• Title/Summary/Keyword: 3D-CFD

Search Result 673, Processing Time 0.03 seconds

3D GEOMETRY EFFECTS ANALYSIS ON PROPAGATION OF PRESSURE WAVE GENERATED BY HIGH-SPEED TRAIN TRAVELING IN A TUNNEL USING CFD (3차원 형상을 고려한 고속철도에 의한 터널내 압력파 전파의 CFD 해석)

  • Shin, D.Y.;Lee, S.G.;Oh, H.J.;Kim, H.G.;Yoon, S.H.;Kim, C.J.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.49-55
    • /
    • 2012
  • Research has importance in proposing the design of a tunnel with a vertical vent to secure passengers in a comfortable environment and safe against pressure. Using several analysis methods, the magnitude of the pressure induced by the vertical vent in the tunnel can be analyzed. In addition to the 3-dimensional method, the 2-dimensional method and the 2-dimensional axis-symmetric method are also used to analyze the strong and weak points of each so that the optimum analysis method can be obtained. As a result, it appears that the 2-dimensional axis-symmetric method is the most suitable in analyzing tunnel pressure consider to accuracy and time effective aspect. Also, the 3-dimensional method is disadvantageous in that it takes longer in calculating results, but is more effective in predicting phenomena around the vertical vent in the tunnel.

A Numerical Simulation of Flows in an Engine Cooling Passage (엔진 냉각유로 내의 유동에 관한 수치해석)

  • 허남건;윤성영;조원국;김광호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.1
    • /
    • pp.32-40
    • /
    • 1993
  • Flow fields in model engine cooling passages are studied numerically by using TURBO-3D program, a finite volume based 3-D turbulent flow program adopting a general body fitted coordinate system. The effects of exit position on mass flow rate at each gasket hole are examined for a model cooling passage in order to understand the flow distribution inside the water jacket. The results of the present study can be applied to the design of high performance, high reliability engine.

  • PDF

Performance Analysis of PEMFC Using Computational Flow Dynamics (CFD) (전산유체역학 (CFD)을 이용한 PEMFC의 성능분석)

  • Kim, Sunhoe
    • Journal of Digital Convergence
    • /
    • v.11 no.8
    • /
    • pp.199-204
    • /
    • 2013
  • Computational fluid dynamics (CFD) is used to reduce number of experiments. The CFD tools are widely used for engine design and flow pattern analysis to reduce experiments. In this study the performance of a PEMFC single cell was analyzed by using STAR-CD, product of CD-ADAPCO. The effect of cell design and flow pattern on the performance of a PEMFC was analyzed with the 3-D simulation. As a result the performance of rectangular cell was the higher than that of square cell, while the flow direction scarcely affected on the performance of a PEMFC. Also the current density according to different excess ratio of air flow rate was compared and analyzed. The difference between maximum and minimum current density of flip-flow was lower than that of co-flow.

A Comparison between Various CFD Solvers for Analysis on Thermal Load in Smart Farm(Fluent, Open-FOAM, Blender) (스마트팜 열부하 분석을 위한 CFD 해석 도구 비교)

  • Lee, Jun-Yeob;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.170-170
    • /
    • 2017
  • 기후변화 따른 스마트팜 돈사 외부 환경의 변화에 대응하고, 사육 환경을 능동적으로 개선하기 위한 연구가 수행 중이다. 돈사 내 열전달 요소 간 상호 역학성 분석을 위해서 고려해야할 사항은 입기구, 보온 등, 열풍기, 단열제, 위치, 방향, 돈사의 연평균 온도, 습도, 연중 일사량, 가축의 열복사 등 상호 복잡하게 연관되어 있는 물리량이다. 돈사 전체 열손실, 자연발생 에너지량, 강제발생 에너지량, 난방용량 등을 고려한 순간 열부하 산정을 위한 여러 방법 중 우선적으로 CFD(Computational Fluid Dynamics)를 이용하였다. 순간 열부하 산정을 위한 해석 도구 선정에 있어서 다양한 유체 및 기체 전산 유체역학 Solver(Fluent, Open-FOAM, Blender)를 고려하였다. 공간 Mech를 수행하기 위한 도구로는 공개 소프트웨어 인 FreeFem++ 3.51-4 (http://www.freefem.org)를 이용하였다. 이 과정에서 일부 기체 (암모니아)의 농도를 난수로 변화시키는 기법을 적용하여 가상적으로 돈사의 환경을 Pseudo 시뮬레이션 하였다. 결과적으로 Fluent에 비하여 OpenFOAM을 이용하여 얻은 열유동의 방향(속도)과 크기 백터가 상대적으로 크게 나타났다. Fluent가 시계열 상에서 혼합 기체 물리량 변화를 무시할 수 있는 안정되고 균일한 환경에 적합하기 때문인 것으로 판단되었다. Blender의 경우 Lattice Boltzmann methods 과 Smoothed-particle hydrodynamics 방법을 이용한 유체/입자 동력학 모델링을 제공함에 있어 시각적 효과를 강조하는 기능에 중점을 두었다. Fluent와 Blender에서 제공하는 해석 연산 모듈의 정확성 검증을 위해선 공간 분해능을 높인 정밀 계측 시스템을 이용하여 검증할 필요가 있다. Open-FOAM를 이용한 열부하 분석 수행이 상대적으로 높은 절대값을 보이는 특성은 열부하 제어 시스템의 Overshoot를 유발할 가능성이 있으므로 이에 대한 해석 모델의 보정이 추가적으로 필요할 것이다. CFD의 한계인 시간 복잡도를 낮추고 상대적으로 높은 시계열 분해능을 확보할 경우 돈사 내 환기시스템에 맞는 소요 환기량 실시간 산정이 가능해지고 외부기상 및 돈사내부 복사열을 활용함과 동시에 돈군 순환에 상응하는 실시간 열부하 관리 시스템 도출이 가능할 것이다.

  • PDF

Design of 3D printed chip for thrombus measurement and feasibility study for smoking effect (혈전 측정용 3D printed chip 설계 및 흡연의 영향 사전 연구)

  • Haebeen Kim;Eunseop Yeom
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.74-79
    • /
    • 2023
  • Thrombogenesis, which is the process of blood clot formation, can be initiated by platelet activation. Excessive formation of blood clot in the bloodstream can lead to thrombosis. Therefore, when dealing with patients with disseminated intravascular coagulation (DIC) or children, it is necessary to use small amounts of blood. Hence, it is important to develop methods for the rapid and accurate measurement of the platelet function using a small amount of blood. In this study, 3D printing technology was utilized to facilitate the production of micro channels. The amount of platelet adhesion in smokers and non-smokers was compared by repeatedly exposing the structure of the channel to adjust the number of blood injections and facilitate thrombosis attachment to simple stenosis structures.

Method to Derive the Optimal Vent Position when Flammable Liquid Leaks Based on CFD (CFD 기반 인화성 액체 누출 시 최적의 환기구 배치 도출 방안)

  • Eun-Hee Kim;Seung-Hyo An;Jun-Seo Lee;Byung-Chol Ma
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.11-18
    • /
    • 2024
  • If flammable liquid leaks, vapor evaporated from the pool can cause poisoning or suffocation to workers, leading to secondary accidents such as fires and explosions. To prevent such damage, ventilation facilities shall be installed when designing indoor workplaces. At this time, the behavior varies depending on the characteristics of the leaked chemical, so it is necessary to select a suitable vent location according to the material. Therefore, 3D CFD simulations were introduced to derive optimal vent position and ventilation efficiency was quantitatively evaluated by vent position. At this time, assuming a situation in which flammable liquids leak at indoor workplaces to form pools, the concentration of vapor evaporated from pools was compared to derive the optimal vent position. As a result of research on toluene with high vapor density, ventilation efficiency was confirmed to be the highest at the upper supply-lower exhaust, and it is judged that introducing it can achieve about 3.7 times ventilation effect at the same maintenance cost. Through this study, it is expected that the workplace will be able to secure workers' safety by applying simulation results and installing ventilation ports.

Using Data Gloves for control of the 3-Dimensional postprocessing software (Data Glove를 이용한 3차원 데이터 후처리 소프트웨어의 제어)

  • Kim K. Y.;Kim B. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.56-61
    • /
    • 2004
  • As the size and dimension of target problems in the field of computational engineering including CFD gets bigger and higher, it is needed to have more efficient and flexible data visualization environment in terms of software and hardware. Even though it is still manageable to use a mouse in controlling 3-dimensional data visualization, it would be beneficial to use 3-D input device for 3-D visualization. 'Data Glove' is one of the best 3-D input devices, because human hands are best tools understanding 3-D space. Signals coming from 'Data Glove' are analog and very sensitive to finger motions, so we decided to use a digital filter. This paper describes our experience and benefits of using data glove in controlling 3-Dimensional Postprocess Software.

  • PDF

Numerical Analysis of the 3-D Flow Field in a Globe Valve Trim under High Pressure Drop (고차압 제어용 글로브 밸브 트림 내부의 3차원 유동장 해석)

  • Yoon, Joon-Yong;Byun, Sung-Joon;Yang, Jae-Mo;Lee, Do-Hyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.3 s.12
    • /
    • pp.14-20
    • /
    • 2001
  • Numerical analysis of the three dimensional turbulent flow field in a complex valve trim is carried out to confirm the possibility whether this simulation tool can be used as a design tool or not. The simulation of the incompressible flow in a glove valve is performed by using the commercial code. CFD-ACEA utilizes the finite volume approach as a discretization scheme, and the pressure-velocity coupling is made from SIMPLEC algorithm in it. Four flow cases of the control valve are investigated, and the valve flow coefficient for each case is compared with the experimental data. Simulation results show a good agreement with the experiments, and it is observed that the cavitation model improves the simulation results.

  • PDF

A Numerical Study for Reducing Cavitation in a Butterfly Valve with a Perforated Plate (다공판이 설치된 버터플라이밸브의 캐비테이션 발생 저감에 관한 수치적 연구)

  • Jo, Seong Hwi;Kim, Hong Jip;Song, Keun Won
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.65-70
    • /
    • 2014
  • The effectiveness of a perforated plate installed additionally at butterfly valve to reduce cavitation which can cause vibration, noise, erosion, and flow path blockage has been investigated using CFD. Rayleigh-Plesset equation was applied to simulate cavitation phenomena. 3D flow simulations have been performed for 6 cases to consider the occurrence of cavitation at the downstream of the valve. From the present results, the perforated plate was thought to be very effective to suppress the cavitation inside of the pipe.

Study on the Thermal Behavior of Immersion Cooled LED Lighting Engines (담금 냉각되는 LED 조명엔진의 열특성에 대한 연구)

  • Kim, Kyoung Joon
    • Journal of Power System Engineering
    • /
    • v.18 no.3
    • /
    • pp.87-92
    • /
    • 2014
  • This study is aimed at investigating the thermal behavior of immersion-cooled high power LED lighting engines. 3D CFD models have been generated for the numerical analysis. Five cases in terms of the configuration of LED chips have been explored for various passive cooling conditions of the lighting engine, i.e., the natural air convection with a lens, the natural air convection without a lens, the deionized water-immersion cooling condition with a lens. The numerical study reveals that the deionized water-immersion cooled lighting engine has nearly twice better thermal performance than the natural air convection cooled lighting engine containing a lens. The investigation has also demonstrated that the four chips configuration has the better thermal performance than the single chip configuration.