• Title/Summary/Keyword: 3D-CFD

Search Result 678, Processing Time 0.034 seconds

A DESIGN OPTIMIZATION STUDY OF BLUNT NOSE HYPERSONIC FLIGHT VEHICLE MINIMIZING SURFACE HEAT-TRANSFER RATE AND DRAG (표면 열전달율과 항력을 최소화한 극초음속 비행체 선두부 형상 최적설계)

  • Lim S.;Seo J. I.;Kim S. D.;Song D. J.
    • Journal of computational fluids engineering
    • /
    • v.10 no.3 s.30
    • /
    • pp.27-35
    • /
    • 2005
  • A design optimization of hypersonic flight vehicle has been studied by using upwind Navier-Stokes method and numerical optimization method. CFD method is linked to numerical optimization method by using a Bezier curve and a design optimization of blunt nose hypersonic flight vehicle has been studied. Heat transfer coefficient and drag coefficient are selected as objective functions or design constraints. The Bezier curve-based shape function was applied to blunt body shape.

Development and Analysis on Noise Characteristics of Low Noise Cooling Fan for an Alternator by Using Numerical Method (수치적 방법을 이용한 저소음 얼터네이터 냉각팬의 개발 및 소음 특성 분석)

  • Kim, Wook;Jeon, Wan-Ho;Hyun, Jae-Jin;Lim, Chul-Koo;Lee, Sung-Ha
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.608-609
    • /
    • 2008
  • An alternator which converts mechanical rotating energy into electric energy is an important component of a vehicle. It operates in broad range from 3000 RPM to 18000 RPM. So, sufficient flow rate and low noise are needed in such broad operating range for a cooling fan of this alternator. In current study, the cooling fan of an alternator is developed through DFSS process and numerical analysis. In order to calculate flow rate and noise level, SC/Tetra and FlowNoise S/W are used respectively, for a new developed fan, compared with original model, numerical result shows 3 dBA reduction and measured value shows 4 dBA reduction.

  • PDF

Study on the Characteristics of Heat Transfer with Array of Multiple Impinging Jet Nozzle (충돌제트 노즐의 다중 배열 형상에 따른 열전달 특성)

  • Kim, D.K.;Son, J.D.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.32-37
    • /
    • 2006
  • In this paper, we present the flow and heat transfer characteristics with the array of impinging jet nozzles by using the numerical computation and experiment. Numerical solutions were obtained for dimensionless gap H=6, dimensionless outlet length L=10 and Reynolds number Re=1500 by using the commercial CFD code, CFX-5. Experimental and numerical results were agreed well with each other. It was found that the impinging jet with circular array nozzles generated the uniform heat transfer area and the maximum heat transfer is higher than rectangular array nozzles for certain parameter sets. It is one of the most important utilities providing steam to turbine in order to supply mechanical energy in thermal power plant. It is composed of thousands of tubes for high efficient heat transfer.

  • PDF

DFSS OPTIMUM DESIGN OF LOW NOISE COOLING FAN FOR AN ALTERNATOR BY NUMERICAL METHOD (수치기법을 이용한 저소음 얼터네이터 냉각팬의 DFSS 최적 설계)

  • Kim, W.;Jeon, W.H.;Hyun, J.J.;Lim, C.K.;Lee, S.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.233-238
    • /
    • 2008
  • An alternator which converts mechanical rotating energy into electric energy is an important component of a vehicle. It operates in broad range from 3000 RPM to 18000 RPM. So, sufficient flow rate and low noise are needed in such broad operating range for a cooling fan of this alternator. In current study, the cooling fan of an alternator is developed through DFSS process and numerical analysis. In order to calculate flow rate and noise level, SC/Tetra and Flow Noise are used respectively, for a new developed fan, compared with original model, numerical result shows 3 dBA reduction and measured value shows 4 dBA reduction.

  • PDF

A Development of General Purpose Program NUFLEX for the Analysis of Heat/Fluid Flow (범용 열/유체 유동해석 프로그램 NUFLEX의 개발)

  • Hur N.;Won C.-S.;Son G.;Ryou H.-S.;Shin D.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.53-59
    • /
    • 2004
  • A general purpose program NUFLEX for the analysis of 3-D heat/fluid flow in complex geometry with pre/post processor have been developed, which consists of a flow solver based on FVM and a dedicated pre/post processor. The program employs a general non-orthogonal grid system and solve laminar and turbulent (lows with standard and RNG $\kappa-\epsilon$ turbulence models. NUFLEX is capable of analysing two-phase flow with topologically complex interface, turbulent diffusion combustion, solidification problems and magnetic flow. For the purpose of verification of the program and testing the applicability, several practical problems are solved and compared with the available data. Comparison of the NUFLEX results with that by the STAR-CD program has been also made for the same flow configuration and grid structure.

  • PDF

DFSS OPTIMUM DESIGN OF LOW NOISE COOLING FAN FOR AN ALTERNATOR BY NUMERICAL METHOD (수치기법을 이용한 저소음 얼터네이터 냉각팬의 DFSS 최적 설계)

  • Kim, W.;Jeon, W.H.;Hyun, J.J.;Lim, C.K.;Lee, S.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.233-238
    • /
    • 2008
  • An alternator which converts mechanical rotating energy into electric energy is an important component of a vehicle. It operates in broad range from 3000 RPM to 18000 RPM. So, sufficient flow rate and low noise are needed in such broad operating range for a cooling fan of this alternator. In current study, the cooling fan of an alternator is developed through DFSS process and numerical analysis. In order to calculate flow rate and noise level, SC/Tetra and Flow Noise are used respectively, for a new developed fan, compared with original model, numerical result shows 3 dBA reduction and measured value shows 4 dBA reduction.

  • PDF

A Study on the Development of a 4,000CMM Grade Blower for a Ventilation System (환기시스템용 4000CMM급 송풍기 개발에 관한 연구)

  • Lee, Cheon-Suk;Lee, Won-Uk;Jang, Sung-Cheol;Yi, Chung-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • This study is about the development and revision of a blower design for a ventilation system. In this study, to describe the flow in the 4000CMM grade blower, 3-dimensional steady-state turbulence was assumed to govern the flow equation. The flow field with velocity distribution according to the elbow duct of the ventilation system is also compared. Finally, vibration was observed in the blower at the installation to ventilation system. The cause was due to a problem in the manufacturing process of the airfoil type impeller.

Numerical Study on Polishing Behavior during Oxide CMP (Oxide CMP 과정에 대한 수치 유동 해석)

  • Kwon, Dal-Jung;Lee, Do-Hyung;Hong, Yi-Koan;Park, Jin-Goo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.922-927
    • /
    • 2003
  • In this paper, slurry fluid motion, abrasive particle motion, and roles of groove patterns on the pads are numerically investigated in the 2D and 3D geometries. The simulation results are analyzed in terms of experimental removal rate and WIWNU (within wafer non-uniformity) for ILD (inter level dielectric) CMP process. Numerical investigations reveal that the grooves in the pad behave as uniform distributor of abrasive particles and enhance the removal rate by increasing shear stress. Higher removal rate and desirable uniformity are numerically and experimentally observed at the pad with grooves. Numerical analysis is very well matched with experimental results and helpful for understanding polishing mechanism and local physics.

  • PDF

Aerodynamic Design of Slim and High-efficient Turbo-Fan (박판형 고효율 터보홴의 공력학적 설계)

  • Lee, Myeong-Jae;Kim, Nam-Uk;Park, Duck-Jun;Cho, In-Soo;Lee, Seung-Bae
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2600-2605
    • /
    • 2008
  • Turbo-fans for a FFU unit should be aerodynamically designed to provide the FFU system with the given flow-rate at the lowest rotational-speed by considering the interaction effect with the FFU casing. In this study, slim and highly efficient turbo-fans are designed to satisfy the given performance at the specific speed by using the hybrid-stacking method of an inducer and a 2D-bladed turbo fan. The mean-line analysis, cascade theory, and CFD technique are all together applied to control the passage areas on the meridional plane from the inlet to the exit of the blade. Furthermore, the torque control algorithm is adopted to improve the performances within the constraints by the motor rpm-torque characteristics, and the resulting measured performances of mock-up fans are discussed.

  • PDF

2D 플라잉 디스크의 피칭 운동에 따른 비정상 유동 해석

  • Park, Da-Un;Kim, Tae-Uk
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.566-570
    • /
    • 2016
  • 본 연구에서는 플라잉 디스크를 이용하여 Pitching 운동 조건에서의 공력특성을 해석하였다. 본 해석에서 사용한 플라잉 디스크 모델은 프리원 151_140이며, 해석자로는 KFLOW_EDISON_2D_3DOF를 사용하였다. Pitching 운동이 있는 경우 받음각의 변화에 따른 공력특성을 비교 분석하였다. 기준 받음각의 변화에 따라 형상 아랫면과 뒷전 부근에 실속 와류가 다른 형태로 생겨 플라잉 디스크의 공력 특성에 영향을 준다는 것을 확인하였다. 또한, 기준 받음각이 증가 할수록 강한 실속 와류가 발생함을 알 수 있다.

  • PDF