• Title/Summary/Keyword: 3D probe

Search Result 408, Processing Time 0.026 seconds

A Study on the Sensitivity Compensation of Three-dimensional Acoustic Intensity Probe in the Higher Frequency Range (3차원 음향 인텐시티 프로브의 고주파 영역 감도 보상 연구)

  • Kim, Suk-Jae;Hideo, Suzuki;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.40-50
    • /
    • 1994
  • In this paper, the sensitivity compensation method for three-dimensional acoustic intensity probe in the higher frequency range has been studied. The measurement error in the higher frequency range is generated from the phase mismatch between microphone's signals of the probe. If the wavelength of sound signal measured is less than those of the distance between microphones of the probe, that is, the higher frequency of the sound signal, the bigger measurement error is generated. In this study, we proposed the compensation methods for one-dimensional acoustic intensity probe with two-microphones, and the efficiency of those methods were investigated by numerical calculation of computer. It was most effective method to compensate the phase mismatch between microphone for the acoustic intensity probe was investigated for the sound estimated. and the efficiency of this method in a three-dimensional probe was investigated for the sound wave travelling in the arbitrary direction by numerical calculation of computer. In this result, the efficiency was proved that, for the measurement error of 1dB or less with the three-dimensional probe of 60mm space, the frequency should be less than 1.2kHz without the error compensation method, but the frequency increased up to 2.8kHz with the error compensation method.

  • PDF

Design and Fabrication of an Electric-Field Probe Using Short Dipole Antennas (소형 이극안테나를 이용한 전계강도 프로브의 설계 및 제작)

  • 김혁제;박동철;이애경;심환우
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.1
    • /
    • pp.3-9
    • /
    • 1995
  • An isotropic electric-field probe, capable of characterizing and quantifying electromagnetic field, was fabricated. The probe consists of three short dipole antennas, a beam-lead Schottky diode and the high resistive transmission line. In order to get the isotropic response three mutually orthogonal dipoles are configured to form the probe. The probe's short dipole elements allow measurements of electric fields from 300MHz to 2GHz with a flatness of .+-. 2.9dB. The mutually orthogonal dipole configration shows a .+-. 1.2dB deviation in the isotropic response with respect to angle.

  • PDF

Numerical analysis for nearfield measurement error in a three-dimensional intensity probe. (3차원 인텐시티 프로브의 근거리 음장 측정에서의 오차 수치해석)

  • Kim, Suk-Jae;Jee, Suk-Kun;Suzuki, Hideo;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.41-50
    • /
    • 1994
  • We studied an inherent error be caused by a measuring acoustic intensity using probe which can measure simultaneously the three-dimensional acoustic intensity. This three-dimensional intensity probe was constructed with four microphones, proposed by Suzuki et al. . In the computer simulation, we analyzed the nearfield measurement error with arbitary direction and each of axis direction on the ideal point source and the plate sound source which have finite size. From the results, in case of point source, we obtained accurate measurement below about 1dB when the distance of measurement was about 2.5 times with the distance among microphones in this probe. And in the case of plate sound source, the nearfield measurement error was decreased as the length of one side became above 0.02m, we obtained accurate measurement below about 1dB when the length of one side is 0.2m. The nearfield measurement error of finite size sound is small to ignore. Therefore this probe is useful to measure nearfield intensity.

  • PDF

Comparison of ECT Probes in Diagnosis of Defects

  • Mun, Ho-Young;Kim, Chang-Eob
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.190-196
    • /
    • 2014
  • In this paper, the characteristics of a defective elliptical aluminum plate are analyzed by three different eddy current testing probes; T/R, T/T, and Impedance probes. The analysis was done by 3D finite element method, and the impedance change of real and imaginary voltage values were analyzed.

Review paper: Application of the Pulsed Eddy Current Technique to Inspect Pipelines of Nuclear Plants

  • Park, D.G.;Angani, C.S.;Kishore, M.B.;Vertesy, G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.342-347
    • /
    • 2013
  • Local wall thinning in pipelines affects the structural integrity of industries, such as nuclear power plants (NPPs). In the present study, a development of pulsed eddy current (PEC) technology that detects the wall thinning of pipelines covered with insulation is reviewed. The methods and experimental results, which have two kinds of probe with a single and double core, were compared. For this purpose, the single and double core probes having one and two excitation coils have been devised, and the differential probe with two Hall sensors has been fabricated to measure the wall thinning in insulated pipelines. The test sample is a stainless steel having different thickness, laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe is driven by a rectangular current pulse, the difference of two Hall sensors has been measured as a resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The double core probe has better performance to detect the wall thinning covered with insulation; the single core probe can detect the wall thinning up to an insulation thickness of 18 mm, whereas the double probe can detect up to 25 mm. The results show that the double core PEC probe has the potential to detect the wall thinning in an insulated pipeline of the NPPs.

Detection of Japanese Encephalitis Virus by Biotinylated cDNA Probe (Biotin으로 표지된 cDNA Probe를 이용한 일본 뇌염 바이러스의 검색)

  • 황동연;신영오;임정빈
    • Korean Journal of Microbiology
    • /
    • v.26 no.3
    • /
    • pp.149-154
    • /
    • 1988
  • Japanese Encephalitis Virus(JEV) can be detected conveniently by the use of biotinylated cDNA probe. To prepare biotinylated probe aminoallyl dUTP was first synthesized chemically to reverse transcribe the virial RNA. The allylamine-labeled cDNA was then converted to the biotin-cDNA by the reaction with an activated biotin ester, NHS-ACA-biotin. The JEV genomic RNA was hybridized to the biotinylated cDNA probe on nitrocellulose filter and visualized colorimetrically by streptavidin complexes with alkaline phosphatase polymer. Sensitivity of the detection system was determined by estimating the amount of the JEV genomic RNA through comparison with signals generated from the biotinylated and $^{32/P}$ -labeled probes. It was found that the biotin probe was as sensitive as $^{32/P}$ -cDNA probe which can detect 50pgs of the target RNA.

  • PDF

An Analysis of a Coaxial-to-Cavity Filter Including a Discended Probe and a Tuning Post by Finite Difference Time Domain Method (終端板 프로브와 동조 포스트가 포함된 동축선 對 캐비티 필터의 시간영역 유한차분법에 의한 해석)

  • 백락준;허문만;윤현보
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.3
    • /
    • pp.378-385
    • /
    • 1998
  • A three-dimensional finite difference time domain (3-D FDTD) algorithm of calculation for the characteristics of coaxial-to-cavity filter including a discended probe and a tuning post is presented. In the arrangement the inner coaxial conductor protrudes into the cavity and operates as a probe radiator. And the height of the rectangular tuning post determines the resonant frequency. The validation of this method is confirmed by comparing the calculated values with experimental results for the designed filter.

  • PDF

Broadband Characterization of Circularly Polarized Waveguide Antennas Using L-Shaped Probe

  • Fukusako, Takeshi
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • This paper introduces a technique to obtain the broadband characteristics of circularly polarized antennas using an L-shaped probe. A waveguide antenna is suitable for obtaining high gain and handling convenience in some applications; however, the asymmetrical structure of the L-shaped probe results in cross-polarization and frequency dependence on the field distribution of higher-order modes (HOM). In addition to the basic characteristics of a waveguide antenna with an L-shaped probe, the author discusses some techniques to reduce the HOM and cross-polarization. As a result, the 3-dB axial ratio (AR) is obtained with the fundamental mode even when the frequency is expanded to the region for HOM of TM. This reduction is mainly due to the cutoff structure to the TM mode around the short wall of the waveguide. Furthermore, some aperture modification techniques can reduce the cross-polarization in a wide range of angles in the radiation pattern. Such techniques and their mechanisms are discussed in this paper. The obtained performance shows that the proposed antennas have a wide range of angles of 3-dB AR in the radiation pattern, broadband characteristics in impedance and AR, and low variation in group velocity.

Non-contact critical current measurement of superconducting coated conductor using Hall Probe (Hall Probe를 이용한 초전도선재의 비접촉 임계전류 측정 방법)

  • Kim, Ho-Sup;Oh, Sang-Soo;Lee, Nam-Jin;Ha, Dong-Woo;Baik, Seung-Kyu;Ko, Rock-Kil;Ha, Hong-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.12-12
    • /
    • 2010
  • The hall probe measurement system was used to measure the critical current distribution of superconducting coated conductor. The system consists of reel to reel moving apparatus, 7 array hall probe, a rotary encoder and permanent magnet. The magnetic field profile across the width of superconducting coated conductor using Bean's critical state model was calculated. The effect of various parameters of the formulas on the magnetic field distribution and the effect of shape and size of artificial defects, which were formed on the surface of SmBa2Cu3O7-d(SmBCO) coated conductor using laser marking system, on the hall probe magnetic field signal of the hall probe measurement system was investigated.

  • PDF

2-D/3-D Combined Algorithm for Automatic Solder Paste Inspection (솔더 페이스트 자동검사를 위한 2-D/3-D 복합 알고리즘)

  • 조상현;이상윤;임쌍근;최흥문
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.173-176
    • /
    • 2002
  • In this paper, we present the combined 2-D and 3-D algorithms for automatic solder paste inspection. For automatic inspection, optical system for the combined inspection and driving unit is made. One-pass run length algorithm that has fast and efficient memory space is applied to the input image fur extracting solder paste patterns. The path of probe movement is then calculated for an automatic inspection. For a fast 3-D inspection, the phase shift algorithm based on Moire interferometry is also used. In addition, algorithms used in this paper are coded by $MMX^{TM}$. A probe system is manufactured to simultaneously inspect 2-D and 3-D for 10mm$\times$10mm field of view, with resolutions of 10 $\mu\textrm{m}$for both x, y axis and 17 $\mu\textrm{m}$for z axis, and then, experiments on several PCBs are conducted. The processing times of 2-D and 3-D, excluding an image capturing, is 0.039 sec and 0.047 sec, respectively. The credible result with $\pm$ 1$\mu\textrm{m}$uncertainty can be also achieved.

  • PDF