• Title/Summary/Keyword: 3DT

Search Result 553, Processing Time 0.027 seconds

Sedative and Analgesic Effects of Intravenous Detomidine and Tramadol on Horses (말에서 detomidine과 tramadol의 정맥 투여에 의한 진정 및 진통효과)

  • Kim, Tae-Hoon;Jang, Min;Lee, Hang;Lee, In-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.29 no.3
    • /
    • pp.226-232
    • /
    • 2012
  • This study was performed to evaluate the sedative and analgesic effects of intravenous (IV) administration of detomidine (D) and tramadol (T) to horses. Six warmblood horses each received D (10 ${\mu}g/kg$), T (2 mg/kg), and a combination of DT (10 ${\mu}g/kg$ and 2 mg/kg). No significant differences in the heart rate, respiratory rate, rectal temperature, indirect arterial pressure, and gastrointestinal motility between D and DT were observed. The sedative effect was evident within 5 min after D and DT administration, but no significant difference between D and DT was observed. D and DT induced a similar analgesic effect up to 50 min after injection and DT maintained a longer analgesic effect than D. A significant increase in blood glucose was shown for D after the injection, but not for DT. A horse with T and DT showed an excited behavior within 5 min of the injection. This study suggests that the DT combination could be used for diagnostic procedures and simple surgeries in standing horses, with caution for excitement in the early phase after the administration.

Analysis of Image Quality According to Imaging Parameters in Digital Tomosynthesis (디지털 단층영상합성장치의 영상획득 조건에 따른 화질 분석)

  • Lee, Dahye;Lee, Seungwan;Kim, Burnyoung;Yim, Dobin;Nam, Kibok;Cho, Jeonghyo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.477-486
    • /
    • 2020
  • The purpose of this study was to evaluate the effects of reconstruction filters, X-ray source trajectories and intervals in the quality of digital tomosynthesis (DT) images, and the results was clinically validated. The filtered back-projection was implemented by using Ramp, Shepp-Logan, Cosine, Hamming, Hann and Blackman filters, and the X-ray source trajectories were simulated with 1 × 36, 2 × 18, 3 × 12, 4 × 9 and 6 × 6 arrays. The X-ray source intervals were 5, 10, 20, 30 and 40 mm. The depth resolution, spatial resolution and noise of DT image were evaluated by measuring artifact spread function (ASF), full width at half maximum (FWHM) and signal-to-noise ratio (SNR), respectively. The results showed that the spatial resolution and noise properties of DT images were maximized by the Ramp and Blackman filters, respectively, and the depth resolution and noise properties of the DT images obtained with a 1 × 36 X-ray source trajectory were superior to the other trajectories. The depth resolution and noise properties of DT images improved with an increase of X-ray source intervals, and the high X-ray source intervals degraded the spatial resolution of DT images. Therefore, the characteristics of DT images are highly dependent on reconstruction filters, X-ray source trajectories and intervals, and it is necessary to use optimal imaging parameters in accordance with diagnostic purpose.

Trends in the Growth of Literature on Hepatitis(1984-2003): Quantitative Analysis (간염에 관한 문헌의 증가추세(1984-2003): 계량적 분석)

  • Babu, B. Ramesh;Ramakrishnan, J.
    • Journal of Korean Library and Information Science Society
    • /
    • v.38 no.2
    • /
    • pp.31-50
    • /
    • 2007
  • This paper presents a scientometric analysis of the growth of literature output in the field of Hepatitis covered in three bibliographic databases namely MEDLINE, CINAHL and IPA. The literature covered in three databases for the period 1984-2003 was considered. MEDLINE covered the maximum of 75750 records during the study period 1984 to 2003. This is followed by CINAHL and IPA databases. It is found that the annual growth rate of literature in a particular field of knowledge will not be uniform and in order to measure the rate of growth from year after year, the application of RGR is quite appropriate. The RGR has shown a decreasing trend, with a slight fluctuation of growth rate for the years 1985 and 1997. The output by colleges, universities, corporate sector and research institutions with reference to RGR and Dt has shown mixed results such as increasing trend, decreasing trend and fluctuation trend. Hepatitis research indicates a different picture when the RGR and Dt were calculated by year-wise both in terms of number of papers and number of pages.

  • PDF

Application of Decision Tree to Classify Fall Risk Using Inertial Measurement Unit Sensor Data and Clinical Measurements

  • Junwoo Park;Jongwon Choi;Seyoung Lee;Kitaek Lim;Woochol Joseph Choi
    • Physical Therapy Korea
    • /
    • v.30 no.2
    • /
    • pp.102-109
    • /
    • 2023
  • Background: While efforts have been made to differentiate fall risk in older adults using wearable devices and clinical methodologies, technologies are still infancy. We applied a decision tree (DT) algorithm using inertial measurement unit (IMU) sensor data and clinical measurements to generate high performance classification models of fall risk of older adults. Objects: This study aims to develop a classification model of fall risk using IMU data and clinical measurements in older adults. Methods: Twenty-six older adults were assessed and categorized into high and low fall risk groups. IMU sensor data were obtained while walking from each group, and features were extracted to be used for a DT algorithm with the Gini index (DT1) and the Entropy index (DT2), which generated classification models to differentiate high and low fall risk groups. Model's performance was compared and presented with accuracy, sensitivity, and specificity. Results: Accuracy, sensitivity and specificity were 77.8%, 80.0%, and 66.7%, respectively, for DT1; and 72.2%, 91.7%, and 33.3%, respectively, for DT2. Conclusion: Our results suggest that the fall risk classification using IMU sensor data obtained during gait has potentials to be developed for practical use. Different machine learning techniques involving larger data set should be warranted for future research and development.

Comparison of Initial Adsorption Rate of Brown and Milled Rices During Storage at $25^{\circ}C$ (현미와 백미의 저장 중 초기흡습 속도의 비교)

  • Song, Bo-Hyeon;Kim, Dong-Youn;Kim, Sung-Kon;Kang, Seong-Koo
    • Applied Biological Chemistry
    • /
    • v.32 no.2
    • /
    • pp.79-84
    • /
    • 1989
  • Initial adsorption rates of brown and milled rices at relative humidity of $57{\sim}86%$ were examined at $25^{\circ}C$. The adsorption equations at RH 75% for brown and milled rices were expressed as: log($d{\omega}/dt{\times}10^{3}$)=-0.8108 log t+3.0347 and log($d{\omega}/dt{\times}10^{3}$)=0.8451 log t+3.0087, respectively, where ${\omega}$ is the moisture content(%, db) and t is storage time (hr). The moisture content at RH $57{\sim}86%$ could be calculated from above equations using a conversion factor for each RH.

  • PDF

A Study on the Ametropia in Asian Population (아시아 동양인들의 비정시에 관한 연구)

  • Lee, Young-Il;Hong, Jin Seok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2008
  • Purpose: This study was to investigate the refractive state of an asian population (male: 39, female: 53) from 21 to 30 years old who visited the A optical shop at jongnogu in seoul. Methods: The visual acuity test was performed by the object and subject method. Results: Among the 184 eyes, myopia is 83.16% and emmetropia is 16.84%, respectively. As for the equivalent spheric power of myopic abnormal refractive eyes, the -m0.5Dt < spheric equivalent ${\leq}$ -2.00Dt was 40.53%, the -2.00Dt < spheric equivalent ${\leq}$ -6.00Dt was 51.63% and anything over the -6.00Dt was 7.85%. The percentages of with-the-rule, against-the-rule and oblique astigmatism among people with astigmatism were 46.67%, 35.56% and 7.77%, respectively. The average of pupillary distance in male (64.5${\pm}$2.9 mm) was greater than that in female (61.9${\pm}$2.3 mm). Conclusions: Korean opticians were provided some useful information about making up a prescription by this research.

  • PDF

Influence of the Geometry of Guide Groove on Stress Corrosion Index of Rock in Double Torsion Test (이중 비틀림 시험에서 유도 홈의 형상이 암석의 응력부식지수에 미치는 영향)

  • 정해식;미원우삼;전석원
    • Tunnel and Underground Space
    • /
    • v.14 no.5
    • /
    • pp.363-372
    • /
    • 2004
  • Double torsion (DT) tests were carried out to investigate the influence of the geometry of guide groove on stress corrosion index of Kumamoto andesite. The fracture toughness was measured in the constant displacement rate, which was set to 2.07 MN/m$^{3}$2/ in average regardless of crack velocity. Stress corrosion indices, n were evaluated using specimens with rectangular, circular and triangular grooves and were 37, 36 and 38 in average, respectively. The n values were constant regardless of the groove geometry, however the DT specimen with triangular groove geometry showed the largest standard deviation in the relationship between crack velocity and stress intensity factor. The DT test was found to be effective in using a rectangular-grooved specimen and the width of the groove must be greater than the average grain size of minerals.

A Study on Reperfusion Arrhythmia III. Relationship to Hemodynamics Changes and Occurrence of Reperfusion Arrhythmia after Occlusion of Coronary Artery in Dogs (Reperfusion Arrhythmia에 관한 연구 III. 관상동맥 폐색시의 혈액동력학적인 변화와 RA발생과의 관계)

  • 최인혁;정인성;최은경;김희은
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.402-410
    • /
    • 2001
  • This study was performed to investigate the hemodynamic changes which occur after occlusion of coronary artery and relation to reperfusion arrhythmias(RA) which occur when occlusion materials were removed form coronary artery in dogs. The occlusion of coronary artery was designed by temporary ligation of left circumflex branch of coronary artery during 30 minutes in 16 dogs. During occlusion of coronary artery, cardiac output(CO), mean aortic pressure (mAP), aortic systolic pressure(ASP), aortic diastolic pressure(ADP). left ventricular systolic pressure(LVSP), left ventricular maximum dp/dt (LV max. dp/dt) and left ventricular end-diastolic pressure (LVEDP) were measured. The occurrence of RA were observed for 5 minute after reperfusion by explained of ligation. As a results, cardiac arrest occurred in 4 dogs during occlusion of coronary artery, and RA was not observed in 5 dogs while it was seen in 5 dogs when explained ligation(reperfusion) after 30 minutes, the rest 2 dogs occurred temporary tachycardia. In hemodynamics changes, LVSP decreased by 10.9% and LV max. dp/dt by 5.4 % in comparison to control value which not ligated coronary artery, and LVEDP increased by 73.3%. The CO/min and mAP also decreased by 10.7% and by 11.3% expectedly. In the relationship to occurrence RA and hemodynamics changes, the LVSP and LV max. dp/dt at the time of occlusion in the RA group decreased by 11.9% and 0.8% in comarison to the control value while the decrease was 7.7% and 10% in the non-RA group. But the LVEDP in creased by 109.1% in the RA group while the decreased was 44.6% in the non-RA group. Referring CO/min, the drop was 8.8% in the RA occurrence group and 12.9% in the non-occurence group. These parameters of LVEDP, LV max. dp/dt, and CO were significant difference(p<0.05). The mAP also decreased by 11.9 in the RA group and by 9.8% in the non-RA group, but these defference were not the significant difference.

  • PDF

Application and Performance Analysis of Machine Learning for GPS Jamming Detection (GPS 재밍탐지를 위한 기계학습 적용 및 성능 분석)

  • Jeong, Inhwan
    • The Journal of Korean Institute of Information Technology
    • /
    • v.17 no.5
    • /
    • pp.47-55
    • /
    • 2019
  • As the damage caused by GPS jamming has been increased, researches for detecting and preventing GPS jamming is being actively studied. This paper deals with a GPS jamming detection method using multiple GPS receiving channels and three-types machine learning techniques. Proposed multiple GPS channels consist of commercial GPS receiver with no anti-jamming function, receiver with just anti-noise jamming function and receiver with anti-noise and anti-spoofing jamming function. This system enables user to identify the characteristics of the jamming signals by comparing the coordinates received at each receiver. In this paper, The five types of jamming signals with different signal characteristics were entered to the system and three kinds of machine learning methods(AB: Adaptive Boosting, SVM: Support Vector Machine, DT: Decision Tree) were applied to perform jamming detection test. The results showed that the DT technique has the best performance with a detection rate of 96.9% when the single machine learning technique was applied. And it is confirmed that DT technique is more effective for GPS jamming detection than the binary classifier techniques because it has low ambiguity and simple hardware. It was also confirmed that SVM could be used only if additional solutions to ambiguity problem are applied.

The Effects of Elastic Ankle Taping on Static and Dynamic Postural Control in Individuals With Chronic Ankle Instability

  • Lim, Jin-seok;Kim, Seo-hyun;Moon, Il-young;Yi, Chung-hwi
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.200-207
    • /
    • 2021
  • Background: Postural control deficit is a major characteristic in patients with chronic ankle instability (CAI). Elastic ankle tapings are commonly used to facilitate postural control in patients with CAI as well as prevent relapse of a lateral ankle sprain. However, equivocal evidence exists concerning the effect of elastic ankle taping on postural control. Objects: This study aimed to evaluate the effects of elastic ankle tapings using kinesio taping (KT) and dynamic taping (DT) on static and dynamic postural control in patients with CAI. Methods: Fifteen subjects with CAI were participated in this study. The participants performed tests under three conditions (barefoot, KT, and DT). Static postural control was evaluated using the one-leg standing test (OLST) and dynamic postural control using the modified Star Excursion Balance Test (mSEBT). One-way repeated-measures analysis of variance was used to compare center of pressure (CoP) data and normalized mSEBT reach distances among the three conditions (with α = 0.05). Results: The CoP parameters (path length, ellipse area, and mean velocity) of the OLST significantly decreased on applying KT and DT compared with those when barefoot. The normalized reach distances in the anteromedial (AM), medial (M), and posteromedial (PM) directions of the mSEBT significantly increased with DT compared to that in the control condition. Further, the higher reach distances with KT compared with those in the control condition were obtained in the M and PM directions of the mSEBT. No significant differences were identified in any of the OLST and SEBT parameters between the two different taping applications. Conclusion: KT and DT improved static postural control during the OLST compared with the control condition. Moreover, these tapes improved dynamic postural control during the mSEBT compared to the control. Therefore, elastic ankle tapings are useful prophylactic devices for the prevention and treatment of ankle sprain in people with CAI.