• Title/Summary/Keyword: 3D-CFD

Search Result 673, Processing Time 0.026 seconds

Analysis of Impulse Turbine for Wave Energy Conversion Using CFD Method (수치해석을 이용한 파력발전용 임펄스 터어빈의 성능해석)

  • Hyun, Beom-Soo;Moon, Jae-Seung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.81-86
    • /
    • 2003
  • This paper deals with the performance analysis and design of impulse turbine for OWC type wave energy plant. Numerical analysis was performed using a commercially-available software FLUENT. This parametric study includes the variation of several important parameters such as the number and shape of blades, hub ratio and tip clearance. Since parametric study at various flow coefficients requires considerable amount of computing tim, two-dimensional analysis was employed to find out optimum principal particulars in rather simple manner. Full three-dimensional calculation was also performed for several test cases to confirm the validity of two-dimensional approach. Up to the present stage, tentative result is well demonstrating the usefulness of 2-D analysis.

  • PDF

Analysis of Impulse Turbine for Wave Energy Conversion Using CFD Method (수치해석을 이용한 파력발전용 임펄스 터어빈의 성능해석)

  • HYUN BEOM-SOO;MOON JAE SEUNG
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.5
    • /
    • pp.1-6
    • /
    • 2004
  • This paper deals with the performance analysis and design of impulse turbine for owe type wave energy plant. Numerical analysis is performed using a commercial software FLUENT. This parametric study includes the variation of several important parameters, such as the number and shape of blades, hub ratio, and tip clearance. Since parametric study at various flow coefficients requires a considerable amount of computing time, two-dimensional analysis is employed to find out optimum principal particulars. Full three-dimensional calculations are also performed for several test cases, in order to confirm the validity of the two-dimensional approach. Up to the present stage, tentative results are demonstrated the usefulness of 2-D analysis.

EXAMPLES OF REDUCED ORDER MODELLING FOR A 3D BACKWARD FACING STEP FLOW USING POD TECHNIQUE (POD를 사용한 3차원 후향계단 유동장 분석 예제)

  • Lee, K.S.;Lee, E.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.40-42
    • /
    • 2010
  • Unsteady CFD results of the backward facing step (BFS) flow field is reconstructed by the low-dimenstional modes using the POD (Proper Orthogonal Decomposition) technique. Flow responses to the blowing or suction with various frequencies and amplitudes applied at the edge of the BFS can also be analysed using the same technique. The present technique can be effectively applied to the feedback flow control device.

  • PDF

A Study on Calculation of Leakage for LPG Explosion Accident using 3D Scan and CFD (3D 스캔과 CFD를 활용한 LPG 폭발사고의 누출량 산정에 관한 연구)

  • Cho, Wan Su;Kim, Eui Soo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.1-7
    • /
    • 2018
  • Recently, various engineering approaches have been widely used in the accident investigation field to identify the cause of the accident and to predict damage by accident. Computational analysis is the most commonly used method of accident investigation technique. This technique is mainly used to identify the mechanism of the accident generation and to determine the cause when it is difficult to reproduce the situation at the time of the accident or when it is impossible to perform a reproduction experiment. In this study, The gas explosion analysis for LPG explosion accident generated by defect of the blocking action was performed to determine the accident object, gas leakage amount and predicted the damage caused by the accident using 3D laser scanner and FLACS program. We can quantify the explosive power by LPG gas accident and predict the gas leakage amount, damage by accident and evaluate the stability of the structure through this study. In the future, This method can be widely used in the field of gas safety by improving the reliability and validity of the analysis.

Development of the 3-D Bulk Motion Index for In-Cylinder Flow Induced by Induction System (I) - Based on the 3-D CFD Simulation Results - (흡기시스템을 통해 실린더로 유도되는 공기의 3차원 Bulk Motion Index 개발 (I) - 3차원 유동해석결과를 중심으로 -)

  • Yun, Jeong-Eui;Nam, Hyeon-Sik;Kim, Myung-Hwan;Min, Sun-Ki;Park, Pyeong-Wan;Kim, Ki-Seong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.11 s.254
    • /
    • pp.1057-1065
    • /
    • 2006
  • In order to figure out the physical meaning of 3-D angular flow index for in-cylinder bulk motion, CFD analysis for the swirl and tumble steady flow test rig were made using commercial package STAR-CD. Computer simulations and rig tests on some kinds of induced flow conditions were carried out. Finally, based on the comparison between the simulated results and measured results, the physical meaning of 3-D angular flow index $|\longrightarrow_{N_B}|$, $\beta$ composed of swirl and tumble coefficients measured by steady flow test rig was described.

Performance Optimization of High Specific Speed Pump-Turbines by Means of Numerical Flow Simulation (CFD) and Model Testing

  • Kerschberger, Peter;Gehrer, Arno
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.352-359
    • /
    • 2010
  • In recent years, the market has shown increasing interest in pump-turbines. The prompt availability of pumped storage plants and the benefits to the power system achieved by peak lopping, providing reserve capacity, and rapid response in frequency control are providing a growing advantage. In this context, there is a need to develop pumpturbines that can reliably withstand dynamic operation modes, fast changes of discharge rate by adjusting the variable diffuser vanes, as well as fast changes from pumping to turbine operation. In the first part of the present study, various flow patterns linked to operation of a pump-turbine system are discussed. In this context, pump and turbine modes are presented separately and different load cases are shown in each operating mode. In order to create modern, competitive pump-turbine designs, this study further explains what design challenges should be considered in defining the geometry of a pump-turbine impeller. The second part of the paper describes an innovative, staggered approach to impeller development, applied to a low head pump-turbine project. The first level of the process consists of optimization strategies based on evolutionary algorithms together with 3D in-viscid flow analysis. In the next stage, the hydraulic behavior of both pump mode and turbine mode is evaluated by solving the full 3D Navier-Stokes equations in combination with a robust turbulence model. Finally, the progress in hydraulic design is demonstrated by model test results that show a significant improvement in hydraulic performance compared to an existing reference design.

Application of CFD Program for Analyzing the Hydrodynamic Characteristics of Baffled PAC Contactor (격벽식 분말활성탄 접촉조의 흐름해석을 위한 전산유체역학 프로그램의 적용)

  • Ahn, Chang-Jin;Ahn, Sang-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.221-229
    • /
    • 2002
  • For the efficient design of baffled Powdered activated carbon(PAC) contractor, which has been widely used in water treatment plant(WTP) against the algae-related odor problems, a CFD(computational fluid dynamics) program was applied. In order to verify the performance of FLOW-3D program, the previously reported results of tracer tests from a pilot-scale PAC contractor(working volume of 288 liters) were compared to those from FLOW 3D. The results of FLOW-3D simulation were very similar to those from tracer tests conducted with the Pilot-scale PAC contactor. On the other hand, the hydrodynamic characteristics of baffled contractor in the P-WTP were simulated by using FLOW-3D. Simulation results on the distribution of PAC particles showed that there are some stagnant parts in the back side of baffles in which PAC Particles are not present. These stagnant parts might decrease the adsorption capacity of PAC particles. When the baffles were changed to maze-type intra-basin baffling, PAC particles were evenly distributed and the amount of stagnant parts reduced. In conclusion, it is anticipated that FLOW-3D simulation could be a viab1e tool for analyzing the hydrodynamic characteristics of structures used in drinking water treatment plant.

Prediction of Air Movement and Temperature Distribution at Different Store Methods Using 3-D CFD Simulation in Forced-Air Cooling Facility

  • Yang, G.M.;Koh, H.K.
    • Agricultural and Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.65-72
    • /
    • 2002
  • Temperature is the most influential environment parameter which affects the quality change of agricultural products in cold storage. Therefore, it is essential to keep the uniform temperature distribution in the storage room. This study was performed to analyze the air movement and temperature distribution in the forced recirculating cold storage facility and to simulate optimum storage method of green groceries using 3-D CFD(three dimensional computational fluid dynamics) computer simulation which applied the standard $textsc{k}$-$\varepsilon$ turbulence model and FVM(finite volume method). The simulation was validated by the experimental results for onion storage and the simulation model was used to simulate the temperature and velocity distribution in the storage room with reference to the change of storage method such as location of storage, no stores, bulk storage, and pallet storage. In case of no stores, internal airflow was circulated without stagnation and consequently air movement and temperature distribution were uniform. In case of bulk storage, air movement was stagnated so much and temperature distribution of onion was not uniform. Furthermore, the inner temperature of onion roses more than the initial temperature of storage. In case of pallet storage, air movement and temperature distribution of onion were so uniform that the danger of quality change was decreased.

  • PDF

Performance Analysis of the Vertical Multi-stage Centrifugal Pump using Commercial CFD Code (상용 CFD코드를 이용한 입형 다단 원심펌프 성능해석)

  • MO Jang-Oh;KANG Shin-Jeong;SONG Geun-Taek,;NAM Cheong-Do;LEE Young-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.150-155
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pump including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is not only to confirm how much the effect of three kinds of blade inlet breadth (11mm, 11.5mm, 12mm) of impeller has influence on the performance of vertical multi-stage pump but also to make clear the cause about performance difference at the exit side of impeller and guide vane. The vertical multi-stage pump consisit of the impeller, guide, vane and cylinder. The grid of numerical analysis used to the vertical multi-stage pump is 18,000, 45,000, and 100000 cells in case of the impeller, guide vane, cylinder and total grid is 730,000 cells. The characteristics such as total pressure coefficient, total head, shaft horse power, power efficiency at the exit side of impeller and guide vane, discharge coefficient are represented according to flow rage changing.

  • PDF