• Title/Summary/Keyword: 3D ultrasonography

Search Result 69, Processing Time 0.026 seconds

Correlations between the Clinical and Ultrasonographic Parameters of Congenital Muscular Torticollis without a Sternocleidomastoid Mass

  • Jisun Hwang;Eun Kyung Khil;Soo Jin Jung;Jung-Ah Choi
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1374-1382
    • /
    • 2020
  • Objective: To determine whether ultrasonography at initial presentation can help assess the clinical severity of congenital muscular torticollis (CMT) in infants without a sternocleidomastoid muscle (SCM) mass. Materials and Methods: This retrospective study included 71 infants aged less than 12 months (4.1 ± 2.3 months) with non-mass CMT. The clinical severity was divided into three grades (groups 1-3) based on the degree of lateral head bending or cervical rotation. The difference (SCM-D) and ratio (SCM-R) between the maximal thickness of the affected and non-affected SCMs were obtained using transverse and longitudinal ultrasonography. The sonographic echotexture and echogenicity of the involved SCM were reviewed. Results: A significant difference was observed in the SCM-D (0.42 ± 0.30 mm in group 1; 0.74 ± 0.50 mm in group 2; 1.14 ± 0.85 mm in group 3; p = 0.002) and SCM-R (1.069 ± 0.067 in group 1; 1.129 ± 0.087 in group 2; 1.204 ± 0.150 in group 3; p = 0.001) among the groups when measured along the longitudinal but not along the transverse ultrasonography plane. The areas under the curves of the SCM-R and SCM-D measured by longitudinal ultrasonography were 0.731 (p < 0.001) and 0.731 (p < 0.001) for group 1 versus groups 2-3. The proportions of heterogeneous echotexture or hyperechogenicity in the involved SCM did not differ significantly among the three clinical groups (all p > 0.05). Conclusion: Ultrasonography can aid in assessing the clinical severity of CMT in infants without an SCM mass at the time of initial diagnosis. The SCM-R and SCM-D helped grade the clinical severity when obtained by longitudinal scan.

Construction of Static 3D Ultrasonography Image by Radiation Beam Tracking Method from 1D Array Probe (1차원 배열 탐촉자의 방사빔추적기법을 이용한 정적 3차원 초음파진단영상 구성)

  • Kim, Yong Tae;Doh, Il;Ahn, Bongyoung;Kim, Kwang-Youn
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.128-133
    • /
    • 2015
  • This paper describes the construction of a static 3D ultrasonography image by tracking the radiation beam position during the handy operation of a 1D array probe to enable point-of-care use. The theoretical model of the transformation from the translational and rotational information of the sensor mounted on the probe to the reference Cartesian coordinate system was given. The signal amplification and serial communication interface module was made using a commercially available sensor. A test phantom was also made using silicone putty in a donut shape. During the movement of the hand-held probe, B-mode movie and sensor signals were recorded. B-mode images were periodically selected from the movie, and the gray levels of the pixels for each image were converted to the gray levels of 3D voxels. 3D and 2D images of arbitrary cross-section of the B-mode type were also constructed from the voxel data, and agreed well with the shape of the test phantom.

Correlation between Transient Elastography (Fibroscan®) and Ultrasonographic and Computed Tomographic Grading in Pediatric Nonalcoholic Steatohepatitis

  • Lee, Ji Eun;Ko, Kyung Ok;Lim, Jae Woo;Cheon, Eun Jung;Song, Young Hwa;Yoon, Jung Min
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.3
    • /
    • pp.240-250
    • /
    • 2022
  • Purpose: This study aimed to examine the advantages and usefulness of transient elastography (Fibroscan®) in diagnosing non-alcoholic steatohepatitis in children and adolescents compared to those of abdominal computed tomography and liver ultrasonography. Methods: Forty-six children and adolescent participants aged between 6 and 16 years who underwent transient elastography (Fibroscan®) as well as liver ultrasonography or abdominal computed tomography were included. Thirty-nine participants underwent liver ultrasonography and 11 underwent computed tomography. The physical measurements, blood test results, presence of metabolic syndrome, and the degree of liver steatosis and liver fibrosis were analyzed, and their correlations with transient elastography (Fibroscan®), abdominal computed tomography, and liver ultrasonography, as well as the correlations between examinations, were analyzed. Results: Thirty-six participants (78.3%) were boys, and the mean age was 12.29±2.57 years, with a mean body mass index of 27.88±4.28. In the 46 participants, the mean values for aspartate aminotransferase, alanine aminotransferase, and total bilirubin were 89.87±118.69 IU/L, 138.54±141.79 IU/L, and 0.77±0.61 mg/dL, respectively. Although transient elastography (Fibroscan®) and abdominal computed tomography grading had a statistically significant positive correlation with aspartate aminotransferase and alanine aminotransferase values, the correlations between the results of grading performed by transient elastography (Fibroscan®), abdominal computed tomography, and liver ultrasonography were not statistically. Conclusion: We confirmed that each examination was correlated with the results of some blood tests, suggesting the usefulness and possibility of diagnosis and treatment of steatohepatitis mediated by transient elastography (Fibroscan®) in the department of pediatrics.

Ultrasonographic Findings in a Case of Primary Hepatoma (원발성간암(原發性肝癌) 1례(例)의 초음파진단(超音液診斷))

  • Moon, Soo-Hyung;Kim, Kang-Sueck
    • The Journal of the Korean life insurance medical association
    • /
    • v.3 no.1
    • /
    • pp.233-244
    • /
    • 1986
  • We'd experienced a case of primary hepatoma at medical department, Dae han Kyoyuk Ins. Company January 1985. As it was found very early stage, we made out the case long term-survival possibility unexpectedly. The conclusions we gained, making comparative-analysis of ultrasonic view and operation's view are as follows; 1. By ultrasonography, echogenicity of tumor was increased type as compared with liver parenchyme. 2. The margin of the primary hepatoma by ultrasonography encapsulated well and the extraction after operation was same. 3. The boundary of tumor was clear. 4. The space-occupying lesion in liver was solitary. 5. The affected site was left lobe of the liver. 6. We couldn't discover a little fluid echo in upper abdomen on the ultrasonography, but could see in the cul-de-sac area and it accorded with the gross finding during laparotomy. 7. The case was cholangiocarcinoma in view of pathologic histology. 8. After the operation of lobectomy. the prognosis which was passed a months was very satisfactory and she exists until present.

  • PDF

Implementation of the Linear Regression Equation for Gestational Age Prediction in the 3D Ultrasonography (3차원초음파에서 임신주수 예측을 위한 선형회귀방정식의 구현)

  • Yang, SungHee;Lee, Jin-Soo;Kim, Jung-Hoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.276-282
    • /
    • 2015
  • Fetal cerebellum is grow depending on the gestational age, measurement of transverse cerebellar diameter(TCD) is being used import indicator of fetal growth prediction in clinical. In this study, the subjects were normal pregnant women 20~37 week of gestation, and the volume scan was conducted on the 340 subjects. The research reports was indicated by regression curve the growth of fetal TCD in accordance with the gestational age. It got to the value of the results from a linear regression equation. Measurement fetal TCD using 3D US was statistically significant(p<0.001) and useful in the prediction of gestational age. TCD increases with gestational age can also distinguish between the normal fetal and prediction of accurate gestational age of fetal growth retardation. If the basic data of the present study, ongoing research is performed, the TCD using by 3D US are expected to be usefully applied in the correct prediction gestational age.

An Experimental Comparative Study of Radiography, Ultrasonography and CT Imaging in the IV Catheter Fragment (정맥내 카테터 조각의 엑스선, 초음파 및 CT 영상의 실험적 비교 연구)

  • Kweon, Dae Cheol
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.185-191
    • /
    • 2016
  • The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon$^{(R)}$ IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose ($0.2139mSv{\cdot}Gy^{-1}{\cdot}cm^{-2}$) form DAP DAP ($0.93{\mu}Gy{\cdot}m^2 $), and dose length product (DLP) ($201mGy{\cdot}cm$) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.

Preoperative Three Dimensional Ultrasonographic Evaluation of the Rotator Cuff Tear (회전근 개 파열에 대한 수술 전 3차원 초음파 검사의 유용성)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Han, Jung-Il
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.24-28
    • /
    • 2008
  • Purpose: We wanted to determine if preoperative three dimensional (3D) ultrasonographic evaluation for rotator cuff tear is useful to measure the real size of a torn rotator cuff for performing an operation Materials and Methods: This study included 15 cases (7 males and 8 female), and these patients were confirmed to have a full thickness tear of the rotator cuff by 3D ultrasonography and the operative findings, as well as on the magnetic resonance imaging (MRI). The average age of the patients was 55.4yrs. Results: The average difference between the 3D ultrasonographic and operative measurements of the full thickness tear of the rotator cuff was 0.7 mm in the transverse length and 2.0 mm in the longitudinal length. Conclusion: The low error between the 3D ultrasonographic and intraoperative measurements of rotator cuff tear shows the usefulness of preoperative 3D ultrasonographic evaluation for rotator cuff tear.

Comparison of Clinical Characteristics According to the Existence of Secondary Appendicitis in Pediatric Acute Enterocolitis: A Single Center Study

  • Choi, So Yoon
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.24 no.2
    • /
    • pp.127-134
    • /
    • 2021
  • Purpose: In patients with acute enterocolitis, radiologic findings are sometimes accompanied by secondary inflammation of the appendix. The purpose of this study was to evaluate the clinical features of acute enterocolitis with secondary inflammation of the appendix. Methods: Medical records from patients who underwent abdominal ultrasonography or computed tomography (CT) among those admitted for acute enterocolitis were retrospectively reviewed. Clinical features were compared by distinguishing patients with inflammation of the appendix from those without, based on their symptoms and laboratory findings. Results: Of the 165 patients, 12 (7.3%) had secondary inflammation of the appendix on ultrasonography and/or CT. Patients with secondary inflammation of the appendix were significantly older than those without (11.7 vs. 6.1 years, p=0.011) and more frequently had fever (83.3% vs. 49.0%, p=0.033), and high values of C-reactive protein (CRP) (5.38 vs. 0.32 mg/dL, p<0.001). The proportion of bacterial pathogens was higher in patients with secondary inflammation of the appendix (60% vs. 15.1%, p=0.004). Conclusion: Patients with acute enterocolitis accompanied by secondary appendicitis more commonly have fever, higher CRP levels, higher bacterial pathogen detection rates, and longer hospital stays. Treatment equivalent to that of bacterial infection is required for patients with secondary appendicitis, and that their symptoms should be closely and continuously monitored and followed-up.