusion: Considering the relatively high prevalence of abnormal findings in the paranasal sinuses, it appears that clinical symptoms alone are not sufficient to diagnose sinusitis. A more accurate strategy would be to assess radiographic images of the paranasal sinuses and use a classification system. Sinusitis should be suspected in patients receiving a high score in this classification.

Brain activation pattern and functional connectivity network during classification on the living organisms

  • Byeon, Jung-Ho;Lee, Jun-Ki;Kwon, Yong-Ju
    • Journal of The Korean Association For Science Education
    • /
    • v.29 no.7
    • /
    • pp.751-758
    • /
    • 2009
  • The purpose of this study was to investigate brain activation pattern and functional connectivity network during classification on the biological phenomena. Twenty six right-handed healthy science teachers volunteered to be in the present study. To investigate participants' brain activities during the tasks, 3.0T fMRI system with the block experimental-design was used to measure BOLD signals of their brain. According to the analyzed data, superior, middle and inferior frontal gyrus, superior and inferior parietal lobule, fusiform gyrus, lingual gyrus, and bilateral cerebellum were significantly activated during participants' carrying-out classification. The network model was consisting of six nodes (ROIs) and its fourteen connections. These results suggested the notion that the activation and connections of these regions mean that classification is consist of two sub-network systems (top-down and bottom-up related) and it functioning reciprocally. These results enable the examination of the scientific classification process from the cognitive neuroscience perspective, and may be used as basic materials for developing a teaching-learning program for scientific classification such as brain-based science education curriculum in the science classrooms.

A Review on the RF Coil Designs and Trends for Ultra High Field Magnetic Resonance Imaging

  • Hernandez, Daniel;Kim, Kyoung-Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.95-122
    • /
    • 2020
  • In this article, we evaluated the performance of radiofrequency (RF) coils in terms of the signal-to-noise ratio (S/N) and homogeneity of magnetic resonance images when used for ultrahigh-frequency (UHF) 7T magnetic resonance imaging (MRI). High-quality MRI can be obtained when these two basic requirements are met. However, because of the dielectric effect, 7T magnetic resonance imaging still produces essentially a non-uniform magnetic flux (|B1|) density distribution. In general, heterogeneous and homogeneous RF coils may be designed using electromagnetic (EM) modeling. Heterogeneous coils, which are surface coils, are used in consideration of scalability in the |B1| region with a high S/N as multichannel loop coils rather than selecting a single loop. Loop coils are considered state of the art for their simplicity yet effective |B1|-field distribution and intensity. In addition, combining multiple loop coils allows phase arrays (PA). PA coils have gained great interest for use in receiving signals because of parallel imaging (PI) techniques, such as sensitivity encoding (SENSE) and generalized autocalibrating partial parallel acquisition (GRAPPA), which drastically reduce the acquisition time. With the introduction of a parallel transmit coil (pTx) system, a form of transceiver loop arrays has also been proposed. In this article, we discussed the applications and proposed designs of loop coils. RF homogeneous coils for volume imaging include Alderman-Grant resonators, birdcage coils, saddle coils, traveling wave coils, transmission line arrays, composite right-/left-handed arrays, and fusion coils. In this article, we also discussed the basic operation, design, and applications of these coils.

Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System

  • Lee, Jung-Woo;Choe, Bo-Young;Choi, Chi-Bong;Huh, Soon-Nyoung
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.1
    • /
    • pp.48-60
    • /
    • 2005
  • Purpose: The purpose of this study was to design and build an optimized birdcage resonator configuration with a low pass filter, which would facilitate the acquisition of high-resolution 3D-image of small animals at 3T MRI system. Methods and Materials: The birdcage resonator with 12-element structures was built, in order to ensure B1 homogeneity over the image volume and maximum filling factor, and hence to maximize the signal to noise ratio (SNR) and resolution of the 3-dimensional images. The diameter and length of each element of a birdcage resonator were as follows: (1) diameter 13 cm, length 22 cm, (2) diameter 15 cm, length 22 cm, (3) diameter 17 cm, length 25 cm. Spin echo pulse sequence and fast spin echo pulse sequence were employed in obtaining MR images. The quality of the manufactured birdcage resonators wes evaluated on the basis of the return loss following matching and tuning process. Results: The experimental MR image of phantoms by the various manufactured birdcage resonators were obtained to compare the SNR in accordance with the size of objects. The size of an object to that of coil was identified by parameters that were estimated from the image of a phantom. First, the diameter of the birdcage resonator was 15cm, and the ratio of the tangerine to the birdcage resonator accounted for approximately 27%. The Q factor was 53.2 and the SNR was 150.7. Second, at the same birdcage resonator, the ratio of the orange was approximately 53%. The SNR and the Q parameter was 212.8 and 91.2, respectively. Conclusion: The present study demonstrated that if birdcage resonators have the same forms, SNR could be different depending on the size of an object, especially when the size of an object to that of coil is approximately 40~80%, the former is bigger than the latter. Therefore, when the size of an object to be observed is smaller than that of coil, the coil should be manufactured in accordance with the size of an object in order to obtain much more excellent images.

  • PDF

Magnetic Resonance Imaging of Lumen Wall using Quadrature-typed Inside-out Receiver Coil (회전자계 역수신 코일을 이용한 관벽의 자기공명 영상)

  • 문치웅;조종운
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.385-392
    • /
    • 2001
  • This study Proposes a quadrature-typed inside-out receiver coil to obtain magnetic resonance(MR) images of lumen wall. This means that the coil should receive the signals from out-side of receiver coil. This coil has wide and uniform sensitive region to compare with previous coils such as anti-solenoid coil, octal-pole coil and so on. These coils have the disadvantages that sensitive region is narrow and inhomogenous. The proposed coil is consist of two saddle coils of which directions are orthogonal to one another. The sensitivity maps of octal-Pole coil single-saddle coil and quadrature-typed inside-out coil were obtained by computer simulation. And phantom images for each coil were obtained to evaluate the performances of the coil using both 1.5T superconducting and 0.3 Permanent magnet MRI system. The uniformity of quadrature coil's sensitivity map was superior to that of octal-polel coil. Experimentally measured SNR of quadrature coil is also 36% higher than that of single-saddle coil This study shows the possibility of quadrature-typed inside-out receiver coil for the MR lumen wall images.

  • PDF