Method of Making the Distribution of Voxels Uniform within the Volumetric 3D image Space

  • Lin, Yuanfang;Liu, Xu;Xie, Xiaoyan;Liu, Xiangdong;Li, Haifeng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1138-1141
    • /
    • 2008
  • By defining a uniform reference point array corresponding to the 3D voxel array and abandoning voxels whose deviations from their respective reference points exceed a given tolerance, the distribution of voxels within the volumetric 3D image space gets uniform, effects of non-uniform distribution upon the image reconstructing are eased.

  • PDF

High-accuracy quantitative principle of a new compact digital PCR equipment: Lab On An Array

  • Lee, Haeun;Lee, Cherl-Joon;Kim, Dong Hee;Cho, Chun-Sung;Shin, Wonseok;Han, Kyudong
    • Genomics & Informatics
    • /
    • 제19권3호
    • /
    • pp.34.1-34.6
    • /
    • 2021
  • Digital PCR (dPCR) is the third-generation PCR that enables real-time absolute quantification without reference materials. Recently, global diagnosis companies have developed new dPCR equipment. In line with the development, the Lab On An Array (LOAA) dPCR analyzer (Optolane) was launched last year. The LOAA dPCR is a semiconductor chip-based separation PCR type equipment. The LOAA dPCR includes Micro Electro Mechanical System that can be injected by partitioning the target gene into 56 to 20,000 wells. The amount of target gene per wells is digitized to 0 or 1 as the number of well gradually increases to 20,000 wells because its principle follows Poisson distribution, which allows the LOAA dPCR to perform precise absolute quantification. LOAA determined region of interest first prior to dPCR operation. To exclude invalid wells for the quantification, the LOAA dPCR has applied various filtering methods using brightness, slope, baseline, and noise filters. As the coronavirus disease 2019 has now spread around the world, needs for diagnostic equipment of point of care testing (POCT) are increasing. The LOAA dPCR is expected to be suitable for POCT diagnosis due to its compact size and high accuracy. Here, we describe the quantitative principle of the LOAA dPCR and suggest that it can be applied to various fields.

1차원 배열 탐촉자의 방사빔추적기법을 이용한 정적 3차원 초음파진단영상 구성 (Construction of Static 3D Ultrasonography Image by Radiation Beam Tracking Method from 1D Array Probe)

  • 김용태;도일;안봉영;김광연
    • 비파괴검사학회지
    • /
    • 제35권2호
    • /
    • pp.128-133
    • /
    • 2015
  • 원격진료를 요하는 응급현장에서 사용을 위하여 1차원 배열 탐촉자를 손으로 조작하는 동안 변하는 방사빔의 위치를 추적하여 정적인 3차원 초음파영상을 구성하였다. 탐촉자에 고정된 모션센서의 병진운동 및 회전운동에 대한 정보를 기준직교좌표계로 변환하는 이론적 모델을 제시하였으며, 신호 증폭과 시리얼 통신을 위한 인터페이스 용도의 모듈을 상용의 센서를 사용하여 제작하였다. 실리콘 퍼티로 제작된 시험용 팬텀에 대한 B-모드의 동영상과 센서의 신호를 동기화하여 기록하였다. 동영상으로부터 주기적으로 추출한 B-모드 영상과 각 영상내의 픽셀 각각의 그레이 레벨을 이용하여 3차원 복셀의 그레이 레벨을 재구성하였다. 이 복셀의 데이터를 이용하여 3차원 영상과 임의단면의 B-모드 방식의 2차원 영상을 구성하였으며, 이 영상들은 시험용 팬텀의 형상과 잘 일치하였다.

Photogrammetry 기법을 활용한 MSC 설치면의 정밀 측정

  • 우성현;김홍배;문상무;임종민
    • 항공우주기술
    • /
    • 제3권1호
    • /
    • pp.126-133
    • /
    • 2004
  • 사진측량법(Photogrammetry)는 서로 다른 촬영각을 가지는 다수의 2차원 이미지로부터 대상물의 정밀한 3차원 형상을 얻어내는 기법이다. 본 연구에서는 사진측량법을 활용하여 다목적 실용위성 2호 비행모델 하부 탑재체 플랫폼(Low Payload Platform)의 고해상도 카메라 접합면에 대한 편평도(Flatness) 측정 작업을 수행하였으며, 정밀하게 교정된 2개의 스케일바(Scale Bar)를 사용하여 절대적인 길이 값을 3차원 모델에 부과함과 동시에 측정정확도를 계산하여 내었다. 또한 측정된 편평도 결과는 고해상도 카메라 납품 업체에서 제시한 편평도 요구조건과 비교되었다.

  • PDF

Patient-Specific Quality Assurance in a Multileaf Collimator-Based CyberKnife System Using the Planar Ion Chamber Array

  • Yoon, Jeongmin;Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.59-65
    • /
    • 2018
  • This paper describes the clinical use of the dose verification of multileaf collimator (MLC)-based CyberKnife plans by combining the Octavius 1000SRS detector and water-equivalent RW3 slab phantom. The slab phantom consists of 14 plates, each with a thickness of 10 mm. One plate was modified to support tracking by inserting 14 custom-made fiducials on surface holes positioned at the outer region of $10{\times}10cm^2$. The fiducial-inserted plate was placed on the 1000SRS detector and three plates were additionally stacked up to build the reference depth. Below the detector, 10 plates were placed to avoid longer delivery times caused by proximity detection program alerts. The cross-calibration factor prior to phantom delivery was obtained by performing with 200 monitor units (MU) on the field size of $95{\times}92.5mm^2$. After irradiation, the measured dose distribution of the coronal plane was compared with the dose distribution calculated by the MultiPlan treatment planning system. The results were assessed by comparing the absolute dose at the center point of 1000SRS and the 3-D Gamma (${\gamma}$) index using 220 patient-specific quality assurance (QA). The discrepancy between measured and calculated doses at the center point of 1000SRS detector ranged from -3.9% to 8.2%. In the dosimetric comparison using 3-D ${\gamma}$-function (3%/3 mm criteria), the mean passing rates with ${\gamma}$-parameter ${\leq}1$ were $97.4%{\pm}2.4%$. The combination of the 1000SRS detector and RW3 slab phantom can be utilized for dosimetry validation of patient-specific QA in the CyberKnife MLC system, which made it possible to measure absolute dose distributions regardless of tracking mode.

세기조절방사선치료의 환자별 정도관리를 위한 2차원적 선량계의 유용성 평가 (Comparison of the Efficacy of 2D Dosimetry Systems in the Pre-treatment Verification of IMRT)

  • 홍채선;임종수;주상규;신은혁;한영이;안용찬
    • Radiation Oncology Journal
    • /
    • 제27권2호
    • /
    • pp.91-102
    • /
    • 2009
  • 목 적: 세기조절방사선치료에 있어서 치료 전 환자별 정도관리(QA)에 사용하는 EDR2 필름과 2차원 이온전리함배열(MatriXX), 그리고 전자포탈영상장치(EPID)에 대해 절대선량계와 상대선량계로서의 정확도와 효율성을 평가했다. 대상 및 방법: 6 MV X-선을 이용하여 두 가지 유형(기준 조사면, 오차 평가 조사면)의 세기조절 조사면을 설계하고 EDR2 필름, MatriXX, EPID를 사용하여 절대선량과 상대적 선량분포를 비교, 분석했다. 세 시스템의 절대선량 정확성을 평가하기 위해 세 시스템의 선량 측정값과 전리함 측정값을 비교했고, 상대적 선량분포 평가를 위해 기준 조사면과 의도적으로 MLC leaf 위치를 변형시킨 오차 평가 조사면에서 감마($\gamma$)값과 조사면 수직 프로파일을 분석했다. 또한, 환자별 QA 전 과정을 수행하는데 소요되는 시간을 측정하여 시스템에 따른 업무 부하를 비교했다. 결 과: EDR2 필름, MatriXX, 그리고 EPID의 절대선량 측정값과 전리함 측정값을 비교한 결과 EPID는 1%, MatriXX는 2%, EDR2 필름은 3% 이내의 오차 측정 정확도를 보였다. EDR2 필름과 EPID는 허용기준 3%/3 mm와 2%/2 mm 모두에서 감마값이 1을 초과하는 화소($\gamma$%>1)가 전체 화소의 2% 이내였다. 그러나 MatriXX의 경우 3%/3 mm에서는 1% 이내의 오차를 보였으나 2%/2 mm를 적용한 $10\times20\;cm^2$$10\times10\;cm^2$에서는 각각 5.94%와 4.95%로 증가했다. 세 시스템으로부터 얻은 오차 평가 조사면의 선량 분포를 치료계획 장치로부터 얻은 기준 조사면과 중첩하여 감마 분석한 결과, 3%/3 mm에서 EDR2 필름이 -4 mm의 MLC leaf 오차 식별이 가능했고 EPID는 -3 mm 오차를 감지했다. 2%/2 mm의 경우, EDR2 필름과 EPID에서 각각 -3 mm와 -2 mm의 오차 식별이 가능했다. 그러나 MatriXX의 경우 경계가 불분명해 오차 구분이 어려웠다. 환자별 QA 전 과정을 수행하는데 소요되는 시간은 EDR2 필름이 약 110분, MatriXX가 약 80분, EPID가 약 55분이었다. 결 론: 본 연구는 IMRT의 치료 전 환자별 QA를 위한 EDR2 필름, MatriXX, 그리고 EPID의 측정 정확도와 효율성을 분석했다. EDR2 필름과 EPID는 선량 측정 정확도가 우수했으며, MatriXX는 측정 시간이 짧았다. 본 연구 결과는 임상에서 효율적인 IMRT QA 시스템을 구축하는데 좋은 자료가 될 것으로 생각한다.