• Title/Summary/Keyword: 3D-printed

Search Result 665, Processing Time 0.026 seconds

Design of DVB-T/H SiP using IC-embedded PCB Process (IC-임베디드 PCB 공정을 사용한 DVB-T/H SiP 설계)

  • Lee, Tae-Heon;Lee, Jang-Hoon;Yoon, Young-Min;Choi, Seog-Moon;Kim, Chang-Gyun;Song, In-Chae;Kim, Boo-Gyoun;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.9
    • /
    • pp.14-23
    • /
    • 2010
  • This paper reports the fabrication of a DVB-T/H System in Package (SiP) that is able to receive and process the DVB-T/H signal. The DVB-T/H is the European telecommunication standard for Digital Video Broadcasting (DVB). An IC-embedded Printed Circuit Board (PCB) process, interpose a chip between PCB layers, has applied to the DVB-T/H SiP. The chip inserted in DVB-T/H SiP is the System on Chip (SoC) for mobile TV. It is comprised of a RF block for DVB-T/H RF signal and a digital block to convert received signal to digital signal for an application processor. To operate the DVB-T/H IC, a 3MHz DC-DC converter and LDO are on the DVB-T/H SiP. And a 38.4MHz crystal is used as a clock source. The fabricated DVB-T/H SiP form 4 layers which size is $8mm{\times}8mm$. The DVB-T/H IC is located between 2nd and 3rd layer. According to the result of simulation, the RF signal sensitivity is improved since the layout modification of the ground plane and via. And we confirmed the adjustment of LC value on power transmission is necessary to turn down the noise level in a SiP. Although the size of a DVB-T/H SiP is decreased over 70% than reference module, the power consumption and efficiency is on a par with reference module. The average power consumption is 297mW and the efficiency is 87%. But, the RF signal sensitivity is declined by average 3.8dB. This is caused by the decrease of the RF signal sensitivity which is 2.8dB, because of the noise from the DC-DC converter.

A Study on the Printability according to Ink-Jet Paper of Digital Web-Printing (디지털 윤전 인쇄에서 잉크젯 전용지에 따른 인쇄 적성에 관한 연구)

  • Oh, Se-Jin;Kim, Sung-Su;Koo, Chul-Whoi
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.31 no.1
    • /
    • pp.39-49
    • /
    • 2013
  • Nowadays the printing market has shift from 2D(two dimension) industry to 3D(three dimension) industry, along with IT. With rapidly changing market, it's true that the effort to develop the printing materials and upgrade the printing qualities is produced actively in the country. Particularly, the differences in printing materials can often determine the quality of printings in the printability. In the case of the printability of offset, 9 items(paper, ink, order of printing, ink supply, blowing-up halftone, grey balance, key color(base color), overlap efficiency, quality at the halftone dot reproduction etc.) are usually considered as the important factors and used to estimate the printability at abroad. However, in domestic, ink-jet paper is not used for the printing/publishing by ink-jet printing for digital, but done mainly for offset printing. Because the paper of gloss coated type, which is the ink-jet paper, has high price, it's too hard to manufacture massively printing/publishing. Also, in the case of the paper of uncoated type, in spite of its reasonable price rather than the former, the type of uncoated one also has demerit that the ink-jet paper has a clear difference between the front and the back. Therefore, it's tough reality that Ink Jet paper is hardly taken advantage of as the printing/publishing. Thus, what is done in the first to print and/or publish on ink-jet paper is that the front and the back must be printed evenly, and appropriate to the printability of ink-jet. Although there're some kinds of ink-jet paper in the country, it has not been produced in true domestic production yet. In addition, thanks to the brightness of fluorescence brightening agent, the foreign product can offer the good-qualified one-time printing. But when it comes to the printing/publishing, there're difficulties that it may cause the Ocular Fatigue because of long-term exposure of the eyes to text. This research tries to find out the optimum ink-jet paper in domestic for the printing/publishing by studying on the printability of ink-jet on digital web-printing. And it also tries to look for the paper's brightness which can be reduce the possibility to cause the consumers' Ocular Fatigue.

A Study on the Small Loop Antenna with a Parasitic Loop Structure for Multiband Mobile Phone Application (기생 루프 구조를 이용한 휴대 단말기용 다중 대역 초소형 루프 안테나에 관한 연구)

  • Lee, Sang-Heun;Kim, Ki-Joon;Jung, Jong-Ho;Yoon, Young-Joong;Kim, Byoung-Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.706-713
    • /
    • 2010
  • In this paper, the small loop antenna with a parasitic loop structure for penta-band mobile phone application is proposed. This antenna is composed of a feed monopole, a radiating loop antenna with a parasitic loop structure and an additional radiating element. The antenna is printed on the very thin flexible substrate to mount on the dielectric carrier with a volume of 40 mm$\times$11 mm$\times$3 mm. The bandwidth of the proposed antenna is 402 MHz(773~1,175 MHz) for low band and 583 MHz(1,622~2,205 MHz) for high band. As a result, the proposed antenna covers the five bands of GSM850, GSM900, DCS1800, PCS1,900 and WCDMA for a 3:1 VSWR. Moreover, the radiation pattern, gain and efficiency are appropriate for mobile handset. Therefore, this antenna is suitable for small sized multi-band mobile handset applications.

Setup Verification in Stereotactic Radiotherapy Using Digitally Reconstructed Radiograph (DRR) (디지털화재구성사진(Digitally Reconstructed Radiograph)을 이용한 정위방사선수술 및 치료의 치료위치 확인)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.84-88
    • /
    • 1999
  • Purpose :To develop a method for verifying a treatment setup in stereotactic radiotherapy by ma- tching portal images to DRRs. Materials and Methods : Four pairs of orthogonal portal images of one patient immobilized by a thermoplastic mask frame for fractionated stereotactic radiotherapy were compared with DRRs. Portal images are obtained in AP (anteriorfposterior) and lateral directions with a target localizer box containing fiducial markers attached to a stereotactic frame. DRRs superimposed over a planned iso-center and fiducial markers are printed out on transparent films. And then, they were overlaid over onhogonal penal images by matching anatomical structures. From three different kind of objects (isgcenter, fiducial markers, anatomical structure) on DRRs and portal images, the displacement error between anatomical structure and isocenters (overall setup error), the displacement error between anatomical structure and fiducial markers (irnrnobiliBation error), and the displacement error between fiducial markers and isocenters (localization error) were measured. Results : Localization error were 1.5$\pm$0.3 mm (AP), 0.9$\pm$0.3 mm (lateral), and immobilization errors were 1.9$\pm$0.5 mm (AP), 1.9$\pm$0.4 mm (lateral). In addition, overall setup errors were 1.0$\pm$0.9 mm (AP), 1.3$\pm$0.4 mm (lateral). From these orthogonal displacement errors, maximum 3D displacement errors($\sqrt{(\DeltaAP)^{2}+(\DeltaLat)^{2}$)) were found to be 1.7$\pm$0.4 mm for localization, 2.0$\pm$0.6 mm for immobilization, and 2.3$\pm$0.7 mm for overall treatment setup. Conclusion : By comparing orthogonal portal images with DRRs, we find out that it is possible to verify treatment setup directly in stereotactic radiotherapy.

  • PDF

Development of a prototype simulator for dental education (치의학 교육을 위한 프로토타입 시뮬레이터의 개발)

  • Mi-El Kim;Jaehoon Sim;Aein Mon;Myung-Joo Kim;Young-Seok Park;Ho-Beom Kwon;Jaeheung Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.257-267
    • /
    • 2023
  • Purpose. The purpose of the study was to fabricate a prototype robotic simulator for dental education, to test whether it could simulate mandibular movements, and to assess the possibility of the stimulator responding to stimuli during dental practice. Materials and methods. A virtual simulator model was developed based on segmentation of the hard tissues using cone-beam computed tomography (CBCT) data. The simulator frame was 3D printed using polylactic acid (PLA) material, and dentiforms and silicone face skin were also inserted. Servo actuators were used to control the movements of the simulator, and the simulator's response to dental stimuli was created by pressure and water level sensors. A water level test was performed to determine the specific threshold of the water level sensor. The mandibular movements and mandibular range of motion of the simulator were tested through computer simulation and the actual model. Results. The prototype robotic simulator consisted of an operational unit, an upper body with an electric device, a head with a temporomandibular joint (TMJ) and dentiforms. The TMJ of the simulator was capable of driving two degrees of freedom, implementing rotational and translational movements. In the water level test, the specific threshold of the water level sensor was 10.35 ml. The mandibular range of motion of the simulator was 50 mm in both computer simulation and the actual model. Conclusion. Although further advancements are still required to improve its efficiency and stability, the upper-body prototype simulator has the potential to be useful in dental practice education.