• Title/Summary/Keyword: 3MS

Search Result 6,224, Processing Time 0.031 seconds

Determination of superdrol and its metabolites in human urine by LC/TOF-MS and GC/TOF-MS (LC/TOF-MS와 GC/TOF-MS를 이용한 인체 내 요시료 중 Superdrol과 그 대사체의 분석)

  • Choi, Hae-Min;Yum, Tae-Woo;Paeng, Gi-Jeong;Kim, Yun-Je
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.183-192
    • /
    • 2011
  • This study was done for the determination and excretion profile of superdrol and its metabolites in human urine using both liquid chromatography with electrospray ionization mass spectrometry and gas chromatography with mass spectrometry after trimethylsilylation. Superdrol and its two metabolites were detected in human urine after administration of superdrol to healthy volunteers. The intra-day recovery ranged 89.7-113.2%, accuracy ranged 91.8-113.8% and reproducibility ranged 0.2-6.8% and inter-day recovery ranged 89.3-104.1%, accuracy ranged 95.2-103.0%, reproducibility ranged 0.7-7.8%. We found that superdrol M1 was a hydration at C-3 and superdrol M2 was a hydroxylation at D-ring. Superdrol and two metabolites were excreted as their glucuronided fractions. The glucuro-/sulfa-conjugated ratio of superdrol, superdrol M1 and superdrol M2 were 0.02, 0.02, 0.01, respectively. The excretion studies showed that superdrol and two metabolites were reached 4.3 h after oral administration and superdrol and superdrol M1 were detected until 48 h in human urine.

Determination of N-nitrosamines in Water by Gas Chromatography Coupled with Electron Impact Ionization Tandem Mass Spectrometry (EI-GC/MS/MS를 이용한 니트로사민류의 수질분석)

  • Lee, Ki-Chang;Park, Jae-Hyung;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.764-770
    • /
    • 2014
  • This study assessed analysis of N-nitrosamines by separation, identification, and quantification using a gas chromatography (GC) mass spectrometer (MS) with electron impact (EI) mode. Samples were pretreated by a automated solid phase extraction (SPE) and a nitrogen concentration technique to detect low concentration ranges. The analysis results by EI-GC/MS (SIM) and EI-GC/MS/MS (MRM) on standard samples with no pretreatment exhibited similar results. On the other hand, the analysis of pretreated samples at low concentrations (i.e. ng/L levels) were not reliable with a EI-GC/MS due to the interferences from impurity peaks. The method detection limits of eight (8) N-nitrosamines by EI-GC/MS/MS analysis ranged from 0.76 to 2.09 ng/L, and the limits of quantification ranged from 2.41 to 6.65 ng/L. The precision and accuracy of the method were evaluated using spiked samples at concentrations of 10, 20 and 100 ng/L. The precision were 1.2~13.6%, and the accuracy were 80.4~121.8%. The $R^2$ of the calibration curves were greater than 0.999. The recovery rates for various environmental samples were evaluated with a surrogate material (NDPA-$d_{14}$) and ranged 86.2~122.3%. Thus, this method can be used to determine low (ng/L) levels of N-nitrosamines in water samples.

Root Initiation in Cut Italian ryegrass Stems by Treatment of IBA (IBA 처리에 의한 이탈리안 라이그라스 줄기 절단면에서뿌리 분화 유도)

  • 김기용;최기준;성병렬;임용우;박근제;장요순;조진기
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.21 no.1
    • /
    • pp.31-34
    • /
    • 2001
  • When root initiation ratio of cut Italian ryegrass (Lolium multiflorum Lam.) stems was examined in several medium conditions containing different IBA concentration, most higher root initiation ratio was confirmed at 1.0 mg/$\ell$ of IBA and the ratio was 37.5%. When cut Italian ryegrass stems were treated in cold chamber at 4$^{\circ}C$ for 40 days and incubated in growth chamber at 26$^{\circ}C$ for 1 month, the root iniation result was 0.0% at MS-0 medium, 8.3% at MS-0.5IBA medium, 37.5% at MS-1.0IBA medium, 16.7% at MS-1.5IBA medium and 12.5% at MS-2.0IBA medium.

  • PDF

GC/MS and its applications for the analysis of cosmetic produtcts (GC/MS와 화장품 분석의 응용)

  • 노경원
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-19
    • /
    • 1993
  • Gas chromatography serves to separate the mixtures into its components, and mass spectrometer is used to analyzing of unknown compounds. But there are many problems the identification of horn compounds using by GC only. As this reason GC/MS a very powerful analyzing technique. Mass spectrometer consists of 1) inlet stem 2) ion source 3) Bass filter 4) detectors and 5) data system. There are two analyzing modes in the GC/MS, those are scan and SIM(selected ion mom toping) modes. Scan mode is used when analyzing unknown compounds and SIM mode al lows the mass spectrometer to detect specific compound with very high sensitivity. As GC/MS applications for the analysis of cosmetic products, volatile compounds in lotion, earn foundation and hair color, and carbon distribution of fatty acids in soap were performed. Also as a new sample pre-treatment technique, head space sampler/GC/MS introduced in order to analyze the volatile compounds in a toothpaste.

  • PDF

An Association between Factor of Metabolic Syndrome and Serum Levels of Gamma-glutamyltranspeptidse at Age 40 Years

  • Choi, Seok-Cheol;Seok, Seong-Ja
    • Biomedical Science Letters
    • /
    • v.17 no.1
    • /
    • pp.61-68
    • /
    • 2011
  • We have evaluated an usefulness and association between serum levels of gamma-glutamyltranspeptiase (GGT) and metabolic syndrome (MS) in 40-year-old men and women. The prevalence of MS in men (11.8%) was higher than that of women (4.0%). Serum levels of GGT were higher in men and women with MS than in them without MS. In the prevalence of higher serum GGT, men group with MS (35.8%) was greater than women group with MS (22.7%). In the relative risk of MS to an increased level of GGT, women group was higher than men group (about 3 times) (female, OR=7.48 vs male, OR=2.46). The present study reveals that routine check of serum GGT in health examination can be useful for the prevention and management of MS including cardiovascular and/or liver diseases.

Method Development for Determination of Trichothecene Mycotoxins in Nuts by LC-MS/MS (LC-MS/MS를 이용한 견과류 중 트리코테센계 곰팡이 독소 10종 동시분석법 개발)

  • Kim, Dan-Bi;Park, Ji-Su;Yoo, Mi-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.5
    • /
    • pp.354-360
    • /
    • 2018
  • This study presents a method validation for extraction and quantitative analysis of trichothecene mycotoxins in nuts based on quick, easy, cheap, effective, rugged, and safe (QuEChERS) approach for extraction and enhanced matrix removal (EMR)-lipid-disperive-SPE (d-SPE) cleanup method, with detection and quantification by high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) in positive- and negative-ion modes. Linearity, precision, and accuracy were validated for LC-MS/MS methods. Results obtained with LC-MS/MS were linear, with correlation coefficient ($R^2$) of 0.998. Limits of detection and quantification for mycotoxins were $0.41-3.57{\mu}g/kg$ and $1.23-10.82{\mu}g/kg$, respectively. Intra- and inter-day precisions (RSD, %) were 0.40-8.44% and 1.93-12.46%, respectively. Results indicated to be rapidly and accurately identifying trichothecene mycotoxins and may be used as a suitable safety management method for nuts and nuts related commodities.

Simultaneous determination of amphetamine derivatives and norketamine in hair by GC-MS/MS (GC-MS/MS를 이용한 모발 중 암페타민 유도체 및 노르케타민 동시분석)

  • Kim, Jin Young;Shin, Soon Ho;Ko, Beom Jun;Chung, Jae Cheol;Suh, Yong Jun;In, Moon Kyo
    • Analytical Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.210-218
    • /
    • 2009
  • A gas chromatography-tandem mass spectrometry (GC-MS/MS) method was developed and validated for simultaneous determination of amphetamine derivatives and norketamine in human hair. Preparation of hair involves external decontamination, mechanical pulverization, incubation and extraction prior to instrumental analysis. The samples were derivatized using heptafluorobutyric anhydride, and analyzed by GC-MS/MS. The linear ranges were 0.05-20.0 ng/mg for the analytes except for 3,4-methylenedioxyamphetamine, with good coefficients of determination ($r^2$ >0.998). The intra-day and inter-day precisions were within 10.7% and 8.5%, respectively. The intra-day and inter-day accuracies were between -1.6 and 17.0% and -2.6 and 10.5%, respectively. The limits of detections for each analyte were lower than 0.007 ng/mg, while recoveries were 75.9-100.9%. When the method was applied to hair samples obtained from suspected drug abusers, the concentrations in hair samples were 0.97-19.30 ng/mg for methamphetamine and 0.14-2.56 ng/mg for amphetamine.

Determination of Oxycarboxin Residues in Agricultural Commodities Using HPLC-UVD/MS (HPLC-UVD/MS를 이용한 농산물 중 Oxycarboxin의 분석)

  • Choung, Myoung-Gun
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.2
    • /
    • pp.117-124
    • /
    • 2018
  • BACKGROUND: Oxycarboxin(5,6-dihydro-2-methyl-N-phenyl-1,4-oxathiin-3-carboxamide-4,4-dioxide) as oxanthiin is a systemic fungicide commonly used for control of various pathogens in agronomic and horticultural crops. In an effort to develop an analytical method to trace the fungicide, a method using HPLC equipped with UVD/MS was studied. METHODS AND RESULTS: Oxycarboxin was extracted with acetone from hulled rice, soybean, Kimchi cabbage, green pepper, and apple samples. The extract was diluted with saline water, followed by liquid-liquid extraction with methylene chloride. Florisil column chromatography was employed for the purification of the extracts. Oxycarboxin was determined on a Zorbax SB-AQ $C_{18}$ column by HPLC with UVD. Accuracy of the proposed method was validated by the recovery tests from crop samples fortified with oxycarboxin at 3 levels per crop. CONCLUSION: Mean recoveries ranged from 78.3% to 96.1% in five representative agricultural commodities. The coefficients of variation were less than 10%, and limit of quantitation of oxycarboxin was 0.04 mg/kg. A confirmatory technique using LC/MS with selected-ion monitoring was also provided to clearly identify the suspected residue. The method was reproducible and sensitive to determine the residue of oxycarboxin in agricultural commodities.

Development of Isotope Dilution LC-MS/MS Method for Accurate Determination of Arsenobetaine in Oyster Certified Reference Material

  • Lee, Woo Young;Yim, Yong-Hyeon;Hwang, Euijin;Lim, Youngran;Kim, Tae Kyu;Lee, Kyoung-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.821-827
    • /
    • 2014
  • An isotope dilution liquid chromatography tandem mass spectrometry (ID LC-MS/MS) method has been developed and applied to the determination of arsenobetaine (AsB, ${(CH_3)_3}^+AsCH_2COO^-$) from oyster candidate certified reference material (CRM). The exact matching isotope dilution approach was adopted for accurate determination of AsB using $^{13}C_2$-labeled AsB as an internal standard. Efficiencies of different AsB extraction methods were evaluated using a codfish reference material and a simple sonication method was selected as the method of choice for the certification of the oyster candidate CRM. The hydrophilic interaction liquid chromatography (HILIC) combined with electrospray ionization tandem mass spectrometry (ESI/MS/MS) in selected reaction monitoring (SRM) mode was optimized for adequate chromatographic retention and robust quantification of AsB from codfish and oyster samples. By analyzing 12 subsamples taken from each 12 bottles systematically selected from the whole oyster CRM batch, the certified value of AsB was determined as $6.60mg{\cdot}kg^{-1}{\pm}0.31mg{\cdot}kg^{-1}$ and it showed excellent between-bottle homogeneity of less than 0.42%, which is represented by relative standard deviation of 12 bottles from the CRM batch. The major source of uncertainty was the certified value of the AsB standard solution.

An 8b 220 MS/s 0.25 um CMOS Pipeline ADC with On-Chip RC-Filter Based Voltage References (온-칩 RC 필터 기반의 기준전압을 사용하는 8b 220 MS/s 0.25 um CMOS 파이프라인 A/D 변환기)

  • 이명진;배현희;배우진;조영재;이승훈;김영록
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.69-75
    • /
    • 2004
  • This work proposes an 8b 220 MS/s 230 mW 3-stage pipeline CMOS ADC with on-chip filers for temperature- and power- insensitive voltage references. The proposed RC low-pass filters improve switching noise performance and reduce reference settling time at heavy R & C loads without conventional off-chip large bypass capacitors. The prototype ABC fabricated in a 0.25 um CMOS occupies the active die area of 2.25 $\textrm{mm}^2$ and shows the measured DNL and INL of maximum 0.43 LSB and 0.82 LSB, respectively. The ADC maintains the SNDR of 43 dB and 41 dB up to the 110 MHz input at 200 MS/s and 220 MS/s, respectively, while the SNDR at the 500 MHz input is degraded as much as only 3 dB than the SNDR at the 110 MHz input.