• 제목/요약/키워드: 3D-CFD

검색결과 673건 처리시간 0.024초

상용 CFD코드를 이용한 공조기 입구 형상 설계 (Inlet Shape Design of Air Handling Unit Using Commercial CFD Code)

  • 최영석;주종일;이용갑;주원구
    • 한국유체기계학회 논문집
    • /
    • 제5권3호
    • /
    • pp.54-59
    • /
    • 2002
  • A commercial CFD code is used to compute the 3-D viscous flow field within the inlet flow concentrator of the newly developed AHU (Air Handling Unit). To improve the performance of the AHU, the inlet air needs to be gradually accelerated to the fan's annular velocity without causing turbulence or flow separation. Three major geometric parameters were selected to specify the inlet shape of the AHU. The performance of the AHU could be measured by the inlet and outlet flow uniformity and the total pressure loss through the inlet flow concentrator. Several numerical calculations were carried out to determine the influence of the geometric parameters on the performance of the AHU. The best geometric values were decided to have efficient inlet shape with analyzing CFD calculation results.

CFD를 활용한 브러쉬 요소의 누설유량 예측 해석 (CFD Analysis of Leakage Prediction for Brush Element)

  • 김결;하태웅
    • 한국유체기계학회 논문집
    • /
    • 제20권2호
    • /
    • pp.11-16
    • /
    • 2017
  • The accurate prediction of leakage flow through the brush element of brush seal at the steam turbine is important to find optimum design parameters for increasing an efficiency. In this study, CFD analysis method using commercial software FLUENT is proposed to predict leakage through the brush element. Since the brush element has a complex three-dimensional shape with many bristle assemblies, it is difficult to analyze the flow field. Therefore, if the brush element is assumed to be porous medium region, the analysis time can be shortened. Two determination methods of resistance coefficients of the Darcian porous medium equation are suggested. By comparing the 2D and 3D CFD analysis results for the leakage of the brush element using the two resistance coefficient determination methods, the effectiveness of the analysis for the porous medium assumption is proved.

Study on Wave Energy Generation of Multi-Floating Bodies for Energy Absorption by CFD

  • Li, Kui-Ming;Choi, Yoon-Hwan;Lee, Yeon-Won
    • 동력기계공학회지
    • /
    • 제17권5호
    • /
    • pp.38-43
    • /
    • 2013
  • In order to design a wave energy generating system, a 6-DOF analysis technique is applied to CFD analysis on of a floating body and the behavior is interpreted according to the nature of the incoming waves. A spring constant is adopted to control the motion of multi floating bodies and to calculate the total average power absorption. Three cases of different wavelengths namely 20D, 30D and 40D have been modeled to analyze the total average power absorption. The average power absorption not only varies with the position of the floating body but also varies with wavelength. From the results obtained, it is concluded that the maximum total average power absorption is 9W approximately in wavelength 30D and the minimum total average power absorption is 4.3W approximately in wavelength 40D.

전산유체역학을 이용한 PEMFC의 성능에 대한 3차원 유로 구조의 영향 (Effects of 3D Flow-Channel Configurations on the Performance of PEMFC using Computational Fluid Dynamics)

  • 한경호;윤도영
    • Korean Chemical Engineering Research
    • /
    • 제54권6호
    • /
    • pp.847-853
    • /
    • 2016
  • 본 연구에서는 3차원 전산유체역학 모델을 적용하여 서펜타인 유로를 갖는 고분자 전해질 분리막(PEM) 연료전지의 성능평가를 수행하였다. PEM 연료전지의 전산 모델은 등온조건하에서의 이동현상을 고려하여, 물질 및 운동량 전달, 전극에서의 반응속도론 그리고 전기적 흐름을 모두 포함하였다. 한편, 병류로 흐르도록 형성된 구조의 유로 형태는 본 연료전지모델에서 유로의 폭과 높이의 비인 종횡비와 유로와 립 폭의 비인 반응면적비를 변화시키며 다양한 형상으로 고려되었다. 유로의 형상이 변화될 경우 연료전지 내부의 수소와 산소의 질량분율 분포가 계산되었으며, 이에 따라, 활성화과전압의 계산 값이 변하게 되며 전류밀도 분포가 최종적으로 결정되었다. CFD 결과는 종횡비가 클수록 성능이 증가하고 반응면적비가 클수록 성능이 감소하는 것을 보였다. 본 연구의 모델에 의하면 서펜타인 유로의 형상에 의해, 성능특성이 경향성을 보이는 결과를 보여주었으며, 이와같은 결과는 다른 문헌에 보고 된 CFD 결과들과 전반적으로 잘 부합하는 것으로 나타났다.

터보 팬의 유동해석 및 허니콤 구조가 적용된 터보 팬의 PBF 3D 프린팅 제작에 관한 연구 (A Study on CFD of Turbo fan and Fabrication of Turbo Fan with Honeycombs by PBF)

  • 진철규;이해수;이운길;우재혁
    • 한국산업융합학회 논문집
    • /
    • 제25권5호
    • /
    • pp.899-908
    • /
    • 2022
  • In this study, a study was conducted to localize a large aluminum turbo fan used for tank powerpack. The turbo fan was scanned with a 3D scanner and then 3D modeling was performed. Computational fluid dynamics (CFD) were performed from the performance conditions of the fan, and structural analysis was performed using the pressure data obtained from CFD. The fan was reduced to 1/5 size by applying the geometric similarity. A 1/5 size fan has a honeycomb structure inserted into the front shroud and back shroud to reduce the weight by 5.3%. A 1/5 size fan was printed using a PBF 3D printer, and a 1/5 size fan with honeycombs was also printed. The pressure drop of 8.67 kPa and the required power of 138.19 kW, which satisfies the performance conditions of the fan, were confirmed from the results of CFD. The values of the maximum deformation amount of 0.000788 mm and the maximum effective stress of 0.241 MPa were confirmed from the structural analysis results. The fan printed by the PBF 3D printer had the same shape as the modeling, and the shape was perfect. There are no defects anywhere in appearance. However, the condition of the outer surface of the fan's back shroud is rough compared to other locations. The fan in which the honeycomb was inserted was also perfectly output, and the shape of the honeycomb was the same as the modeling.

CFD-CSD 연계 기법을 이용한 로터 블레이드 공력 및 소음 해석 (AERODYNAMIC AND NOISE CALCULATIONS OF HELICOPTER ROTOR BLADES USING LOOSE CFD-CSD COUPLING METHODOLOGY)

  • 강희정;김도형;위성용
    • 한국전산유체공학회지
    • /
    • 제19권3호
    • /
    • pp.62-68
    • /
    • 2014
  • The aerodynamic and noise calculations were performed through the CFD-CSD loose coupling methodology. In the loose coupling process, the trimmed rotor airloads were predicted by the in-house CFD code based on unstructured overset meshes, and the trim of the rotorcraft and the aeroelastic deformation of rotor blades were accounted with the CAMRAD II rotorcraft comprehensive code. The set of codes was used to analyze the HART-II baseline test condition. The effect of grid resolution and time step was examined and the loose coupling approach was found to be stable and convergent for the case. Comparison of the resulting sectional airloads, structural deformations, the noise carpets and the wake geometry with experimentally measured data was presented and showed the good agreement.

Performance Evaluation of Two-Equation Turbulence Models for 3D Wing-Body Configuration

  • Kwak, Ein-Keun;Lee, Nam-Hun;Lee, Seung-Soo;Park, Sang-Il
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제13권3호
    • /
    • pp.307-316
    • /
    • 2012
  • Numerical simulations of 3D aircraft configurations are performed in order to understand the effects of turbulence models on the prediction of aircraft's aerodynamic characteristics. An in-house CFD code that solves 3D RANS equations and two-equation turbulence model equations are used. The code applies Roe's approximated Riemann solver and an AF-ADI scheme. Van Leer's MUSCL extrapolation with van Albada's limiter is also adopted. Various versions of Menter's $k-{\omega}$ SST turbulence models as well as Coakley's $q-{\omega}$ model are incorporated into the CFD code. Menter's $k-{\omega}$ SST models include the standard model, the 2003 model, the model incorporating the vorticity source term, and the model containing controlled decay. Turbulent flows over a wing are simulated in order to validate the turbulence models contained in the CFD code. The results from these simulations are then compared with computational results from the $3^{rd}$ AIAA CFD Drag Prediction Workshop. Numerical simulations of the DLR-F6 wing-body and wing-body-nacelle-pylon configurations are conducted and compared with computational results of the $2^{nd}$ AIAA CFD Drag Prediction Workshop. Aerodynamic characteristics as well as flow features are scrutinized with respect to the turbulence models. The results obtained from each simulation incorporating Menter's $k-{\omega}$ SST turbulence model variations are compared with one another.

마이크로 모세관 유동 해석을 위한 CFD-VOF 모텔 응용 (Application of CFD-VOF Model to Autonomous Microfluidic Capillary System)

  • 정자훈;임예훈;한상필;석지원;김영득
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.224-229
    • /
    • 2004
  • The objective of this work is not only to perform feasibility studies on the CFD (computational fluid dynamics) analysis for the capillary system design but also to provide an enhanced understanding of the autonomous capillary flow. The capillary flow is evaluated by means of the commercial CFD software of FLUENT, which includes the VOF (volume-of-fluid) model for multiphase flow analysis. The effect of wall adhesion at fluid interfaces in contact with rigid boundaries is considered in terms of static contact angle. Feasibility studies are first performed, including mesh-resolution influence on pressure profile, which has a sudden increase at the liquid/gas interface. Then we perform both 2D and 3D simulations and examine the transient nature of the capillary flow. Analytical solutions are also derived for simple cases and compared with numerical results. Through this work, essential information on the capillary system design is brought out. Our efforts and initial success in numerical description of the microfluidic capillary flows enhance the fundamental understanding of the autonomous capillary flow and will eventually pave the road for full-scale, computer-aided design of microfluidic networks.

  • PDF

수치모형을 이용한 과부하 사각형 맨홀에서의 손실계수 산정 (Estimation of Head Loss Coefficients at Surcharged Square Manhole Using Numerical Model)

  • 김정수;임가희;임창수;윤세의
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.143-150
    • /
    • 2011
  • 도시 우수 배수 시스템에서 우수 관거는 개수로 흐름 상태로 가정하여 설계되었기 때문에 맨홀에서의 에너지 손실은 일반적으로 중요하게 고려되지 않았다. 그러나 과부하흐름에서 에너지 손실은 관거의 배수능력을 저하시켜 도심지역의 침수피해를 가중시키는 요인이 된다. 그러므로 과부하 사각형 맨홀 내에서의 수두 손실을 분석할 필요가 있다. 본 연구에서는 FLUENT 6.3 모형을 이용하여 과부하 사각형 합류맨홀에서의 흐름특성을 모의하고 맨홀 내 손실수두의 변화를 계산하여 손실계수를 산정하였다. 또한 실험결과와 수치모의 결과를 비교 및 분석하여 사각형 맨홀에서의 손실계수 산정에 FLUENT 6.3모형의 적용성을 확인하였다. 맨홀 폭(B)과 연결관경(d)의 비(B/d)에 따른 손실계수를 산정하였다. B/d가 증가할수록 사각형 합류 맨홀에서의 손실계수는 증가하였다. 중간 단차 맨홀에서 단차 변화에 따른 손실계수의 변화를 산정하였다. 단차가 5 cm이상 증가하면 맨홀 내 수심과 손실계수가 점진적으로 증가하였으므로 중간 맨홀에서의 적정 단차는 5 cm로 판단된다. 따라서 우수 관거 시스템의 여러 형태의 사각형 맨홀에서의 흐름의 변화 및 손실계수를 예측할 때, Fluent 6.3 모형은 사용 가능하리라 판단된다.

터보펌프용 연료펌프의 설계와 CFD를 이용한 성능 평가 (Hydraulic design of fuel pump in turbo-pump system and performance evaluation using CFD)

  • 이경훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.408-416
    • /
    • 2002
  • Hydraulic performance of the pump with an inducer was predicted by 3-D Navier-stokes calculation. The evaluated pump was the single-stage centrifugal pump with a separated inducer to pressurize fuel (LCH4) in Turbo-pump system with a specific speed (Ns) of approximately 0.3[rad/s, m3/s, J/kg] and a suction specific speed(s) of 15[rad/s, m3/s, J/kg]. That conventional pump was designed with the combination of 1-D theory and empirical correlation. In this study, preliminary design to select key parameters such as inlet flow coefficient was reviewed by investigating sets of the known design methods to achieve appropriate suction performance, and the performance of newly designed inducer and impeller was compared with the old one, using CFD method. The numerical results showed that the hydraulic efficiency of the new pump was predicted $5.5\%$ higher than that of the conventional one, through design parameter re-selection, configuration improvement and blade loading control

  • PDF