• Title/Summary/Keyword: 3Liter House

Search Result 6, Processing Time 0.02 seconds

The Technology Applied 3 Liter House, Super Energy Saving Building (3L House의 설계, 시공 및 평가)

  • Park, Sun-Hyo;Park, Yong-Seung;Won, Jong-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.814-819
    • /
    • 2006
  • This research is on the design and introducing of integrated thermal performance of super energy saying building, called 3 Liter house which can be sustained with 3 liter oil(kerosene) per $yr.m^2$. 3 liter houses(Passive houses) offer extended living comfort with only 15 to 20% of the space heating demand of conventional new building. To achieve this purpose, the efficiency of building components is improved, such as walls, windows or ventilation system and the construction technology is improved, such as the prevention of thermal bridge and the air tightness. The fuel cell is used as alternative energy. Energy consumption of 3L house is 2.08 [liter/$yr.m^2$] in monitoring result of $2006/2/1{\sim}2/7$ and ACH50 is 0.67 in result of Blow Door Test, therefore 3L House is well- insulated and well- airtighted house.

  • PDF

The Characteristic of the Concentration Transition of Chemical Substances in Energy Saving House and Apartment House (에너지절약 주택과 일반 아파트에서의 실내 화학오염물질 농도 변화 특성)

  • Yoo, Bok-Hee;Park, Sun-Hyo
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the indoor air pollutant. Volatile Organic Compounds $(VOC_s)$ and formaldehyde have been considered as one of the main reason that causes indoor air pollutant. This study is for introducing and designing thermal performance of super energy saving building by conducting $VOC_s$ and formaldehyde concentration in the 3Liter house. The results of the measurement for 10 months showed that $VOC_s$ and formaldehyde decreased until the guideline concentration. It took about 7 months, and it appeared right after new construction. However, their levels were showed higher concentration in comparison with the ordinary residential houses (apartment house). The main difference of between newly built 3Liter house and ordinary apartment is their air changes, which are 0.67/h for 3Liter house and 4.0/h for the apartment.

Rainwater Harvesting System as an Alternative Water Source

  • Kim, Phil-S.;Yoo, Kyung-H.;Kim, Sun-Joo;Lee, Nam-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.524-528
    • /
    • 2009
  • The objectives of this study were to install RCR systems at a typical single family house and a school in Alabama, and evaluate the feasibility and efficiency of using the RCR systems for water harvesting in Alabama. The RCR systemswere equipped with a control system and a CR10X data logger to monitor the system operation and to collect data on precipitation, temperature, overflow, water depth in the storage tank and daily uses of toilet flushing. Daily average water use of the home for toilet flushing was 95 liter and 2100 liter was used at the school during the school days. Rainwater harvesting efficiency was 83.3 and 89 percent and RCR use efficiency was 18 and 98 percent from the home and the school, respectively. A computer program was developed to estimate potential effectiveness of RCR systems. From the analysis result with 10 years rainfall data, a total of 67,000 liters of rainwater could be harvested for domestic uses from a typical single family house which supplies 190 liters per day.

  • PDF

Design and Verification of Ceramic Heating Element-based Tankless Instant Electric Water Heater (세라믹 발열체기반 비저장식 순간 전기 온수기 개발 및 검증)

  • Ahn, Sung-Su;Kim, Woo-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.151-159
    • /
    • 2016
  • This paper proposes a ceramic heating element-based tankless instant electric water heater for hand/face washing that does not require a lot of hot water. The heating module, which heats the input water and outputs hot water, operates the ceramic heating element detecting input water using a flow sensor. Inside of the heating module is designed to form one flow path in order to get almost $15^{\circ}C$ increased heated water compared to the input water temperature within 2 second after 1.5 liter per minute water supply. The design validity is verified using a heat flow analysis of the water flow and temperature variations inside of the heating module also. Based on the design data, the heating module is constructed including a single rod-type ceramic heating element. After that, a prototype system having temperature setting function by three steps were constructed. The prototype system is connected to a 1.5 liter per minute water supply line, and the water output temperature and time measurement experiments confirmed that the proposed system output the heated water increased by $18.3^{\circ}C$ in case of third step setting within 2 second after water supply. And standby power is under 1 W and peak power does not exceed the permissible range for the general house usage. Several performance results verify that the proposed tankless instant electric water heater is applicable for the washstand of the house, highway rest area and factory so on as winter-time hand/face washing.

End-use Analysis of Household Water by Metering (가정용수의 용도별 사용 원단위 분석)

  • Kim, Hwa Soo;Lee, Doo Jin;Kim, Ju Whan;Jung, Kwan Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.595-601
    • /
    • 2008
  • The purpose of this study is to investigate the trends and patterns of various kind of water uses in a household by metering in Korea. Water use components are classified by toilet, washbowl, bathing, laundry, kitchen, miscellaneous. Flow meters are installed in 140 household selected by sampling in all around Korea. The data are gathered by web-based data collection system from the year 2002 to 2006, considering pre-investigated data such as occupation, revenue, family members, housing types, age, floor area, water saving devices, education, miscellaneous. Reliable data are selected by upper fence method for each observed water use component and statistical characteristics are estimated for each residential type to determine liter per capita per day. Estimated domestic per capita day show an indoor water use with the range from 150 lpcd to 169 lpcd for each housing type as the order of high rise apartment, multi-house, and single house. As the order of consuming amount among water use components, it is investigated that toilet (38.5 lpcd) is the first, and the second is laundry water (30.8 lpcd), the third is kitchen (28.4 lpcd), the fourth is bathtub (24.7 lpcd), the next is washbowl (15.4 lpcd). The results are compared with water uses in U.K. and U.S. As life style has been changed into western style, pattern of water use in Korea is tend to be similar with the U.S. water use pattern. Compared with the surveying results by Bradley, on 1985. Thirty liter of total use increased with the advancement of economic level, and a little change of water use pattern can be found. Especially, toilet water take almost half part of total water use and laundry water shows lowest as 11% in surveying at the year of 1985. But, this study shows that 39 liter, 28% of toilet water, has been decreased by the spread of saving devices and campaign. It is supposed that the spread large sized laundry machine make by-hand laundry has been decreased and water use increased. Unit water amount of each end-use in household can be applied to design factor for water and wastewater facilities, and it play a role as information in establishing water demand forecasting and conservation policy.

Biological Control of Strawberry Gray Mold Caused by Botrytis cinerea Using Bacillus licheniformis N1 Formulation

  • Kim, Hyun-Ju;Lee, Soo-Hee;Kim, Choul-Sung;Lim, Eun-Kyung;Choi, Ki-Hyuck;Kong, Hyun-Gi;Kim, Dae-Wook;Lee, Seon-Woo;Moon, Byung-Ju
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.438-444
    • /
    • 2007
  • Bacillus licheniformis N1 is a biological control agent to control gray mold diseases caused by Botrytis cinerea. Various formulations of B. licheniformis N1 were generated and evaluated for the activity to control strawberry gray mold. The wettable powder type formulation N1E was selected in pot experiments with remarkable disease control activity on both strawberry leaves and flowers. The N1E formulation contained 400 g of com starch, 50 ml of olive oil, and 50 g of sucrose per a liter of bacterial fermentation culture. Optimum dilution of N1E to appropriately control the strawberry gray mold appeared to be 100-fold dilution in plastic house artificial infection experiments. The significant reduction of symptom development in the senescent leaves was apparent by the treatment of N1E at 100-fold dilution when N1E was applied before Bo. cinerea inoculation, but not after the inoculation. Both artificial infection experiments in a plastic house and natural infection experiments in the farm plastic house under production conditions revealed that the disease severity of gray mold on strawberry leaves and flowers was significantly reduced by N1E treatment. The disease control value of N1E on strawberry leaves was 81% under production conditions, as compared with the 61.5% conferred by a chemical fungicide, iprodione. This study suggests that our previously generated formulation of B. licheniformis N1 will be effective to control strawberry gray mold by its preventive activity.